V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Similar documents
V5097A-E Industrial Gas Valves

V5097A-E Industrial Gas Valves

SPECIFICATIONS ATTENTION

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

GM-7000 Series CE Approved Gas Control Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

36H SERIES Combination Gas Valve

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

Operator: Save these instructions for future use!

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

G96 Series BASOTROL Dual Operator Valve

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

VK8515M(R) MODULATING GAS CONTROL APPLICATION DESCRIPTION SPECIFICATIONS INSTRUCTION SHEET. Electrical data

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Instruction Manual No. 742, 8/98

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

GM Series Dual-Block Multi-Function Gas Control Valves

SPECIFICATIONS CAPACITY

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instructions

SL G3. Warning

Dual Solenoid Gas Valve Installation

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Operator: Save these instructions for future use!

S300 Series. Valve Link. Features. Fisher Controls

Operator: Save these instructions for future use!

T208VR Series Tank Blanketing Vacuum Regulator

/2004 US/CA

G92 Series BASOTROL Automatic Pilot Gas Valve

Conversion instructions from natural gas to propane

Installation Instructions

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

C645A-E Pressure Switches

Noth American 7347 High Pressure Gas Regulators

VR46.5V(A)/VR86.5V(A) SERIES

V43 Pressure Actuated Water Regulating Valve

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Valve Proving System VDK 200 A S02

GAS LIMITING ORIFICE VALVES LVG SERIES

Valve Proving System VDK 200 A S06*

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

VR8305 Direct Ignition Combination Gas Control

Gas Pressure Regulator HON 300

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Gas Conversion Kit Pilot Ignition Heaters

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

BGA158 Series CE Approved Class B Shutoff Gas Valve

VR8200A Continuous Pilot Combination Gas Controls

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

1805 Series Relief Valves

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Installation Instructions For Natural Gas Conversion

IPG IGNITION GAS PILOTS BACK-LOADED GAS

PRO-50 Instrument Supply Regulator

MEGR-1627 Instruction Manual

TECHNICAL DATA. Q = C v P S

SPECIFICATIONS ATTENTION

DS06D,G Dial Set Pressure Regulating Valve

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

1200B2 Series Service Regulators. Instruction Manual

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

BGC258 Series BASOTROL Gas Valve

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

Valves for Biogases and Recycling Gases

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

VR8205S,T Direct Ignition Combination Gas Controls

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Gas Valve Replacement Kit

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Type 1190 Low-Pressure Gas Blanketing Regulator

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Types S100K and S102K Pressure Regulators

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

North American Orifice Metering System

Instructions for High Altitude Conversion

1805 Series Relief Valves

ACCESSORY KIT INSTALLATION MANUAL

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Transcription:

V5197A Firing Rate Gas Valve PRODUCT HANDBOOK APPLICATION The V5197A are firing rate valves used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases. The V5197A are actuated by a firing rate motor that can be mounted directly on the valves. The V5197A is not applicable as a safety shutoff valve. The V5197A is specially designed to provide fine control of gas flow in applications where a high turn down ratio is required. The maximum flow adjustment screw on the bottom of the valve allows adjusting the maximum flow of gas through the V5197 while maintaining the linear modulating characteristics and stroke. FEATURES Used with air, natural, manufactured or liquefied petroleum (LP) gases. For modulating applications that do not require final shutoff service of firing rate valve. Sizes DN65 and DN80. Two downstream 1/4 in. BSP threaded pressure taps available. Accepts C6097 Pressure Switch mounted directly to flange (downstream pressure tap only). Unpainted cast aluminum body. Suitable for electric or pneumatic operators with the appropriate linkage. May be used with manufacturers own linkage and any approved actuator. Adaptors provided for standard Honeywell actuators. Flow adjustment screw on bottom of valve controls maximum flow. Visual position indicator. 1 EN1C-0015SZ20 R1002

SPECIFICATIONS IMPORTANT The specifications in this publication do not include normal manufacturing tolerances; therefore, an individual unit may not exactly match the specifications listed. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Models: V5197A1029; DN65 V5197A1037; DN80 Type of Gas: Air, natural, manufactured, mixed or liquefied petroleum (LP) gases only. Pipe Size of the gas train: 2-1/2 in and 3 in. Pressure Rating: Maximum operating pressure of 1 Bar (15 psi ). Maximum Valve Capacities: SCFH gas: 0.64 sp. gr. at 1 in. wc pressure drop across valve (flow limit adjustment set at 100% open). See Table 1. Table 1. Maximum Flow Capacity (natural gas at 0.64 sp.gr.) at 2.5 mbar (1 in. w.c.) Pressure Drop Across Valve. a Pipe Size in mm. (in) Flow Capacity SCFH SCMH 64 (2-1/2) 14,800 419 76 (3) 16,900 478 Mounting: UNI PN 16; DN65 and DN80. Mechanical Strength: Group 2. Maximum flow adjustment (Fig 5): Located on the bottom of the valve with a 6 mm. (1/4 in) hex key: To decrease the maximum flow, turn clockwise to increase the maximum flow, turn counterclockwise. Mounting position: Any position. Dimensions: See Fig. 6. Weight: V5197A1029 6.3 Kg. V5197A1037 6.8 Kg. Adaptor kits for Honeywell actuators/motors: KTFRG01 (DCA) KTFRG02 (LKS) KTFRG03 (MT4000) KTFRG04 (MF4000) KTFRG05 (Mod IV) Approvals: CE approved P.I.N.: 0063BM1882 a Standard cubic feet per hour (SCFH) and standard cubic meters per hour (SCMH) listed. For other gases, multiply the listed capacity by the square root of (0.64 divided by the specific gravity of the other gas). Flow curves: See Fig. 1 through 4. NOTE: The percentage settings listed on the figures refer to the setting of the flow adjustment screw on the bottom of the V5197. Pressure drops are shown as solid, broken or dotted lines on the figures. Tapping and plug: Two downstream 1/4 in. BSP taps. Plugs : 1/4 in. hex socket. Ambient Operating Temperature Rating: -40 C to +66 C ; (-40 F to +150 F). Material: Cast aluminum body, brass and stainless steel internal parts, NBR seals. EN1C-0015SZ20 R1002 2

Fig. 1. V5197A flow curves at stated pressure drops with flow adjustment set at 25%. Fig. 3. V5197A flow curves at stated pressure drops with flow adjustment set at 75%. Fig. 2. V5197A flow curves at stated pressure drops with flow adjustment set at 50%. Fig. 4. V5197A flow curves at stated pressure drops with flow adjustment set at 100%. 3 EN1C-0015SZ20 R1002

Installation When Installing this product 1. Read these instructions carefully. Be sure to follow Warning information carefully. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced flame safeguard control technician. 4. After installation is complete, check out product Installing the V5197A Allow sufficient clearance for assembling the motor and linkage (if applicable), and for general serviceing. IMPORTANT Install the valve so the arrow on the valve body points in the gas flow direction. Make sure the two flange gaskets (not provided in) are properly positioned and seated at the inlet and outlet flange connections. operation as provided in these instructions. 1. Install the V5197 Valve so the arrow on the valve body points in the gas flow direction. Explosion Hazard and Electrical Shock Hazard. Can cause explosion, serious injury or death. 1. Turn off gas supply before starting installation. 2. Disconnect power supply for valve actuator (if applicable) before beginning installation. NOTE: Normally, the V5197 will be located downstream of the safety shutoff valve(s) in the gas train. More than one disconnection can be involved. 2. Connect the V5197 Valve to the safety shutoff valve (SSOV) using the bolts, nuts and lockwashers. NOTE: Tightening torque for flange nuts/bolts: 34 Nm (25 ft-lb) 3. Assemble the downstream gas piping: 4. Mount the the selected actuator on the V5197 Valve and secure the actuator to the mounting bracket. 5. Wire the selected actuator according to instructions. 6. Restore power to the system. 7. Test proper wiring of the actuator before gas is supplied to gas train. EN1C-0015SZ20 R1002 4

FO R US E ONLY WITH H ONEYWE LL FO R US E ONLY WITH H ONEYWE LL MAD E IN ITALY DCYYWW MAD E IN ITALY DCYYWW IMPORTANT 120 (4,724) 242 (9,531) 212,5 (8,369) 185 (7,283) 122 (4,807) 18 (,709) 235 = (9,252) = 18 (,709) V5197A xxxx GAS A/G/LP P MAX = 15 P SI /1BAR V5197A (DN65) Install the valve so the arrow on the valve body points in the gas flow direction. 120 (4,724) 242 (9,531) 220 (8.664) 200 (7,874) 122 (4,807) 100 (3,937) 100 (3,937) 19 (,748) 235 = (9,252) = 19 (,748) V5197A xxxx GAS A/G/LP P MAX = 15 P SI /1BAR V5197A (DN80 Fig. 6. V5197A Firing Rate Gas Valve dimensions in mm. (in). 5 EN1C-0015SZ20 R1002

CHECKOUT AND OPERATION Checkout Explosion Hazard and Electrical Shock Hazard. Can cause explosion, serious injury or death. 1. Do not allow fuel to accumulate in the combustion chamber for longer than a few seconds without igniting. An explosive mixture can result. 2. Do not put the system into service until you have satisfactorily completed the following Valve Leak Test, all applicable tests described in the Checkout section of the instructions for the flame safeguard control, and any other tests required by the burner manufacturer. 3. All tests must be performed by a trained, experienced flame safeguard control technician. 4. Close all manual fuel shutoff valvesas soon as trouble occurs. After the installation is completed, cycle the valve several times with the manual fuel shutoff cock closed. Make sure the valve and actuator function properly. Perform the Valve Leak Test before putting the valve into service. Valve Leak Test This is a test for checking the leakage tightness of the firing rate gas valve only. It should be performed only by trained, experienced flame safeguard control technicians during the initial startup of the burner system, or whenever the valve is replaced (see Service Information section). It is recommended that this test also be included in the scheduled inspection and maintenance procedures. SERVICE INFORMATION Explosion Hazard and Electrical Shock Hazard. Can cause explosion, serious injury or death. 1. Turn off the gas supply and disconnect all electrical power to the valve actuator before servicing. 2. Properly position and seat the gaskets in ends of the valve body to prevent a hazardous gas leak. IMPORTANT Only trained, experienced flame safeguard control technicians should attempt to service or repair flame safeguard controls and burner assemblies. Scheduled Inspection and Maintenance Set up and follow a schedule for periodic inspection and maintenance for the burner, all other controls and the valves. It is recommended that the valve leak test in the Operation and Checkout section be included in this schedule. Refer to the instructions for the primary safety control and safety shutoff valve(s) for more informati NOTE: Additional leakage and closure tests may be required for other gas train components (for example, safety shutoff valves [SSOV]). 1. Close the downstream manual gas valve(s). 2. Energize the valve train to apply gas pressure. 3. Test with good quality leak detection spray. 4. Restore the system to normal operation. Operation A V5197A Firing Rate Gas Valve is operated by an actuator. The valve opens counterclockwise and closes clockwise. When closed, the valve does not totally seal off the gas flow and has no safety shutoff function. For further information, refer to the actuator instructions. Make sure that the actuator does not force the V5197 Valve beyond the limits of the valve stroke (90 degrees). This can damage or destroy the valve position indicator setscrew. EN1C-0015SZ20 R1002 6

7 EN1C-0015SZ20 R1002

Honeywell Honeywell Burner Boiler Control Center Europe Satronic AG Honeywell-Platz 1 CH-8157 Dielsdorf Switzerland Phone +41 1 855 22 11 Fax +41 1 855 22 22 Honeywell UGV Valves s.r.l. Via Ferrero 10090 CASCINE-VICE RIVOLI (TO) Italy Phone +39 (0)11 957 83 11 Fax +39 (0)11 957 83 22 EN1C-0015SZ20 R1002 8