COMPRESSION SET Description: The seal exhibits a flat-sided cross-section, the flat sides correspoding to the mating seal surfaces.

Similar documents
MIL-STD-883H METHOD EXTERNAL VISUAL

SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION.

THERBAN /HNBR for the Energy Sector

Dichtomatik O-Ring Handbook

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Flange Insulation. Gasket Basics. Why Gaskets Are Used:

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

Engineering. Contents. Parker Fluid Power Seals for All Application Technologies. Sealing Theory

DuPont Kalrez. Oil and Gas Product Selector Guide. Technical Information April 2017

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

Technical information for O-rings

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141

S-200W LP WHITE THERMAL CURE LEGEND INK

Product Name: Concrete Anchor Strap

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

Translation of the original Operating Instructions for HKS rubber compensators

Engineering Data Sheet

Thermal Profiling the Reflow Process

Roller Chain and Sprocket Troubleshooting Guide

Engineering. Contents. Parker Fluid Power Seals for All Application Technologies. Sealing Theory. Static vs. Dynamic Sealing

ACCU-PULSE Installation and Operation Instructions

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Product Name: Non-Shock Lanyard

The Experts in Vacuum Solutions

Manufactured and Supplied By: PyroTech, Inc. Business Telephone: A Republic Drive Date Prepared: July 1, 2000

Issue Date no data available Revision date 04-Dec-2012 Version 1. Section 1: PRODUCT AND COMPANY IDENTIFICATION

Introduction to Perfluoroelastomers. White Paper

Lecture 18. Aerostatic Bearings

Issue Date no data available Revision date 04-Dec-2012 Version 1. Section 1: PRODUCT AND COMPANY IDENTIFICATION

Product Name: Beamer Instruction Manual. Part #: 00110

Product Name: Internal Shock Lanyard

Product Name: 2-Way Standing Seam Roof Clamp

Excellent sealing in applications that require separation of two different fluids. Low breakout friction and elimination of stick-slip action

Product Name: Bull Ring Anchor

Product Name: Angel Anchor

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

OPERATING AND MAINTENANCE MANUAL

Phase B: Parameter Level Design

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

SSR SWIVEL SEAL TECHNICAL DETAILS. Part Number Structure. ID Sealing F E A T U R E S SSR M R N 711. Good anti-extrusion resistance

MS Back-up, Spiral

Design Enhancements on Dry Gas Seals for Screw Compressor Applications

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Product Name: Beamer Trolley Anchor

Product Name: Universal Guardrail Post

Mild steel. Stainless steel. HPR130XD Auto Gas Revision 2. Nozzle retaining cap. tube. Shield cap 30 A 50 A 80 A 130 A

Product Name: Edge Series Web SRL

TABLE 4 TABLE 5. Design Recommendations. for Conductive Elastomers. Fillers. Profiles

LECTURE 9 1. CARE AND PRECAUTION OF X-RAY TUBE 2. X-RAY TUBE AGING KAAB

O-RINGS. ! Description and advantages

THERMOPLASTIC HOSE INSTALLATION FACTORS

Session 4B 11:00 11:30 AM. BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS

Assembly and Installation Procedures

Gasket material and seal integrity in Thermo Scientific 2D Barcoded Storage Tubes

FLANGED TWO-PIECE BALL VALVES

MU102: Mechanical Seals Applications for Rotating Machinery

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

FLANGED TWO-PIECE BALL VALVES

User Instructions 1790 Rail Anchor

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Kalrez seals for proven reliability in aggressive wafer processing environments

: Nylon Nylox Brushes

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Product Name: Hold Me Rope Anchor

3M DICHROIC Glass Finishes

Eliminating Gross Leakers by Seal Processing for Lowest Leak Rates per MIL-STD-883 TM 1014 Seal

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Ropes Care and Maintenance Revised

Inflatable Packers for Grouting 11/10/00

USER S INSTRUCTION MANUAL FOR THE INSTALLATION, OPERATION & MAINTENANCE OF THE GUARDIAN TEMPORARY HORIZONTAL LIFELINE SYSTEM

VALVES & MEASUREMENT

SAES Packaging service. making innovation happen, together

Product Name: Standing Seam Roof Clamp

USER INSTRUCTIONS LARGE HOOK & STRAP ANCHORAGE CONNECTOR ! WARNING

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Gilson Aqua-Check Moisture Tester MA-26X

: Ceramic Aluminum Oxide Nylox Brush

MIL-STD-810 F/G Standards

The Principles of Vacuum Technology

Easy Nest Kits. Installation Suggestions

SB AXIAL FLOW VALVES

INSTALLATION, OPERATION & MAINTENANCE MANUAL

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

"PERSONAL PROTECTIVE EQUIPMENT"

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Roof Anchor INSTRUCTION MANUAL

SOLAR ENERGY. solutions. adhesives, sealants, and Potting encapsulants For solar energy applications

User Instructions 1789 Parapet Wall Anchor

How To Use Getters and Getter Pumps

Component CAS Number ACGIN TLV Weight % = 70

Crusher Bearings: Knowing the Basics Leads to Better Care

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

shutoff valves 900 Series psig Manual Shutoff Valves

STRIP EDGE SHAPE CONTROL

FLUSHMATE FLUSHOMETER - TANK SYSTEM

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

Transcription:

Bentwood, NH (603) 678-9610 ABRASION Description: The seal or parts of the seal exhibit a flat surface parallel to the direction or motion. Loose particles and scrapes may be found on the seal surface. Contributing Factors: Rough sealing surfaces. Excessive temperature. Process environment containing abrasive particles. Dynamic motion. Poor elastomer surface finish. Suggested Solutions: Use recommended gland surface finishes. Consider internally lubed elastomers. Eliminate abrasive components. COMPRESSION SET Description: The seal exhibits a flat-sided cross-section, the flat sides correspoding to the mating seal surfaces. Contributing Factors: Excessive compression. Excessive temperature. Incompletely cured elastomer. Elastomer with high compression set. Excessive volume swell in chemical. Suggested Solutions: Low compression set elastomer. Proper gland design for the specific elastomer. Confirm material compatibility. CHEMICAL DEGRADATION Description: The seal may exhibit many signs of degradation including blisters, cracks, voids or discoloration. In some cases, the degradation is observable only by measurement of physical properties. Contributing Factors: Contributing Factors: Incompatibility with the chemical and/or thermal environment. Suggested Solutions: Selection of more chemically resistant elastomer.

CONTAMINATION Description: The seal exhibits foreign material on the surfacewithin the cross section. Contributing Factors: Process environment deposition. Reactions or degradation of the elastomer. Suggested Solutions: Specify contamination level including manufacturing and packaging of the seals. EXPLOSIVE DECOMPRESSION Description: The seal exhibits blisters, pits or pocks on its surface. Absorption of gas at high pressure and the subsequent rapid decrease in pressure. The absorbed gas blisters and ruptures the elastomer surface as the pressure is rapidly removed. Contributing Factors: Rapid pressure changes. Low-modulus/hardness elastomer. Suggested Solutions: Highermodulus/hardness elastomer. Slower decompression (release of pressure). EXTRUSION Description: The seal develops ragged edges (generally on the low-pressure side) which appear tattered. Contributing Factors: Excessive clearances. Excessive pressure. Lowmodulus/hardness elastomer. Excessive gland fill. Irregular clearance gaps. Sharp gland edges. Improper sizing. Suggested Solutions: Decrease clearances. Higher-modulus/hard-ness elastomer. Proper gland design. Use of polymer backup rings.

INSTALLATION DAMAGE Description: The seal or parts of the seal may exhibit small cuts, nicks or gashes. Contributing Factors: Sharp edges on glands or components. Improper sizing of elastomer. Low-modulus/hardness elastomer. Elastomer surface contamination. Suggested Solutions: Remove all sharp edges. Proper gland design. Proper elastomer sizing. Higher-modulus/hardness elastomer. OUTGASSING / EXTRACTION Description: This failure is often very difficult to detect from examination of the seal. The seal may exhibit a decrease in cross-sectional size. Contributing Factors: Improper or improperly cured elastomer. High vacuum levels. Low hardness/plasticized elastomer. Suggested Solutions: Avoid plasticized elastomers. Ensure all seals are properly post-cured to minimize outgassing. OVERCOMPRESSION Description: The seal exhibits parallel flat surfaces (corresponding to the contact areas) and may develop circumferential splits within the flattened surfaces. Contributing Factors: Improper design failure to account for thermal or chemical volume changes, or excessive compression. Suggested Solutions: Gland design should take into account material responses to chemical and thermal environments.

PLASMA DEGRADATION Description: The seal often exhibits discoloration, as well as powdered residue on the surface and possible erosion of elastomer in the exposed areas. Contributing Factors: Chemical reactivity of the plasma. Ion bombardment (sputtering). Electron bombardment (heating). Improper gland design. Incompatible seal material. Suggested Solutions: Plasma-compatible elastomer and compound. Minimize exposed area. Examine gland design. SPIRAL FAILURE Description: The seal exhibits cuts or marks which spiral around its circumference. Contributing Factors: Difficult or tight installation (static). Slow reciprocating speed. Low-modulus/hardness elastomer. Irregular O-ring surface finish (including excessive parting line). Excessive gland width. Irregular or rough gland surface finish. Inadequate lubrication. Suggested Solutions: Correct installation procedures. Higher-modulus elastomer. Internally-lubed elastomers. Proper gland design. Gland surface finish of 8 16 microinch RMS. Possible use of polymer backup rings. THERMAL DEGRADATION Description: The seal may exhibit radial cracks located on the highest temperature surfaces. In addition, certain elastomers may exhibit signs of softening a shiny surface as a result of excessive temperatures. Contributing Factors: Elastomer thermal properties. Excessive temperature excursions or cycling. Suggested Solutions: Selection of an elastomer with improved thermal stability. Evaluation of the possibility of cooling sealing surfaces.