IMPALA CONTROL PANEL CONVERSION KIT an ISO 9001:2008 Registered Company REV E 4/13/ IMPALA CNTRL PNL INST PG 1 OF 16

Similar documents
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

CHEV PICK-UP

OMS P/N: Rev.: B. Description OMS: ASSY BACKUP POD 6.0. DCR# 3137 Date: Operation: Special Instructions: TQC. Torque.

OEM Manual. MODEL ½ Digit DRUM SCALE

Model 130M Pneumatic Controller

Propane Conversion Kit Instructions

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Instructions for High Altitude Conversion

Kit Details Air Lift Performance HARDWARE LIST STOP!

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

2019 MADONE ASSEMBLY MANUAL

Operator: Save these instructions for future use!

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

Paddle Bar Replacement

Operator: Save these instructions for future use!

Wickets Installation Laundry Equipment Specific Installation Instructions 5/22/2009

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

Shimano Di2 Installation on S5

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Conversion instructions from natural gas to propane

Tripod Setup Guide (M-TPx)

Operator: Save these instructions for future use!

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System.

Tick Kit. Assembly Instructions

Halsey Taylor Owners Manual

TracPhone V7-IP Gyro Replacement Instructions

Assembly Instructions

Stand-Alone Bubble Detection System

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Float Operated Level Controllers

Lectric Cycles Mid-Drive Electric Motor Installation

2019 MADONE ASSEMBLY MANUAL

USER S INFORMATION MANUAL

*ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE)

Ventam 85 Installation & Commissioning Instructions

September 10, 2014 Revision 2. Puncher Unit-BE1/BF1/BG1/BH1 Service Manual

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Pressure Dump Valve Service Kit for Series 2300 Units

Powers Controls RC 195 Multiple Input Receiver- Controller

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Operator: Save these instructions for future use!

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Operator: Save these instructions for future use!

LENNOX SLP98UHV DIAGNOSTIC CODES

/2004 US/CA

Installation Instructions

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

TECHNICAL DATA ZTR Model 312

ServicePlus S21R & S27R Series 2 Installation Instructions

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

EOS LED Pendant Mounted Luminaire

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Installation Instructions

Operator: Save these instructions for future use!

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

GEN20AD-GEN20AL-GEN18AN

HS653 Negative Pressure Ventilation Controller

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Pressure Dump Valve Service Kit for Series 3000 Units

2 pcs. 1pc. 4 pcs. 4 pcs. 4 pcs. 4 pcs.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Congratulations, once again, on buying an E RIDER Model 18!!!!

USE AND MAINTENANCE LIGHT TOWER

P14 Series Pressure Actuated Mechanical Sequencer

2 pcs. 1pc. 3 pcs. 3 pcs. 1pc. 3 pcs.

K Page 1 of 48 Air Intake - Pg. 17

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45

Preferred Instruments Danbury, CT USA

Halsey Taylor Owners Manual

Operator: Save these instructions for future use!

Installation Instructions - Electric Aluminum Drive Systems for Arm Sets to 22 Electric Arm Systems , ,

OWNER'S MANUAL LOCK-N-LOAD BULLET FEEDER (PISTOL)

1.0 - OPENING AND CLOSING THE DOOR

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

Installation Instructions Air Compressor Part # 2780, 2781

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Butler Parachute Systems, Inc

Installation Instructions - Electric Steel Drive Systems for Arm Sets to ,

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

OWNER'S MANUAL FREE FALL ROPE AND CHAIN ANCHOR WINCH. 12 Volt Powered Winch Power-In / Freewheel-out operation. 36', 41' and 46' Class Anchor Winch

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Transcription:

an ISO 9001:2008 Registered Company 1961-62 IMPALA CONTROL PANEL CONVERSION KIT 471062 20 30 40 50 60 70 80 90 100 110 120 C T E M P EF F U E L DEF AIR 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 1 OF 16

Table of Contents PAGES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. COVER TABLE OF CONTENTS PACKING LIST/ PARTS DISCLAIMER REMOVING OEM CONTROL PANEL & SLIDE POT MODIFICATIONS SLIDE POT ASM MOUNTING CLAMP INSTALLATION SLIDE POT ASM FIGURES 1,2 & 3 DASH/FLR/DEF SLIDE POT ASM INSTALLATION FIGURES 4 CONTROL HARNESS FIGURES 5 & 5a COLD/HOT SLIDE POT ASM INSTALLATION & CONTROL HARNESS FIGURES 6 & 6a CONTROL HARNESS CONT. & OFF/ HI SLIDE POT ASM INSTALLATION FIGURES 6b & 7 CONTROL HARNESS FIGURES 7a & 7b CONTROL HARNESS CONT. & FIGURE 8 & 9 FINAL STEPS CONT. FIGURE 10 FINAL STEPS 12. CONTROL PANEL CALIBRATION PROCEDURE 13. CONTROL PANEL CALIBRATION PROCEDURE CONT. 14. WIRING DIAGRAM 15. OPERATION OF CONTROLS 16. CONTROL PANEL KIT PACKING LIST 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 2 OF 16 2

CONTROL KIT PACKING LIST No. QTY. PART No. DESCRIPTION CONTROL KIT 471062 1. 2. 3. 4. 5. 6. 3 1 3 3 5 1 112002-SUA 232002-VUA 65976-VUE 491010-VUR 21301-VUP 231520 SLIDE POT ASM GEN IV UNIVERSAL CONTROL HARNESS 3/16 PUSH-ON RING SLIDE POT CLAMP 4 TIE WRAP GROUND WIRE ** BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT. PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS, VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS. 1 2 3 4 5 6 3 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 3 OF 16

REMOVING OEM CONTROL PANEL CONTROL PANEL CONVERSION INSTRUCTIONS FOR 1961-62 IMPALA w/ AC REMOVE THE (4) OEM LEVER KNOBS AND THE (4) OEM MOUNTING SCREWS FROM INSTRUMENT PANEL OF DASH. SEE FIGURE 1 BELOW. DISCONNECT CABLES AND WIRES FROM BACK OF CONTROL PANEL. REMOVE THE CONTROL PANEL FROM BEHIND THE DASH. 20 30 40 50 60 70 80 90 100 110 120 C TEMP E F (4) LEVER KNOBS FU EL DEF AIR REMOVE (4) OEM SCREWS FIGURE 1 SLIDE POT ASSEMBLY MODIFICATIONS LOCATE THE THREE SLIDE POT ASSEMBLIES, AND USING A PAIR OF WIRE CUTTERS, CUT SLIDE POT ACTUATOR RODS AS SHOWN BELOW IN FIGURE 2. CUT AT EACH SIDE OF HOLE AS SHOWN SLIDE POT ACTUATOR ROD FIGURE 2 CUT ALL THREE SLIDE POT ASSEMBLIES AT 3RD HOLE (REMOVE SHADED PORTION) SLIDE POT ASSEMBLY MOUNTING CLAMP INSTALLATION INSTALL SLIDE POT ASM MOUNTING CLAMPS. SEE FIGURE 3 BELOW. SLIDE POT ASM MOUNTING CLAMP SLIDE POT ASM FIGURE 3 ORIENT CLAMPS THE SAME DIRECTION FOR ALL (3) SLIDE POT ASSEMBLIES ORIENT SLIDE POT ASSEMBLIES AS SHOWN AND INSTALL MOUNTING CLAMPS AS SHOWN. (NOTE: ORIENT CLAMPS IN RELATION TO THE (3) HOUSING SNAPS ON SLIDE POT ASSEMBLY) 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 4 OF 16 4

SLIDE POT ASSEMBLY INSTALLATION DASH/FLR/DEF SLIDE POT ASSEMBLY INSTALL SLIDE POT ASM ON THE DASH/FLR/DEF LEVER. SEE FIGURE 4, BELOW. INSTALL SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD ON LEVER. SEE FIGURE 4, BELOW. SECURE THE SLIDE POT ASM TO THE CONTROL PANEL USING THE OEM SCREW IN THE OEM CABLE CLAMP MOUNTING LOCATION. SEE FIGURE 4 BELOW. SINCE THE SLIDE POT ASSEMBLY CAN SLIDE BACK AND FORTH IN CLAMP BEFORE SCREW IS TIGHTENED, POSITION SLIDE POT ASSEMBLY SUCH THAT THE FLAT PART OF THE ROD IS AS CLOSE TO FLUSH AS POSSIBLE WITH THE END OF HOUSING AT THE LEVER S INNER MOST POSITION. SEE FIGURE 4, BELOW. SECURE SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD USING 3/16 PUSH-ON RING AS SHOWN IN FIGURE 4, BELOW. DASH/FLR/ DEF LEVER END OF ROD FLAT SECTION END OF HOUSING 1/8 MAX FIGURE 4 OEM SCREW 3/16 PUSH-ON RING FLUSH ROD SHOWN IN APPROX. INNER MOST POSITION 5 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 5 OF 16 NOTE: DO NOT ALLOW ROD TO SEPARATE HOUSING WHEN ROD IS IN INNER MOST POSITION.

CONTROL HARNESS LOCATE THE CONTROL PANEL WIRE HARNESS AND PLUG THE CORRESPONDING WIRES INTO THE CORRECT SLIDE POT ASSEMBLY AS SHOWN IN FIGURE 5 BELOW. RED WHT/YEL WHT FIGURE 5 DASH/FLR/DEF SLIDE POT ASSEMBLY ONCE WIRES ARE CORRECTLY PLUGGED INTO SLIDE POT ASSEMBLY, SECURE WIRES TO THE SLIDE POT ASSEMBLY USING TIE WRAPS (SUPPLIED). SEE FIGURE 5a BELOW. THE TIE WRAP MUST BE LOCATED BETWEEN THE END OF THE WIRE JACKET AND THE STEP IN THE SLIDE POT HOUSING FORCING A BEND IN EACH WIRE AS THEY PASS OVER THE STEP IN SLIDE POT HOUSING. HEAD OF TIE WRAP MUST FALL ON EDGE OF HOUSING AS SHOWN TO REMAIN TIGHT. ENSURE THAT THE TIE WRAPS ARE SNUG ENOUGH THAT THE WIRES CANNOT MOVE. SEE FIGURE 5a. FORCE BEND IN WIRES OVER STEP TIE WRAP WIRE JACKET WIRE JACKET STEP IN SLIDE POT HOUSING FIGURE 5a TIE WRAP 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 6 OF 16 6

COLD/HOT SLIDE POT ASSEMBLY INSTALL SLIDE POT ASM ON THE COLD/HOT LEVER. SEE FIGURE 6, BELOW. INSTALL SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD ON LEVER. SEE FIGURE 6, BELOW. COLD/HOT LEVER SECURE THE SLIDE POT ASM TO THE CONTROL PANEL USING THE OEM SCREW IN THE OEM CABLE CLAMP MOUNTING LOCATION. SEE FIGURE 6, BELOW. SINCE THE SLIDE POT ASSEMBLY CAN SLIDE BACK AND FORTH IN CLAMP BEFORE SCREW IS TIGHTENED, POSITION SLIDE POT ASSEMBLY SUCH THAT THE FLAT PART OF THE ROD IS AS CLOSE TO FLUSH AS POSSIBLE WITH THE END OF HOUSING AT THE LEVER S INNER MOST POSITION. SEE FIGURE 4, PAGE 5. FIGURE 6 SECURE SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD USING 3/16 PUSH-ON RING AS SHOWN IN FIGURE 6, BELOW. CONTROL HARNESS 3/16 PUSH-ON RING OEM SCREW LOCATE THE CONTROL PANEL WIRE HARNESS, PLUG THE CORRESPONDING WIRES INTO THE CORRECT SLIDE POT ASSEMBLY AS SHOWN IN FIGURE 6a, BELOW. FIGURE 6a 7 COLD/HOT SLIDE POT ASSEMBLY RED WHT/RED WHT 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 7 OF 16

CONTROL HARNESS CONT. ONCE WIRES ARE CORRECTLY PLUGGED INTO SLIDE POT ASSEMBLY, SECURE WIRES TO THE SLIDE POT ASSEMBLY USING TIE WRAPS (SUPPLIED). SEE FIGURE 6b, BELOW. THE TIE WRAP MUST BE LOCATED BETWEEN THE END OF THE WIRE JACKET AND THE STEP IN THE SLIDE POT HOUSING FORCING A BEND IN EACH WIRE AS THEY PASS OVER THE STEP IN SLIDE POT HOUSING. HEAD OF TIE WRAP MUST FALL ON EDGE OF HOUSING AS SHOWN TO REMAIN TIGHT. ENSURE THAT THE TIE WRAPS ARE SNUG ENOUGH THAT THE WIRES CANNOT MOVE. SEE FIGURE 6b. FORCE BEND IN WIRES OVER STEP TIE WRAP WIRE JACKET WIRE JACKET STEP IN SLIDE POT HOUSING TIE WRAP FIGURE 6b OFF/HI SLIDE POT ASSEMBLY INSTALL SLIDE POT ASM ON THE OFF/ HI LEVER. SEE FIGURE 7, BELOW. INSTALL SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD ON LEVER. SEE FIGURE 7, BELOW. SECURE THE SLIDE POT ASM TO THE CONTROL PANEL USING THE OEM SCREW IN THE OEM CABLE CLAMP MOUNTING LOCATION. SEE FIGURE 7, BELOW. SINCE THE SLIDE POT ASSEMBLY CAN SLIDE BACK AND FORTH IN CLAMP BEFORE SCREW IS TIGHTENED, POSITION SLIDE POT ASSEMBLY SUCH THAT THE FLAT PART OF THE ROD IS AS CLOSE TO FLUSH AS POSSIBLE WITH THE END OF HOUSING AT THE LEVERíS INNER MOST POSITION. SEE FIGURE 4, PAGE 5. SECURE SLIDE POT LEVER PUSH ROD ONTO OEM CABLE MOUNTING STUD USING 3/16 PUSH-ON RING AS SHOWN IN FIGURE 7, BELOW. OFF/HI LEVER FIGURE 7 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 8 OF 16 OEM SCREW 3/16 PUSH-ON RING 8

CONTROL HARNESS LOCATE THE CONTROL PANEL WIRE HARNESS AND PLUG THE CORRESPONDING WIRES INTO THE CORRECT SLIDE POT ASSEMBLY AS SHOWN IN FIGURE 7a, BELOW. RED WHT/GRN WHT FIGURE 7a OFF/HI SLIDE POT ASSEMBLY ONCE WIRES ARE CORRECTLY PLUGGED INTO SLIDE POT ASSEMBLY, SECURE WIRES TO THE SLIDE POT ASSEMBLY USING TIE WRAPS (SUPPLIED). SEE FIGURE 7b, BELOW. THE TIE WRAP MUST BE LOCATED BETWEEN THE END OF THE WIRE JACKET AND THE STEP IN THE SLIDE POT HOUSING FORCING A BEND IN EACH WIRE AS THEY PASS OVER THE STEP IN SLIDE POT HOUSING. HEAD OF TIE WRAP MUST FALL ON EDGE OF HOUSING AS SHOWN TO REMAIN TIGHT. ENSURE THAT THE TIE WRAPS ARE SNUG ENOUGH THAT THE WIRES CANNOT MOVE. SEE FIGURE 7b. FORCE BEND IN WIRES OVER STEP TIE WRAP WIRE JACKET STEP IN SLIDE POT HOUSING FIGURE 7b 9 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 9 OF 16

CONTROL HARNESS CONT. USING THE SUPPLIED TIE-WRAPS, TIE THE WIRES TO THE CONTROL PANEL AS SHOWN IN FIGURE 8 BELOW. CONFIRM THAT WIRES ARE SECURED AND DO NOT INTERFERE WITH LEVER OPERATION OR SLIDE POT ASSEMBLY. NOTE: TIE THE UNUSED WIRE TO THE CONTROL PANEL APPROXIMATELY AS SHOWN, ENSURE THAT THE WIRE DOES NOT INTERFERE WITH LEVERS OR SLIDE POT ASSEMBLIES. UNUSED RED, WHT/BLUE, WHT WIRE TIE WRAP FIGURE 8 FINAL STEPS RE-INSTALL CONTROL PANEL IN DASH. ONCE CONTROL PANEL IS INSTALLED, INSTALL THE (4) MODE LEVER KNOBS AS SHOWN IN FIGURE 9 BELOW. NOTE: THE FIRST LEVER () WILL NOT BE USED. AIR DEF 20 30 4050607080 90 100 110 120 C INSTALL KNOBS AS SHOWN TEMP E F (4) LEVER KNOBS FU EL AIR DEF SECURE USING(4) OEM SCREWS FIGURE 9 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 10 OF 16 10

FINAL STEPS CONT. PLUG THE WIRING HARNESS INTO THE ECU MODULE ON SUB CASE. SEE FIGURE 10 BELOW. WIRE ACCORDING TO WIRING DIAGRAM ON PAGE 14. CONTROL PANEL CALIBRATION PROCEDURE AND OPERATION INSTRUCTIONS: CALIBRATING THE CONTROL PANEL WILL SET THE RANGE OF TRAVEL FOR THE SLIDE POTS CONNECTED TO THE OEM CONTROL PANEL LEVERS. PERFORMING THIS PROCEDURE WILL SET THE LIMITS OF THE SLIDE POTS AT THEIR HIGHEST AND LOWEST POINTS LOCATE THE GRAY WIRE WITH AN UNUSED CONNECTOR IN THE WIRING HARNESS NEAR THE TWO CABLE HARNESS RELAYS. THE WIRE IS LABELED PRGM ON THE WIRING DIAGRAM ON PAGE 14. IT WILL BE NECESSARY TO GROUND THE GRAY WIRE FOR APPROXIMATELY FIVE SECONDS WHILE MOVING THE CONTROLS SO IT IS SOMETIMES HELPFUL TO ATTACH ONE END OF THE WHITE JUMPER WIRE TO THE VEHICLE'S GROUND (FOR EXAMPLE THE CHASSIS) AND HAVE THE OTHER END READY TO CONNECT TO THE GRAY PRGM WIRE WHEN THE PROCEDURE REQUIRES IT. TO CALIBRATE THE CONTROL PANEL FOLLOW THE CALIBRATION PROCEDURES ON PAGE 12 & 13. PLUG FROM CONTROL WIRING HARNESS PLUG 232002-VUA FROM WIRING HARNESS 232001-VUR FIGURE 10 11 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 11 OF 16

Control Panel Calibration Procedure On Vintage Air Gen IV systems using factory controls, it is necessary to calibrate the system to your specific control panel. This procedure ensures that the stroke of your control panel levers or knobs is translated into precise control of the fan speed, temperature blend and mode door position. Please carefully read and understand these procedures before beginning. The procedure may be repeated as many times as necessary to get it right. In preparation for calibration, you will need to attach the supplied white ground jumper wire to a suitable chassis ground. This jumper wire must be easily connected to the gray programming wire located in the main Gen IV wiring harness next to the relays. During the calibration procedure, you will connect the white jumper to the gray program wire, which will teach the Gen IV ECU the upper limits of the control levers or knobs. The blower will momentarily change speeds, signaling that the upper limits have been learned. You will move the levers or knobs to opposite extreme positions of their travel and then disconnect the white jumper. The blower will again change speeds, signaling that the lower limits have been learned and that the calibration procedure is complete. White Jumper Cable Gray Program Wire 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 12 OF 16 12

START Control Panel Calibration Procedure (Cont.) OFF ON 1. Turn on the ignition switch (Do not start the engine). AIR 2. Move the control levers/knobs to the position shown. DEF 3. Connect the white jumper wire to the gray program wire. Wait for the blower speed to change (Approximately 5 seconds). DEF 4. Move the control levers/knobs to the positions shown. AIR 5. Disconnect the white jumper wire from the gray program wire. The blower speed will change, indicating completion of the calibration procedure. 13 6. Confirm proper operation of controls. Repeat procedure if necessary. When finished, tape over program wire connector with electrical tape to prevent accidental contact with chassis ground. 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 13 OF 16

232007-VUR JF8 TAN ORA BLK WHT RED WHT/RED WHT/YEL WHT/GRN AC ANNUNCIATOR BACKLIGHT POS BACKLIGHT NEG GND 5V-SW TEMP WIPER MODE WIPER WIPER Wiring Diagram VIEWED FROM WIRE SIDE PRE-WIRED 232002-VUA A/C (IF USED) GEN IV ECU GEN IV WIRING DIAGRAM REV D, 5/6/2014 TEMP MODE *** WIDE OPEN THROTTLE SWITCH (OPTIONAL) PROGRAM * DASH LAMP (IF USED) ** CIRCUIT BREAKER 30 AMP ER CONTROL VALVE Dash Lamp Is Used Only With Type 232007-VUR Harness. Warning: Always Mount Circuit Breaker As Close to the Battery As Possible. (NOTE: Wire Between Battery and Circuit Breaker Is Unprotected and Should Be Carefully Routed to Avoid a Short Circuit). Wide Open Throttle Switch Contacts Close Only at Full Throttle, Which Disables A/C Compressor. 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 14 OF 16 14

OPERATION OF CONTROLS NOTE: WHEN BATTERY POWER IS FIRST CONNECTED TO THE ECU, THE COMPUTER GOES THROUGH AN INITIALIZATION SEQUENCE. THIS INITIALIZATION MAY TAKE UP TO 30 SECONDS. DURING INITIALIZATION THE BLOWER WILL NOT OPERATE, BUT THE DOORS INSIDE THE UNIT WILL BE OPERATING. A LOW BATTERY OR DISCONNECTING THE BATTERY MAY ALSO TRIGGER A RE-INITIALIZATION. DURING START UP, A LOW BATTERY MAY DROP BELOW 7 VOLTS, TRIGGERING RE-INITIALIZATION. NOTE: ORIGINAL BLOWER SWITCH WILL NOT BE USED. BLOWER SPEED THIS LEVER CONTROLS THE BLOWER SPEED, FROM OFF TO HI THERMOSTAT LEVER THIS LEVER CONTROLS THE TEMPERATURE FROM HOT TO COLD MODE LEVER THIS LEVER CONTROLS THE MODE POSITIONS FROM DASH TO FLOOR TO DEFROST BLOWER SPEED THERMOSTAT LEVER AIR SYSTEM OFF DEF MODE LEVER BLOWER SPEED SLIDE THE LEVER UP OR DOWN TO SELECT DESIRE SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM SPEED) THERMOSTAT LEVER IN A/C MODE SLIDE THE AIR LEVER ALL THE WAY DOWN TO ENGAGE COMPRESSOR FOR MAXIMUM COOLING. (SLIDE LEVER UP OR DOWN TO ADJUST DESIRED TEMPERATURE) MODE LEVER SLIDE THE DEF LEVER ALL THE WAY UP FOR DASH MODE AIR DEF INSTALL KNOBS AS SHOWN AIR A/C MODE DEF BLOWER SPEED SLIDE THE LEVER UP OR DOWN TO SELECT DESIRE SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM SPEED) AIR BLOWER SPEED SLIDE THE LEVER UP OR DOWN TO SELECT DESIRE SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM SPEED) THERMOSTAT LEVER IN MODE SLIDE THE AIR LEVER ALL THE WAY UP FOR MAXIMUM ING. (SLIDE LEVER UP OR DOWN TO ADJUST DESIRED TEMPERATURE) 15 MODE LEVER SLIDE THE DEF LEVER TO THE CENTER FOR FLOOR MODE (SLIDE LEVER UP OR DOWN TO BLEND BETWEEN DESIRED MODE POSITIONS) MODE DEF THERMOSTAT LEVER IN DEF MODE SLIDE THE AIR LEVER ALL THE WAY DOWN TO ENGAGE COMPRESSOR FOR MAXIMUM COOLING. (SLIDE LEVER UP OR DOWN TO ADJUST DESIRED TEMPERATURE) MODE LEVER SLIDE THE DEF LEVER ALL THE WAY DOWN FOR DEFROST MODE (SLIDE LEVER UP OR DOWN TO BLEND BETWEEN DESIRED MODE POSITIONS) 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 15 OF 16 AIR DEF DEFROST MODE

CONTROL KIT PACKING LIST N o. Q TY. PART N o. DESC RIPTIO N CONTROL KIT 471062 1. 2. 3. 4. 5. 6. 3 1 3 3 5 1 112002-SUA 232002-VUA 65976-VUE 491010-VUR 21301-VUP 231520 SLIDE POT ASM GEN IV UNIVERSAL CONTROL HARNESS 3/16 PUSH-ON RING SLIDE POT CLAMP 4 TIE WRAP GROUND WIRE CHECKED BY: PACKED BY: DATE: 1 2 3 4 5 6 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST PG 16 OF 16