TOTAL SAFETY. It adapts perfectly to the problems of each project while being completely environmentally friendly and pollution-free.

Similar documents
SAFE AND ENVIRONMENTALLY FRIENDLY

Effective protection thanks to the latest technology

Quick Specs. INERGEN Clean Agent Fire Suppression System

IG01 EXTINGUISHANT AGENT

with FE -13 TM Most DuPont FE-13 systems are designed with a concentration of 15.9% whereas the NOAEL level of this extinguishing agent is 30%.

THE INERT GAS SYSTEM SO SAFE IT EVEN PROTECTS YOUR BUDGET.

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

KFI Approved. High Pressure CO2 System Technical Datasheets

BERMAD Fire Protection Hydraulic Control Valves

BacPac; A portable WaterMist fire suppression kit; designed for rapid response situations. Model: FB33

MEDICAL EQUIPMENT CATALOG

NGN Series nitrogen generator

Guidelines for Clean Agent Fire Suppression Systems

Chapter 13 Selection and Safe usage of cleaning solvents

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

CAPITAL CONTROLS SERIES NXT3000

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

SAFETY DATA SHEET GAS MIXTURES ARGON 75% CARBON DIOXIDE 25%

Capacity and pressure similar to R-507. Flooded systems. Low temperature (-46.7 C). R22 replacement as long as the condenser has the right size.

Air-duster / Gas White-Paper Written by Keith Carruthers

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Installation of Ballast Water Management Systems

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Potter Nitrogen Generators

Pressure Automated Calibration Equipment

SAFETY DATA SHEET According to Regulation (EC) N 1907/2006

Let our solutions keep you safely afloat offshore. Reliable gas services from Linde Gas Benelux.

Smoke and gas tightness of Hilti Firestop products

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Laboratory Safety Committee

Piped Air SCBA Refilling System Standard

FOGEX HIGH-PRESSURE WATER MIST CYLINDER SYSTEMS

Autocalibration Systems For In Situ Oxygen Analyzers

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

DF1 and DF2 Diffusers

TECHNICAL DATA. than the water inlet pressure to the concentrate

MATERIAL SAFETY DATA SHEET

Unit 24: Applications of Pneumatics and Hydraulics

TECHNICAL DATA ACCELERATOR MODEL E-1

Dräger Swede Survival System Phase 1 Flashover Development Observation

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

ELECTRIC ACTUATORS for continuous underwater use

CO 2 Suppression Systems

Central Gas System Inquiry. Check List - Detailed Form

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Wilkins Safety Group

Inert Air (N2) Systems Manual

Trifecta High-Pressure Systems

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

Transferring and Storage

Phuel Modular Control Units

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

SAMPLING SYSTEMS FOR LIQUIDS AND GASES FOR ALL TYPES OF APPLICATIONS

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

PV4 and PV6 Piston Valves

Class 2 Gases Learning Tool

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

Active Fire Prevention by Oxygen Reduction Systems

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

SV60 Safety valves. for use with steam, gas and liquids

Basic & Controlled Atmosphere Glove Boxes

TECHNICAL DATA. Q = C v P S

Compressed Gas Cylinders - Guideline

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

COMITÉ EUROPÉEN DES ASSURANCES

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Precision matters. HiQ equipment for specialty gases.

Data Sheet Issue A

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Vortex Dual. Refrigerant Recovery Machine

Tightness controls TC 1 3 and TC 4

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Instrumental Technique GAS CYLINDER

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

6890 GC Site Preparation

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Corrosion Protection in Dry-Pipe Systems Article and photos by Gregory Havel, except where noted. May 21, 2018

Transcription:

TOTAL SAFETY Fire protection finds a great ally in IG-55. This agent combines adaptability to each project with excellent firefighting capacity, proven effectiveness and environmental friendliness. Companies, institutions and even individuals need to effectively protect their assets and people against the destructiveness of fire. Rapid extinguishing is essential if what is protected has great value, preventing damage that could seriously affect the activity carried out, temporarily or indefinitely disrupting productivity, and even saving lives. The INERT SIEX 55 system has been developed to meet this demand. It uses an inert, clean, safe and environmentally friendly agent which ensures continuous and effective protection of property and occupants. It adapts perfectly to the problems of each project while being completely environmentally friendly and pollution-free. We are committed to ensuring this effectiveness, which is why we rely on the most complete and advanced system.

IG-55, EFFECTIVE AT ALL LEVELS IG-55 agent is a 50/50 blend of nitrogen and argon. It combines effective action against fire with the flexibility required for any functional need and hazard configuration, protecting staff at all times. + 50% ARGON 50% NITROGEN It is VERSATILE, protecting the entire enclosure of a variety of hazards, thanks to its blend of gases. Nitrogen tends to settle in the middle and top of a room, while argon settles towards the bottom. Both gases spread out to fully cover the protected area, occupying any gap. It is EFFECTIVE and SAFE, with superb extinguishing capability. It does not interact with equipment due to its inert nature, focusing all its effects on combating the fire. It is compatible with standard construction materials and ensures successful and safe evacuation of occupants. Since the gas is extracted from the atmosphere, it is 100% ENVIRONMENTALLY FRIEN- DLY: it does not deplete the ozone layer (ODP) and has zero global-warming potential (GWP). It is CLEAN: it dissipates quickly with simple ventilation and does not generate residue. It is recommended for protecting fragile and sensitive objects. * * *Pending

COMPONENTS CYLINDERS at 150 and 200 BAR Pressures at 200 bar are the most widely used globally and ensure compatibility with maintenance and refill installations and equipment in any country. Equipment at 150 and 200 bar includes RGS- MAM-12-2 or 2C high-flow valves, featuring quick release for easy maintenance and refilling. They are made with forged brass and include a control gauge (0-315 bar). 150 y 200 bar Cilindro Carga IG-55 Válvula Latiguillo 150 bar 200 bar 40 litros 5.94 m 3 RGS-MAM-12-2 67 litros 9.90 m 3 13.20 m 3 ó 80 litros 15.90 m 3 RGS-MAM-12-2C Modelo FH-15CO 140 litros 27.80 m 3

SIEX s RGS-MAM valves are very versatile and easy to handle. They allow handling when the cylinder is filled, thus ensuring faster maintenance. CAPACITIES OF 40, 67, 80 Y 140 LITRES They are constructed of seamless carbon steel. In banks of more than nine cylinders, a pilot bottle for activation is included. A pilot cylinder of N2 is included for the activation of cylinder banks containing more than ten units.

ACTUATORS: Placed in the valve actuation ports, they start the discharge, actuating cylinders as required in each case: Handling is quick and easy. It can be installed with dry pipes, even en with a loaded cylinder, without losses and with the maximum simplicity. electrical manual pneumatic electric firing pin pyrotechnic/manual pneumatic/manual remote manual by pull cable (protective case available) SAFETY PNEUMATIC RETARDERS Pneumatically and safely delay extinguishing agent discharge, either directly, acting through a modular or master cylinder in a cylinder bank or indirectly, through a pilot cylinder. This lag time is 30 or 60 seconds, enough for staff to evacuate safely once the alarm is triggered. This device allows overriding the delay manually, if necessary. The operation is completely self-contained, and its failproof pneumatic operation prevents any delay that could prove dangerous, thus ensuring safety at all times. PRESSURE DAMPERS They prevent structural damage due to excess pressure during IG-55 discharge, allowing displaced air to be released and subsequently sealing the room to ensure leak tightness. PNEUMATIC SIRENS Facilitates evacuation of the enclosure in case of imminent discharge, thus improving system security.

EXPERIENCE AND QUALITY INERT SIEX 55 is certified by major international agencies, which highlights its quality. It is developed to comply with all relevant standards: ISO 14520:15, UNE 15004-9, NFPA 2001 and CEA 4008. * * It also complies with ISO 9001:2000, ISO 14001:2004 and European CE and VdS standards, as well as American UL* and FM* standards. *Pending SIEX supports its customers in all phases of the project thanks to the experience accumulated throughout its history. This ensures success in all situations. We provide comprehensive technical support in all project phases via hydraulic calculation software, tips, manuals, aftersales service and maintenance.

OPERATION The SIEX IG-55 agent is a blend of 50% nitrogen and 50% argon, both gases obtained from the atmosphere. They are stable and do not react, thus completely avoiding the formation of dangerous compounds either by temperature, pressure, humidity or the presence of any other chemical compound. The IG-55 extinguishing agent The use of this agent covers numerous applications: solid, flammable liquid, electrical and electronic fuels. These systems can be adapted for total flooding protection of enclosures of any construction, size and configuration. Proven safety for people High extinguishing capability 100% environmentally friendly Easy to store agent away from protected hazard. Leaves no residue or condensation inside the protected enclosure Electrically non-conductive Suitable for use with selector valves

EXTINGUISHING ARGON NITROGEN The IG-55 agent has unique properties that optimize its action: stratification of agent at various levels (argon, more dense than air, in the middle and lower parts, and lighter nitrogen above) provides comprehensive protection throughout the enclosure, minimizing possible leaks. STRATIFICATION IMPROVES PROTECTION THROUGHOUT THE ENCLOSURE. The ARGON remains in the upper part of the room, while the NITROGEN descends to the lower part Applying a pressurized gas over an object influences the efficiency of extinguishing very favourably: gases are highly miscible with each other, so agent concentration will be homogeneous. Besides, the pressure pushes and displaces the ambient air from any corner of the room, ensuring a three-dimensional action, regardless of obstacles and shields.

APPLICATIONS Stations and airports Telecommunication systems Computer Rooms Gas facilities Offshore platforms Hospitals Wind turbines Petrochemical facilities Laboratories Electrical cabinets and substations Archives and libraries Educational establishments Pharmaceutical Industry Museums and art galleries Offi ces Residential buildings

BENEFITS of using INERT SIEX-55 PROTECTION OF THE ENCLOSURE FROM FLOOR TO CEILING, THANKS TO STRATIFICATION. ITS OMNIDIRECTIONAL ACTION REACHES INACCESSIBLE SPACES, MOVING BETWEEN OBSTACLES. AT THE SAME TIME IT BENEFITS: THE INSTALLER: THE USER: Quick and easy installation. Allows for long and complex pipe runs. Safe valves which can be manipulated with loaded cylinders. Fast and simple maintenance. Total, safe protection in case of fire. Safe evacuation, maintaining an appropriate level of oxygen. Existence of safety-enhancing components: retarder, siren, etc. THE CUSTOMER: THE PLANET: Immediate resumption of activity, no cleaning work and no damage to documents or assets. Clean and non-toxic, does not damage the equipment. No impact on ozone (ODP) No global warming potential (GWP) Does not pollute or produce residues. Minimal use of storage space. Low protection system cost.

SIEX 2001 S.L. C. Merindad de Montija nº 6 P.I. Villalonquéjar 09001 Burgos (SPAIN) TLFNO: +34 947 28 11 08 WEB: WWW.SIEX2001.COM SIEX is a registered trademark. The information provided in this document is for information purposes only. Technical information must be used for the installation of all SIEX systems. SIEX assumes no liability for any use that third parties may make of this information. SIEX reserves the right to make any change in both the capabilities and features of its equipment.