mass flowmeter approved by Weights and Measures for custody transfer

Similar documents
Pro-V Multivariable Flowmeter Model M22 In-line Vortex

C-Flow Coriolis Mass Flow Meters

Over 20,000 Strain Gage Target flowmeters installed since 1952.

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

780S Ultra High Purity Series

Truck-mounted Mass Flow Metering for LPG Delivery

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Pro-V Multivariable Flowmeter

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

T EK-COR 1100A Coriolis Mass Flowmeter

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Design Features. General Description

Features. Description

BUBBLER CONTROL SYSTEM

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Torque Tube TB300 Digital Transmitters

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

UNDERSTANDING, ACCELERATED

Coriolis Mass Flow Meter

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Level transmitter LT 100

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

COMPANY TRICOR CORIOLIS MASS FLOW METERS

Vehicle- or rack-mounted liquefied gas meters, pump supplied

analytical bulk flow distance FLOW level pressure temperature industrial communication

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features

Wafer type. the product

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Integral type Differential pressure flowmeter VNT Series

Level MEASUREMENT 1/2016

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Ultrasonic Flowmeter USZ 08

Deep Submersible Level Transducer Series 300DS

Ultra High Purity Model 780S

Mass Flow Controllers

Mass Flowmeters. Mass Flowmeters for Gases

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Vehicle-mounted meters, pump supplied

9700 Transmitter Submersible hydrostatic level transmitter

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

BUBBLER CONTROL SYSTEM

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Differential Pressure Transmiter

NEW VERSAFLOW CORIOLIS

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Flow metering in gases Introduction to COMBIMASS family

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Autocalibration Systems For In Situ Oxygen Analyzers

L3 Pressure and Level transmitter

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Level switches Series LD Vibrating fork level switch for liquids and solids

Autocalibration Systems for In Situ Oxygen Analyzers

Level switches Series LD Vibrating fork level switch for liquids and solids

deltaflowc deltaflowc Venturi or Probe

LPG DRIVER ATTENDED TRANSPORT LOADING

Drilling Efficiency Utilizing Coriolis Flow Technology

Micro Motion 7835 Series Density and Concentration Meters

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

THERMAL MASS FLOW MEASUREMENT FOR GASES

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Micro Motion 3098 Gas Specific Gravity Meter

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Turbine Flowmeters for Gas Applications

Steel-Mass Model 640S

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

HumiSys HF High Flow RH Generator

Precision Mass Flow Meters / Controllers for Liquids and Gases

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Vortex Meters for Liquids, Gas, and Steam

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Turbine Flowmeters for Gas Applications

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Online data sheet FLOWSIC30 GAS FLOW METERS

RCD - Ultra-Rugged Differential Pressure Flowmeter

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Turbine Flowmeters for Gas Applications (Metric)

Micro Motion 7812 Fiscal Gas Density Meter

200A Series ELECTRONIC LEVEL TRANSMITTER

Pneumatic high-pressure controller Model CPC7000

Automatic Isokinetic Sampler. ST5 Evo

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Pneumatic high-pressure controller Model CPC7000

Technology Solutions Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Transcription:

TS-613 Rev. C Coriolis Mass Flowmeters mxxxxxx mass flowmeter approved by Weights and Measures for custody transfer ISO 9001 Certified Manufacturing Facility DESCRIPTION Actaris has been a leader in custody transfer of fluids for more than 100 years. Now, custody transfer by Coriolis measurement has arrived. The Actaris Coriolis mass flowmeter is now Weights and Measures-approved by the National Conference on Weights and Measures and Measurement Canada, Legal Metrology Branch, for mass and volume custody transfer applications. Actaris currently offers six sizes of mass flowmeters with flow rates ranging from 6.8 to 5103 kg/min (15 to 10,000 lb/min). The Actaris mass flowmeter is custody transfer-approvable for fluids such as refined fuel products, aviation fuels, liquefied propane gases (LPG), agricultural liquids, solvents, alcohols, ammonia (NH 3 ) and others. DESIGN FEATURES Weights and Measures approval of mass flow technology is a significant step forward for custody transfer metering. Mass flow measurement is not affected by changes in viscosity, density, temperature or pressure, as are volumetric measurement systems. This results in more accurate delivery under changing climatic or process conditions. THE LEADER IN RELIABILITY AND PRECISION The Actaris patented, dual omega-shaped flow tube design is an unequaled combination of reliability and precision. Even if your application is not required to be certified, it is reassuring to know that the Actaris mass flowmeter manages your flow control with custody transfer precision. Measurement Canada and NTEP approved for mass and volume custody transfer applications No weigh scales...immediate savings from reduced installation costs...faster vehicle on-loading and off-loading No volumetric temperature compensation... this flowmeter measures mass directly More precise delivery of costly products under varying conditions, especially with products whose viscosity or density changes with temperature Multi-compartment loading with mass measurement accuracy (±0.15% of rate) Maximum filling of bulk containers Reduced maintenance...no moving parts

page 2 Mass Flow for Custody Transfer THE MASS MEASUREMENT ADVANTAGE Mass, length and time are the bases for all physical measurements. Fluid flow can be measured either by volume or mass. However, volume will vary with changes in temperature and pressure, whereas the mass of a fluid remains the same even when subjected to physical changes. This makes mass an ideal property for measuring fluid flow. A drum filled in the yard in January would hold 4.6 litres less than the same drum filled in July, yet they would weigh exactly the same. The Actaris mass flowmeter uses the Coriolis principle to measure mass flow of fluids. For this reason, density, pressure, temperature, viscosity and flow profile variations have no effect on the accuracy of the mass flowmeter's mass measurement. The mass flowmeter also directly measures density and temperature. These measurements, combined with the direct flow measurement, provide local or remote readouts of mass flow, density, temperature, % solids, solids flow and volume. FLOW The microprocessor-based DATAMATE 2100 is the process controller transmitter for the mass flowmeter. It provides a combination of process measurements, user flexibility and optional outputs, enabling you to select the optimum parameters for your specific operation. The DATAMATE 2100 is truly a versatile electronic device. Besides continuously displaying the total accumulated mass, it can be programmed to alternately display temperature, mass flow rate, volume and several other measurement varibles. Based upon your input, it will display temperature in either Celsius or Farenheit, mass in pounds or kilograms and time in seconds, minutes or hours. A variety of display choices are offered for selection and compatibility with your operation. The programmable operating variables are easily accessible from the keypad at the front panel. A liquid crystal display window with 40 characters on two lines is positioned above the keyboard for viewing each function. The system is adapable to meet specific output requirements. Plug-in modules are used to configure the basic unit for processes requiring remote outputs such as scaled pulse and/or 4 20 ma. All accumulated data are retained in memory through battery-backed RAM. Have a mass flow custody transfer application in mind? Approval is simple... Obtain pre-approval before purchase by submitting a flow chart such as this to Actaris with all fluids identified and characterized. Then receive final authorization following installation and proving. Contact your Actaris representative for assistance! Matching the mass flowmeter with your fluid processing system has never been easier. With no straight piping runs required, the flowmeter can be installed directly in-line. Installation is further simplified because the Actaris mass flowmeter has one of the lowest pressure drops in the industry, resulting in pump horsepower conservation. Best of all, the Actaris mass flowmeter is maintenancefree. The rugged design, with no moving parts, is certain to minimize downtime. See Page 5 for complete specifications for the entire line of Actaris Coriolis mass flowmeters.

page 3 Additionally, the DATAMATE 2100 is completely self-diagnostic and has RS-422 interface capability for communication with an external computer or printer interface. PRECISION LOADING, FILLING AND BATCHING BY MASS 3A-AUTHORIZED SANITARY DESIGN The Actaris mass flowmeter is also available in a sanitary design. The sanitary flow sensor carries the 3A Authorization, with Tri-Clamp end connections and cleanin-place (CIP) capability. Each flow tube can be accessed individually for easy, thorough cleaning. OPTIONS The Actaris mass flowmeter may be specified to include various options: Bulk Terminal and Truck electronic registers A smart printer interface and a variety of ticket printers Vapor/air eliminators, strainers and differential control valves MOBILE CUSTODY TRANSFER The Actaris mass flowmeter can be resiliently mounted to truck frames or skids for noise-free, precise mobile custody transfer of fuels or high-cost fluids such as paint. PRINCIPLES OF OPERATION The Actaris mass flowmeter precisely determines mass flow by measuring the effects of Coriolis forces on a pair of omega-shaped tubes, which are electromagnetically vibrated. As fluid proceeds through the two parallel omega-shaped tubes, it experiences an acceleration transverse to the direction of flow, and Coriolis forces result. The Coriolis forces cause the displacement of the vibrating tubes to twist. Sensors detect this twist and transmit electrical signals reflecting the relative phase shift that is proportional to mass flow. Since tube vibration frequency varies with fluid density, frequency measurements are used to determine the fluid density and/or the percent solids. In addition, an RTD is used to detect temperature of the tube wall. Volume measurement is determined by mass/density. The unique omega-shaped tube design offers several key advantages. The tubes are very sensitive to the Coriolis forces at low fluid velocities. This translates into a very low pressure drop and outstanding accuracy (±0.15%, ±zero stability). Since there are two tubes in parallel, the flowmeter is virtually unaffected by extraneous vibrations. In addition, the omega-shaped design distributes the stress of movement in a torsional manner to eliminate bending stress points. BULK LOADING The Actaris mass flowmeter controls loading of transportation vehicles for maximum volume utilization year-round. The two-stage shut-off guards agianst spillage at high fill rates. These performance advantages combine to make the Actaris mass flowmeter the market leader for low fluid velocities, highly viscous fluids and abrasive liquids.

Mass Flow for Custody Transfer page 4 BULK OFF-LOADING The Actaris mass flowmeter can control off-loading and inventory management of costly liquids with outstanding accuracy year-round. CONTAINER FILLING Containers can be filled precisely with single or multiple fluids. SINGLE LIQUID/SINGLE TANK Delivery of a single costly fluid, such as a catalyst, can be metered with custody-transfer precision. MULTI-LIQUID/MULTI-BATCH Delivery of multiple costly or critical quantities for multiple formulations can be managed by a single mass flowmeter.

ACTARIS METER PERFORMANCE MODEL PROPERTY m025 1 m050 1,2 m100 1,2 m200 1,2 m300 1,2 m400 1,2 Operating ranges Flow rate, N/A 6.8 1.36 25 500 72.5 1450 408 4082 510 5103 kg/min (lb/min) (15 150) (30 300) (110 1100) (320 3200) (900 9000) (1000 10000) Density 0.3 to 1.42 range, g/cc Temperature 6 45 to 205 (-50 to 400) range, C ( F) Max. operating 250 250 83 68 103 103 pressure, bar (psi) 3 (3600) (3600) (1200) (1000) (1500) (1500) Accuracies/Repeatability Mass accuracy±0.15% of rate ± zero stability 4 Mass zero stability, ±0.0064 ±0.0168 ±0.0612 ±0.1901 ±.4536 ±0.9072 kg/min (lb/min) (±0.014) (±0.037) (±0.135) (±0.419) (±1.0) (±2.0) Mass repeatability, ±0.10 ±0.10 ±0.10 ±0.05 ±0.05 ±0.05 % of rate Density ±0.002 ±0.002 ±0.001 ±0.001 ±0.001 ±0.0008 accuracy, g/cc Density ±0.0005 ±0.0005 ±0.0005 ±0.0005 ±0.0002 ±0.0002 repeatability, g/cc Temperature ±0.56 (±1) accuracy, C ( F) Turndown ratio U.S. Applications: (10:1) Canada Applications:(20:1) except M300 and M400 which are (10:1) Physical Tube shape Omega Wetted materials 316L SST (HASTELLOY C-22 optional except m300) Nominal tube 6.4 (1/4) 12.7 (1/2) 25.4 (1.0) 51.0 (2.0) 75.0 (3.0) 101.6 (4.0) bore, mm (in.) Housing 304L SST Enclosure class Transducer is intrinsically safe when connected to an approved mass flow computer FM and CSA Class 1, Division 1, Groups C & D 3A-authorized Yes Yes Yes Yes No No version Connection type VCO: 3/8 VCO: 1 (5) (5) female female ANSI: 1/2 ; ANSI: 1/2, ANSI: 1, ANSI: 2, ANSI: 3, ANSI: 4, 150#, 300# 3/4, 1 ; 1-1/2, 2 ; 3, 4 ; 4, 6 6, 8 ; 600# RF 150#, 300# 150#, 300# 150#, 300#, 150#, 300# 150#, 300#, 600# RF 600# RF 600# RF 600#, 900# RF 600#, 900# RF 3A-Authorized: 3A-Authorized: 3A-Authorized: 3-Authorized: Tri-Clamp Tri-Clamp Tri-Clamp Tri-Clamp Industrial Industrial Industrial Industrial Tri-Clamp Tri-Clamp Tri-Clamp Tri-Clamp DIN: DN15; DIN: DN15, DIN: DN25, DIN: DN50, DIN: DN80 DIN: DN100, PN40, PN100 DN25; PN40, DN50; PN40, DN80, DN100; DN100, DN150; DN150, DN200; PN100 PN100 PN40, PN100 PN40, PN100 PN40, PN100 Mass Flow for Custody Transfer page 5 1 Meter size approved by N.C.W.M. (Approval No: 02-049). Approved flow rates in lbs/min. 2 Meter size approved by Measurement Canada (Approval No. AV-2292T). Approved flow rates in kg/min. 3 Limited by flange rating. 4 All calibration equipment traceable to N.C.W.M. 5 Special 2 flange connections to MT accessories available 6 Ambient temperature limits for FM & CSA approved models is 20 to 40 C ( 4 to 104 F).

DATAMATE OPERATING SPECIFICATIONS Housing 2 Temperature limitations Housing LCD Display Power supply Max. length of signal cable between flowmeter transducer and DATAMATE Safety approvals Operator interface Configuration (via keypad or RS-422) Function commands Local display Flow range Data retention Fault diagnostics Fiberglass IP 66, NEMA 4X 40 to 65 C ( 40 to 150 F) 20 to 65 C ( 4 to 150 F) 110 or 240 VAC, 50/60 Hz 20 40 VA depending on number of analog outputs, batching relays, etc. 150 m (500 ) 8-core Belden 89892 shielded twisted pair FM: Class 1, Division 2, Groups A, B, C & D CSA: Class 1, Division 2, Groups C & D Front panel keypad RS-422 serial communications Display format, engineering units, system constants, scaling factors, output ranges, alarm set points, serial communication parameters, batch presets Display, interrogate, run, program1, zero1, calibrate1, reset totals, clear alarms, initiate measurement 2-line, 20-character alphanumeric, variable contrast LCD: displays mass and volume flow rate and totals, density, temperature, percent solids and solids flow rate To complement the mass flowmeter By battery-backed RAM for 10 years in absence of power Four user-configured, open collector, 50 VDC, 100 ma; programmable for all variables ("Local display," above), plus batch total and diagnositcs Serial communications RS-422 adjustable baud rate: 1200, 2400, 4800, 9600 Performance Specifications Mass Accuracy: ±0.15% of rate ± zero stability Mass Repeatability: ±0.10% of rate (M400: ±0.05%) Density Accuracy: per transducer specifications Temperature Accuracy: ±0.56 C (±1 F) Optional outputs Up to four user-selected outputs 4 20 ma: Isolated, 50 to 800 ohms load Quadrature Pulse: Scaled square wave, 0.25 to 10,000 Hz Mass flow rate g, kg, oz, lb in time units of seconds, minutes or hours Mass flow total g, kg, oz, lb Density g/cc Temperature C, F Percent solids content % Volume flow rate Litre, U.S. gal, Imp. gal, bbl, in time units of seconds, minutes or hours Standard volume flow Litre, U.S. gal, Imp. gal, bbl, in time units of seconds, minutes or hours Two-stage batch control Standard: Dual SPST rated 10 A at 40 VDC resistive; 7 A at 240 VAC inductive FM I.S.: Dual SPST rated 200 ma at 24 VDC resistive; 13.86 ma at 120 VAC resistive NOT APPROVED FOR INDUCTIVELOADS CSA I.S.: Dual SPST rated 200 ma at 24 VDC resistive; 12.6 ma at 120 VAC resistive NOT APPROVED FOR INDUCTIVE LOADS Start/Stop: Independent momentary contract Manufacturer Actaris U.S. Liquid Measurement, Inc. Instrument model number DM2100 XXXXX 1 Parameters sealed by W&M 2 Ambient temperature limits for safety approved models are as shown below: FM, CSA Division 2: 20 to 65C ( 4 to 149 F) m is a registered trademark of Actaris. 2004 Actaris U.S. Liquid Measurement, Inc. 500 12/04 Specifications subject to change wihout prior notification. INDUSTRIAL DYNAMICS CO 1-800-940-0453