CO2 incubator with additional process controls

Similar documents
CO2 incubator with additional process controls

CO2 incubator with additional process controls

NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

CO2 INCUBATOR CO2 INCUBATORS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

CO2 Incubator. LCO-A Series

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

HumiSys HF High Flow RH Generator

MANUAL KPS Pressure Control Valve

PERFORM Operating Document

PERFORM Operating Document

Oxygen Flue Gas Analyzer BA 2000

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Flow Controller (MFC) for Gases

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Columbus Instruments

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Continuous Gas Analyzers, extractive

Mass Flow Controller (MFC) for Gases

Instruction and Maintenance Manual

Pressure transmitter PASCAL Ci4

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Datasheet: K-30 ASCII Sensor

KERN EG/EW Version /02

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

We measure it. For gas and water installers. testo hpa. bar

Gas density monitor With integrated transmitter Model GDM-100-TI

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Precision pressure sensor Basic version Model CPT6020

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Supplementary Operator s Manual 42/24-14 EN Rev. 3

FAS-W. Features. Applications. Automatic condensation hygrometer

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Optical Dissolved Oxygen Meter

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Instruction and Maintenance Manual

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

SonoMeter 30 Energy Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Installation and Operation Manual

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Mass Flow Meter (MFM) for Gases

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Additel 761 Automated Pressure Calibrators Selection Guide

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Additel 761 Automated Pressure Calibrators

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Online data sheet FLOWSIC30 GAS FLOW METERS

C-Flow Coriolis Mass Flow Meters

Optical Dissolved Oxygen Meter

User Manual PTW-DensiX. D / Di/Zi

BUBBLER CONTROL SYSTEM

Mass Flow Controller (MFC) for Gases

with O 2 Controller Instruction Manual

FLAMMABLE GAS SENSOR/TRANSMITTER

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Additel 761 Automated Pressure Calibrators Selection Guide

Operating Instructions CO2 Incubator symphony 6.5 W

Differential Pressure Transmiter

Mass Flowmeters. Mass Flowmeters for Gases

FTC130 Transmitter. Operating Manual

Hand-held pressure calibrator with integrated pump Model CPH6600

ASDX Series Silicon Pressure Sensors

TH-1800-T TRX-700-CNG Converter

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Pressure Transmitter P41

Instruction Manual Dräger MSI P7 and MSI P7 plus

BUBBLER CONTROL SYSTEM

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

LT GasAnalyzer beyond standards

Improve Process Reliability

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Customer Responsibilities

GasSense NDIR User Manual

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

BF Incubators with forced convection

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Membrane covered optical CO 2 sensor

Transcription:

CB series 53 C2 Incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER C2 incubator of the CB series is up to even complex cultivation experiments or individual environments. Advantages: Hot air sterilization at 180 C Seamless, deep-drawn inner chamber made of stainless steel Unique BINDER technology (patented air jacket system, controlled condensation, etc.) Areas of application: Bio Tissue Engineering In vitro Fertilization (IVF)Clinics / University Hospitals

Customer benefits Features Customer benefits Characteristics Sterilization Complete elimination of bacteria, spores, etc. Reliable sterilization of the atmosphere and all surfaces Minimal sterilization costs 180 C hot air sterilization Standards compliance, meets all relevant standards Automatic sterilization process Permadry humidity system APT.line heating technology Uniform osmotic cell pressure ptimum cell growth even with microwell plates No Provides no sources of contamination. ptimal, uniform cell growth throughout the inner chamber Controlled humidification system Defined recondensation point Dry interior walls High humidity Rapid humidity recovery times Simple water exchange through water pan Preheating chamber with VENTAIR air jacket Homogeneous temperature distribution Rapid recovery after temperature drop Accurate temperature control Gas distribution Stable ph value Gas mixing head with venturi effect Homogeneous C2 distribution Fast effective aeration Inner chamber concept C2 measurement perating costs Easy cleaning Fully usable volume 53, 150, 210 l No Provides no sources of contamination. Stable ph value even with frequent door opening Long-term stable system Low maintenance costs Minimal operating costs Time savings Seamless, deep-drawn inner chamber Integrated shelf support system Burr-free stainless steel perforated sheets with tilt protection Single-beam infrared sensor Rapid response time Measures C2 in real-time Independent of gas and humidity Minimal work and material costs for sterilization BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and best cell growth Temperature range from 7 C above ambient temperature to 60 C MCS controller for temperature and C2 concentration User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real time clock Standard-compliant hot air sterilization at 180 C (DIN 58947) VENTAIR Jacket System Drift-free infrared C2 measurement system Patended Gas mixing nozzle Permadry System - condensation-free double-pan humidification system, maintains dry interior walls Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges) Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm Tightly-fitted inner glass door RS 422 interface for communication software APT-CM DataControlSystem 2 perforated stainless steel shelves with standard equipement and 2 control Units are stackable with stacking adapter Door lock BINDER test confirmation BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications CB 53 Exterior dimensions Width (mm) 580 Height (incl. feet) (mm) 720 Depth (plus 55 mm for door handle and connection) (mm) 550 Wall clearance side / rear (mm) 50 / 100 Number of doors (ea.) 1 Inner glass door(s) 1 Interior dimensions Width (mm) 400 Height (mm) 400 Depth (mm) 330 Interior volume (l) 53 Number of shelves (standard/max.) 2 / 3 Dimensions shelves width x depth (mm) 396 x 289 Load per shelf (kg) 10 Permitted total load (kg) 30 Weight (empty) (kg) 60 Temperature data Temperature range from 5 C above ambient temperature to ( C) 60 Temperature variation at 37 C (± K) 0,3 Temperature fluctuation at 37 C (± K) 0,1 Recovery time after door was opened for 30 sec. at 37 C (min.) 1) 3 Humidity data Humidity (±2% r.h.) 95 C2 data C2 range (vol. % C2) 0-20 Setting accuracy (Vol.-% C2) 0,1 Recovery time after door was opened for 30 sec. 1) at 5.0 vol. % C2 (min.) 6 C2 measurement IR Connection hose nozzle for C2 for hose with internal diameter (mm) 6 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications CB 53 2 data 2 range (vol. % 2) 0,2-95 Setting accuracy (Vol.-% 2) 0,1 Recovery time after door was opened for 30 sec. 1) at 1.0 vol. % 2 (min.) 25 at 5.0 vol. % 2 (min.) 9 2 measurement Zr2 Connection hose nozzle for 2 / N2 for hose with internal diameter (mm) 6 Electrical data Voltage (± 10%) 50/60 Hz (V) 230 Nominal power (kw) 1,0 Energy consumption at 37 C (W) 2) 70 1) up to 98 % of the set value 2) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions BINDER Gas Supply Service The external tank changer makes automatic changeover to a second tank possible once the first tank is empty. It has acoustic and visual alarms and is equipped with a zero-voltage alarm output for extreme notification systems. It can be used for maximum two C2 incubators and is suitable for C2, 2 and N2 tanks. Gas-tight, 4-way divided inner glass door For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and C2 when loading. Ensures short recovery times. Control for variable 2 values For hyper- or hypoxic culture conditions. The 2 or N2 gas supply can be controlled using an additional control loop as needed. A zirconium oxide sensor (Zr2) is used for the measurement. Silicone access ports For introducing external measuring instruments into the chamber. The access ports have a diameter of 30 mm and can be sealed on both sides using a silicone plug. They can be positioned on the back, left, and right sides. Stacking adapter Used for stacking of two CB incubators which are thermally isolated from each other. The incubators can thus be sterilized with hot air independent of each other. Available as stacking adapters, stacking frames or base frames. APT-CM DataControlSystem GLP Edition Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements. Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions CB 53 Silicone access port with two silicone plugs, 30 mm, back Lockable controller keyboard Gas tank connection set for C2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose Gas tank connection set for 2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m hose BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either C2 or N2, with audible and visual alarms, as well as potential-free alarm output Unit conversion from RS 422 to Ethernet interface 4-20 ma analog outputs for temperature and C2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable) Switched LEM inner chamber socket (coverable) and LEM connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the C2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door Calibration certificate for temperature and C2 (temperature measurement in center / C2 measurement performed using analyzed test gas at 37 C and 5% C2) Calibration certificate for optional 2 control, 2 measurement with analyzed test gas 1% 2 Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 C or at specified temperature with measuring protocol and certificate Manual for Primary Human Cell Culture, in English Shelf, perforated, stainless steel Shelf, stainless steel for divided gas-tight inner glass door Base on casters Stacking adapter for direct thermal decoupled stacking of two C 53 C2 incubators Distributore Autorizzato: Geass S.r.l. - Torino - Tel.: +39 011.22.91.578 - info@geass.com - web site: www.geass.com BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany