Over 20,000 Strain Gage Target flowmeters installed since 1952.

Similar documents
Pro-V Multivariable Flowmeter Model M22 In-line Vortex

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx

780S Ultra High Purity Series

Features. Description

analytical bulk flow distance FLOW level pressure temperature industrial communication

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

9700 Transmitter Submersible hydrostatic level transmitter

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Design Features. General Description

Wafer type. the product

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Mass Flowmeters. Mass Flowmeters for Gases

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

mass flowmeter approved by Weights and Measures for custody transfer

Ultra High Purity Model 780S

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Integral type Differential pressure flowmeter VNT Series

Online data sheet FLOWSIC30 GAS FLOW METERS

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

LUGB Vortex Flowmeter

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Flow metering in gases Introduction to COMBIMASS family

RCD - Ultra-Rugged Differential Pressure Flowmeter

Mass Flow Controller (MFC) for Gases

Mass Flow Controllers

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Model 601CV. Mass Flow Controller. Product Features:

Viatran s Sanitary Pressure and Level Measurement Family

High-performance submersible pressure transmitter For level measurement Model LH-10

Turbine Flowmeters for Liquid Applications

UNDERSTANDING, ACCELERATED

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Turbine Flowmeters for Gas Applications

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

P499 Heavy Duty Pressure Transducer

T EK-SUB 4800C 19 mm Submersible Level Transmitter

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Steel-Mass Model 640S

Vortex Meters for Liquids, Gas, and Steam

NEW VERSAFLOW CORIOLIS

Torque Tube TB300 Digital Transmitters

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Mass Flow Meter (MFM) for Gases

86BSD Backside Digital Output

200A Series ELECTRONIC LEVEL TRANSMITTER

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

TH-1800-T TRX-700-CNG Converter

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Mass Flow Controller (MFC) for Gases

Turbine Flowmeters for Gas Applications

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

American Sensor Technologies. Your Sensor Business Partner...

Thermatel Model TA2 Mass Flow Transmitter

Low Profile Load Cells

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Coriolis Mass Flow Meter

The Discussion of this exercise covers the following points:

BI-680 Online Dissolved Oxygen Controller Instruction Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

Differential Pressure Transmiter

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

3.0 Pressure Transmitter Selection

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

How to specify a product. Process Sensors and Mechanical Instruments

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

American Sensor Technologies. Your Sensor Business Partner...

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Pressure and Vacuum Switches for Process Applications

Liquid Level Measurement

Transcription:

Over 20,000 Strain Gage Target flowmeters installed since 1952. Liquid, gases, superheated and saturated steam from -320 to 500 O F and up to 15,000 psi. No frictional moving parts. Designed to withstand 100% over range. Tested to over 100 million full-scale flow cycles with no measurable effect on performance.

Features Wide Rangeability Easily field modified by replacing target for range changes Field Accuracy Calibration Verification of flowmeter accuracy without flow testing Versatile Mounting Options Inline: Flange, MNPT, 37O Flare Tube and more Insertion: Fixed, Retractable (hot-tap option) and more Rugged Flow Sensor Construction All welded construction Withstands thermal shock Hermetically sealed Fixed insertion Corrosion-Resistant Wetted Parts Stainless Steel Hastelloy C-276 Inconel Long Service Life Provides years of maintenance-free operation Offered with a two-year warranty Bi-directional Flow Option Accurately measures flow in either direction Retractable insertion for hot tap applications

How the Aaliant Strain Gage Target Flowmeter Works Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted outside the flow stream translate force into an electrical output. This output is proportional to flow rate squared. Basic Principle of Operation Bridge Circuit Diagram Force = CdA V 2 2g Cd = drag coefficient A = target area rho ( ) = fluid density V 2 = velocity head 2g How a Bridge Circuit Works Forces from the fluid flow are transferred from the target to the sensing tube Four interconnected strain gages (attached to the sensing tube two on forward side of flow,two on reverse side of flow) produce a four-active arm, bridge circuit At zero flow, the bridge circuit is balanced and produces zero output Flow produces strain on the sensing tube The bridge circuit becomes unbalanced, producing an output

Accessories Model 1030AP and 1030AW Indicator/Totalizers The Model 1030 is a microprocessor based flow rate indicator/totalizer with a 4-20 ma output that is proportional to flow rate and RS-485 communications. Flow rate and total can be displayed simultaneously on the 16-character display. The Model 1030 has five control inputs, which when switched to ground, perform specific functions such as resetting the totalizer. Four open collector control outputs may be used to interface with remote devices such as relays, counters, and lights. Model 1530AP and 1530AW Mass Flow Computers The Model 1530 is a microprocessor based, pressure and temperature compensated, mass flow rate indicator/totalizer. A 4-20 ma output that is proportional to the compensated flow rate and RS-485 communications interface with chart recorders, PLCs, and computers. The 16-character display provides one touch indication of compensated flow rate/total, pressure, or temperature. The Model 1530 has two control inputs, which when switched to ground, perform specific functions such as resetting the totalizer. Four open collector control outputs may be used to interface with remote devices such as relays, counters, and lights. Model 3030 Batch Controller, Indicator/Totalizer The Model 3030 is a microprocessor based batch controller/flow rate indicator/totalizer that is capable of single or dual stage batch control. Two process parameters such as batch count and final batch quantity can be displayed simultaneously on the 16-character display. The Model 3030 has five control inputs, which when switched to ground, perform specific functions such as remote batch stop. Four open collector control outputs may be used to interface with remote devices such as relays, counters, and lights. Model 7431 and 7437 BTU Calculators The Model 7431 and Model 7437 BTU calculators are used to measure individual energy consumption in virtually any liquid heating/cooling system such as apartment complexes, office buildings, hospitals, colleges, and universities. The BTU system consist of a Model 7431 or Model 7437 BTU calculator, a supply temperature sensor, a return temperature sensor, and a flowmeter/transmitter.

Applications Gases air, natural gas, argon, and more Saturated and Superheated Steam Cryogenic Liquids from -320 o F (-195 o C) nitrogen, oxygen, carbon dioxide, and more Corrosive Liquids acetic acid, sodium hydroxide, hydrogen peroxide, and more ANSI & DIN flanges available Hydrocarbons jet fuel, kerosene, hydraulic fluids, and more Water deionized, distilled, demineralized, and more S P E C S Line Sizes Operating Pressure 1 /2 to 60 (15mm to 1500mm) up to 15,000 psig (690 bar) Operating Temperature from - 320 o to 500 o F (-195 o to 260 o C) Repeatability Accuracy + 0.15% of rate + 1.0% of rate Flow Turndown Ratio up to 15:1 Flow Range Power Required Outputs Approvals 0.13 gpm to 230,000 gpm (0.5 l/min to 1,045.6 m 3 /min) 24 VDC with transmitter 4-20mA DC and more CSA: Class I Div 1 Groups B, C, D CSA: Class I Div 2 Groups A, B, C, D to 299 psig FM: Class I Div 2 Groups A, B, C, D to 299 psig

Available Options Line Sizes Insertion: 4-60 (100-1500mm) Inline: 1/2-6 (15-150mm) Sanitary: 3/4-4 (20-100mm) Mounting Connections AN 37 Flare Tube Inline Flanged Inline MNPT Inline Wafer Inline 4" Flange Mounting Fixed Probe 4" Flange Mounting Retractable Probe 2" Flange Mounting Fixed Probe 2" Flange Mounting Retractable Probe MNPT Probe, Flow Switch Only Sanitary Tri-Clamp Other Mounting Options Available Wafer, flare tube, and MNPT mounting available Body Material Stainless Steel Hastelloy C-276 Inconel Transmitters Model TWS Two-wire Signal Transmitter Model TWL Linear two-wire Signal Transmitter Model 1060 Three-wire Microprocessor Transmitter Model 1100L & 1100S Two-wire/local indicator/totalizers Model 1050 Strain Gage Transmitter SFX 2000 Two-wire Smart Transmitter (HART compatible) Model FS Flow Switch Other Options Bi-directional Submersible DIN Connections Accessories Remote electronics Flow rate indicator/totalizer Mass flow computer Digital batch controller Btu calculator Contact Aaliant www.aaliant.com Locate your local, certified Aaliant distributor View/print Installation, Operation, & Maintenance Manuals and Technical Specification Sheets Customer Service Phone: (800) 778.9251 (864) 574.3327 Fax: (864) 574.8063 E-Mail: sales@aaliant.com Application Assistance Phone: (864) 574.3327 Fax: (864) 574.8062 All data subject to change without notice. C 2002 Venture Measurement. All rights reserved. S711 Rev. B