SITRANS F C MASSFLO. MASS flowmeters Sensor type MASS MC1 DN 50 - DN 100. Manual, supplement *083R9505* Order no.: FDK:521H1145

Similar documents
Flow Measurement SITRANS F C

SITRANS F C. Flow sensor SITRANS FCS400 3/157. At ordering the following fraction or standard density scales can be specified: Overview

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C

Coriolis MASS Flowmeters SITRANS FC300 DN 4. Operating Instructions 07/2010 SITRANS F

Coriolis flowmeters. SITRANS F C MC2 and MC2 Hygienic. Operating Instructions 10/2009 SITRANS F

C-Flow Coriolis Mass Flow Meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Pressure Measurement Single-range transmitters for general applications

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Level switches Series LD Vibrating fork level switch for liquids and solids

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Level transmitter LT 100

sitrans p Operating Instructions (de/en) Edition 03/2004

Orifice Plate Flow Meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

GA24 Technical Datasheet

Level switches Series LD Vibrating fork level switch for liquids and solids

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

SonoMeter 30 Energy Meters

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Torque Tube TB300 Digital Transmitters

SITRANS P measuring instruments for pressure

Mass Flow Meter (MFM) for Gases

T EK-COR 1100A Coriolis Mass Flowmeter

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

deltaflowc deltaflowc Venturi or Probe

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Monitoring device NTS 30

Types and approvals. Page 1/6. Data Sheet

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Flow metering in gases Introduction to COMBIMASS family

Integral type Differential pressure flowmeter VNT Series

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Mechanical Pressure Measurement

Expert Hydrostatic Level Transmitters

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Liquid level instruments BM 24 /BM 51

9700 Transmitter Submersible hydrostatic level transmitter

Instruction Manual Contact Pressure Vacuum Gauge

High-performance submersible pressure transmitter For level measurement Model LH-10

Coriolis Mass Flow Meter

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pro-V Multivariable Flowmeter

DK46 - DK800 Supplementary instructions

Pressure Measurement Single-range transmitters for general applications

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Flow Measurement SITRANS F X

4/2 way Pneumatic Solenoid Valve

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

2-port and 3-port valves PN 16

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure transmitters EMP 2

FPD175 Compact orifice carrier assembly

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

High-performance submersible pressure transmitter For level measurement Model LH-10

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Air Eliminators and Combination Air Eliminators Strainers

2-Port Seat Valves with Flange, PN 16

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Gas density monitor With integrated transmitter Model GDM-100-TI

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Electro-Pneumatic Converter YT-940 SERIES

Variable area flowmeter F VA 250

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Ultrasonic level transmitter and indicator

Pressure controls for hydro carbons, zone II applications, Type KPE

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

2-Port Seat Valves with Flange, PN 16

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

3-port seat valves with externally threaded connection, PN 16

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Instruction Manual Differential Pressure Transmitter

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Flow Measurement SITRANS F X

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Transcription:

s Manual, supplement SITRANS F C MASSFLO MASS flowmeters [ ] Order no.: FDK:521H1145 SFIDK.PS.28.P3.2 - A5E253681 *83R955*

Contents Page Introduction... 2 Siemens Flow Instruments range of coriolis mass flowmeters... 3 Technical data... 4 Pressure drop... 4 Meter uncertainty... 5 Installation... 6 Dimensions... 1 Remote design, flanged construction, DIN/ANSI... 1 Remote design, food industry fittings, DIN 11851... 1 Remote design, Tri-clamp ISO 2852... 11 Electrical connection...12 Electrical connection for Ex application... 12 Build-up code for coriolis mass flowmeter... 13 Ordering... 14 Signal converter... 14 Signal converter 19"...15 Cables and connectors... 15 SENSORPROM memory unit... 15 Introduction Use of flowmeter, type MC1.. according to specifications The flowmeter type MC1.. serve to conduct liquids and gaseous media for measuring purposes. Use according to specifications covers: Use within technical limits. Consideration of liquid specifications and references. Consideration of specifications as to installation, commissioning and maintenance. It is inappropriate to: Use the meter as elastic equalization in pipe systems to compensate for e.g. pipe displacement, pipe vibration, expansion etc. Use the meter as footboard for installation purposes. Use the meter as support of external loads like pipes etc. Change the meter in any way like e.g. decomposition of material in connection with processing, welding and use of accessories and spare parts not approved by Siemens Flow Instruments. If the meter is not used according to the specifications, the manufacturer cannot be held responsible for any damage occurred. Technical limits: Allowed pressure and allowed temperature must be the pressure and temperature specifications stated in the user manual or the handbook. Always note the specifications on the product label. Never go beyond the maximum operation temperature specified for the particular unit. Permissible liquids are liquids where it has been technically proven or where the user knows from experience and thus can guarantee that neither wetted parts, process connections, flow dispenser nor measuring pipe are influenced/damaged by the chemical and physical properties of the liquid for the estimated lifetime of the products (at least 15 years). Flow and density must be within the specified limits. Please note! If there is a risk that some of the meter parts may be influenced or damaged by the liquid, the flowmeter MC1xxxxxxx1 must be replaced by MC1xxxxxxx2. The latter two types are provided with a special enclosure protecting against fluid leakage. When using the flowmeters in applications not in conformity with the specifications, the user is responsible for any damage that might occur. Only pressures 4 bar are allowed. * Refer to the flowmeter specification and user s manual to see the measuring technical properties and measuring technical use. 2 SFIDK.PS.28.P3.2

Siemens Flow Instruments range of coriolis mass flowmeters Dimension DN 5, 65, 8 1 Size [mm] Measuring range [kg/h] - 192. kg/h at 2 bar P drop at density 1 g/cm 3 Version Materials [wetted] 2 - pipe system SS 1.4571 or Hastelloy C4 Liquid temperature [ C] 5 to +18; EEx: 2 to +18 Liquid pressure [bar] max. 1 Enclosure Housing SS 1.431 Connection box 1, aluminium IP 67 Ex-approval II 1/2 G EEx em [ib] II C T2 - T6 Double pipe MASS MC1 SFIDK.PS.28.P3.2 3

Technical data Versions mm 5 65 8 1 inch 2 2 1 / 2 3 4 Inside pipe diameter 2 x mm 25. 33.7 38. 48.3 Pipe wall thickness mm 1.5 1.5 2. 2.6 Mass flow measuring range at pressure drop of 2 bar at 1 g/cm 3 kg/h 42.6 87. 113.4 192. Density g/cm 3.5-3.5 Fraction e.g. Brix Brix - 1 Temperature Standard 5 to +18 C Ex 2 to +18 C Liquid pressure measuring pipe Stainless steel (DIN 2413, 2 C) PN 1 Materials Measuring pipe SS 1.4571 or Hastelloy C4 Flange SS 1.4571 or Hastelloy C4 Enclosure IP 67 Enclosure material/connection box 1.431 / aluminium Process connections See dimensions Electrical connections Screw terminals, Pg 13.5 Cable length m Max. 3 Cable connection 5 2.35 mm 2 twisted and screened in pairs, ext. 12 mm Ex-version ATEX 1388X II 1/2 EEx em [ib] II C T2-T6 Weight approx. kg See dimensions Pressure drop Pressure drop for viscosity 1 cst. Mass flow rate [kg/min.] 4 SFIDK.PS.28.P3.2

Meter uncertainty 5% 5% 1% DN 5 2.13 kg/h 21.3 kg/h 42.6 kg/h DN 65 4.35 kg/h 43.5 kg/h 87. kg/h DN 8 5.67 kg/h 56.7 kg/h 113.4 kg/h DN 1 9.6 kg/h 96. kg/h 192. kg/h E = ± (,15) 2 z 1 + ( ) 2 qm E = Error [%] Z = Zero point error [kg/h] qm = Mass flow [kg/h] Q max. at 2. bar pressure loss at 1 g/cm 3 Measuring pipe type MASS MC1 Measuring pipe version DN 5 DN 65 DN 8 DN 1 Number of measuring pipes 2 2 2 2 Mass flow: Linearity error % of rate.15.15.15.15 Repeatability error % of rate.1.1.1.1 Max. zero point error [kg/h] 5.52 11.34 14.76 24.96 Density: (Standard) [g/cm 3 ].5.5.5.5 Density error (Extended) [g/cm 3 ].1.1.1.1 Range [g/cm 3 ].5-3.5.5-3.5.5-3.5.5-3.5 Repeatability error [g/cm 3 ].1.1.1.1 Temperature: Error [ C] 1. 1. 1. 1. Brix: Error [ Brix].21.21.21.21 Reference conditions (ISO 914 and DIN/EN 2914) Flow conditions Fully developed flow profile Temperature of medium 2 C ± 2K Ambient temperature 2 C ±2 K Liquid pressure 2 ± 1 bar Density.997 g/cm 3 Brix 4 Brix Supply voltage Un ±1% Warming-up time 3 min. Cable length 5 m between converter and sensor SFIDK.PS.28.P3.2 5

Installation Assembly and installation flowmeter primary Inspection Before installing the flowmeter primary, check for mechanical damage due to possible improper handling during shipment. All claims for damage are to be made promptly to the shipper. Installation requirements/system design information The MASS MC1 is suitable for in- and outdoor installations. The standard instrument meets the requirements of Protection Class IP 67. The primary is bidirectional and can be installed in any orientation. It is important to assure that the meter tubes are always completely filled with fluid. The corrosion resistance of the fluid wetted materials must be evaluated. The following points are to be considered during installation: The preferred flow direction is indicated by the arrow on the flowmeter primary. Flow in this direction will be indicated as positive (a forward/reverse flow calibration is available as on option). Installation orientation The MASS MC1 operates in all orientations. The optimal installation orientation is vertical with the flow upwards. Supports In order to support the weight of the flowmeter primary and to assure reliable measurements when external effects exist (e.g. vibrations), the primary should be installed in rigid pipelines. Two supports or hangers should be installed symmetrically and stress free in close proximity to the process connections. Shut off devices To conduct a system zero adjustment, shut off devices are required in the pipeline. - in horizontal installations at the outlet - in vertical installations at the inlet When possible, shut off devices should be installed both up- and downstream of the flowmeter primary. Inlet straight sections The mass flowmeter does not require any flow conditioning inlet straight sections. Care should be exercised to assure that any valves, gates, sight glasses etc. do not cavitate and are not set into vibration by the flowmeter primary. 6 SFIDK.PS.28.P3.2

System design information The presence of gas bubbles in the fluid may result in erroneous measurements, particularly in the density measurement. Therefore the flowmeter primary should not be installed at the highest point in the system. Advantageous are installations in low pipeline sections, at the bottom of a U-section in the pipeline (invert). Long drop lines downstream from the flowmeter primary should be avoided to prevent the meter tube from draining. The connecting pipelines should be axially centered to assure a stress free installation. The flowmeter primary should not come into contact with any other objects. Attachments to the housing are not permissible. When the cross-section of the connecting pipeline is larger than the flowmeter primary size, suitable standard reducers can be installed. If strong vibrations exist in the pipeline, they should be damped using elastic pipeline elements. The damping devices must be installed outside the supported flowmeter section and outside the section between the shut off devices. The direct connection of flexible elements to the flowmeter primary should be avoided. Make sure that any dissolved gases, which are present in many liquids, do not outgas. The back pressure at the outlet should be at least.2 bar. Assure that operation below the vapor pressure cannot occur when a vacuum exists in the meter tube or for fluids which boil readily. The flowmeter primary should not be installed in the vicinity of strong electromagnetic fields, e.g. near motors, pumps, transformers etc. When operating more than one meter in one or multiple interconnected pipelines, the meter primaries should be spaced distant from each other or the pipelines should be decoupled to prevent cross talk. Zero adjustment In order to adjust the zero under operating conditions it must be possible to reduce the flow rate ZERO while the meter tube is completely filled. A bypass line is optimal when the process cannot be shut down. It is important for accurate measurements that during the zero adjustment there are no gas bubbles in the flowmeter primary. It is also important that the pressure and temperature in the meter tube be the same as that which exists during operation. Zero adjustment with a by-pass line SFIDK.PS.28.P3.2 7

Installation Vertical installations The optimal installation orientation is a vertical installation with an upward flow as shown in the following figure. This has the advantage that any solids contained in the fluid will settle downward and gas bubbles will move upward out of the meter tube when the flow rate is zero. Additionally, it is easy to drain the meter tube. Deposits can thereby be avoided. Vertical orientation Horizontal orientation Horizontal installation Horizontal installation, self-draining Vertical installation, selfdraining (upward flow) Horizontal installation, self-draining, α 2 4 Installation in a drop line The installation recommendation shown in the following figure is only possible if a pipeline reduction or orifice with a smaller crosssection can be installed to prevent the flowmeter primary from being partially drained during the measurements. Installation in a drop line 8 SFIDK.PS.28.P3.2

Difficult installation locations The accumulation of air or gas bubbles in the meter tube can lead to increased inaccuracies. Some difficult installations are shown in the following figure. Installations at the highest point in the system (figure A) can result in the formation of air pockets which can lead to appreciable inaccuracies. Another difficult installation condition is immediately upstream of a free discharge (figure B) in a drop line. Note Check that the coordination between the flowmeter primary and the converter SENSORPROM unit is correct. The instruments which belong together have the same end characters on the Instrument Tag, e.g., X1 with Y1 or X2 with Y2. Pressure drop The pressure drop through the instrument is a function of the properties of the fluid and the flow rate. The Sizing Program can be used to calculate the pressure drop. Difficult installation conditions SFIDK.PS.28.P3.2 9

Dimensions Remote design, flanged construction, DIN/ANSI 8 142 8 G A G Flanges Flansch DIN 2633 DIN 2635 ANSI ANSI B16.5 B16.5 ISO 75 ISO 75 F Flow direction B L Meter size Process L connection size DIN 2635 DIN 2637 ANSI ANSI ANSI G*) F B A Weight Inch DN Inch DN PN 4 PN 1 CL 15 CL 3 CL 6 [kg] H 1½ 4 145 178 175 19 118 43 148 8 11 32 2 5 2 5 94 979 97 98 11 43 148 8 11 34 2½ 65 11 1148 1135 1145 1166 43 148 8 11 38 I 2 5 122 1259 125 126 1281 429 164 97 13 43 2½ 65 2½ 65 11 1148 1218 1145 1249 429 164 97 13 47 3 8 122 126 124 126 1282 429 164 97 13 5 J 2½ 65 133 1256 1365 1375 1396 456 186 18 14 56 3 8 3 8 122 126 124 126 1282 456 186 18 14 58 4 1 148 N/A 15 152 N/A 456 186 18 14 69 K 3 8 164 N/A 166 168 N/A 5 215 131 17 84 4 1 4 1 148 N/A 15 152 N/A 5 215 131 17 91 *) = For EEx add 54 mm All dimensions in mm. Remote design, food industry fittings, DIN 11851 8 142 8 Food industry Rohrverschraubung fittings DIN 11851 DIN 11851 Gewindestutzen G R Threaded stubs G Gewindestutzen Threaded stubs A F B Flow direction L L g Meter size Process connection size L g G*) F B A R Weight Inch DN [kg] H 1½ 4 Rd 65 x 1/6 125 7 43 148 8 11 233 28 (5) 2 5 Rd 78 x 1/6 915 7 43 148 8 11 177 3 2½ 65 Rd 95 x 1/6 166 8 43 148 8 11 254 34 I 2 5 Rd 78 x 1/6 123 7 429 164 97 13 291 4 (65) 2½ 65 Rd 95 x 1/6 178 8 429 164 97 13 227 44 3 8 Rd 95 x 1/6 1184 8 429 164 97 13 281 47 J 2½ 65 Rd 95 x 1/6 1316 8 456 186 18 14 319 54 (8) 3 8 Rd 95 x 1/6 1195 8 456 186 18 14 258 56 4 1 Rd 13 x 1/4 144 1 456 186 18 14 381 6 K 3 8 Rd 95 x 1/6 1632 8 5 215 131 17 41 82 (1) 4 1 Rd 13 x 1/4 146 1 5 215 131 17 314 86 *) = For EEx add 54 mm. All dimensions in mm. 1 SFIDK.PS.28.P3.2

Remote design, Tri-clamp ISO 2852 8 142 8 G R F A G Flow direction B L Meter size L G*) F B A R Weight Inch DN ±3 [kg] H 1½ 4 11 43 148 8 11 275 27 (5) 2 5 91 43 148 8 11 225 26 2½ 65 17 43 148 8 11 35 27 I 2 5 119 429 164 97 13 335 36 (65) 2½ 65 17 429 164 97 13 275 37 3 8 1176 429 164 97 13 328 38 J 2½ 65 134 456 186 18 14 378 45 (8) 3 8 1176 456 186 18 14 296 44 4 1 1445 456 186 18 14 43 46 K 3 8 1596 5 215 131 17 44 71 (1) 4 1 1445 5 215 131 17 365 69 *) = For EEx add 54 mm SFIDK.PS.28.P3.2 11

Electrical connection MASS 6 MASS MC1 81 82 83 84 85 86 87 88 89 9 91 92 Gnd 93 94 Gnd 87 88 Gnd 85 86 Gnd 95 96 Gnd Driver PT1 Pick up 1 Pick up 2 PT1 Electrical connection for Ex application MASS 6 and MASS MC1 in Ex application: e certified products (increased safety) to a certain voltage level can be connected to equipment in the safe area which are designed to guarantee no higher voltage than specified on the e certified equipment. For the MASS 6 / MC1 this means: All secondary circuits/terminals can be considered as limited circuits with non-hazardous voltage of max. 6 V. The MC1 sensor certified as e up to 6 V. This means that the MASS 6 and MC1 can be connected with no further approvals. Equipment connected to the signal outputs (current, pulse etc) must however obtain the same high degree of isolation from mains supply as the MASS 6 (Class 2 transformer or Class 1). MASS 6 Safe area MASS MC1 Ex zone 1 81 82 83 84 85 86 87 88 89 9 M6 M7 SE UT+ UT- SE S3 S4 SE S1 S2 SE IT+ IT- SE Driver PT1 Pick up 1 Pick up 2 PT1 12 SFIDK.PS.28.P3.2

Build-up code for coriolis mass flowmeter MC 1 X X X X XX X X A X D Design (primary/converter) Remote design... 1 EEx, remote design... 6 Certification Without... EN 124 3.1 B... A B Tube material 1.4571... 1 Hastelloy C4*)... 4 Measuring range [kg/h] Size Preferred process connection size - 42.6 H (DN 5)... H - 87. I (DN 65)... I - 113.4 J (DN 8)... J - 192. K (DN 1)... K Process connection size Meter size DN 4 1 ½"... 4 DN 5 2" H... 5 DN 65 2 ½" I... 65 DN 8 3" J... 8 DN 1 4" K... 1H Process connection type Flange DIN PN 4... Flange DIN PN 1**)... Flange ANSI 15 lb... Flange ANSI 3 lb... Flange ANSI 6 lb**)... Tri-Clamp ISO 2852... Sanitary thread DIN 11851... F H P Q R U V Housing Standard... 1 Reinforced safety cover against leakage... 2 Heating Standard... A Calibration Flow and density... Flow and extended density***)... Matched pair flow and density... Matched pair flow and extended density***)... Flow and Brix/plato***)... Matched pair flow and Brix/plato***)... Flow and fraction (specified by customer) contact Siemens Flow Instruments***)... Matched pair flow and fraction (specified by customer) contact Siemens Flow Instruments***)... C F V W R S T U Name plate Standard... D *) = Please contact Siemens Flow Instruments for delivery time, prefered process connections size for the particular meter will cut delivery time **) = Not possible with connection size DN 1 and meter size DN 1 ***) = Not possible with EEx version SFIDK.PS.28.P3.2 13

Ordering Signal converter Compact IP 67 Description Version Enclosure Code no. Symbol Signal converter MASS 6 for 115/23 V a.c. IP 67, fibrecompact and wall mounting 5/6 Hz glass reinforced FDK:83H222 polyamide 11-3 V d.c./ IP 67, fibre- 11-24 V a.c glass reinforced FDK:83H223 polyamide Signal converter MASS 6 inclusive 115/23 V a.c. IP 67, fibrewall mounting enclosure 5/6 Hz glass reinforced FDK:83H217 polyamide 11-3 V d.c./ IP 67, fibre- 11-24 V a.c glass reinforced FDK:83H218 polyamide Wall mounting kit Description Code no. Symbol Wall mounting unit for IP 67 version Wall bracket, 4 Pg 13.5 cable glands FDK:85U11 Spare parts for compact IP 67 Description Version Code no. Symbol Connection plate/pcb 115-23 V/ 12-24 V FDK:83H426 14 SFIDK.PS.28.P3.2

Signal converter 19" Standard version Description Version Supply voltage Code no. Symbol MASS 6 signal converter IP 2 1 current output 115-23 V.a.c./ version for 19" rack and panel 1 frq./pulse output 5/6Hz FDK:83H2 mounting including back plate*) 1 relay output 24 V a.c./d.c. FDK:83H21 3 current outputs 115-23 V.a.c./ 2 frq./pulse outputs 5/6Hz FDK:83H24 2 relay outputs 24 V a.c./d.c. FDK:83H25 MASS 6 signal converter IP 2 1 current output 115-23 V.a.c./ 19" version wall mounting 1 frq./pulse output 5/6Hz FDK:83H28 enclosure including back plate*) 1 relay output 24 V a.c./d.c. FDK:83H29 3 current outputs 115-23 V.a.c./ FDK:83H212 2 frq./pulse outputs 5/6Hz 2 relay outputs 24 V a.c./d.c. FDK:83H213 *) The use of MASS 6 in Ex applications makes it necessary to order a separate connections board. This must be swapped with the connections board supplied with the MASS 6. Wall mounting enclosure (With back plate/pcb for Ex) Description Code no. Symbol Wall mounting enclosure for MASS 6 19" version IP 65 (21 TE) FDK:83H4296 Back plates/pcb for 19" versions Description Enclosure Version Code no. Symbol Signal converter IP 2 19" 12-24 V FDK:83H4272 115-23 V Signal converter IP 2 for Ex application 19" 12-24 V FDK:83H4294 115-23 V Signal converter for wall mounting enclosure Wall 12-24 V FDK:83H4274 unit 115-23 V Signal converter for wall mounting enclosure, Walll 12-24 V FDK:83H4295 IP 65 for Ex application unit 115-23 V Cables and connectors Description Code no. Symbol Length Cable 1 m FDK:83H31 Standard cable between MASS 6 and MC1 25 m FDK:83H32 5 x 2 x,34 mm 2 twisted and screened in pairs 75 m FDK:83H33 Temperature range minus 2 C to plus 11 C 15 m FDK:83H34 SENSORPROM memory unit 2 kb SENSORPROM unit (Sensor serial no. must be specified by ordering) FDK:83H441 SFIDK.PS.28.P3.2 15

We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are always welcomed. Technical data subject to change without prior notice. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright Siemens AG 23 All Rights Reserved SIEMENS Flow Instruments A/S Nordborgvej 81 DK-643 Nordborg Order no.: FDK:521H1145-2 Printed in: Denmark