VBL Volume Booster. Instruction Manual Part Number: D103317X012, Rev. 1 Release: August 2013

Similar documents
VBL Volume Booster. Features. D103393X012 January 2013

Fisher 2625 and 2625NS Volume Boosters

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

BETTIS RPE Series Rack and Pinion Pneumatic Actuators. Safety Guide DOC.SG.BRPE.EN Rev. 1 November 2015

Safety Guide DOC.SG.EF.EN Rev. 0 March EL-O-Matic F-Series Rack and Pinion Pneumatic Actuators

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Shafer RV-Series Rotary Vane Valve Actuators

64 Series Pressure Reducing Regulators

Fisher DVI Desuperheater Venturi Inline

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

1805 Series Relief Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Masoneilan* 78 Model Air Filter Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type R622 Pressure Reducing Regulator

Fisher L2sj Low Emission Liquid Level Controller

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Masoneilan* Model 78-80S & 08-80S Transfer Valves

1805 Series Relief Valves

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Model 4000 Pressure Controller

Fisher DSA Steam-Atomized Desuperheater

MEGR-1627 Instruction Manual

1305 Series Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

PRO-50 Instrument Supply Regulator

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Design DSA Steam-Atomized Desuperheater

A Complete Solution For HIPPS

OPERATING AND MAINTENANCE MANUAL

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Masoneilan* Model 78-80H & 08-80H Transfer Valves

Fisher 4660 High-Low Pressure Pilot

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

MEGR-1912 Instruction Manual

Type EZH Relief or Backpressure Regulator

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

T208VR Series Tank Blanketing Vacuum Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Fisher 4660 High-Low Pressure Pilot

Fisher and Whisper Disk Diffusers

1301 Series High-Pressure Regulators

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Safety manual for Fisher GX Control Valve and Actuator

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

C1 Series Pneumatic Controllers and Transmitters

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Types 749B and R130 Changeover Manifolds

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Fisher C1 Pneumatic Controllers and Transmitters

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Fisher 4194 Differential Pressure Indicating Controllers

Float Operated Level Controllers

RB Series Regulating System

Temperature Controllers

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

English. Safety Instructions Form /2007 WARNING. All Products. How to Get Safe-Use Guides. Inspection and Maintenance Schedules

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

627 Series Pressure Reducing Regulators

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters

Type CT88 Backpressure Regulator

4194 Series Differential Pressure Indicating Controllers

Type 4660 High-Low Pressure Pilot

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Operation Manual Piston Sensed Gas Pressure Regulators

Model Series 62 Constant Differential Relay

The Ins and Outs of I/P Transducers

Fisher 8532 High-Performance Butterfly Valve

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

S300 Series. Valve Link. Features. Fisher Controls

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

Type 92S Pilot-Operated Steam Regulator

Y692VB Series Vacuum Breaker

1301 Series High-Pressure Regulators

Fisher C1 Pneumatic Controllers and Transmitters

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

Type ACE95jr Tank Blanketing Valve

Type FEQ Slam-Shut Valve

Becker* Model FD-1500 Filter/Dryer

V DGX Series. Direct-Operated Regulators Manual D103834X012

Installation, Operation and Maintenance Manual for Back Pressure Regulator

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

630 Series Regulators and Relief Valves

Transcription:

VBL Volume Booster Instruction Manual Release: August 2013

Instruction Manual Table of Contents August 2013 Table of Contents Section 1: Introduction 1.1 Scope of Manual... 1 1.2 Description... 1 1.3 Specifications... 2 1.4 Educational Services... 3 Section 2: Installation 2.1 Mounting... 4 2.2 Pressure Connections... 5 2.3 Supply Pressure... 5 2.4 Exhaust Ports... 5 Section 3: Operating Information Description... 6 Section 4: Principle of Operation Description... 7 Section 5: Maintenance Description... 8 Table of Contents I

Instruction Manual Section 1: Introduction August 2013 Section 1: Introduction 1.1 Scope of Manual This instruction manual provides installation, operation, maintenance, and parts information for the VBL volume booster. Refer to separate instruction manuals for information regarding the valve body, actuator, and other accessories. Do not install, operate, or maintain a VBL volume booster without being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance. To avoid personal injury or property damage it is important to carefully read, understand, and follow all of the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office before proceeding. 1.2 Description The VBL volume booster is used in conjunction with a positioner on a throttling control valve to increase stroking speed. The booster has a fixed deadband (controlled by the seat-to-seat dimension of the supply and exhaust plugs) which is factory set during assembly and testing. In addition, the booster incorporates soft-seat construction and an integral bypass restriction to eliminate positioner saturation problems that can occur with volume boosters that do not have these features. Adjustment of the integral bypass restriction is necessary for system stability. This adjustment does not affect the deadband of the booster, but does permit the control valve to respond to small input signal changes from the positioner without sacrificing steady-state accuracy. It also allows the booster to deliver high-volume output for fast stroking when large, rapid input signal changes occur. The volume booster is used to improve stroking speed. If precision valve control is required, the use of a positioner is recommended. If you use the volume booster only with an actuator, for on-off control, the integral bypass restriction on the volume booster must be closed (turned fully clockwise). To facilitate diagnostic testing, you can install connectors and piping with the VBL volume booster. The O-rings and diaphragms in the VBL volume booster are HNBR (Hydrogenated Nitrile). HNBR demonstrates excellent temperature capability and shelf life over standard nitrile. Introduction 1

Section 1: Introduction August 2013 Instruction Manual 1.3 Specifications Specifications for the VBL volume booster are listed in table 1. Information for an individual unit as it comes from the factory appears on the nameplate. Table 1. Specifications Input Signal Positioner output Maximum Input Signal Pressure (1) VBL-1 and VBL-3: 5.5 bar (80 psig) VBL-2 and VBL-4: 10.3 bar (150 psig) Input to Output Pressure Ratio Fixed at 1 to 1 Supply Pressure Ranges (1) When used in conjunction with a positioner or other pneumatic accessory, always pipe the positioner and booster with one common supply through a regulator (see figure 3). A high-capacity filter should be installed in the supply line to the regulator. Supply pressure also must not exceed the maximum pressure rating of the actuator. Operative Temperature Limits (1) -40 to 93 C (-40 to 200 F) Maximum Flow Coefficients See Table 2. Connections Input Signal: 1/4 NPT Supply and Output Signal: 1/2 NPT Hazardous Area Classification Complies with the requirements of ATEX Group II Category 2 Gas and Dust II 2 G D Approximate Weight Aluminum Body: 1.0 kg (2.2 pounds) Declaration of SEP BETTIS declares this product to be in compliance with Article 3 paragraph 3 of the Pressure Equipment Directive (PED) 97 / 23 / EC. It was designed and manufactured in accordance with Sound Engineering Practice (SEP) and cannot bear the CE marking related to PED compliance. However, the product may bear the CE marking to indicate compliance with other applicable European Community Directives. NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology. 1. The pressure/temperature limits in this document, and any applicable code or standard limitation should not be exceeded. Table 2. Maximum Flow Coefficients Instrument Supply Port Coefficients Exhaust Port Coefficients C v C v VBL - 1 volume booster 2.5 1.1 VBL - 2 volume booster 2.5 1.1 VBL - 3 volume booster 2.5 1.8 VBL - 4 volume booster 2.5 1.8 2 Introduction

Instruction Manual Section 1: Introduction August 2013 1.4 Educational Services For information on available courses for the VBL volume booster, as well as a variety of other products, contact: Emerson Process Management Educational Services, Registration P.O. Box 190; 301 S. 1st Ave. Marshalltown, IA 50158-2823 Phone: 800-338-8158 or Phone: 641-754-3771 FAX: 641-754-3431 e-mail: education@emerson.com Introduction 3

Section 2: Installation August 2013 Instruction Manual Section 2: Installation WARNING Always wear protective clothing, gloves, and eyewear when performing any installation procedures to avoid personal injury. System damage may result if a volume booster is installed in a way that it can be physically damaged. Personal injury or system damage may result when service conditions exceed booster or other equipment ratings. Exceeding the pressure specifications in table 1 may cause leakage, parts damage, or personal injury due to bursting of pressure-containing parts or explosion of accumulated gas. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. NOTE Do not use separate pressure supplies for the volume booster and associated positioner. The volume booster may not exhaust immediately upon loss of a separate pressure supply. However, if the system is in a transient state at the time of pressure supply loss or if changes to the booster s input signal are sufficient to overcome the deadband, the booster will exhaust. Always pipe the positioner and the volume booster with one common supply. See figure 3 for typical installation examples. A regulator is required to provide sufficient capacity to supply both components. A high-capacity filter, should be installed in the supply line to the regulator. 2.1 Mounting The volume booster is typically nipple-mounted between the pneumatic supply source and the actuator, and may be used with piston or diaphragm actuators. Many actuators require larger casing or cylinder connections and modifications to allow the booster to deliver the higher volume output. The booster may also be directly mounted to the actuator by using an actuator yoke mounting bracket (see figure 1) or casing mounting bracket. If a mounting bracket is used, remove the appropriate end cap screws and install the mounting bracket. Install the end cap screws, retightening to a recommended torque value of 12.5 N-m (110 lbf-in). 4 Installation

Instruction Manual Section 2: Installation August 2013 Figure 1 Volume Booster with Yoke Mounting Bracket HEX SCREW (QTY 6) HEX SCREW (QTY 6) ATTACH THIS SURFACE TO ACTUATOR YOKE YOKE MOUNTING BRACKET YOKE MOUNTING BRACKET 2.2 Pressure Connections The input signal connection is 1/4 NPT. The supply and output connections are 1/2 NPT (minimum pipe size recommended for nipple mounting is 1/2 NPT). Connections to the volume booster should be made as indicated in figure 3. Connections for typical applications are shown in figures 4 and 5. Ensure that the piping is of proper size to meet the capacity demands of the booster and that you equip the actuator with properly sized input connections. 2.3 Supply Pressure Supply pressure must be filtered, clean, dry air or noncorrosive gas. WARNING If a flammable or hazardous gas is to be used as the supply pressure medium, personal injury, property damage or equipment damage could result from fire or explosion of accumulated gas or from contact with hazardous gas. The volume booster has no provision for piping away the vented exhaust gas. Therefore, do not use flammable or otherwise hazardous gas as a supply medium unless the unit is in a well-ventilated area and all ignition sources have been removed. 2.4 Exhaust Ports Exhaust to the atmosphere is through exhaust ports in the side of the unit. Keep the exhaust ports free of any obstructions or foreign materials that might clog them. Installation 5

Section 3: Operating Information August 2013 Instruction Manual Section 3: Operating Information The only operating requirement of the volume booster is the adjustment of the bypass restriction for stable actuator performance. Although systems with different characteristics may require different adjusting techniques, the following adjustment procedure is recommended when using the actuator for throttling control. NOTE When sizing the booster, select the lowest C v that will meet the stroking speed specifications. Oversizing the booster in a closed loop may lead to stability problems, thus requiring the bypass to be opened so far that the booster will never operate. Prior to operation, turn the bypass restriction adjusting screw (figure 2) four or five turns counterclockwise from the fully closed position. With the actuator in operation, slowly turn the restriction clockwise until the booster operates in response to large changes in the input signal, yet allows small changes to move the actuator without initiating booster operation. Figure 2 Volume Booster Sectional View SPRING SEAT UPPER SPRING HOUSING, TOP HEX NUT BYPASS RESTRICTION ADJUSTING SCREW INPUT SIGNAL EXHAUST PORT HEX SCREW UPPER DIAPHRAGM DIAPHRAGM SPACER PIN, SLOTTED SPRING BYPASS VALVE DIAPHRAGM PLATE ASSEMBLY (INCLUDES LOWER DIAPHRAGM) O-RING EXHAUST HOUSING, BOTTOM SUPPLY PORT SUPPLY OUTPUT TO ACTUATOR O-RING END CAP LOWER SPRING VALVE PLUG ASSEMBLY LUBRICANT If the actuator is to be used for on-off control, the restriction should be closed (turned fully clockwise). Verify that the capacity of the regulator meets the stroking capacity requirements. 6 Operating Information

Instruction Manual Section 4: Principle of Operation August 2013 Section 4: Principle of Operation Refer to figures 2, 3, and 4. Because of the restriction, large input signal changes register on the booster input diaphragm sooner than in the actuator. A large, sudden change in the input signal causes a pressure differential to exist between the input signal and the output of the booster. When this occurs, the diaphragms move to open either the supply port or the exhaust port, whichever action is required to reduce the pressure differential. The port remains open until the difference between the booster input and output pressures returns to within the deadband limits of the booster. With the bypass restriction adjusted for stable operation, signals having small magnitude and rate changes pass through the bypass restriction and into the actuator without initiating booster operation. Both the supply and exhaust ports remain closed, preventing unnecessary air consumption and possible saturation of positioner relays. Figure 3 Typical Installations with Piston Actuator PIPE NIPPLE VBL VOLUME BOOSTER SUPPLY SIGNAL TOP CYL REGULATOR ACTUATOR BOTTOM CYL POSITIONER Figure 4 Typical Installations with Diaphragm Actuator VBL VOLUME BOOSTER PIPE NIPPLE SUPPLY SIGNAL REGULATOR ACTUATOR DIGITAL VALVE CONTROLLER OR POSITIONER Principle of Operation 7

Section 5: Maintenance August 2013 Instruction Manual Section 5: Maintenance There are no repairable or replaceable parts on the VBL volume booster. Contact your Emerson Process Management sales office if a replacement VBL volume booster is needed. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection,use, and maintenance of any product remains solely with the purchaser and end user. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. 8 Maintenance

Contact Us: Emerson Process Management, Valve Automation facilities at your nearest location: North & South America Middle East & Africa Europe Asia Pacific 19200 Northwest Freeway Houston, TX 77065 T +1 281 477 4100 F +1 281 477 2801 2500 Park Avenue West Mansfield, OH 44906 USA T +1 419 529 4311 F +1 419 529 3688 13840 Pike Road Missouri City, Texas 77489 USA T +1 281 499 1561 F +1 281 499 8445 Av. Hollingsworth, 325, Iporanga Sorocaba, SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 P. O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 P. O. Box 105958 Abu Dhabi United Arab Emirates T +971 2 697 2000 F +971 2 555 0364 P. O. Box 3911 Al Khobar 31952 Saudi Arabia T +966 3 814 7560 F +966 3 814 7570 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 P. O. Box 32281 Doha Qatar T +974 4 576777 F +974 4 315448 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908; Greenstone; 1616 Modderfontein, Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 Asveldweg 11 7556 BR Hengelo (O) The Netherlands T +31 74 256 1010 F +31 74 291 0938 Siemensring 112 47877 Willich Germany T +49 2154 499 660 F +49 2154 499 6613 25, Rue de Villeneuve Silic BP 40434 94583 Rungis France T +33 1 49 79 73 00 F +33 1 49 79 73 99 Via Montello 71/73 20038 Seregno (Milan) Italy T +39 0362 2285 207 F +39 0362 2436 55 6 Bracken Hill South West Industrial Estate Peterlee SR8 2LS United Kingdom T +44 191 518 0020 F +44 191 518 0032 2A Szturmowa Str 02-678 Warsaw Poland T +48 22 45 89 237 F +48 22 45 89 231 C/ Francisco Gervás, 1 28108 Alcobendas Madrid Spain T +34 0913 586 000 F +34 0913 589 145 No. 9 Gul Road #01-02 Singapore 629361 T +65 6501 4600 F +65 6268 0028 9/F Gateway Building No. 10 Ya Bao Road Chaoyang District Beijing 100020, P.R.China T +86 10 8572 6666 F +86 10 8572 6688 No.1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P.R.China T +86 22 8212 3300 F +86 22 8212 3308 Lot 13112, Mukim Labu Kawasan Perindustrian Nilai 71807 Nilai, Negeri Sembilan Malaysia T +60 6 799 2323 F +60 6 799 9942 471 Mountain Highway Bayswater, Victoria 3153 Australia T +61 3 9721 0200 F +61 3 9720 0588 Delphi B Wing, 601 & 602 6th Floor, Central Avenue Powai, Mumbai 400 076 India T +91 22 6662 0566 F +91 22 6662 0500 Letnikovskaya Str. 10-2 115114 Moscow Russia and FSU T +7 495 981 98 11 F +7 495 981 98 10 Please visit our web site for up to date product data. www.emersonprocess/bettis.com All Rights Reserved. We reserve the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser. 2013 Emerson Electric Co.