For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Similar documents
For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Experiment 1 Use of Micropipettes: measuring volume accurately

MOLEBIO LAB #1: Microquantity Measurement

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Pipetting Small Volumes

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Gel Loading Practice MiniLab

Improving Pipetting Techniques

How to Use: 1. Hold the pipette like you are going to shake hands with it.

Pipetting and Determining Protein Concentration

Real World Metric System

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

How to Measure R7.1. Reference. I. Linear dimensions

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

A N F G J I C D D L A B C D E F

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Pipettor. User Manual

SOP-111 Pipetting Small Volumes

Other languages available on our website:

Operating Instructions. Rainin Classic Manual Pipette

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

RayPette Plus Autoclavable Pipette. User Manual

MULTICHANNEL. Labnet International, Inc.

A N B P F G J I C D D L A B C D E F

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

The pipettes cover a volume range from 0.1µl to 10ml.

Inquiry Module 1: Checking the calibration of a micropipette

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

A N B P G J I C D L D E

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Corning Step-R. Repeating Pipettor. Instruction Manual

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Loopamp Bovine Embryo Sexing Kit Instruction Manual

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Transferpette. Lightweight precise rugged reliable!

SoftGrip Single Channel Pipettes User Manual New Photo To Come

Transferpette. Lightweight precise rugged reliable!

PIPETMAN F ENGLISH. Other languages available on our website:

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

CHM250 Calibration and Measurement Lab. Balance Calibration

VOLUMETRIC TECHNIQUES

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

Lab Equipment ANALYTICAL BALANCE

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Technical Procedure for General Laboratory Equipment

CALIBRATION AND ADJUSTMENT

LABORATORY EXERCISE I METRIC SYSTEM OF MEASUREMENT

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Transferpette. Single and Multichannel Pipettes

Transferpette -8/-12

Patients Guide for Self Administering Intravenous Antibiotics General points

Varipette Operating manual

TITLE: DNA minitube - Red

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

VWR HIGH PERFORMANCE PIPETTOR

SOP for use of the SX19 Stopped-Flow Instrument

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Basic Flows in a Microfluidic Device

LABORATORY TECHNIQUES. Pouring Liquids

OXYTEMP Instructions 1

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

User s Guide VARIABLE VOLUME MODELS. Variable volume single and multichannel models and fixed volume models

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

WITOPET PREMIUM PIPETTE USER S GUIDE

Measuring Mass and Volume

User's Manual. Autoclavable Nichipet EX Plus Digital micro pipette for liquid handling CERTIFIED ISO9001

Before you start sampling, be sure to read

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

Title of Manual: Specimen Collection Document Number: GPA To provide the proper collection protocol for Candida Vaginitis testing.

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 42 Ultra-Sensitive Kit

3. Align ratchet drive with female insert on assembly, and raise ratchet handle until the ratchet drive is firmly seated into the assembly.

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 40 Ultra-Sensitive Kit

Installation of Your SprayMaster System

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

biosensis Mouse CXCL10/IP-10 ELISA Kit Protocol

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

Measurements. Metric System

Version BA D

The use of the analytical balance, and the buret.

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

Biological Activity Assay for Gibco Recombinant Proteins Chemotaxis Assay

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Tex-914-K, Calibrating Motorized Gyratory-Shear Molding Asphalt Press

Using the Akta Prime plus October 22, 2012

Transcription:

OXFORD 4 SIZES VERSION MEASURE FOR MEASURE MICROPIPETTING AND THE METRIC SYSTEM Concept: Work with DNA and enzymes frequently involves measuring very small volumes, often in the microliter range. A microliter (µl) is one millionth of a liter. Liquid measurements in the metric system are made in units based on the liter where a liter is about one quart. To make these precise measurements, molecular biologists use a precision tool known as a micropipet. This tool is as basic to their lab work as a hammer is to a carpenter. Micropipets come in many models and sizes. You will be using micropipets similar to those found in the Fred Hutchinson Cancer Research Center research labs. Objectives: In this lab, you will learn to use micropipets accurately and to measure volumes using metric units including microliters. Mastery of this technique is essential for good results in the activities to follow. Use the following information to calculate metric volume conversions. liter = ml (milliliters) ml =. liter liter =,, microliters microliter =. liter microliter = µl = (in lab jargon) lambda (λ) For accurate measurements and to prevent damage to the micropipets, follow these important guidelines: Set the volume only within the range of your micropipet. Have the proper size disposable tip in place on your micropipet before immersion into any solution. Always keep the micropipet in a vertical position when there is liquid in the tip. In a horizontal position, fluid can leak back into the piston. Use your thumb to control the speed at which the plunger rises after taking up or ejecting liquid. Letting the plunger snap back damages the piston and the volume dispensed may be inaccurate. group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM

SETTING AND PREPARING THE MICROPIPET There are four common sizes of micropipets. See the guide below for these sizes and volume ranges.. Choose a micropipet and set the volume by loosening the black lock lever, turning the thumb knob to set the volume and then gently tighten the lock lever. Make sure to recognize the decimal point for your micropipet (indicated by the in the table below) and to stay within the volume range.. Using the guide below, select the correct tip for your micropipet. Firmly push the end of the micropipet into the open end of the tip while the tip is still in the tip box. (Avoid twisting the micropipet as this can unscrew the shaft.) Lift the tip from the box, but don t touch the tip near the smaller end. Touching the tip contaminates it and will contaminate your samples. Refer to the Protocol Card for more information Oxford Micropipet and Tip Guide Size Range Top view and Color Example Setting Tip size and color Tip sample P-.- µl. white 6 6. µl micro white P- - µl yello 7 8 yellow 7.8 µl medium white or yellow P- - µl yellow µl P- - µl blue 6 7 67 µl or.67 ml decimal point large white or blue group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM

OPERATING THE MICROPIPET. Find the stops Hold the micropipet in your hand. Use your thumb to depress the plunger. Practice slowly depressing the plunger and feeling the two stops.. Draw some sample fluid from your microtube Push the plunger knob down to the first stop. Keeping the plunger down, lower the tip into the sample fluid just below the surface (~ to 3mm). Gradually release the plunger. Do this slowly to avoid sucking liquid inside the shaft of the pipet. After filling, wait second then remove tip from liquid. 3. Check the tip of the pipet See how much fluid you have. Make sure that there are no air bubbles trapped in the tip. If so, redraw the sample. Make sure that there are no drops clinging to the outside of the tip. 4. Release the fluid from the pipet Lower the tip into the microtube and lightly touch the side or bottom of the tube. Slowly depress the plunger to the first stop. Wait second, then push plunger to the second stop to expel the last bit of fluid so that the pipet tip has no fluid left in it. Keep the plunger pushed down as you take the pipet out of the tube, then slowly release the plunger.. 4 Eject the tip into a waste tip container by pushing the tip ejector button. Viscous fluids: If you are pipetting a liquid that is very thick or viscous (such as sample loading buffer or restriction enzymes--both contain glycerol or ficoll), it is especially important to insert the disposable tip just into the liquid that you are measuring (say mm). If you immerse the tip fully, large volumes of liquid will stick to the outside of the tip giving you a very inaccurate measurement. With viscous solutions, it is also important to move the plunger up and down slowly. Being able to do this makes you a real pro! group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM 3

MEASURE FOR MEASURE STUDENT WORKSHEET. Metric conversions: complete the following a. ml = microliters d. µl = ml b. microliters = ml e. µl = ml c. microliters = ml f. ml = µl. Put the following volumes in order from largest to smallest. a.. ml, µl,. ml,. µl,,, b. µl,. ml, µl,. ml,,, 3. Explain the reason for each of the following rules: a. Always use the micropipet within its designated range: b. Always use a disposable tip on a micropipet: c. Always hold a loaded micropipet in a vertical position: d. Always release the micropipet plunger slowly: 4. Under each micropipet, indicate the size of the micropipet, the set volume and the range for that micropipet (the first one is filled out as an example).. 3 Size (P-?) P- Volume: µl Range: µl group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM 4

. Select the appropriate micropipet and show what the dial should read to measure each of the following volumes: µl,. µl, 3 µl, and 7.3 µl. Also write the amount on the line beneath each drawing.. 6. Volume comparisons Practice measuring,,,,, and µl. On a piece of waxed paper or Parafilm release the drops and visually compare the sizes. Draw the actual size of each droplet on the chart below. (If you wet the lab table before setting the waxed paper down, the paper will not curl up as much.) Work on your technique. Be smooth. Try to pick up and dispense the same drop several times. µl. µl. µl. µl µl µl 7. Put one drop from an eyedropper or plastic transfer pipet on the piece of wax paper away from your other drops. Estimate its size in µl. group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM

8. Microcentrifuge instructions Close the caps on the tubes. The rotor must always be balanced you cannot, for example, insert only one tube into a microcentrifuge (microfuge). Spinning in an unbalanced arrangement like this would damage the motor of the instrument. Use an extra balance tube if necessary. After you have closed the lid of the centrifuge, give the tubes a -3 second spin. This will mix and pool all the reagents into a droplet in the bottom of each tube. Wait for the rotor to stop before opening the centrifuge lid. 9. Why is it important to balance a centrifuge before turning it on?. Show how you would arrange the given number of tubes in each centrifuge to balance the load. If you decide that you must add or remove tubes, explain. a. 3 tubes b. 4 tubes c. tubes d. tubes. Measurement Matrix Label three empty microtubes A, B, and C, with a permanent marker pen. Add solutions I, II, III, and IV to tubes A-C as shown in the matrix. To help you stay organized and prevent cross contamination, after pipetting each liquid place a check mark next to that space on your chart. Always use a new tip for each new liquid being added to the tubes or when adding a new liquid to a tube already containing some. Micropipet Matrix Tube Micropipet Solution I Solution II Solution III Solution IV Total A P-.8 µl 4. µl 3.7 µl B P- 3.4 µl.6 µl µl C P- µl 4 µl µl Spin the tubes in the microcentrifuge (microfuge) for a few seconds to pool the solutions. See centrifuge instructions in 8 above. As a check of your pipetting accuracy, do the following exercise. Set the P- to 9.6 µl. Slowly attempt to suck in all of the fluid in tube A. The contents should just fill the tip--no air space at the bottom of the tip, no leftover fluid in the tube. Repeat with tube B and the P- (total 8 µl) and with tube C and the P- (total 97 µl). OBSERVATION. What is the approximate volume of a microcentrifuge tube? µl e. tubes 3. If practice agarose gels are available: Load µl from tubes B and C and all of tube A into separate wells. How much fluid do the gel wells hold? Use an empty well to find out. You may flush out the wells and load them again for practice. group:*sep Files:*Uber SEP = Index:Kits:*Kits:Gel Kit :Measure for Measure:Oxford4_Student.doc 4//9 7:46 AM 6