Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Similar documents
Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Pipetting Small Volumes

Improving Pipetting Techniques

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Pipettor. User Manual

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

RayPette Plus Autoclavable Pipette. User Manual

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

The pipettes cover a volume range from 0.1µl to 10ml.

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Standard Operating Procedure. Air Displacement Pipette Calibration

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

MULTICHANNEL. Labnet International, Inc.

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Varipette Operating manual

Exeter Clinical and Health Research

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Register your instrument! Eppendorf Research plus. User Adjustment

Technical Procedure for General Laboratory Equipment

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Transferpette -8/-12

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Gel Loading Practice MiniLab

Operating Instructions. Rainin Classic Manual Pipette

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

VITLAB micropipette. Standard Operating Procedure (SOP)

Pipetting and Determining Protein Concentration

PIPETMAN F ENGLISH. Other languages available on our website:

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

Other languages available on our website:

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

University of Saskatchewan Department of Mechanical Engineering Standard Operating Procedure # Mat0002

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

SoftGrip Single Channel Pipettes User Manual New Photo To Come

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Exeter Clinical and Health Research

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

UNIVERSITY OF ROCHESTER MEDICAL CENTER

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Laboratory Safety Training. Environmental Health and Safety

SOP-111 Pipetting Small Volumes

Real World Metric System

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

MOLEBIO LAB #1: Microquantity Measurement

Standard Operating Procedure (SOP)

Biosafety Containment Level 2

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Decontamination Procedures for Gilson Pipettes

1. The laboratory supervisor must enforce the institutional policies that control access to the laboratory.

Liquidator 96 Manual benchtop pipetting system

Corning Step-R. Repeating Pipettor. Instruction Manual

VWR HIGH PERFORMANCE PIPETTOR

A N F G J I C D D L A B C D E F

A N B P F G J I C D D L A B C D E F

CALIBRATION AND ADJUSTMENT

Use of Biosafety II cabinets

Tacta Mechanical Pipette User Manual

Photolithography. Operating Instructions

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

Vertebrate Animal Biosafety Level 1 Criteria

Post MD in Residence Placement

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

Determination of Sodium using Atomic Emission

Standard Operating Procedures (v9 5/1/17)

ali-q TM Gravimetric Verification Procedure

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Biological Safety Cabinet Guidelines

Loopamp Bovine Embryo Sexing Kit Instruction Manual

Inquiry Module 1: Checking the calibration of a micropipette

Proline Plus Mechanical Pipette

STANDARD OPERATING PROCEDURE FOR MAINTENANCE AND CLEANING OF PULMONARY FUNCTION LABORATORY AND EQUIPMENT

CCM Approval: IACUC Approval:

PURPOSE: LEVEL: Interdependent Principal Investigator/designee Biological Specimen Repository Staff SUPPLIES: CATALOG NUMBER

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Working Safely with Hydrofluoric Acid

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

WITOPET PREMIUM PIPETTE USER S GUIDE

The pipette of Choice for Problem Liquids!

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Transcription:

Standard Operating Procedure Pipettes SOP Number: SOP-P-01 Category: Lab Equipment Supersedes: N/A Effective Date: December 1, 2017 Pages 5 Subject: Pipettes Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy 1.0 POLICY This standard operating procedure (SOP) describes the proper pipetting technique to reduce the generation of aerosols while working in the W.J. Henderson Centre for Patient- Oriented Research (WJHCPOR). 2.0 PURPOSE To ensure that all users of the WJHCPOR can safely use the pipettes to manipulate potentially infectious biospecimens and reduce the risk of infection. 3.0 DEFINITIONS Aspirate - to draw liquid up into the pipette tip. Blow Out - the piston moves to the lowest position in order to blow out the residual liquid from the pipette tip. During pipetting operations, the liquid from the blow out is part of the dispensing volume. Dispense - to discharge the liquid from the tip Version 1 (December 1, 2017) - 1 SOP-P-01

4.0 RESPONSIBILITY Users are responsible for: Attending orientation and training on the use of pipettes prior to use. Taking proper care of the pipettes according to specified use guidelines as set out by this SOP and the manufacturer. Reading and following all instructions for usage and maintenance of the pipettes. Selecting the appropriate pipette and disposable tips for the research protocol in use. NOTE: IF AT ANY TIME YOU ARE UNSURE HOW TO USE THE PIPETTES SAFELY, PLEASE REFER TO THE INSTRUCTION MANUAL FOR FURTHER DETAILS AND/OR ASK THE DESIGNATED KGHRI STAFF MEMBER FOR ASSISTANCE. Reporting any damage to the pipettes to the designated KGHRI staff member immediately so repairs can be made. Wearing appropriate PPE (lab coat, safety glasses, and gloves) when using the pipettes. ALWAYS pipetting in the biological safety cabinet (BSC). ALWAYS disposing of the pipette tips (or disposable pipettes) in the appropriate biological waste container. ALWAYS wiping down the pipettes with an Oxivir wipe after use. KGHRI is responsible for: Training new users in safe usage of the pipettes, documenting the training of all users, and ensuring users are proficient in performing the steps of this SOP. Ensuring all copies of user instructions for the pipettes is readily available to all users. Ensuring all pipettes used are in good repair, calibrated and decontaminated prior to repair/calibration. Ensuring that all the regular and periodic maintenance required is carried out and recorded in the Maintenance Log. Ensuring the records of repair is kept and available for inspection. Providing Oxivir wipes for users of the WJHCPOR. Version 1 (December 1, 2017) - 2 SOP-P-01

5.0 PROCEDURES 5.1 Setting the Volume Turn the volume adjustment ring as depicted in the image below to adjust the volume. The height of the control button changes as the volume is adjusted. The numbers on the volume display are to be read from the top to the bottom. The decimal places are below the hyphen. The volume is displayed in μl. The BLUE pipette volumes are 100 to 1000 μl. The YELLOW pipette volumes are 10 to 100 μl. Adjust the volume setting from a higher value to a lower value. If required, turn beyond the required value and then back again. 5.2 Using Pipette Tips The pipette is only functional if a disposable pipette tip is attached. The colour of the control button matches the colour of the eptips tray (blue or yellow) that you need. Fit the suitable pipette tip on the tip cone, applying light pressure (see image below). Version 1 (December 1, 2017) - 3 SOP-P-01

5.3 Aspirating Liquid Step 1: Step 2: Step 3: Step 4: Step 5: Press down the control button to the 1 st stop Always aspirate sample in the vertical position (approximately 4 mm into the liquid). To aspirate the liquid, allow the control button to slide back slowly. Maintain the immersion depth, so that no air is aspirated accidentally. In the case of large volumes: before removing the pipette tip from the liquid, wait approximately 3 seconds. To ensure maximum precision and accuracy, wet each new tip initially by aspirating and dispensing the liquid one to three times. Only then should pipetting commence. Remove the tip slowly from the liquid. Wipe the tip slowly against the tube wall to ensure that no outer wetting remains on the tip. Place the tip on the tube/cryovial wall at an angle. Press the control button slowly until the first stop and wait until the flow of liquid stops. Pause, and then press the control button until the 2 nd stop to eject (blow out) remaining liquid. To eject the tip, press the tip ejector mechanism. Eject tip carefully into the proper biological waste container. A new disposable tip should be used between each specimen tube to prevent contamination. Version 1 (December 1, 2017) - 4 SOP-P-01

6.0 REFERENCES The Instruction Manual for the Pipettes (Eppendorf Research Plus Operating Manual; same manual for each pipette) is located in the Research Centrifuge Room (Connell 4, Room 2-4-041) in the binder on the shelf above the centrifuges. 7.0 CONTACTS Research Administration Facilitator (Designated KGHRI Staff Member): Lisa McAvoy Kingston General Health Research Institute W.J. Henderson Centre for Patient Oriented Research Connell 4, Kingston Health Science Centre (KGH Campus) Kingston, Ontario K7L 2V7 613-549-6666 ext. 3344 mcavoye1@kgh.kari.net Director, Health Sciences Research: Veronica Harris-McAllister Kingston General Health Research Institute W.J. Henderson Centre for Patient Oriented Research Connell 4, Kingston Health Science Centre (KGH Campus) Kingston, Ontario K7L 2V7 613-549-6666 ext. 3653 harrismv@kgh.kari.net 8.0 SOP HISTORY SOP Number Date Issued Summary of Revisions SOP-P-01 01-DEC-2017 Original version. Version 1 (December 1, 2017) - 5 SOP-P-01