20th TECHNOLOGY REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. API 624 Valve Emissions STANDARD Update

Similar documents
For the highest operational safety around the clock

Cold-acclimatised pipelines

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

Proline Promass 200 Two-wire Coriolis measurement for the chemical industry

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

InstrumentationTools.com

Improving distillation tower operation

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

NEW VERSAFLOW CORIOLIS

Vortex Meters for Liquids, Gas, and Steam

An Overview of a Market Research Study on the Worldwide Coriolis Flowmeter Market

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Truck-mounted Mass Flow Metering for LPG Delivery

Measurement & Analytics Wet gas monitoring

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Flowmeter Shootout Part II: Traditional Technologies

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

ISS0065 Control Instrumentation Lecture 12

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Flow metering in gases Introduction to COMBIMASS family

Field Instrumentation Training Strategy

Gas Measurement Fundamentals Certification. Curriculum

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Radar, Ultrasonic and RF Level Transmitters

Vehicle- or rack-mounted liquefied gas meters, pump supplied

The Discussion of this exercise covers the following points:

Oil and Gas Custody Transfer

Yokogawa Systems and PCI Training

Products Solutions Services. Gas Flow Measurement

Variable Area Flow Meters

Wet Gas Flowmetering Guideline

LUGB Vortex Flowmeter

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

ELECTRIC ACTUATORS for continuous underwater use

SINGLE VALVE WITH LOW-FLOW BYPASS

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

THERMAL MASS FLOW MEASUREMENT FOR GASES

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Vehicle-mounted meters, pump supplied

Pro-V Multivariable Flowmeter

Calibrating and Monitoring MUSMs in Natural Gas Service

Electro-Magnetic Flowmeters Electromagnetic Sensor

SV60 Safety valves. for use with steam, gas and liquids

Level MEASUREMENT 1/2016

Gerald D. Anderson. Education Technical Specialist

Operational Settings:

analytical bulk flow distance FLOW level pressure temperature industrial communication

Orifice Plate Flow Meter

ERZ 2000-NG Flow Computer

H&D Fitzgerald Pressure Pyknometry System Mark 5

EVT * -Pro Electronic Valve Tester

CONTROL and INSTRUMENTATION

Vol. IX, No. 8

RCD - Ultra-Rugged Differential Pressure Flowmeter

Diagnostics in the instrumentation More than just equipment monitoring

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

Online data sheet FLOWSIC30 GAS FLOW METERS

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Coriolis Mass Flow Meter

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

OIL AND GAS INDUSTRY

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

Drilling Efficiency Utilizing Coriolis Flow Technology

Mass Flow Controllers

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

SITRANS F C MASSFLO. MASS flowmeters Sensor type MASS MC1 DN 50 - DN 100. Manual, supplement *083R9505* Order no.: FDK:521H1145

Micro Motion 7812 Fiscal Gas Density Meter

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Thermal Mass Flowmeters. 5 Mass Flowmeters

Installation, operating and maintenance Instructions for Seemag bypass level indicator

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Listening to the flow

Metering Code Gas TSO, measurement by connected party Effective from to the present

2007 Gas-Lift Workshop

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM

T EK-COR 1100A Coriolis Mass Flowmeter

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

BACK PRESSURE / SUSTAINING

Transcription:

API 624 Valve Emissions STANDARD Update Considering K-FACTOR ADJUSTMENTS How to CALCULATE Orifice-Plate FLOW RATE 20th 19 9 5-2 015 SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT SPECIAL SECTION PG 23 PUMPS, BEARINGS AND SEALS TECHNOLOGY REPORT JANUARY 2015 Vol. XXI, No. 1 www.flowcontrolnetwork.com

SYSTEMS DESIGN Flow Measurement The Two-Wire ADVANTAGE New wiring options enable modern instruments to drive cost savings in existing plant systems By Steve Milford COURTESY ENDRESS+HAUSER weigh such costs against projected market conditions for the products that the plant is intended to manufacture. In today s volatile global marketplace, return on investment calculations for plant upgrade or new plant construction projects may go through several iterations before the trigger is finally pulled, or indeed not pulled. This article describes advances in two-wire instrumentation, specifically in relation to flowmeters, that have taken place in the past few years, and the significant cost benefits that this new technology can realize for plant builders and operators in terms of capital investment and cost of ownership. The Significance of TwoWire Loop Power Advances in two-wire instrumentation have enabled modern technology to be employed to the advantage of older plant and process systems. S ome chemical manufacturing plants are competing for survival, not only externally against other global companies, but also internally among the global facilities of their own company. Other industry sectors face similar challenges. Process improvements to increase yield or cut manufacturing costs typically require enhanced process control, but the installed base of measurement instrumentation in a process plant may simply be unable to facilitate improvements because of age, inadequate performance, or unreliability. Maintenance cost and unscheduled process downjanuary 2015 time for an aging process plant can be very damaging to the balance sheet. Upgrading to new, more accurate, and more reliable instrumentation can be prohibitively expensive. New plant construction must also maintain a focus on optimizing costs for the process control infrastructure. The budget approval decision for new plant construction must A survey involving 204 participants in the chemical industry across Germany, Switzerland, the UK, Canada, and the United States (Manfred Koenig, Ph.D., K.I.M. Ludwigshafen, Germany, 2006) revealed an 87 percent preference for two-wire instrumentation versus fourwire in process applications, and 89 percent for utilities. This overwhelming preference may stem from the fact that older process plants were built with two-wire, twisted-pair cable networks, connecting all process units and measuring instruments together in an overall plant control scheme. However, these existing cables are relatively unsophisticated and incapable of supporting anything but low-energy instrumentation that is inflow Control Magazine

COURTESY ENDRESS+HAUSER Figure 1. A two-wire ultrasonic flowmeter, released in 2006, operated on a single, 4-20 ma two-wire loop. sensitive to interference from other electrical sources that might be sharing the same cable conduit. Further, the low energy levels supported by these two-wire loops are more easily rendered safe in terms of explosive risk in hazardous areas containing flammable materials. Many older process plants are also likely to have a significant installed base of flowmeters employing pre- war (pre-1945) technology, such as positive displacement (PD), turbine, variable area (VA or Rotameter), and differential pressure (dp). Market data firm Flow Research Inc. (www.flowresearch.com) indicates collectively a future compound negative annual growth rate approaching minus 3 percent to 5 percent for PD, turbine and VA flowmeter types, while dp is expected to keep pace with market growth (World Market for Flowmeters, 2010). The Need to Replace Older Technologies Until the 21st century, two-wire loops were only able to support these relatively unsophisticated instruments, which convert their measurement by various means into a 4-20mA output or pulse signal to the control system. The more advanced post-war flowmeter technologies, such as Coriolis, ultrasonic or electromagnetic flowmeters have, until just eight years ago, required a dedicated power supply for their function, in addition to the output loop, and thus a four-wire infrastructure was required as a minimum. Therefore, upgrading older two-wire meter devices to more modern four-wire technology could require significant expenditure in terms of the installation of separate power cables and supply modules. There was a major breakthrough in 2006 when a true two-wire, loop-powered inline liquid ultrasonic flowmeter was introduced (Figure 1). The nature of this breakthrough was innovation in device power management. This was the missing piece up to that point, because to be a true loop-powered device, the meter had to directly provide a full Modern flow technologies provide instrument engineers with vital self-monitoring information. The format of such information is easier to understand and act upon when presented in accordance with harmonized international guidelines for online plant asset management; e.g., NAMUR Standard 107. 16 ma span using less than 3.6 ma of remaining loop current and less than 1 Watt of electrical energy. The flowmeter operated on a single, 4-20 ma HART two-wire loop, was remotely powered by a DC supply, was certified Class 1 Division 1, and could be deployed as Intrinsically Safe through the use of an approved safety barrier. A true two-wire, loop-powered Coriolis flowmeter followed in 2011 (Figure 2), employing a new and more advanced common electronics platform. A two-wire loop-powered inline ultrasonic flowmeter for low-pressure gas was introduced in 2012, and a second two-wire loop-powered Coriolis meter followed in 2013, offering improved measurement performance and an additional high-performance meter tube material. Electromagnetic and vortex flowmeters had already been available for some years in two-wire loop-powered form, but improved performance resulted as these designs were incorporated into their new, common electronics platform in 2013. So all the modern flow measurement technologies that is to say those introduced post-war have become available as two-wire, looppowered devices with one exception, namely, thermal mass (thermal dispersion) meters. Unfortunately, the power requirements for this technology exceed what is currently deemed possible with two-wire, loop-power management. Payback for Technology Upgrade Consider a 1 process line containing a liquid process ingredient costing $1/lb at a mass flowrate of 150 lb/minute. We have $150/minute flowing in the line, translating to $9,000/hour, and $72,000 per eight-hour shift. That calculates further to $360,000 per five-day working week, and for a working year of 40 weeks, for example, that is $14.4 million. Assume the existing device is a turbine flowmeter. Now, imagine a two-wire, loop-powered Coriolis mass flowmeter is installed in place of the existing meter. The line would need to be drained, and probably one process flange replaced allowing the Coriolis to fit mechanically in place of the turbine. However, the two-wire loop already www.flowcontrolnetwork.com January 2015

SYSTEMS DESIGN Flow Measurement COURTESY ENDRESS+HAUSER Figure 2. Two-wire Coriolis flowmeters became available in 2011. used for carrying the existing meter s flow signal to the control room can be used unaltered for the complete electrical installation aspects of the Coriolis flowmeter. The upside of the change is significant and clear cut. Assuming the existing meter measurement uncertainty was 0.2 percent of reading, then measurement uncertainty improves through use of Coriolis to 0.1 percent of reading, giving a 0.1/100 x $14,400,000 improvement in control of the ingredient annually, or $14,400. A twowire Coriolis mass flowmeter with 0.1 percent mass flow accuracy would be paid for in approximately 6-8 months. In practice, the improvement in measurement uncertainty would be greater, as the operator would gain temperature and density information from the Coriolis and the measurement would be devoid of any fluid property dependence. Viscosity change, for example, can have a major impact on turbine meter performance. Mechanical wear and tear that turbine meters eventually experience, which causes them to under-register flow, is precluded by modern devices like Coriolis. Furthermore, if the process ingredient was being blended with another, then additional process improvements could be realized through in-line blending control using Coriolis technology for final density as the control point. It is possible to have dual 4-20 ma outputs from two-wire loop-powered meters, but as the main 4-20 ma output representing the primary variable is also HART, then an external HART Loop Converter or HART I/O card in the control system can provide secondary, tertiary and quaternary variables as 4-20 ma signals. A Coriolis meter is truly a multi-variable device. Certain two-wire devices are also available with Profibus or Foundation Fieldbus communication. Cutting Wiring Costs In 2003, WIB/EXERA (International Instrument Users Associations) Report T 2732 X 03 was published, and it provided an average survey of prices quoted in projects at that time for the provision of power supplies for fourwire instruments. The price ranged from 1,200 to 1,800 per instrument, depending upon design and plant characteristics, for an average cost of 1,500 (about $2,000). It would be reasonable to assume an inflationary In today s volatile global marketplace, return on investment calculations for plant upgrade or new plant construction projects may go through several iterations before the trigger is finally pulled, or indeed not pulled. factor of 2 percent per annum, giving an approximate current-day figure of $2,500. From another source within the chemical industry, an estimation of $40/foot to $50/foot was given for installation of four-wire cabling. For a linear 50-foot cable run, with, for example, a 10-foot vertical at each end, this equates to $3,150. Actual costs and budget estimates have been given as high as $10,000. The Extent of the Opportunity The modern post-war flow measurement technologies have different power requirements, and consequently, they are not all available for the same size range in two-wire, loop-power form. For example, two-wire Coriolis flowmeters are limited to 2 diameter; electromagnetic and inline low-pressure gas ultrasonics are limited to 8 ; and vortex and inline liquid ultrasonic are limited to 12. Nevertheless, for the chemical industry in particular, perhaps two-thirds of the process pipes in a plant will be no larger than 2, and even when the host process pipe is larger, a correctly sized flowmeter can still be less than 2. There is considerable scope for twowire loop-power to deliver value for flow measurement applications with total safety. The virtues of Coriolis technology have been covered, but what about other two-wire technologies? An electromagnetic flowmeter in two-wire form can be used on water, wastewater, or a light water-based slurry provided the fluid has around a 20 µseimens/centimetre (µs/ cm) electrical conductivity. A magnetic flowmeter is full bore, unless flowrates dictate a reduced meter size in the interests of performance, and so there are no intrusions into the flow stream and no pressure loss. An accuracy of 0.5 percent of reading is normal from a two-wire magnetic meter, and a modest five diameters (5D) of straight inlet run is needed to avoid error from upstream flow disturbances. When the fluid exhibits insufficient conductivity, then the same performance and installation requirements can be met by an inline ultrasonic flowmeter provided the liquid is essentially clean and bubble-free. January 2015 Flow Control Magazine

COURTESY ENDRESS+HAUSER Figure 3. A modern instrument s display module can provide continuous plain-text selfdiagnostic and process-related information. For gas or steam applications, a vortex meter is the normal choice. Using a built-in temperature sensor, a two-wire, loop-powered vortex meter can calculate mass flow of saturated steam using internal steam tables. An external pressure input allows mass flow of steam to be accurately calculated even when saturated steam becomes superheated, as can occur downstream of a pressure regulating valve. With mass flow known, the vortex meter can calculate energy and heat flow. A new and exciting development is the ability of the vortex meter to indicate wet steam and calculate dryness fraction or steam quality. For safety and efficiency, saturated steam should be dry and free from condensate; that is to say, it should possess a high steam quality factor. However, the dry or wet state of saturated steam can sit on a knife-edge and shift to the opposing state due to the slightest change in process conditions. Rapid and reliable indication of this change of state is now available. Perhaps the most astonishing achievement in the power management FLOWSTREAM of two-wire, loop-power flowmeters is that of the ultrasonic biogas meter. It is now possible not only to measure the flow of wet, dirty, variable composition and low-pressure anaerobic digester gas, landfill gas, and coal bed methane gas with a two-wire, loop-powered ultrasonic flowmeter, but also the same device uses an inbuilt temperature sensor in combination with measured sound velocity to calculate methane content, calorific value, and energy flow. Technology to Take Us Forward Modern flow technologies provide instrument engineers with vital selfmonitoring information. The format of such information is easier to understand and act upon when presented in accordance with harmonized international guidelines for online plant asset management; e.g., NAMUR Standard 107. Continuous plain-text self-diagnostic and process-related information, with suggested remedies (Figure 3) make it possible for instrument engineers and operators to take action at the appropriate time immediately or during the next scheduled shutdown saving time and money by knowing the exact health of their measuring point and the probable actions required to rectify any abnormal conditions. Device verification, offering thirdparty validated traceability, can be performed on demand either locally or remotely from the control room without the expense of a man in the field. Calibration is then avoided or deferred without process interruption. Where a process plant has a large installed base of older mechanical technologies, the decision to embark upon a program of replacement for plant modernization cannot, of course, be taken easily. There are the stocks of spare parts to consider along with the plant instrument technicians who are trained on, and at ease with, the old devices. However, a process plant that retains the older technology going forward will be at risk and may find it increasingly difficult or even impossible to maintain a cost position that competes effectively in the global market. FC Steve Milford is a Flow Product Business Manager for Endress+Hauser Inc. in Greenwood, Ind. He has been involved in flow measurement since Steve Milford 1983 and has been actively involved with standards development for flow technology within the International Standards Organization (ISO) and the British Standards Institute. Mr. Milford can be reached at steve.milford@us.endress.com. Find related content @ flowcontrolnetwork.com Search on: www.us.endress.com Coriolis Flowmeter Magnetic Flowmeter Two-Wire Ultrasonic Flowmeter Vortex Flowmeter www.flowcontrolnetwork.com January 2015