Dual Solenoid Gas Valve Installation

Similar documents
BGA158 Series CE Approved Class B Shutoff Gas Valve

GM-7000 Series CE Approved Gas Control Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGC258 Series BASOTROL Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

G96 Series BASOTROL Dual Operator Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

GM-7000 Series CE Approved Gas Control Valve

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36H SERIES Combination Gas Valve

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G95 Series BASOTROL Single Operator Valve

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SPECIFICATIONS CAPACITY

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

SPECIFICATIONS ATTENTION

VR46.5V(A)/VR86.5V(A) SERIES

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

VR8305 Direct Ignition Combination Gas Control

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

ACCESSORY KIT INSTALLATION MANUAL

VR8200A Continuous Pilot Combination Gas Controls

VR8205S,T Direct Ignition Combination Gas Controls

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

SPECIFICATIONS ATTENTION

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

VK8515M(R) MODULATING GAS CONTROL APPLICATION DESCRIPTION SPECIFICATIONS INSTRUCTION SHEET. Electrical data

Installation Instructions

453 Series Steam Heated Vaporizing Regulator

VS8420 Millivolt Gas Valve

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

VK41../VK81.. GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM SPECIFICATIONS APPLICATION DESCRIPTION INSTRUCTION SHEET

Natural Gas to L.P. Gas Conversion Kit

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

IPG IGNITION GAS PILOTS BACK-LOADED GAS

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Installation Instructions

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

Your safety and the safety of others are very important.

INSTALLATION GUIDE Gas Rangetops

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Types 749B and R130 Changeover Manifolds

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

V43 Pressure Actuated Water Regulating Valve

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Installation Instructions For Natural Gas Conversion

Valve Proving System VDK 200 A S06*

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

installation instructions

Instruction Manual No. 742, 8/98

VR8104, VR8204, and VR8304 Intermittent Pilot Combination Gas Controls

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Commonwealth of Massachusetts Approved Product Approval code G

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Valve Proving System VDK 200 A S02

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

Transcription:

Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions on the appliance. Limit repairs, adjustments, and servicing to the operations listed in this bulletin or on the appliance. The system must meet all applicable local, national, and regional regulations. Improper installation may cause gas leaks, explosions, property damage, and injuries. To prevent leakage of upstream gas, shut off the gas supply at the main manual shutoff valve before installing or servicing the DUAL valve. Failure to shut off the gas supply can result in the release of gas during installation or servicing, which can lead to an explosion or fire, and may result in severe personal injury or death. Mounting To install the DUAL valve: 1. Ensure that the specified maximum ambient (surface) temperature is not exceeded (see the Technical Data section). 2. Ensure that the power supply voltage is compatible with the required control valve voltage. 3. Shut off the gas at the main manual shutoff valve. 4. When installing the valve on the manifold, ensure that the gas flows through the valve body in the direction indicated by the arrow on the valve body. If the valve is installed with the gas flow in the opposite direction of the arrow, leakage can occur. 5. Mount the valve to the pipework. The DUAL valve may be mounted on a horizontal manifold with the solenoid coils pointed up (vertical) or in any position not exceeding 90 from the vertical. The valve also may be mounted on a vertical manifold in any position around its axis (see Figure 1). Do not install the solenoid coil upside down. Install vertically wherever possible. 90 Maximum from Vertical Limited Horizontal and Vertical 90 Maximum from Vertical CAUTION: Risk of Equipment Damage. To prevent damage to the valve when mounting to pipework, do not use a wrench on any surface other than the casting flats provided at the inlet and outlet ends of the valve body. No Regulator Vertical mounting may be 360º around its axis with the gas flow either up or down, but always in the direction of the arrow. Figure 1: DUALValve Mounting Positions 1

6. Thread pipe (the amount shown in Table 1) for insertion into the control. Do not thread the pipe too far. Valve distortion or malfunction may result if the pipe is inserted too deeply. Table 1: NPT Pipe Thread Length Into Valve Pipe Size (NPT) Thread Pipe Amount (in.) Maximum Depth Pipe (in.) 1/2 3/4 1/2 3/4 13/16 3/4 7. For any threaded connections, threads of pipe and nipples must be smooth and free of tears and burrs. Steam clean all piping inside diameter to remove foreign substances such as cutting oil or thread chips before installing into the valve. Apply a moderate amount of good quality pipe compound (do not use Teflon tape) to pipe only, leaving two end threads bare (see Figure 2). On LP in use compound resistant to LP gas. CORRECT APPLY A MODERATE AMOUNT OF PIPE COMPOUND TO PIPE ONLY (LEAVE TWO END THREADS BARE), WRONG CAUTION: EXCESSIVE COMPOUND MAY BLOCK DISC OFF VALVE SEAT CAUSING LEAKS. Figure 2: Use a Moderate Amount of Pipe Compound 8. Ensure the gas flows through the valve body in the direction indicated by the arrow on the body. If the valve is installed with the gas flow in the opposite direction of the arrow, leakage can occur. Connect pipe to gas control inlet and outlet. Use a wrench on the square ends of the control. If a flange is used, place the wrench on the flange rather than on the controls. This process should be used for both the installation and removal of the valve in a gas system (see Figure 5). 9. If you desire to measure the outlet pressure, use the bottom cast pressure test fitting (see Figure 4) or use the Y99AX pressure test fitting (see Figure 3) and an approved pipe joint compound on the male threads and replace the marked pressure tap plug, which is optional on the inlet or outlet of the valve body. Screw the fitting into threaded port of the valve, which replaces the pressure tap plug. Figure 3: Y99AX-1 (1/8-27 NPT) Pressure Test Fitting Y99AX-2 (1/8-28 BSPT) Pressure Test Fitting 10. Check for leakage before making any valve adjustments. a. Shut off the gas at the main manual shutoff valve and open the pressure connection between the manual shutoff valve and the DUAL valve. b. Connect air tubing with a maximum pressure of 1-1/2 times the valve s maximum operating pressure (as indicated on the valve) to the opened pressure connection. c. Paint all valve body connections with a rich soap and water solution. If bubbles occur, this is an indication of a leak. To stop a leak, tighten joints and connections. Replace the part if the leak cannot be stopped. If bubbles do not occur, remove the air tubing and close the pressure connection. 11. Make wiring connections. Refer to the Wiring section for specific wiring instructions. 12. Check for leakage at the bleed hole. Paint the bleed hole with a rich soap and water solution (or use acceptable gas leak detection equipment). If bubbles occur, this is an indication of a gas leak. To stop a leak, tighten the needle screw. Replace the valve if the leak cannot be stopped. 13. Observe at least three complete operating cycles to ensure that all components are functioning correctly before leaving the installation. Outlet Pressure Tap Connection Figure 4: Underside of Valve 2

APPLY WRENCH TO THE FLATS FROM THE TOP OR BOTTOM OF THE GAS CONTROL VALVE APPLY WRENCH TO FLATS ONLY Figure 5: Proper Use of Wrench on Gas Control 3

Wiring WARNING: Risk of Electrical Shock. Disconnect the power supply before making electrical connections to avoid electrical shock or equipment damage. Ensure that the operating voltage is identical to the information on the product identification label. The DUAL valve is supplied with 3-tab or 2-tab electrical connections. The solenoid coils are male tabs and electrical connections should be made using 6.35 x 0.8 mm (1/4 in.) female, fully insulated push-on terminals. The earth ground is clearly labeled. The electrical wiring to a twin solenoid valve from an electronic intermittent proven pilot ignition system is comprised of two lines; a common and an independent earth ground. Wiring can be done using a single 4-wire cable. The wiring connections for a 4-wire cable are shown in Figure 6. Route the electrical cable for the valve solenoid from the burner sequence control to the valve and make wiring connections in accordance with Figure 6. Note: Electrical connections can also be made using electrical plugs (DIN 43650 Form B [ISO 4400]). Available from a FLYNN Gas Products distributor. Note: All wiring must be in accordance with national and local electrical codes and regulations. Setup and Adjustments Checkout Follow this or an equivalent checkout procedure after installation. Before leaving the installation, verify that the gas valve functions properly and that the system has no gas leaks. Gas leaks can lead to an explosion or fire, and may result in severe personal injury or death. The minimum flow rate of the valve must not be adjusted below the minimum safe working rate of the appliance. This may cause gas leaks, which can lead to an explosion or fire and may result in severe personal injury or death. Make sure all components are functioning properly by performing the following test: 1. Test all joints and connections for leaks with a soap solution. 2. Close the main upstream shutoff valve and wait at least 5 minutes for unburned gas to escape from the appliance, and then reopen the shutoff valve. 3. Turn on the main electrical power switch and close the thermostat contacts. The appliance should operate in accordance with the manufacturer s specified sequence of operation. 4. Turn the thermostat to a low dial setting to open the contacts. All burner flames should be extinguished. Repeat Steps 3 and 4 at least three times. 5. Return the thermostat to a normal setting before leaving the installation. Repairs and Replacement Table 2: Replacement Solenoid Coil Part Number Description RSDA16A-12 RSDA16A-25 RSDA16A-25V RSDA16A-120 RSDA16A-240 12 VDC; 2-tab 15 VA Coil 25 VAC; 50/60 Hz; 3-tab 15 VA Coil 25 VDC; 3-tab 17 VA Coil 120 VAC; 50/60 Hz; 3-tab 15 VA Coil 240 VAC; 50/60 Hz; 3-tab 15 VA Coil Field repairs other than solenoid coil replacement must not be made to the DUAL valve. Any attempt to repair this assembly voids the manufacturer s warranty. For a replacement valve, contact the original equipment manufacturer or the nearest FLYNN Gas Products distributor. IMPORTANT: All adjustments must be made in conjunction with the gas appliance and in accordance with the appliance manufacturer s instructions. Only authorized personnel should make adjustments. 4

Earth Ground Line 2 Neutral Line 1 L2 N2 N1 L1 Coil 2 Main Valve Coil 1 Pilot Valve Twin Solenoid Wiring Using 4-Wire Cable Non-Polarity Sensitive Line and Neutral Connections Ground Tab 25V, 120V and 240V Only Non-Polarity Sensitive Line and Neutral Connections Ground Tab 25V, 120V and 240V Only To Pilot Solenoid To Main Solenoid L N L N Figure 6: 3-Tab Electrical Connections 5

Technical Specifications Product DUAL CE Approved Class A Gas Valve Types of Gas 2nd (Natural Gas), and 3rd (LP Gas) Family Gases Permissible Ambient (Surface) -29 to 79 C (-20 to 175 F) Temperature Electrical Ratings 12 VDC, 1.0A 25 VDC, 0.675A 25 VAC, 50/60 Hz, 0.595A 120 VAC, 50/60 Hz, 0.13A 240 VAC, 50/60 Hz, 0.063A Rated Inlet Pressure Maximum Working Pressure (CE) Reverse Pressure Ratings Body Connections North America: Europe: Australia: 138 mbar 2 psi 138 mbar 13.8 kpa 150 mbar (15 kpa [60 in. W.C.]) Class A (EN 161); Class 1 (AS 4629) 3/8 or 1/2 NPT, 3/8 or 1/2 BSPP (Thread ISO 7-Rp), 3/8 or 1/2 BSPT (Thread ISO 7-Rc) with Flange Connection Holes (M4 x 0.7 mm pitch x 6 mm deep) Valve Torsion Group Group 2 (EN 161) Pressure Connection 1/8 BSPP (Thread ISO 7-Rp), 1/8 BSPT (Thread ISO 7-Rc), 1/8 NPT Left-hand and/or Right-hand, or M5 x 0.8 Thread Bottom Pilot Connections 1/8 BSPP (Thread ISO 7-Rp), 1/8 BSPT (Thread ISO 7-Rc), 1/8 NPT Left-hand and/or Right-hand or 1/4 in. cc Fitting Bottom Dirt Strainer 0.9 mm (0.036 in.) Mesh (CE only or upon request) Operating Time 100% Continuous Rating Valve Timings Closing Time Opening Time Dead Time <1 Second <1 Second <1 Second Power Ratings 15 VA per Coil (except 25 VDC, 17 VA) Electrical Connections Coil Insulation Class Packaging Bulk Pack Quantity Bulk Pack Weight 3-Tab Solenoid Coil 2-Tab Solenoid Coil Class F 2 x 6.35 mm (1/4 in) + 6.35 mm (1/4 in) Earth Ground 2 x 6.35 mm (1/4 in) Bulk pack supplied to original equipment manufacturer (individual pack optional). 30 per carton 35 kg (77 lb) per carton 6

Technical Specifications (continued) Agency Listings CSA (AGA/CGA) Certificate Number 229521-1656041 EC Type Examination Certificate Number EC-86/10/062 UL File Number MH5939 Australian Gas Association Certificate Number 7934 Specification Standards EN 161 Standards Complying with EMC Directive Standards Complying with Low Voltage Directive Australian Standard AS 4629 ANSI Standard Z21.21 Canadian Standard CSA 6.5 UL Standard 429 Performance specifications are nominal and conform to acceptable industry standards. All agency certification of FLYNN products is performed under dry and controlled indoor environmental conditions. Use of FLYNN pr oducts beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of FLYNN products. Consult FLYNN BURNER for questionable applications. FLYNN BURNER shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. 7