Flow pattern, pressure drop and void fraction of two-phase gas liquid flow in an inclined narrow annular channel

Similar documents
Experimental Analysis and CFD Simulation of Pressure Drop of Carbon Dioxide in Horizontal Micro Tube Heat Exchangers

Numerical Analysis of Two Phase Flow Patterns in Vertical and Horizontal Pipes

Flow in a shock tube

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

The effect of tube diameter on vertical two-phase flow regimes in small tubes

Effect of 180 bends on gas/liquid flows in vertical upward and downward pipes

Flow transients in multiphase pipelines

The Discussion of this exercise covers the following points:

Irrigation &Hydraulics Department lb / ft to kg/lit.

Section 2 Multiphase Flow, Flowing Well Performance

Flow and Mixing in the Liquid between Bubbles

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

THE EFFECTS OF INLET FLOW CONDITIONS ON GAS-LIQUID TWO-PHASE FLOW IN A MICRO TUBE. Yuji Suzuki Dept. of Mech. Eng., The univ.

Experiment 8: Minor Losses

Measurement of both gas and liquid velocity profiles for bubble-induced turbulent flow

Bioreactor System ERT 314. Sidang /2011

Air entrainment in Dip coating under vacuum

Two-phase Flow Across Small Diameter Split U-type Junctions

Gas-liquid two-phase flow in a downward facing open channel

Free Surface Flow Simulation with ACUSIM in the Water Industry

EFFECTS OF CHANNEL INCLINATION ON TWO-PHASE FLOW CHARACTERISTICS FOR SMALL DIAMETER CHANNELS

A model for the bubble lift-off diameter in subcooled boiling flow in a horizontal channel

Cover Page for Lab Report Group Portion. Head Losses in Pipes

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1

PRESSURE DROP AND FLOW BEHAVIOUR OF REFRIGERANT TWO PHASE FLOW IN A SMOOTH HAIRPIN

A REVIEW OF T-JUNCTION GEOMETRICAL EFFECT ON TWO-PHASE SEPARATION

Visualization and research of gas-liquid two phase flow structures in cylindrical channel

Two Phase Flow Measurement and CFD Analysis in an Air lift loop

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Development of High-speed Gas Dissolution Device

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Akasison Flow phenomena of a siphonic roof outlet

Heat Pump Connections and Interior Piping

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

Flow assurance in Oil-Gas Pipelines

A Study on the Effects of Wind on the Drift Loss of a Cooling Tower

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Multiphase Flow Prof. Gargi Das Department of Chemical Engineering Indian Institute of Technology, Kharagpur

PHYS 101 Previous Exam Problems

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

Modeling pressure drop of two-phase gas/liquid flow in PEM fuel cell channels

CFD SIMULATIONS IN AN INTERNAL CIRCULATION AIRLIFT OPERATING UNDER HOMOGENEOUS REGIME

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Two Phase Fluid Flow (ENGINEERING DESIGN GUIDELINE)

Cover Page for Lab Report Group Portion. Drag on Spheres

Student name: + is valid for C =. The vorticity

! =! [4 (2) ! n] 16 th Australasian Fluid Mechanics Conference Crown Plaza, Gold Coast, Australia 2-7 December 2007

World Academy of Science, Engineering and Technology International Journal of Chemical and Molecular Engineering Vol:7, No:12, 2013

STUDY OF SLUG CONTROL TECHNIQUES IN PIPELINE SYSTEMS

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Wet Gas Flowmetering Guideline

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

An Experimental Performance Study of Vortex Tube Refrigeration System

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Fluid-Structure Interaction Analysis of a Flow Control Device

Simulation of Gas Holdup in a Bubble Column with a Draft Tube for Gas Dispersion into an Annulus

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

Experimental Investigation of CCFL in Pressurizer Surge Line with Air-Water

Performance Characteristics of Airlift Pumps with Vortex Induced by Tangential Fluid Injection

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

Comparison of MARS-KS to SPACE for counter current flow limitation model

Application of a borescope to studies of gas liquid flow in downward inclined pipes

STUDY OF TWO AND THREE-PHASE FLOWS IN LARGE DLAMETER HORIZONTAL PIPELINES. The Faculty of the

B. C. Houchens, F. Popa & A. Filippov. Abstract. 1 Introduction. Landmark, Halliburton, USA

Experimental studies on the effect of the number of stages on the performance of an electrical submersible pump in two-phase flow conditions

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Universities of Leeds, Sheffield and York

Applied Fluid Mechanics

EFFECT OF CORNER CUTOFFS ON FLOW CHARACTERISTICS AROUND A SQUARE CYLINDER

Environmental Science: An Indian Journal

Two phase discharge flow prediction in safety valves

Visual analysis of flow boiling at different gravity levels in 4.0 mm tube

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

By Syed Ahmed Amin Shah 4 th semester Class No 8 Submitted To Engr. Saeed Ahmed

Workshop 1: Bubbly Flow in a Rectangular Bubble Column. Multiphase Flow Modeling In ANSYS CFX Release ANSYS, Inc. WS1-1 Release 14.

EWGAE 2010 Vienna, 8th to 10th September

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Laboratory studies of water column separation

AIR FRACTIONS IMPACT OVER PRESSURE DROP IN AIR- WATER MIXTURE FLOW

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Third measurement MEASUREMENT OF PRESSURE

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

EXPERIMENTAL INVESTIGATION OF LIQUID HOLDUP IN HORIZONTAL TWO- PHASE ANNULAR FLOW USING CONSTANT ELECTRIC CURRENT METHOD (CECM)

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Lab. Manual. Fluid Mechanics. The Department of Civil and Architectural Engineering

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

FORMATION AND DEVELOPMENT OF SUBMERGED AIR JETS

Transcription:

Experimental Thermal and Fluid Science 30 (2006) 345 354 www.elsevier.com/locate/etfs Flow pattern, pressure drop and void fraction of two-phase gas liquid flow in an inclined narrow annular channel Somchai Wongwises *, Manop Pipathattakul Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab (FUTURE), Department of Mechanical Engineering, King Mongkut s University of Technology Thonburi, Bangmod, Bangkok 10140, Thailand Received 1 July 2005; accepted 16 August 2005 Abstract Two-phase flow pattern, pressure drop and void fraction in horizontal and inclined upward air water two-phase flow in a mini-gap annular channel are experimentally studied. A concentric annular test section at the length of 880 mm with an outer diameter of 12.5 mm and inner diameter of 8 mm is used in the experiments. The flow phenomena, which are plug flow, slug flow, annular flow, annular/slug flow, bubbly/plug flow, bubbly/slug plug flow, churn flow, dispersed bubbly flow and slug/bubbly flow, are observed and recorded by high-speed camera. A slug flow pattern is found only in the horizontal channel while slug/bubbly flow patterns are observed only in inclined channels. When the inclination angle is increased, the onset of transition from the plug flow region to the slug flow region (for the horizontal channel) and from the plug flow region to slug/bubbly flow region (for inclined channels) shift to a lower value of superficial air velocity. Small shifts are found for the transition line between the dispersed bubbly flow and the bubbly/plug flow, the bubbly/plug flow and the bubbly/slug plug flow, and the bubbly/plug flow and the plug flow. The rest of the transition lines shift to a higher value of superficial air velocity. Considering the effect of flow pattern on the pressure drop in the horizontal tube at low liquid velocity, the occurrence of slug flow stops the rise of pressure drop for a short while, before rising again after the air velocity has increased. However, the pressure does not rise abruptly in the tubes with h =30 and 60 when the slug/bubbly flow occurs. At low gas and liquid velocity, the pressure drop increases, when the inclination angles changes from horizontal to 30 and 60. Void fraction increases with increasing gas velocity and decreases with increasing liquid velocity. After increasing the inclination angle from horizontal to h = 30 and 60, the void fraction appears to be similar, with a decreasing trend when the inclination angle increases. Ó 2005 Elsevier Inc. All rights reserved. Keywords: Two-phase flow; Mini-channel; Narrow annular channel; Flow pattern; Pressure drop; Void fraction 1. Introduction * Corresponding author. Tel.: +662 470 9115; fax: +662 470 9111. E-mail address: somchai.won@kmutt.ac.th (S. Wongwises). Two-phase gas liquid flow through a confined gap is encountered in several engineering applications including boiling behavior in minichannels, cooling systems of various types of equipment such as high performance microelectronics, supercomputers, high-powered lasers, medical devices, high heat-flux compact heat exchangers in spacecraft and satellites etc. It can be expected that the restriction of the bubble space in the minichannel is the cause of the differences in the two-phase flow characteristics from those in conventional channel geometries. This may also affect heat-mass transfer characteristics during the change of phase. It is not possible to understand the two-phase flow phenomena without a clear understanding of the flow patterns encountered. It is expected that the flow patterns will influence the two-phase pressure drop, holdup, system stability, exchange rates of momentum, heat and mass during the phase-change heat transfer processes. The ability to accurately predict the type of flow is necessary before relevant calculation techniques can be developed. 0894-1777/$ - see front matter Ó 2005 Elsevier Inc. All rights reserved. doi:10.1016/j.expthermflusci.2005.08.002

346 S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 Two-phase flow patterns in small circular tubes have been studied by a number of researchers while those in mini non-circular channels have received comparatively little attention in literature. Zhao and Rezkallah [1] proposed the phasic Weber as system parameters to elucidate the effects of inertia and surface tension in micro-channels at micro-gravity. Their flow regime map was divided into three zones: surface tension-dominated zone (bubbly and slug flow regimes), inertia-dominated zone (annular flow regime), and the transition zone. Wilmarth and Ishii [2,3] observed the flow patterns and measured the void fraction and the interfacial area concentration of adiabatic co-current vertical and horizontal air water flow in narrow rectangular channels with gaps of 1 and 2 mm. The developed flow regime maps were compared with those obtained for a round pipe. Bonjour and Lallemand [4] performed experiments to elucidate the flow regimes of natural convective boiling of R113 in upward two-phase flow in vertical narrow rectangular channels with gap sizes ranging between 0.5 and 2 mm. Three flow boiling regimes, namely nucleate boiling with isolated deformed bubbles, nucleate boiling with coalesced bubbles, and partial dry out, were observed. A new flow regime map based on the Bond number and a ratio of the heat flux to the critical heat flux was developed to confine the boiling. Xu et al. [5,6] investigated an adiabatic co-current vertical two-phase flow of air and water in vertical rectangular channels (12 260 mm) with narrow gaps of 0.3, 0.6 and 1.0 mm. Flow patterns for gaps of 0.6 and 1.0 mm were similar to those reported in the literature. By decreasing the channel gaps, the transition from one flow regime to another appeared at a lower gas velocity. However, for the gaps of 0.3 mm, even at very low gas flow rates, bubbly flow was never found. Hibiki and Mishima [7] developed a mathematical model to predict the flow regime transition for vertical upward flows in narrow rectangular channels. The model was based on that of Mishima and Ishii [8] for vertical upward two-phase flows in round tubes. The developed model was compared with the measured data of air water flows in rectangular channels with gaps of 0.3 17 mm. Zhao and Bi [9] conducted experiments to visualize the co-current upward air water two-phase flow patterns in vertical equilateral triangular channels with hydraulic diameters of 0.866 mm, 1.443 mm and 2.886 mm. The observed flow patterns obtained from the larger hydraulic diameters (1.443 mm and 2.886 mm) were found to be similar to those obtained from conventional, large-sized vertical circular tubes. For the smallest channel (0.866 mm), the dispersed bubbly flow pattern was not found. Akbar et al. [10] compared the measured data reported in open literature with a Weber number-based two-phase flow regime map which was previously developed by Zhao and Rezkallah [1], and Rezkallah [11]. Balasubramanian and Kandlikar [12] used high speed photography for the observation of flow behaviors (nucleate boiling, slug formation, dryout, reverse flow and flow at the exit manifold) during flow boiling of water in a single rectangular minichannel. Satitchaicharoen and Wongwises [13] studied the flow patterns of vertical upward gas liquid two-phase flow in mini-gap rectangular channels. The effects of gap size, channel width and liquid viscosity on the flow pattern transitions were examined. There are some studies dealing with two-phase flow in annuli. Lahey and Ohkawa [14] used the gamma-ray attenuation technique to determine local void fractions of different kinds of gas liquid flow patterns in vertical annular channels. Kelessidis and Dukler [15] performed vertical upward air water two-phase flow experiments in a vertical annuli (D i = 50.8 mm, D o = 76.2 mm). Bubbly, slug, churn, annular and annular-with-lumps flow patterns were observed in their experiments. Osamasali and Chang [16] conducted air water two-phase flow experiments in horizontal annuli with D i = 50.8 mm at various outer diameters (D o = 135.4, 101.6 and 81.9 mm). They could identify five common flow patterns: smooth, wavy, plug, slug and annular. In their experiment, D i /D o ratios slightly affected the flow regime transition. Ekberg et al. [17] conducted an experiment on twophase flow in narrow channels of horizontal 430 mm-long concentric annular tubes, with inner diameter of outer tube and outer diameter of inner tube of 8.6 6.6 mm and 35.2 33.2 mm, respectively. Air water was used as the tested fluid, with superficial velocity of air and water within the ranges of 0.02 57 m/s and 0.1 6.1 m/s, respectively. Flow pattern, void fraction and pressure drop within the 250 mm range were investigated. The flow patterns found were slug/plug, stratified-slug, stratified, annular-slug, bubbly-plug, dispersed bubbly, and churn. The stratified flow pattern was not evident in small tube, but it was believed to occur at low air and water flow rates which was not covered in this experiment. A quick valve-closing method was used to find the value of void fraction occurred in the channel from the level of water stored between two valves. The pressure drop was measured within the length of 250 mm using differential pressure transducer. Up to now, there has been only one work, carried out by Ekberg et al. dealing with two-phase flow in narrow annuli. However, it can be noted that their study concentrated on horizontal flow and no attention was paid to the effects of inclination angles. In the present study, the main objective is to obtain and clarify the characteristics of flow pattern, pressure drop and void fraction in inclined upward co-current gas liquid two-phase flow in a narrow annular channel. The effect of inclination angle on the flow patterns, flow pattern maps, pressure drop and void fraction, which have never before appeared in open literature, are presented. 2. Experimental apparatus and procedure The schematic diagram of the experimental apparatus is shown in Fig. 1. The main components of the system con-

S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 347 1 2 3 Temperature digital display Air flowmeter Mixing chamber P P PT DT Water flow meter θ Test section Air Water 45 o. 150 mm. Plastic tube 18 mm. Plastic tube 6 mm. Air compressor P = Valve = Pressure gauge Air tank Air pressure regulator PT DT Water Water pump = Pressure transducer = Differential pressure transducer Fig. 1. Schematic diagram of the experimental apparatus. Todrain sisted of a test section (Fig. 2), an air supply, and a water supply. The annular test section with an inner diameter (D i ) of 8 mm, outer diameter (D o ) of 12.5 mm (Hydraulic diameter (D H ) is 4.5 mm) and overall length of 880 mm, made of transparent acrylic glass were used in the present study. Other parts were constructed accurately by machining an ingot of acrylic glass. The ability of wetting/dewetting due to different surface tensions was, therefore, minimized. The inclination angles of the test section are 0, 30 and 60. It should be noted that the test section was accurately constructed and is our latest development. It was designed and employed after problems were encountered from several test sections used in previous experiments. The connections of the piping system were designed such that parts could be changed very easily. The water at room temperature and atmospheric pressure from the water tank was pumped through the rotameter, the air water mixer and the test section. The surplus water was sent back to storage tank through the control valve. Water in the system was controlled by water flow meter with different measure range. The air at room temperature and atmospheric pressure from the air compressor was pumped to the air tank with high pressure. The high-pressured air was sent into the system through the air pressure regulator in order to control the stability of pressure. Air was supplied from a compressor to pass through the reservoir, the regulator, the flow meter, the mixer and the test section. The air water mixer was constructed of many smalldiameter tubes with 6 mm inside diameter (Fig. 3). Both the air and water were brought together in a mixer and then passed through the test section co-currently. The flow rates of air were measured by five sets of rotameters within Fig. 3. Schematic diagram of mixing section. the range of 0.1 1, 1 10, 10 100, 100 500, 600 3000 SCFH, respectively. The flow rates of water were measured by four sets of rotameters within the range of 0.063 0.315, 0.3 1.5, 1 4, 4 36 LPM, respectively. The accuracy of the air and water volumetric flow rates is ±2%. The air water mixing section served to introduce water smoothly along the test section. The water from the mixer flowed together with air, and then flowed back to the storage tank. Type T thermocouples were used to measure fluid temperatures. The uncertainty of temperature measurements is ±0.1 C. Air and water pressures at the inlet of the mixer were measured by precision Bourdon tube pressure gauges. The pressure was measured through a tap with a 1.5 mm hole drilled into the tube in which the fluids flow. Two-phase pressure at the inlet of the test section was measured by the pressure transducer calibrated from 0 to 10 bar with a ±20 mbar accuracy. A differential pressure transducer was installed in the test section within the length of 420 mm, to measure the pressure drop across the test section. The range of the transducer was 5 500 kpa. The transducer has an accuracy of ±0.1% of its calibrated span. The averaging time of pressure drop measurements was around 5 s. All pressure taps were mounted flush in the tube wall. Liquid hold-up was measured by using two quickly-closing valves. The uncertainty in the measured liquid hold-up was estimated to be 0.2%. These valves were simultaneously closed to determine the relative volume of air and water trapped. Three samples were taken to obtain the average value. The process of each flow pattern formation was registered in detail by high-speed camera and digital camera. Experiments were conducted at various air and water flow rates, various inclination angles of the channel. In the experiments, the air flow rate was increased by small increments while the water flow rate was kept constant at a pre-selected value. The system was allowed to approach steady conditions before the air and water flow rates, flow pattern, pressure drop and void fraction were recorded. Special plug to support the inner tube and reduce the exit effect. 30 mm. 220 mm. 420 mm. Tap 3mm. Gap Special plug to support the inner tube and reduce the entrance effect. 220 mm. 30 mm. Flow direction Ball valve PVC tube Cover Coupling Inner glass tube Outer glass tube O-ring seal Fig. 2. Schematic diagram of test section.

348 S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 3. Results and discussion 3.1. Flow patterns Fig. 5. Flow patterns for D o = 12.5 mm, D o = 8.0 mm, h =0. Fig. 4. Sketches of flow patterns. Visual observations were obtained using a high-speed camera, digital camera and video recorder. Typical photographs and sketches of the observed flow patterns, obtained at the middle of the test section, are shown in Figs. 4 6. These observed flow patterns can be described as follows. a. Plug flow (P): This flow pattern occurs at a relatively low air velocity. The flow pattern is characterized by a continuous stream of elongated bubbles flowing along the upperside of the tube. b. Slug flow (S): At a certain air flow rate, the air water interface becomes more wavy and unstable. Waves with higher amplitudes grow and block the whole tube section and are then pushed strongly by the air with a very high velocity. Water slugs occasionally pass through the tube with a higher velocity than the bulk of the water. The upstream and downstream portions of water slug are similar to stratified wavy flow. c. Annular flow (A): This flow pattern is characterized by the complete separation of the water and air, with flowing of the water film on the outer and inner tube walls and air in the core. d. Annular/slug flow (A/S): Formation of the annular/ slug flow is similar to that of the annular flow, except for some frequent appearances of water slug. e. Bubbly/plug flow (B/P): With increasing air flow rate, many small bubbles are combined to form bullet shaped bubbles. The train of these bubbles follows the channel line in the continuous liquid phase which contains a dispersion of smaller bubbles. f. Bubbly/slug plug flow (B/S P): This is similar to the bubbly/plug flow, however due to higher air velocity, larger bubbles are formed through combination of smaller ones. In this flow pattern, slug and plug flow take place by turns and is difficult to be identified. g. Churn flow (C): Churn flow is formed by a breakdown of the slug flow bubbles. This leads to an oscillatory motion, for example, of the liquid downward and upward flows in the inclined tube. h. Dispersed bubbly flow (Db): The flowing liquid phase is continuous and contains a dispersion of small circularshaped bubbles of various sizes. i. Slug/bubbly flow (S/B): Similar to slug flow, but the liquid slug contains a dispersion of smaller bubbles. It should be noted that slug flow was found only in the horizontal channel whereas slug/bubbly flow was found

S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 349 Fig. 6. Flow patterns for D o = 12.5 mm, D o = 8.0 mm, h =30. only in the inclined channel. The usual method in the presentation of flow pattern data, is to classify the flow pattern by visual observation and plot the data as a flow pattern map in terms of system parameters. Parameters used in the present study are the phase superficial velocities. The superficial velocity of gas (U SG ) and of liquid (U SL ) refer to the situation where the designated phase flows alone in the pipe. In the present study, both superficial velocities refer to average ambient conditions (1.013 bar, 30 C). Figs. 7 9 show two-phase flow data and flow pattern maps for a test section having D i = 8 mm, D o = 12.5 mm, at h =0, 30 and 60, respectively. The solid lines in this figure represent the boundary of the flow patterns and transition from one flow pattern to another. Actually, due to the uncertainty at the vicinity of the transitions between flow patterns, the flow patterns do not change suddenly. Therefore, the transition lines should be represented as broad transition bands. The flow pattern map is valid in the range of 0.02 65.50 m/s for U SG, and 0.07 6.10 for U SL. In Fig. 10, a comparison is shown of our present flow pattern transitions obtained from the horizontal channel with the measured data of Ekberg et al. [17] obtained from the air water experiment using horizontal annuli with D i = 6.6 mm and D o = 8.6 mm. The region of plug flow obtained from the present study is in good agreement with the slug/plug flow region obtained from Ekberg et al. All their stratified-slug flow data are in the slug flow region of the present flow pattern map. The annular-slug flow data agrees very well with that of our annular/slug flow region. Most of the annular flow data of Ekberg et al. is located in our annular flow region. The churn flow data of Ekberg et al. also shows significant agreements with respect to our transition lines. Some churn flow data is located in SUPERFICIAL LIQUID VELOCITY (m/s) SUPERFICIAL LIQUID VELOCITY (m/s) 10 10 1.1.01 1.1 θ o θ =30 Air Air Water Db B/P Water D o = 12.5 mm. o Horizontal pipe (θ =0) D i = 8.0 mm..01.01.1 1 10 100 SUPERFICIAL GAS VELOCITY (m/s) Db B/P D o = 12.5 mm. D i = 8.0 mm. B/S-P P S A/S A Plug flow (P) Slug flow (S) Annular/Slug flow (A/S) Annular flow (A) B/S-P P S/B A/S A Plug flow (P) Slug/Bubbly flow (S/B) Annular/Slug flow (A/S) Annular flow (A) Bubbly/Plug flow (B/P) Bubbly/Slug-Plug flow (B/S-P) Churn flow (C) Dispersed bubbly flow (Db).01.1 1 10 100 SUPERFICIAL GAS VELOCITY (m/s) Fig. 8. Present flow pattern map for D o = 12.5 mm, D i = 8.0 mm, h =30. C C Bubbly/Plug flow (B/P) Bubbly/Slug-Plug flow (B/S-P) Churn flow (C) Dispersed bubbly flow (Db) Fig. 7. Present flow pattern map for D o = 12.5 mm, D o = 8.0 mm, h =0.

350 S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 SUPERFICIAL LIQUID VELOCITY (m/s) 10 1.1 θ P Db B/P B/S-P Plug flow (P) Slug/Bubbly flow (S/B) Annular/Slug flow (A/S) Annular flow (A) Bubbly/Plug flow (B/P) Bubbly/Slug-Plug flow (B/S-P) Churn flow (C) Dispersed bubbly flow (Db) D o o = 12.5 mm. θ =60 Air Water D i = 8.0 mm..01.01.1 1 10 100 SUPERFICIAL GAS VELOCITY (m/s) C S/B A/S A Fig. 9. Present flow pattern map for D o = 12.5 mm, D i = 8.0 mm, h =60. Fig. 11. Effect of inclination angle on the air water flow pattern map for an annular channel with D o = 12.5 mm, D i = 8.0 mm. SUPERFICIAL LIQUID VELOCITY (m/s) 10 1.1 Data of Ekberg (1999) D o = 8.6 mm., D i = 6.6 mm. Slug/Plug flow Stratified-Slug flow Annular-Slug flow Annular flow Bubbly-Plug flow Churn flow Dispersed bubbly flow Db B/P B/S-P P S A/S A Present transition lines ( θ = 0º).01.01.1 1 10 100 SUPERFICIAL GAS VELOCITY (m/s) the region of bubbly/slug plug flow and annular/slug flow in our map. The bubbly plug flow region of Ekberg et al. is in good agreement with respect to our bubbly/slug plug flow region. Some dispersed bubbly flow data of Ekberg et al. appear in the bubbly/plug flow region of our flow regime map. Some discrepancies in the comparisons depend mainly on the identification of flow pattern according to their definitions and also the configurations of inlet and outlet sections. However, in general, some parts of the results agree qualitatively. Fig. 11 shows the flow pattern maps for air water at different inclination angles. The effect of the inclination angle on the transition lines between the plug flow (P) and the slug flow (S) for h =0, and between the plug flow (P) and the slug/bubbly flow (S/B) for h =30 and 60 are very interesting. At the same superficial water velocity, as a channel with a higher inclination angle was used, the P! S transition line (for h =0 ) and the P! S/B transition line (for h =30, 60 ) shifts to a lower value of superficial air velocity. As the inclination angle increases, the gravitational force increases. As a result, a channel with a higher inclination angle enables the bubbles to be formed at lower air velocity. This is different from the S! A/S (for h =0 ) and the S/B! A/S (for h =30, 60 ), the A/ C D o D i 12.5 mm. 8.0 mm. Fig. 10. Present flow pattern map compared with the experimental data of Ekberg et al. [17]. S! A and B/S P! C transition line, which tend to shift to a higher value of superficial air velocity at the same superficial liquid velocity. In these flow regions, the gravity dominates the flow mechanism. The increase of the air velocity enables the flow pattern to be maintained. It should be noted that, as the inclination angle increases, there are only small shifts of the transition line between the dispersed bubbly flow (Db) and the bubbly/plug flow (B/P), the bubbly/plug flow (B/P) and the bubbly/slug plug flow (B/S P), and the bubbly/plug flow (B/P) and the plug flow (P). The plug flow region becomes smaller, while the slug flow region (for h =0 ) and the slug/bubbly flow region for h =30 and 60 become larger. 3.2. Pressure drop Considering the pressure drop in the horizontal tubes (h =0 ), it could be seen from Fig. 12 that the pressure drop depends on flow pattern and velocity of gas and liquid. At low liquid velocity, the increase of gas velocity until the flow pattern changed from plug flow to slug flow makes the pressure drop increase quickly. This is because when the gas velocity increases, the liquid slug is pushed by the high speed gas to move rapidly, and causes the pressure drop to increase abruptly. When the gas velocity further increases until the flow pattern changes from slug flow to annular/slug flow, the liquid is more replaced by gas and the rise of pressure drop stops. When the gas velocity is high enough to induce sufficient turbulence in the fluid, the pressure drop begins to rise again, due to friction. At higher liquid velocity, on the other hand, the pressure drop rises slowly at first, due to low gas velocity. This is similar to a single-phase flow i.e., liquid. However, when the gas velocity increases until the flow is sufficiently turbulent, the pressure drop is also risen. Considering the pressure drop in the tubes with h = 30 and 60 as shown in Figs. 13 and 14, it could be seen that at low gas and liquid velocity, the pressure drop during the slug/bubbly flow pattern is not risen abruptly as in the horizontal tubes, because of the effect of gravity. The values of

S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 351 pressure drop occurred in inclined tubes at low gas and liquid velocity are similar at first because the flow at low gas and liquid velocity is not sufficiently turbulent. Hence, the effect of gravity on fluid is more obvious than the friction. However, when the gas velocity increases, the pressure drop also increases. In general, for all inclination angles, the change of pressure drop characteristics corresponded to the flow pattern transitions. Comparing the pressure drop occurred in the 30 -inclined and 60 -inclined tubes as shown in Fig. 15, it could be seen that at low gas and liquid velocity the pressure drop occurred in inclined tubes is higher than the pressure drop occurred in horizontal tubes. This is because at low gas and liquid velocity, the flow is not turbulent enough, due to the obvious effect of gravity on the fluid. When the inclination angle increases, however, the flow becomes more turbulent and makes the effect of friction more prominent. At the same time, the effect of gravity gradually decreases because more liquid is replaced by gas. Consequently, the values of pressure drop occurred in the horizontal, 30 -inclined, and 60 -inclined tubes at high gas and liquid velocity are more similar. The pressure Air Water Fig. 12. Relationship between pressure drop and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =0. Fig. 13. Relationship between pressure drop and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =30.

352 S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 Fig. 14. Relationship between pressure drop and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =60. drop in inclined tubes tends to be slightly higher, due to the effect of gravity on fluid inside the inclined tube. The twophase frictional pressure gradient can be obtained by subtracting the gravitational and accelerational terms from the total experimental pressure gradient. Fig. 16 shows the plot of Martinelli parameter against the two-phase frictional multiplier. In this figure, comparison of experimental data with the Lockhart Martinelli correlation is shown. The correlation with C = 5 and 20 are shown by a solid line. Fig. 17 shows the comparison of the homogeneous flow model (HEM) with experimental data for h =0. There is an overall agreement between the results obtained from the experiment and those obtained from the model. 3.3. Void fraction From Figs. 18 20, values of void fraction found in the horizontal, 30 -, and 60 -inclined tubes tend to go in the same direction that is, varied by the values of superficial velocity of both gas and liquid. In other words, void fraction increases when the gas velocity increases. For example, when the fluid changes its flow pattern from annular/slug flow to annular flow (A/S! A), it has to increase its velocity in order to form a liquid film at the tube surface. According to the definition of annular flow, when the gas velocity increases, the liquid part would be increasingly replaced with gas. This causes the increase of void fraction. On the other hand, when the liquid velocity increases, the value of void fraction decrease, due to more replacement of gas with liquid. Fig. 15. Relationship between pressure drop and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =0, 30 and 60. Fig. 16. Martinelli parameter versus the two-phase frictional multiplier.

S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 353 Fig. 17. Comparison of the present data with the prediction. Fig. 20. Relationship between void fraction and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =60. Fig. 18. Relationship between void fraction and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =0. From Figs. 18 20, values of void fraction occurred in the tube with h =0, 30 and 60 were similar. However, the value of void fraction seems to decrease when the inclination angle increase, because the liquid was naturally pulled to the bottom by gravity when the inclination angle increases. Some part of liquid may be able to resist the gas flow, which increases amount of water stored in the inclined tubes. Hence, the value of void fraction tends to decrease when the inclination angle increases. Fig. 21 shows the plot of Martinelli parameter against the measured void fraction. It can be clearly seen that void fraction approaches 1 when Martinelli parameter is decreased. Fig. 22 shows the comparison of the correlation proposed by the CISE group (Premoli et al. [18]) with the present measured data. The results obtained from the model show reasonable agreement with the experimental data at high superficial velocity of water. It should be noted that several mathematical models were evaluated in our study. However, only the best one is presented. Fig. 19. Relationship between void fraction and superficial gas velocity for D o = 12.5 mm, D i = 8.0 mm, h =30. Fig. 21. Martinelli parameter versus void fraction.

354 S. Wongwises, M. Pipathattakul / Experimental Thermal and Fluid Science 30 (2006) 345 354 References Fig. 22. Comparison of the present data with the prediction. 4. Conclusion The experimental results of flow pattern, void fraction and pressure drop of gas liquid flow in a narrow concentric annular channel were presented. The annular transparent test section with an inner diameter of 8 mm, outer diameter of 12.5 mm, and overall length of 880 mm was used. The inclination angles of the test section (h) were 0, 30 and 60. Air and water were used as working fluids. The gas superficial velocity and liquid superficial velocity were varied in a range of 0.0218 65.4 m/s and 0.069 6.02 m/s, respectively. The plug, slug, annular/slug, annular, bubbly/plug, bubbly/slug plug, churn, slug/bubbly and dispersed bubbly two-phase flow patterns were observed in the experiments. The slug/bubbly flow pattern was found only in the case of h =30 and 60, while the slug flow pattern was found only in the horizontal channel. The experimental results showed that the inclination angle has a significant effect on the flow pattern transition, pressure drop and void fraction. Several existing models were used to compare calculations with the experimental data. However, in the present paper, the best ones were proposed. For h =0, the homogeneous flow model (HEM) gave the overall agreement with the measured pressure drop data while the CISE correlation gave reasonable agreement with the void fraction data. Acknowledgement The present study was financially supported by the Thailand Research Fund (TRF) whose guidance and assistance are gratefully acknowledged. [1] L. Zhao, K.S. Rezkallah, Gas liquid flow patterns at microgravity condition, International Journal Multiphase Flow 19 (1993) 751 763. [2] T. Wilmarth, M. Ishii, Two-phase flow regime in narrow rectangular vertical and horizontal channels, International Journal of Heat and Mass Transfer 37 (1994) 1749 1758. [3] T. Wilmarth, M. Ishii, Interfacial area concentration and void fraction of two-phase flow in narrow rectangular vertical channels, Journal of Fluid Engineering 19 (1997) 916 922. [4] J. Bonjour, M. Lallemand, Flow patterns during boiling in a narrow space between two vertical surfaces, International Journal of Multiphase Flow 24 (1998) 947 960. [5] J. Xu, Experimental study on gas liquid two-phase flow regimes in rectangular channels with mini gaps, International Journal of Heat and Fluid Flow 20 (1999) 422 428. [6] J. Xu, P. Cheng, T.S. Zhao, Gas liquid two-phase flow regimes in rectangular channels with mini/micro gaps, International Journal of Multiphase Flow 25 (1999) 411 432. [7] T. Hibiki, K. Mishima, Flow regime transition criteria for upward two-phase flow in vertical narrow rectangular channels, Nuclear Engineering and Design 203 (2001) 117 131. [8] K. Mishima, M. Ishii, Flow regime transition criteria for upward twophase flow in vertical tubes, International Journal of Heat and Mass Transfer 27 (1984) 723 737. [9] T.S. Zhao, Q.C. Bi, Co-current air water two-phase flow patterns in vertical triangular micro-channels, International Journal of Multiphase Flow 27 (2001) 765 782. [10] M.K. Akbar, D.A. Plummer, S.M. Ghiaasiaan, On gas liquid twophase flow regimes in micro-channels, International Journal of Multiphase Flow 29 (2003) 855 865. [11] K.S. Rezkallah, Weber number based flow pattern maps for liquid gas flows at microgravity, International Journal of Multiphase Flow 22 (1996) 1265 1270. [12] P. Balasubramanian, S.G. Kandlikar, High speed photographic observation of flow patterns during flow boiling in single rectangular minichannel, ASME Summer Heat Transfer Conference July 21 23, 2003, Las Vegas, Nevada, USA. [13] P. Satitchaicharoen, S. Wongwises, Two-phase flow pattern maps for vertical upward gas liquid flow in mini-gap channels, International Journal of Multiphase Flow 30 (2004) 225 236. [14] R.T. Lahey, K. Ohkawa, An experimental investigation of phase distribution in an eccentric annulus, International Journal of Multiphase flow 15 (1989) 447 457. [15] V.C. Kelessidis, A.E. Dukler, Modeling flow pattern transitions for upward gas liquid flow in vertical concentric annuli, International Journal of Multiphase Flow 15 (1989) 173 191. [16] S.I. Osamasali, J.S. Chang, Two-phase flow regime transition in a horizontal pipe and annulus flow under gas liquid two-phase flow, ASME FED 72 (1988) 63 69. [17] N.P. Ekberg, S.M. Ghiaasiaan, S.I. Abdel-Khalik, M. Yoda, S.M. Jeter, Gas liquid two-phase flow in narrow horizontal annuli, Nuclear Engineering and Design 192 (1999) 59 80. [18] A. Premoli, D. Francesco, A. Prina, A dimensionless correlation for determining the density of two-phase mixtures, Lo Termotecnica 25 (1971) 17 26.