Development of a high vacuum sample preparation system for helium mass spectrometer

Similar documents
Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Vacuum System at IUAC

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

The Principles of Vacuum Technology

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Major Design Features

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

The Experts in Vacuum Solutions

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Manual Solvent Purification System. Innovative Technology, Inc.

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Chapter 8: Cryo-sorption pumps

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Gases and welding distributors continue

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Series 203 Granville-Phillips Variable Leak Valve

Superconducting cyclotron and its vacuum system

GasTrak Pro TM Delivery/Control Systems

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Specifications of Cryogenic vacuum jacketed valves

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

Characterizing a Cu/Mn Alloy for Extracting Oxygen from Inert Gas. Streams

Procedure of Xenon Transfer

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Chapter 6 Leak detection

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Right-Angle Tube Roller Model

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Vacuum Jacketed Piping Solutions

Please refer F 90 of the present manual for the identification of the valves used in the detector.

Microscopy Cryogenic WORKSTATION. Performance by Design

Enrichment of helium from hydrothermal gases

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Matching Vacuum Pump to Process

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Optimizing Gas Supply for Industrial Lasers

GPP model GPPT model GPC model CLP model

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

DART-Bruker Vapur Interface Manual SI-410-A-R Rev 1-3

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Outgas of Methane from NEG Coating

The JET Gas Baking Plant for DT Operation and Analysis of Tritium Permeation and Baking Gas Activation in DTE1

Super-Clean Gas Filters from Restek

APPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY

CFD Analysis of the Anti-Surge Effects by Water Hammering

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Glove Box with Gas Purification System and Digital Control VGB-6. MTI Corporation

Description Advanced Features Typical Applications

SINGULUS TECHNOLOGIES

Practical approach and problems in in-situ RGA calibration

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

How To Use Getters and Getter Pumps

The Helium Leak Detector

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Total Pressure Measurement Using Residual Gas Analyzers

NGN Series nitrogen generator

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

RD(H)20/25 Pressure-Reducing Regulator User Manual

End of Chapter Exercises

v. Size shall be specified on drawings.

PRELIMINARY TEST RESULTS ON A CLOSED-LOOP CONTAMINANT REMOVAL SYSTEM FOR PROCESSING OF METALLIC MELTS

SNS BL-13B NPDGamma Experiment

LEAK-TIGHT WELDING EXPERIENCE FROM THE INDUSTRIAL ASSEMBLY OF THE LHC CRYOSTATS AT CERN

Basic & Controlled Atmosphere Glove Boxes

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Specification Sheet. Equipment Model: J-VAC-12 High Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

1 Design of the Portable mass spectrometric sensor for vascular and endocrine disease diagnostics

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Ultrahigh Vacuum in Superconducting Synchrotrons A.Smirnov, JINR, Dubna, Russia

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Vacuum Systems Operation EiC Training and Refresher Course 26 th April 2007

The Gas Attenuator of FLASH

Under pressure pushing down

Zebron Gas Management

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

High Performance Mass Spectrometers

Tank Blanketing Pressure Regulators RHPS Series

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

at NIST: ultra-low outgassing rates

Two-stage pulse tube refrigerator with step displacer as phase shifter

Transcription:

Journal of Physics: Conference Series Development of a high vacuum sample preparation system for helium mass spectrometer To cite this article: P Kumar et al 2012 J. Phys.: Conf. Ser. 390 012056 View the article online for updates and enhancements. Related content - Vacuum System at IUAC A Mandal - Spinning rotor gauge based vacuum gauge calibration system at the Institute for Plasma Research (IPR) Pratibha Semwal, Ziauddin Khan, Kalpesh R Dhanani et al. - Removal of water from unbaked vacuum system G Pal, R C Yadav, J Akhter et al. This content was downloaded from IP address 148.251.232.83 on 30/04/2018 at 02:47

Development of a high vacuum sample preparation system for helium mass spectrometer P Kumar, N K Das, C Mallik and R K Bhandari Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700064 Email: pradeep_vecc@yahoo.co.in Abstract. A high vacuum sample preparation system for the 3 He/ 4 He ratio mass spectrometer (Helix SFT) has been developed to remove all the gaseous constituents excluding helium from the field gases. The sample preparation system comprises of turbo molecular pump, ion pump, zirconium getter, pipettes and vacuum gauges with controller. All these are fitted with cylindrical SS chamber using all metal valves. The field samples are initially treated with activated charcoal trap immersed in liquid nitrogen to cutoff major impurities and moisture present in the sample gas. A sample of 5 ml is collected out of this stage at a pressure of 10-2 mbar. This sample is subsequently purified at a reduced pressure of 10-7 mbar before it is injected into the ion source of the mass spectrometer. The sample pressure was maintained below 10-7 mbar with turbo molecular vacuum pumps and ion pumps. The sample gas passes through several getter elements and a cold finger with the help of manual high vacuum valves before it is fed to the mass spectrometer. Thus the high vacuum sample preparation system introduces completely clean, dry and refined helium sample to the mass spectrometer for best possible analysis of isotopic ratio of helium. 1. Introduction The 3 He/ 4 He ratio provides useful information on the origin of helium (primordial or radiogenic). It is also an important indicator to the study of magmatic volatiles [1]. The most vital part of any mass spectrometric analysis is the sample preparation. Several sample extraction and cleaning techniques [2][3] have been used for helium isotopic analysis using high vacuum sampling systems. The mass spectrometer requires completely clean and dry samples at a pressure lower than 10-7 mbar for precise measurements. Helium bearing gas samples collected at atmospheric pressure from different geothermal field stations contains impurities like N 2, O 2, Ar, CH 4 etc. This paper describes the fabrication, design and operational details of cleaning of field samples at a vacuum of the order of 10-7 mbar for helium isotope analysis. 2. Design, Fabrication and Operation The sample preparation system is fabricated with all stainless steel components (316L) and cleaned prior to use on the system. The cleaning is done by boiling the fabricated parts in 5% HNO 3 followed by cleaning with acetone and alcohol followed by drying. Conflate flanges with OFHC copper gasket are used to assemble various components of the sample preparation system. Published under licence by IOP Publishing Ltd 1

2.1 The Pretreatment stage The samples are collected from geothermal field stations in pre evacuated stainless steel sampling cylinders (500 cc, double ended) for analysis. These sample gases were first treated with liquid nitrogen cooled activated charcoal trap for removal of most of the impurities like moisture, nitrogen, oxygen, hydrocarbons and argon. The schematic of the assembly of the charcoal trap is shown in figure 1. Fig. 1. Schematic of pretreatment stage charcoal trap assembly. The pre treatment stage consists of two turbo molecular vacuum pumps along with two charcoal traps with interconnected tubings, valves and vacuum gauges. All the interconnected tubings are ¼ SS tubes and the valves are Swagelok SS 4L valves. The vacuum gauges used are compact full range gauges (Pfeiffer). Sample collected from the pretreatment stage in a cylinder that was evacuated to a vacuum level of 10-6 mbar using TMP 2 with V8, V9 and V10 valves open. The charcoal traps were first evacuated to a vacuum level of 10-5 mbar with use of TMP 1 and V4, V5 and V6 open. While evacuating the charcoal traps V3 and V7 are kept closed. When the vacuum level in the charcoal traps reached to the desired level, liquid nitrogen was poured to the containers followed by closing of V4 and V6. Valve V5 was kept close and sampling bottle (S2) is evacuated to 10-6 mbar. After a time of about 10 minutes allowed for cooling the charcoals, valve V2 and V3 and V5 are opened and the field sample was allowed to pass through the first trap and vacuum decreases. After few minutes valve V6 was opened to allow the sample gas to pass the second charcoal trap. With liquid nitrogen cooled charcoal, most of the impurities like moisture, nitrogen, oxygen, hydrocarbons present in the sample get trapped up on the charcoal leaving relatively pure helium sample. At this stage vacuum inside the charcoal trap was of the order of few mille-bar. After done this valve V7 and V8 was opened while V9 and V10 were kept closed and the helium sample was collected in a 5 ml SS sample cylinder for further cleaning. 5 ml of the relatively pure helium sample was collected at a vacuum pressure of 10-2 mbar from the pretreatment stage. 2.2 The Sample Preparation system Figure 2 shows the schematics of the high vacuum sample preparation system. The interconnecting vacuum tubes are fabricated from ¾ SS pipes. The whole system is assembled on a table top for easy access and operation. 2

Fig. 2. Schematic of sample preparation system The sample preparation system is an all metal high vacuum system consists of the following components: 1: Turbo-molecular drag vacuum pump (Pfeiffer, 60 l/s) with two stage diaphragm backing pump 2: StarCell Ion pump (Varian, 20l/s) for clean vacuum 3: SAES NP10 zirconium getter pumps (Zr 84 wt%, Al 16 wt%) in jackets that can be water cooled 4) Ultra low volume micro ion gauge (Granville Phillips) 5: Liquid nitrogen cooled cold finger (0.5 dia, 4 long) 6: All metal UHV valves (Varian) 7: SS manifold (volume 355 cc). The turbo molecular drag pump has a DN63CF inlet port and the ion pump has a DN40CF inlet port. The all metal valves have DN16CF connections. The pumps, gauges, cold finger were connected to the SS manifold using the all metal valves. The total volume of the gas preparation line including the getters is 355 cc. There are two inlets lines to enable admission of the sample gas to final clean up line. Each of the inlets are pumped by turbo molecular pump backed by diaphragm pump and are fitted with NP10 getter pump. Sample from the pretreatment stage collected at a pressure of 10-2 mbar and expanded in a 1000 cc SS cylinder. The cylinder was first evacuated using a turbo molecular pump to a vacuum pressure 10-7 mbar and isolated from the pump by closing valve V19. The vacuum pressure was monitored using a pirani vacuum gauge. The sample gas from the 5 ml cylinder transferred to the 1000 cc cylinder by opening valve V18 and allowed to expand and the sample gas pressure decreases from 10-2 mbar to 0.5 X 10-4 mbar. Helium sample from the 1000cc cylinder at a pressure 10-4 bar was introduced through one of the inlet port using a 0.1 cc pipette with valve V16 open. The sample gas exposed to the four getters, the ion pump and the cold finger at a vacuum pressure of 10-8 mbar via opened valves V1, V4, V11 and V17. Since the internal volume of the sampling system including the getters is 355 cc the pressure will reach to 1 X 10-6 mbar. At this time the turbo pump was isolated from the manifold via closed valves V2, V10 and V14. Expansion of 0.1 cc of the sample in the manifold occurs and pressure of the sample gas drops to 1 X 10-6 mbar. Sample gas at a pressure of 10-6 mbar is not suitable to inject into the mass spectrometer. The valve V9 was closed to trap the sample in two getters (volume 103 cc) and the remaining manifold was evacuated by opening valve V2, V10 and V17 by turbo pump. Again on improvement of vacuum pressure to an order of 10-8 mbar, the turbo pumps are then isolated from the manifold and V9 was opened to expand the trapped sample gas further. By this time the sample gas pressure further drops to 2 X 10-7 3

mbar. As the sample gas exposed to the four getter pumps remaining active gases are caught in to it. With the cold finger the remaining moisture etc. are cleaned up. At this stage the sample gas in the gas preparation system is ready for inject into the mass spectrometer for analysis. The mass spectrometers flight tube with inlet pipe has a volume of 1275 cc. and kept at a vacuum of 10-9 mbar. With opening of the inlet valve V3 sample get injected to the mass spectrometer. Prior to injection of the sample; turbo pump, ion pump, cold finger and the getters are isolated from the manifold with closing respective valves. The injected sample expands into the mass spectrometer and final vacuum pressure during analysis was of the order 5 X 10-8 mbar. Figure 3 shows the enlarged view of the sample preparation system along with the assembly with the mass spectrometer. Figure 4 illustrates the relative intensities of helium - 3 and helium - 4 of air sample analyzed with the mass spectrometer. Fig. 3. The sample preparation system Fig. 4. Intensity of helium -3 and Helium -4 in air sample 4

3. Conclusion Several helium samples collected from various geothermal fields in West Bengal, Jharkhand, Bihar and Odisha were analyzed successfully for helium isotope ratio. The developed sample preparation system is efficient to deliver clean samples of helium at a suitable vacuum pressure for representative isotopic ratio analysis. Acknowledgement We are thankful to Department of Atomic Energy, Government of India, for supporting this research work. References [1] Das N K, Ghose D, Bhandari R K, Sen P and Sinha B 2009 Current Science 96 pp 1031-1032 [2] Beyerle U, Hertig W A, Imboden D M, Baur H, Graf T and Kipfer R 2000 Environ. Sci. Technol. 34 pp 2042-2050 [3] Jenkins W J, Lott D E, Cahill K, Curtice J and Landry P 2010 The Go-Ship Repeat Hydrology Manual: A Collection of Expert Reports and Guidelines 134 14 5