CO2 incubator with additional process controls

Similar documents
CO2 incubator with additional process controls

CO2 incubator with additional process controls

NEW: CO2 incubator with sterilizable sensor

NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

CO2 incubator with additional process controls

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

CO2 INCUBATOR CO2 INCUBATORS

PERFORM Operating Document

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PERFORM Operating Document

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

HumiSys HF High Flow RH Generator

CO2 Incubator. LCO-A Series

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

MANUAL KPS Pressure Control Valve

Columbus Instruments

KERN EG/EW Version /02

Mass Flow Controller (MFC) for Gases

We measure it. For gas and water installers. testo hpa. bar

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Continuous Gas Analyzers, extractive

Mass Flow Controller (MFC) for Gases

Precision pressure sensor Basic version Model CPT6020

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Datasheet: K-30 ASCII Sensor

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

SonoMeter 30 Energy Meters

Pressure Transmitter P41

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Instruction and Maintenance Manual

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

FAS-W. Features. Applications. Automatic condensation hygrometer

Oxygen Flue Gas Analyzer BA 2000

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Optical Dissolved Oxygen Meter

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

PRC CO ² -LASER PRESENTATION

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

Operating Instructions CO2 Incubator symphony 6.5 W

Additel 761 Automated Pressure Calibrators Selection Guide

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

ASDX Series Silicon Pressure Sensors

Autocalibration Systems For In Situ Oxygen Analyzers

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Model 601CV. Mass Flow Controller. Product Features:

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

TH-1800-T TRX-700-CNG Converter

Mass Flow Meter (MFM) for Gases

Gas density monitor With integrated transmitter Model GDM-100-TI

with O 2 Controller Instruction Manual

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

BUBBLER CONTROL SYSTEM

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

EPP4 Pressure Regulator Basic G 1/4"

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Climatic Independent Level Sensor LAR

Real-time gas analysis and software for the management of bioprocessing

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Optical Dissolved Oxygen Meter

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Online data sheet FLOWSIC30 GAS FLOW METERS

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Improve Process Reliability

BUBBLER CONTROL SYSTEM

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

VSR modulating valves with membrane actuator

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

How to specify a product. Process Sensors and Mechanical Instruments

GasSense NDIR User Manual

Instruction and Maintenance Manual

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Series Environmental Chambers

Model EXAxt AV550G. Averaging Oxygen Analyzer

Installation and Operation Manual

Transcription:

CB series 150 C2 incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER C2 incubator of the CB series is up to even complex cultivation experiments or individual environments. Advantages: Hot air sterilization at 180 C (356 F) Seamless, deep-drawn inner chamber made of stainless steel Unique BINDER technology (patented air jacket system, controlled condensation, etc.) Areas of application: Bio Tissue Engineering In vitro Fertilization (IVF) Clinics / University Hospitals

Customer benefits Features Customer benefits Characteristics Sterilization Permadry humidity system APT.line heating technology Complete elimination of bacteria, spores, etc. Reliable sterilization of the atmosphere and all surfaces Minimal sterilization costs Uniform osmotic cell pressure ptimum cell growth even with microwell plates No Provides no sources of contamination. ptimal, uniform cell growth throughout the inner chamber 180 C (356 F) hot air sterilization Standards compliance, meets all relevant standards Automatic sterilization process Controlled humidification system Defined recondensation point Dry interior walls High humidity Rapid humidity recovery times Simple water exchange through water pan Preheating chamber with VENTAIR air jacket Homogeneous temperature distribution Rapid recovery after temperature drop Accurate temperature control Gas distribution Stable ph value Gas mixing head with venturi effect Homogeneous C2 distribution Fast effective aeration Inner chamber concept C2 measurement perating costs Easy cleaning Fully usable volume 53, 150, 210 l No Provides no sources of contamination. Stable ph value even with frequent door opening Long-term stable system Low maintenance costs Minimal operating costs Time savings Seamless, deep-drawn inner chamber Integrated shelf support system Burr-free stainless steel perforated sheets with tilt protection Single-beam infrared sensor Rapid response time Measures C2 in real-time Independent of gas and humidity Minimal work and material costs for sterilization

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and best cell growth Temperature range from 7 C (13 F) above ambient temperature to 60 C (140 F) MCS controller for temperature and C2 concentration User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real time clock Standard-compliant hot air sterilization at 180 C (356 F) (DIN 58947) VENTAIR Jacket System Drift-free infrared C2 measurement system Patented Gas mixing nozzle Permadry System - condensation-free double-pan humidification system, maintains dry interior walls Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges) Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm Tightly-fitted inner glass door RS 422 interface for communication software APT-CM DataControlSystem 3 perforated, stainless steel shelves with standard equipment and 2 control Units are stackable with stacking adapter Door lock BINDER test confirmation

Specifications CB 150 Exterior dimensions Width (mm/inch) 680 / 26.8 Height (incl. feet) (mm/inch) 920 / 36.2 Depth (plus 54 mm (2.1 inch) for door handle and connection) (mm/inch) 715 / 28.2 Wall clearance side (mm/inch) 50 / 1.97 Wall clearance rear (mm/inch) 100 / 3.94 Number of doors (ea.) 1 Inner glass door(s) 1 Interior dimensions Width (mm/inch) 500 / 19.7 Height (mm/inch) 600 / 23.6 Depth (mm/inch) 500 / 19.7 Interior volume (l/cu.ft.) 150 / 5.4 Stainless steel shelf (number standard/max.) 3 / 6 Dimensions of shelf, width x depth (mm/inch) 495 x 444 / 19.5 x 17.5 Load per shelf (kg/lbs.) 10 Permitted total load (kg/lbs.) 30 Weight (empty) (kg/lbs.) 107 / 236 Temperature data Temperature range from 7 C (13 F) above ambient temperature to ( C/ F) 60 / 140 Temperature variation at 37 C (98.6 F) (± K) 0.3 Temperature fluctuation (± K) 0.1 Recovery time after door was opened for 30 sec. at 37 C (98.6 F) (min) 1) 3 Humidity data Humidity (±2% r.h.) 95 C2 data C2 range (Vol.-% C2) 0-20 Setting accuracy (Vol.-% C2) 0.1 Recovery time after doors was opened for 30 sec. at 5 vol. % (min.) 1) 7 C2 measurement IR Connection hose nozzle for C2 DN 6 for hose with internal diameter (mm) 6 / 0.24

Specifications CB 150 2 data 2 range (Vol.-% 2) 0.2-95 Setting accuracy (Vol.-% 2) 0.1 Recovery time after door was opened for 30 sec. (min.) 1) at 1.0 vol. % 2 (min.) 33 at 5.0 vol. % 2 (min.) 10 2 measurement Zr2 Gas connection hose nozzle for 2 / N2 DN 6 for hose with internal diameter (mm/inch) 6 / 0.24 Electrical data Voltage (± 10%) 50/60 Hz (V) 230 Voltage (± 10%) 60 Hz (V) 115 Nominal power (kw) 1.3 Energy consumption at 37 C (98.6 F) (W) 2) 120 1) up to 98 % of the set value 2) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C (77 F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

ptions BINDER Gas Supply Service The external tank changer makes automatic changeover to a second tank possible once the first tank is empty. It has acoustic and visual alarms and is equipped with a zero-voltage alarm output for extreme notification systems. It can be used for maximum two C2 incubators and is suitable for C2, 2 and N2 tanks. Gas-tight, 4-way divided inner glass door For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and C2 when loading. Ensures short recovery times. Gas-tight, 4-way divided inner glass door For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and C2 when loading. Ensures short recovery times. Silicone access ports For introducing external measuring instruments into the chamber. The access ports have a diameter of 30 mm (1.2 inch) and can be sealed on both sides using a silicone plug. They can be positioned on the back, left, and right sides. Stacking frame For staking two BINDER CB 150 C2 incubators APT-CM DataControlSystem GLP Edition Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements. Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.

ptions CB 150 Silicone access port with two silicone plugs, 30 mm (1.2 inch), left side Silicone access port with two silicone plugs, 30 mm (1.2 inch), right side Silicone access port with two silicone plugs, 30 mm (1.2 inch), back Keyboard Lock Gas tank connection set for C2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose Gas tank connection set for 2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either C2 or N2, with audible and visual alarms, as well as potential-free alarm output Unit conversion from RS 422 to Ethernet interface 4-20 ma analog outputs for temperature and C2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable). Switched LEM inner chamber socket (coverable) and LEM connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the C2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door Calibration certificate for temperature and C2 (temperature measurement in center / C2 measurement performed using analyzed test gas at 37 C (98.6 F) and 5% C2 Calibration certificate for optional 2 control, 2 measurement with analyzed test gas 1% 2 Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 C (98.6 F) or at specified temperature with measuring protocol and certificate Manual for Primary Human Cell Culture, in English Current feedthrough (8-pin) for low voltage with LEM socket (pluggable) and LEM plug Internal C2 tank changer for connecting 2 gas tanks. Precise control over the current condition of C2 supply to incubator by means of alarm messaging and incident reporting Internal C2 tank changer for connecting 2 gas tanks with external connection for up to one additional C2 incubator. Precise control over the current condition of C2 supply to incubator by means of alarm messaging and incident reporting Internal 2 and N2 tank changer for connecting 2 gas tanks each Perforated shelf, stainless steel Divided shelf (1 shelf level) for gas-tight divided inner glass door, stainless steel Base on casters for CB 150 Stable vibration-free stacking frame on casters with stop brake for direct and safe stacking of two units of the CB 150 series Stacking adapter for direct thermal decoupled stacking of two C 150 C2 incubators Stacking adapter C / CB, for direct thermal decoupled stacking of two CB 150 / C 150 unit combinations CELLRLL Set, modular and expandable roller bottle system for cell cultivation, 4 roller bottles