HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

Similar documents
ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Safety instructions and operating manual

VERTICAL AIR COMPRESSORS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

INDUSTRIAL - SOLVENT PARTS CLEANER

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

Instruction Manual Recovery Station

Med Aire Alternating Pressure Pump and Pad System

VERTICAL AIR COMPRESSORS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Paradise Pump Series Operator s Manual

Oxygen Concentrator Instruction

Lil Mix Controller (Order code: LEDJ122)

SILENTAIRE TECHNOLOGY

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Installation of Your SprayMaster System

100C Air Compressor Kit

444C DUAL PERFORMANCE VALUE PACK

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Portable oxygen concentrator

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

COMPRESSOR MANUAL. (888)

03/07/2014 V

200 PSI COMPRESSORS - MODEL NUMBERS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

OWNER S MANUAL NMB SERIES

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

Nitrogen Tyre Inflator Owner s Manual

400C & 450C DUAL PERFORMANCE VALUE PACKS

Model PSI Compressor with 3-Gallon Air Tank 12VDC

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Manual Actuated Boiler Blowdown Valves

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

User Manual for the Mars Calibration Bench

12V AIR STATION ALL-IN-ONE

SILENTAIRE TECHNOLOGY

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

oxyoasis oxygen facial system

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

LSX Low Smoke Convertor Operations Manual

R E D I C O N T R O L S

IMPORTANT SAFETY INSTRUCTIONS

User Instruction Manual

Installation, Operation & Maintenance Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

ULTRA QUIET & OIL FREE

E Cube Lift Model: ECU Installation Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

R2S Standard Sampling Assembly OPERATION PROCEDURE

CAUTION: YOU MUST READ THE FOLLOWING BEFORE OPERATING THE SNOWMAN.

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Instruction Manual for Configura Cushionair Portable Pump

Model Air Caddy Orig TABLE OF CONTENTS

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

36H SERIES Combination Gas Valve

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Setup Guide for your HVO Naked Drone

BUBBLER CONTROL SYSTEM

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

OUTDOOR LED SCOREBOARD CARE & OPERATIONS MANUAL

USER MANUAL. JET TST and JET TST S.

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

G92 Series BASOTROL Automatic Pilot Gas Valve

200L BELT DRIVEN AIR COMPRESSOR

SC505 Sof Care Inflator. Operating Instructions and Service Manual

OXYGEN MINERALE ABSOLUTE RANGE OWNER S MANUAL OXY MINERALE 600/1000 SERIES

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

USER MANUAL

Lubricated TC Models

AR740 RPS Redundant Power Supply Quick Install Guide

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

USER MANUAL. MACMAG magnetic separator MHK MHF

Koike Aronson, Inc./Ransome

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

Transcription:

HZ-300 HAZER MACHINE USER MANUAL Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine. Read and save these instructions 2005 Antari Lighting and Effects Ltd

2

User Manual Antari HZ-300 Hazer Congratulations on the purchase of your new ANTARI HAZER. Introduction Thank you for choosing an ANTARI Hazer. You now own a rugged and powerful state-of-the-art machine. Prior to use, we suggest that you carefully read all of the instructions. By following the suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of your ANTARI Hazer for years to come. Please follow these operation and safety instructions to ensure a long and safe life for your hazer. Cautions Do not overfill your ANTARI hazer. Overfilling will cause the unit to clog. Danger of electric shock Keep this device dry. For inside use only. Not designed for outside use. For the 110V models, use 3-prong grounded electrical outlet only. Prior to use take care to determine that the unit is installed at the rated voltage. Always unplug your ANTARI Hazer before filling its tank. Keep hazer upright. Turn off or unplug when not in use. This machine is not water- or splash-proof. If moisture, water, or hazer liquid gets inside the housing, immediately unplug the unit and contact a service technician or your ANTARI dealer before using it again. No user serviceable parts inside. Refer to your ANTARI dealer or other qualified service personnel. For adult use only. Hazer must be installed out of the reach of children. Never leave the unit running unattended. Never aim the output at open flames. Danger of explosion Never add flammable liquids of any kind (oil, gas, perfume) to the hazer liquid. Pay attention to all warning labels and instructions printed on the exterior of your ANTARI Hazer Use only the high-quality hazer liquid that your dealer recommends. Always make sure there is sufficient liquid in the hazer liquid tank. Operating this unit without liquid may cause permanent damage to the machine. If your ANTARI Hazer fails to work properly, discontinue use immediately. Drain all hazer liquid from the tank, pack the unit securely (preferably in the original packing material), and return it to your ANTARI dealer for service. Never drink hazer liquid. If it is ingested, call a doctor immediately. If hazer liquid comes in contact with skin or eyes, rinse thoroughly with water. 3

Unpacking & Inspection Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact. If any equipment is missing contact your ANTARI dealer immediately. Before beginning initial setup of your ANTARI Hazer, make sure that there is no evident damage caused by transportation. In the event that the unit s housing or cable is damaged, do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance. Setup Remove all packing materials from shipping box. Check that all foam and plastic padding is removed. Place hazer on a flat surface and remove hazer liquid tank cap. Note the maximum fluid level mark located on the front of the hazer. Pour hazer liquid into the liquid tank, being careful not to exceed the maximum fluid level. DO NOT OVERFILL. Use only ANTARI Hazer Liquid or other dealer-recommended high-quality hazer fluid. Any other types of fluid can damage the unit. When liquid level reaches the fill line, place cap back on liquid tank. Your hazer may be operated with or without a remote controller. If you will be controlling your unit remotely, firmly attach the remote control cable to the proper input. Operation Plug power cord into a grounded electrical outlet. To operate without remote control, simply turn hazer on. Haze emission will begin automatically. To operate via remote control, press the appropriate button on the remote to begin haze emission. For further information on operating your ANTARI Hazer, see the section titled, Remote Control Operation. If your model includes a mounting bracket designed for overhead installation, it may be installed at floor level or suspended overhead. If the unit is to be mounted using the bracket, avoid suspending the unit such that haze is emitted directly toward any one s face. Whatever installation method you choose, do not allow the unit to have more than a 15 degree angle of inclination. Important: Always monitor tank fluid level during operation. Running a hazer with no fluid can permanently damage the unit. If you experience low output, mechanical noise or no output at all, unplug immediately. Check fluid level, the external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the unit in again. If hazer does not function after 30 seconds, discontinue operation or permanent damage to the unit may result. Return the machine to your ANTARI dealer. Always drain tank before mailing or transporting this unit. Remote Control Operation HC-1: 10 meter wired multi-function remote controller with ¼ stereo plug for the ANTARI Hazer HZ-300. Its two knobs allow the operator to program hazer 4

functions by adjusting haze emission duration and interval. Press the yellow TIMERS button to activate the timer function. Adjust the interval between each haze emission (within the range of 10 seconds to 5 minutes) by means of the INTERVAL control knob. Adjust the duration of each haze emission (within the range of 1 to 10 seconds) by means of the DURATION control knob. When pressed, the green MANUAL button activates the hazer, overriding all other function controls. Press the red CONTINUOUS button for continuous output. HCR-1: Wireless remote controller with ¼ stereo plug for the ANTARI Hazer HZ-300. Attach the receiver s magnetic base to the hazer. Plug the receiver s cable into the hazer s remote control input. Using the sending unit, your ANTARI Hazer can be operated from a distance of up to 50 meters. Start haze emission by pressing the small button on the sending unit. Stop haze emission by pressing the large button. Multiple ANTARI Hazers may be controlled using only one sending unit. DMX Operation The HZ-300 has onboard DMX control. Currently, it uses 1 channel to control output operation. Each channel has a value range of 0 to 255. The DMX channel is set on the back panel of the HZ-300 by setting the dip switches to the desired channel. If Channel A has a value from 0 to 5, the unit is OFF; between the values 6 to 249, the unit is regulated. Note: In the example below, if the machine were assigned the DMX address of 124, Channel A would correspond to DMX address 124. Hazer Liquid Do not allow the hazer liquid to become contaminated. Always replace the caps on the hazer liquid container and the hazer s liquid tank immediately after filling. ANTARI Hazer Liquid comes in two varieties: ANTARI HZL-1 is a high-performance low-residue oil-based hazer liquid that has been designed specifically for HZ-100, HZ-300 and HZ-400. ANTARI HZL-1W is a non-residual water-based hazer liquid suitable for the HZ-100, HZ-300 and HZ-400. 5

Important: Never mix oil-based and water-based hazer liquids. Before switching the kind of hazer liquid in use, completely drain the hazer s tank to avoid mixing. Use only ANTARI Hazer Liquid or other dealer-recommended high-quality hazer fluid. Any other types of fluid can damage the unit. Save these instructions 6

7

C08HZ300 8