Code(s) DOT 49 CFR 173.3:

Similar documents
FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM

Dip Tanks Containing Flammable or Combustible Liquids Self-Inspection Checklist

NFPA Code Edition*** Chapter 14 Hazardous Materials Storage Lockers. (continued) Table Designated Sites. Between Individual Lockers

FLAMMABLE AND COMBUSTIBLE LIQUIDS SELF INSPECTION CHECKLIST

B&B Gas Well Services, LLC HEALTH, SAFETY AND ENVRONMENTAL MANUAL HAZARD COMMUNICATION PROGRAM

Material Safety Data Sheet Washmaster Juice Additive for use with the Mudmaster Washmaster

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

EMERGENCY PHONE: or (651) (24 hours)

Health and Safety at Work (Hazardous Substances Reduced Secondary Containment for Certain Above Ground Stationary Tanks) Safe Work Instrument 2017

Spray Finishing Self-Inspection Checklist

HAZARD COMMUNICATION STANDARD (HCS) GLOBALLY HARMONIZED SYSTEM (GHS)

CHAPTER 3.24 SWIMMING POOLS

MSC Guidelines for Pressure Vessels

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

MSC Guidelines for Independent Fuel Tanks

MATERIAL SAFETY DATA SHEET Scotch Box Sealing Tapes 302, 305, 309, 311, 313, 315, 3609 and Tartan Box Sealing Tapes 303 and /26/12

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Compliance with Health & Safety legislation

Safety Data Sheet. 503 Main Street Belle Chasse, LA 70037

GUIDELINES FOR SLUG DISCHARGE MANAGEMENT PLAN (Abstract from EPA Guidance Manual)

MATERIAL SAFETY DATA SHEET C-MUL SUN DRILLING PRODUCTS CORP.

HAZARD COMMUNICATION PROGRAM

EMERGENCY PHONE: or (651) (24 hours)

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Swimming pool defined.

WEBINARS. Hazard Communication

THE CORPORATION OF THE TOWNSHIP OF PUSLINCH BY-LAW NUMBER A by-law to regulate enclosures for outdoor swimming pools

FAQs: Confined Spaces in Residential Construction

Sixty-Day Notice Of Intent To Sue For Clean Water Act Violations By Suction Dredge Mining On Salmon River Without A Permit

EMERGENCY PHONE: or (651) (24 hours)

Having reviewed the Law on Constructional Organisation of Buildings promulgated by Legislative Decree No.(13) of 1977, as amended,

Hazardous Waste Training Plan. Supersedes: 02/15/16 (Rev.02) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

Inflammable Gases Regulations 1962

Class 8 Corrosive Substances Learning Tool

NPGA White Paper. OSHA Hazard Communication Standard

Environmental: Hazardous Waste: Satellite Accumulation Areas (SAA)

All Multi-Tech Non-Phthalate Color Inks MATERIAL SAFETY DATA SHEET

CONFINED SPACE WRITTEN PROGRAM

EMERGENCY PHONE: or (651) (24 hours)

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

SAFETY DATA SHEET. Section 2: Hazard Identification Classification of the chemical in accordance with paragraph (d) of :

Limited quantities of compressed gases.

Occupational Safety and Health Administration

General Inspection Guidance for Waste Management Units Requiring Air Emission Controls Under RCRA Air Standard Subpart CC

3M Disinfecting Desk & Office Wipes CL554 and CL564 3M Office Supplies Division. EMERGENCY PHONE: or (651) (24 hours)

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

D³ IFA Enterovirus Duo Pack Safety Data Sheet Revision Date: October 17, Section 1 Product and Company Identification

General Safety and Health Provisions for Construction Self Inspection Checklist

ISSUING AGENCY: New Mexico Department of Game and Fish. [ NMAC - Rp, NMAC, 01/01/2018]

Fall Hazards: One of OSHA s Big Three. By Mark A. Lies II and Elizabeth Leifel Ash I. INTRODUCTION

Chapter 23. Swimming Pools

Escondido Union High School District. Hazard Communication Plan

CHAPTER23 SWIMMING POOLS

SAFETY DATA SHEET

EMERGENCY PHONE: or (651) (24 hours)

SAFETY DATA SHEET 8/20/2015

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Hispanic Roofer s Fall Protection Failed Causing Him to Fall Feet to His Death Incident Number: 14KY030

HAZWOPER. A planning guide for the perplexed. The Oregon Occupational Safety & Health Division

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

Section 38 Brieser Construction SH&E Manual

Material Safety Data Sheet

Material Safety Data Sheet

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

SPECIALIZED ONLINE TRAINING COURSE LIST

Process Safety Management is the application of management principles and systems to the identification, understanding, and control of process

EMERGENCY PHONE: or (651) (24 hours)

IOWA HIGH SCHOOL ATHLETIC ASSOCIATION REVIEW OF BLOOD-BORNE PATHOGEN PROCEDURES

Material Safety Data Sheet SANTOLUBES LLC SANTOTRAC, SANTOVAC, SANTOLUBES, AND SYNERGY P.O. Box 960 St. Charles, MO

2.1. Hazard classification This product is exempt from hazard classification according to OSHA Hazard Communication Standard, 29 CFR

Swimming Pool Fence By-law

2009 NEW MEXICO SWIMMING POOL, SPA AND HOT TUB CODE

EMERGENCY PHONE: or (651) (24 hours)

Safety Data Sheet ZYMOX SHAMPOO. ADDRESS (NUMBER, STREET, CITY, STATE, ZIP): 710 Vandustrial Dr. Westmont, IL 60559

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

Swimming Pool Requirements

Material Safety Data Sheet. ATP Diluent

Model General Permit Template. SERIES 13 Tanks. Template # SJV-TK

Dip Tanks Self-Inspection Checklist

TOTAL OSHA CITATIONS FY2012

CITY OF ABBOTSFORD CONSOLIDATED PRIVATE SWIMMING POOL REGULATION BYLAW. Bylaw No AMENDMENTS

MATERIAL SAFETY DATA SHEET Orange Peel - Citrus Cleaner

CLEANING, INSPECTION, AND TESTING OF SEWERS

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

Vision Painting Inc Safety Management System

Notice of Unsafe or Unhealthful Working Conditions

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

MATERIAL SAFETY DATA SHEET

Mecklenburg County Health Ordinance Rules Governing Residential Swimming Pools

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

General Duty Clause. Section 112(r)(1) of CAA. Chris Rascher, EPA Region 1

MATERIAL SAFETY DATA SHEET 3M(TM) Specialty Tapes - Polyester Backing with Rubber Adhesive 10/13/2008

NORTHEAST COMMUNITY COLLEGE

U.N. Gen. Ass. Doc. A/CONF.164/37 (8 September 1995) < pdf?openelement>.

Post MD in Residence Placement

Material Safety and Data Sheet

MATERIAL SAFETY DATA SHEET

EMERGENCY PHONE: or (651) (24 hours)

Transcription:

Code(s) DOT 49 CFR 173.3: (c) Packages of hazardous materials that are damaged or found leaking and hazardous materials that have been spilled or leaked may be placed in a metal removable head salvage drum that is compatible with the lading and shipped for repackaging or disposal under the following conditions. (1) The drum utilized may be either a DOT specification or a non-dot specification drum as long as the drum has equal or greater structural integrity than a package that is authorized for the respective material in this sub-chapter. Maximum capacity shall not exceed 110 gallons. Code(s) EPA 40 CFR 264.175: (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section. (b) A containment system must be designed and operated as follows: (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination. Code(s) OSHA 29 CFR 1910.106 (e)(2)(iii): Separation and protection. Areas in which flammable or combustible liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided. Do you have drip pans under all drum faucets or leaks? Do you have large diameter funnels to transfer liquids into drums? Do you have drum covers to protect the integrity of drums stored outside as per 40 CFR 265.173? Code(s) Uniform Fire Code - Division IV, Section 80.402 (b)(2)(f): Dispensing and Use - Spill Control, Drainage Control, and Secondary Containment. Rooms or areas where hazardous material liquids are dispensed into containers exceeding a 1-gallon capacity or used in open containers or systems exceeding a 5-gallon capacity shall be provided with a means to control spills. Secondary containment shall be provided when the capacity of an individual container exceeds 55 gallons or the aggregate capacity of multiple containers exceeds 100 gallons.

OSHA Compliance The citations issued by OSHA compliance officers usually carry a penalty, depending on the severity of the violation. All penalties are assessed on the basis of the gravity of the violation, size of the business, good faith of the employer and the employer's history of previous violations. There are several types of OSHA violations that carry various penalties as follows: Other-Than-Serious Violations include situations that would affect safety or health, but would "probably not cause death or serious physical harm." OSHA can penalize employers up to $7,000. A group of other-than-serious violations may be treated as one serious violation. Serious Violations create a substantial probability that death or serious physical harm could result from a condition, practice, method, operation or process in a place of employment. OSHA will issue a citation unless the employer did not and could not have known about the violation. Serious violations carry a maximum penalty of $7,000. Willful Violations show evidence that the employer committed an intentional violation and carry a minimum penalty of $5,000 and a maximum penalty of $70,000. Criminal/Willful Violations occur when an employer willfully violates any standard and that violation in turn causes death to an employee. If this happens, the employer will be fined, upon conviction, not more than $10,000 or imprisoned for not more than six months, or both. Additional criminal penalties are imposed by the courts, not by OSHA. Repeated Violations occur when an employer fails to bring a previously cited condition into compliance. OSHA can issue a penalty of up to $70,000 to employers who repeatedly violate the OSHA Act. Specific standards which were cited by Federal OSHA inspectors during the period October 1997 through September 1998 as they relate to this compliance guide are as follows: OSHA Standard Number of Citations Number of Inspections Penalty Amount 1910.106 1155 669 $ 803,727 1926.152 267 183 $ 103,119 1910.106 Flammable and Combustible Liquids 1926.152 Flammables and Combustibles - Construction Code (NOTE: THIS DOES NOT INCLUDE CITATIONS AND PENALTIES ASSESSED BY STATE OSHA REGULATORS.) OSHA's average penalty for noncompliance is insignificant in comparison to the potential for multi-million dollar litigation concerning an injured or deceased employee. EPA Compliance One of EPA's most important responsibilities is ensuring compliance with federal laws that protect public health and safeguard the environment. Effective deterrence requires inspecting,

bringing penalty actions and securing compliance and remediation of harm. However, EPA realizes that achieving compliance also requires the cooperation of thousands of businesses and other regulated entities subject to these requirements. The EPA encourages regulated entities to voluntarily discover, disclose, correct and prevent violations of federal environmental law. As an incentive, the EPA eliminates or substantially reduces the gravity component of civil penalties and also does not recommend these cases for criminal prosecution. Repeat violations or those that result in harm or may present endangerment are not considered for relief, and companies are not allowed to gain economic advantage over competitors by delaying their investment in compliance. Corporations remain criminally liable for violations that result from conscious disregard of their legal obligations, and individuals are liable for criminal misconduct. Penalties EPA's enforcement program provides a strong incentive for responsible behavior by imposing stiff sanctions for noncompliance. Section 3008 of RCRA (Resource Conservation and Recovery Act) provides very serious civil and criminal penalties for violations. If EPA determines that any person is violating "any requirement" of Subtitle C (RCRA permit regulations), it may either issue an administrative order or commence a civil action against the alleged violator in federal district court. An administrative order issued by EPA under 3008 may impose penalties of up to $25,000 per day of noncompliance. EPA has developed a civil penalty policy that assists the government in calculating the appropriate penalty. The penalty calculation usually consists of three elements: (i) gravity of the infraction (potential for harm); (2) economic benefit from noncompliance (savings); and (3) any reasons, such as good faith or a history of compliance or noncompliance, to adjust the penalty up or down. In addition to civil penalties, 3008(d) establishes criminal penalties for individuals and corporations that knowingly violate any of the RCRA regulations pertaining to storing, treating, transporting, disposing of, or otherwise handling hazardous waste in violation of a permit or regulations issued by EPA. *A person convicted of any of these violations is subject to a fine of up to $50,000 per day or two years imprisonment, or both. Repeat offenders' penalties are doubled. *Any person who knowingly violates and "who knows at that time that he thereby places another person in imminent danger of death or serious bodily injury" is subject to a fine of $250,000 and imprisonment for up to 15 years, or both. If the violator is an organization, the fine can be up to $1,000,000. Although these EPA penalties are significant, they pale in comparison to the cost of a major clean-up of a hazardous material spill or the potential for litigation concerning harm to public health.

This is only a brief overview and should not be used as a substitute for the actual regulations. Many states have their own hazardous waste regulations based on the federal requirements. Some states have more stringent regulations than the federal program. When this is the case, you must comply with the state regulations. Uniform Fire Code - Division VIII, Section 79.803 (a) states: "Class I liquids shall not be run into containers unless the nozzle and containers are electrically interconnected. The provisions of this section shall be deemed to have been complied with where the metallic floor plates on which the container stands while filling are electrically connected to the fill stem or where the fill stem is bonded to the container during filling by means of a bond wire." OSHA 29 CFR 1910.106 (e)(2)(ii): Incidental storage or use of flammable and combustible liquids. Containers. Flammable or combustible liquids shall be stored in tanks or closed containers.. OSHA 29 CFR 1910.106 (a)(9): Closed container shall mean a container as herein defined, so sealed by means of a lid or other device that neither liquid or vapor will escape from it at ordinary temperatures. OSHA 29 CFR 1910.106 (e)(2)(iv)(a): Flammable liquids shall be kept in covered containers when not actually in use. Code(s) OSHA 29 CFR 1910.106 (a)(29): Safety Can shall mean an approved container, of not more than 5 gallons capacity, having a spring-closing lid and spout cover and so designed that it will safely relieve internal pressure when subjected to fire exposure. OSHA 29 CFR 1910.1030: The blood borne pathogens section applies to all occupational exposure to blood or other potentially infectious materials. OSHA 29 CFR 1910.1030 (d)(4): (A)Housekeeping. (i) General. Employers shall ensure that the worksite is maintained in a clean and sanitary condition. (g) Communication of hazards to employees. (1)(i)(A) Warning labels shall be affixed to containers of regulated waste, (B) Labels required by this section shall include the Biohazard symbol. (C) These labels shall be flourescent orange or orange-red, with lettering and symbols in contrasting color. OSHA 29 CFR 1910.106 (e)(2)(ii)(b): Incidental storage or use of flammable and combustible liquids.

(b) The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed: (1) 25 gallons of Class IA liquids in containers (2) 120 gallons of Class IB, IC, II, or III liquids in containers (3) 660 gallons of Class IB, IC, II, or III liquids in a single portable tank. OSHA 29 CFR 1910.106 (d)(3)(i&ii): Design, construction, and capacity of storage cabinets -(I)Maximum capacity. Not more than 60 gallons of Class I or Class II liquids, nor more than 120 gallons of Class III liquids may be stored in a storage cabinet. OSHA 29 CFR 1910.108 (f)(2): (2) Waste Cans. When waste or rags are used in connection with dipping operations, approved metal waste cans shall be provided and all impregnated rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily at the end of each shift. Eagle Safety Cans: Oily Waste Cans Butt Can OSHA 29 CFR 1910.106 (h)(8)(iii): Waste and residues. Combustible waste material and residues in a building or operating area shall be kept to a minimum, stored in closed metal waste cans, and disposed of daily. * Not more than 60 gallons may be Class I and Class II liquids. No more than 120 gallons of Class III liquids may be stored in a storage cabinet, according to OSHA 29 CFR 1910.106(d)(3) and NFPA 30 Section 4-3.1. Note: Not more than three such cabinets may be located in a single fire area, according to NFPA 30 Section 4-3.1. Uniform Fire Code 79.201: (g) Storage Cabinets. 1. General. When provisions of this code require that liquid containers be stored in storage cabinets, such cabinets, and storage shall be in accordance with this section. Cabinets shall be conspicuously labeled in red letters on contrasting background FLAMMABLE-KEEP FIRE AWAY. 2. Quantities. The quantity of Class I or Class II liquids shall not exceed 60 gallons and the total quantities of all liquids in a storage cabinet shall not exceed 120 gallons. 3. Construction. Cabinets may be constructed of wood or metal. Cabinets shall be listed or constructed in accordance with the following: A. Unlisted metal cabinets. Metal cabinets shall be of steel having a thickness of not less than 0.043 inch. The cabinet, including the door, shall be double walled with 1½-inch air space between the walls. Joints shall be riveted or welded and shall be tight fitting. Doors shall be well fitted, self-closing, and equipped with a latching device. The bottom of the cabinet shall be liquid-tight to a height of at least two inches.