Continuous Culture of Rurnen Bacteria: Apparatus

Similar documents
APPENDIX. working blood volume was also rather large; Evans, Grande, and. equilibrated to the new mixture is partially dependent upon the rate

Working correctly with gas

Columbus Instruments

Technical Bulletin AL-134

(Received 9 September 1940)

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

Experiment 18 Properties of Gases

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

NOTES ON WATER HAMMER. 55

PRESSURE MYOGRAPH - 114P PULSATILE PRESSURE MYOGRAPH - 112PP

Cell Disruption System

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Setting up and running a column

7.9. Flash Column Chromatography Guide

Electron Microscopy Centre

Part 1: Distillation and Analysis of an Unknown Alcohol Mixture

After filling the pool with clean water in the summer, two basic factors can take place due to the exposure of water to the sun and the air.

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

INSTALLATION INSTRUCTIONS

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

Instructions for use Compressed air injector with water trap

Refrigeration Scroll For Parallel Applications

LABORATORY TECHNIQUES. Pouring Liquids

[285] NOTE ON A SIMPLE GAS-CIRCULATING PUMP

AN APPARATUS FOR THE CULTURE OF WHOLE ORGANS

Radnoti Liver Perfusion System

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

Design of an Automated Perfusion Pump James J Higham

How to use Solvent Purification System A brief manual

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Operating Instructions

Procedure of Xenon Transfer

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

EHS Laboratory Guidance: Cryogenic Material

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Accu-Tab Systems 2000 P Series by Axiall Corporation

Oxygen Contamination

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

Hydraulic Punch Drivers

Steam penetration in steam sterilization processes

Air Operated Hydraulic Pumping Systems to 50,000 psi

HYDRAULIC CYLINDER TEST

Accu-Tab Systems 1000 Series by Axiall Corporation

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID

Axial Compression Packing Method

USER GUIDE, VOL.2.0 MYOGRAPH SYSTEM - 112PP/114P

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

Pipette apparatus. Meet the difference. Manual. T E I

Chemistry 261 Laboratory Experiment 6: Reduced Pressure Distillation of a Mixture of High Boiling Alcohols

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice. Christine Slater PhD

ACCU-MIX 1200 / / 26270

METHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam

Super-Clean SCT Series SuperClean Sand Filter. Installation Manual

MS.RAJA ELGADY/PRESSURE PAPER 3

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

Generating Calibration Gas Standards

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

BOYLE S / CHARLES LAW APPARATUS - 1m long

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

MB-SP Series Solvent Purification System

STERILIZABLE DISSOLVED OXYGEN SENSORS

Procedure for Operation of the Gilson Respirometer

Unit 24: Applications of Pneumatics and Hydraulics

Introduction to Pumps

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

OWNER S TECHNICAL MANUAL

Aerobic reoxidation in marine sediments

Installation of Your SprayMaster System

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

HBLT-A1 LIQUID LEVEL SENSOR

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

SOP for use of the SX19 Stopped-Flow Instrument

K32230 DEW-POINT APPARATUS

Operating Instructions

Digester Processes. 1. Raw Sludge Pumping System

User's Manual. MixRite TF 10. Edition 05.08

R-410A 50% R-32 50% R-125.

A N F G J I C D D L A B C D E F

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

B. Assemble the Method-25 sample train with a heated probe/filter.

InFlow Modular perfusion bioreactor

Ultima Salt System Overview

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Armfield Distillation Column Operation Guidelines

Budget Range Operators Handbook

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Transcription:

J. gen. Microbiol. (1965), 38, 161-166 Printed in Great Britain 161 Continuous Culture of Rurnen Bacteria: Apparatus BY P. N. HOBSON Rowett Research Institute, Bucksburn, Aberdeen, (Received 10 March 1964) SUMMARY A small-scale apparatus for the continuous culture of anaerobic bacteria is described. INTRODUCTION The continuous culture of micro-organisms has been studied for a number of years and the most successful designs of apparatus have been based on the chemostat of Monod (1950) and Novick & Szilard (1950), and the turbidostat of Fox & Szilard (1955). As Herbert (1958) pointed out, the chemostat and turbidostat are essentially the same apparatus but they work best over different ranges of growth rate. The chemostat has some advantages over the turbidostat mechanically and for growth at low growth rates, and a chemostat type of apparatus was chosen for our work. Most of the chemostats described have been for the growth of aerobic bacteria and a problem in these designs is to supply sufficient air to the microorganisms, and this has led to the design of apparatus in which a film of culture flows around the walls of a vessel (e.g. Monod, 1950, and others; Dawson, 1963). This type of apparatus is not so suitable for anaerobic work as the stirred fermenter type. The most important rumen bacteria are strict anaerobes which require special techniques for handling and are unable to initiate growth unless the media used are highly reduced. The apparatus described here was developed after initial experiments some 5 or 6 years ago when a ph-controlled batch culture apparatus was built in which large amounts of Streptococcus bovis were grown for the isolation of a polysaccharide. The merits of continuous culture for providing large amounts of micro-organisms for enzyme work and for analysis then became apparent. The rumen may be likened to a kind of continuous culture and it seemed that a better understanding of the behaviour of rumen bacteria might be obtained if they were grown in continuous, rather than batch, culture. The development of a comparatively large apparatus with an external culture circuit in which was incorporated the ph controls proved unsuccessful for strict anaerobes, partly because of the long lengths of silicone tubing involved in the peristaltic pumps. Sufficient air to oxidize the medium can diffuse through silicone tubing. The apparatus was then redesigned on a smaller scale for growth of strict anaerobes. The mechanically stirred fermenter designs such as those of Elsworth, Meakin, Pirt & Capell (1956) were not followed because of expense and the difficulties of sealing the stirrer bearings, and because the bacteria which it was proposed to grow showed signs of being rather fragile and it was felt that a rapidly revolving stirrer might damage the organisms. A magnetic stirrer would overcome the difficulties of sealing bearings, but would still be liable to cause mechanical damage to the organisms. As a Vol. 88, No. 1, was issued 15 February 1964 I1 G. Microb. XXXVIII

162 P. N. HOBSON beginning the ph control was left out, the buffering action of the medium being relied on for ph control, but it has been found possible to incorporate in a larger vessel (250 ml.) an internal electrode system operating, through a ph meter and relay, solenoid-operated alkali and acid inlets. Since experiments at low growth rates were planned to involve doubling times of 7 or 8 hr or more, it was felt that the apparatus must be capable of running for much more than a day or two; and if it were to supply organisms for enzyme work it should run more or less indefinitely with minimum attention. The simplest design was used and all the parts of the present apparatus have been found necessary for its efficient functioning. The apparatus was demonstrated to the Physiological Society (Hobson & Smith, 1962) and a brief description was given in 1963 (Hobson & Smith, 1963). APPARATUS AND METHODS The apparatus (shown diagrammatically in Fig. 1) consists of the following parts. All joints are B5 ground glass joints, Rubber tubing is heavy wall red rubber of internal diameter approx. Q in, All rubber to glass joints are taped and wired on. A is a plastic balloon which holds about 5 1. of CO, under atmospheric pressure. This is attached to the 5 1. flask B through a cottonwool filter and replaces the medium from flask B with CO,. When the CO, in A is at more than atmospheric pressure it forces medium through the pump valves. Flask B is joined by rubber tubing and glass joints to a 2 1. conical flask C which is in a water bath at 39". Flask C is then joined through a g in. rubber tubing to the inlet pump D. The distance between C and D is made as short as possible. The main purpose of heating flask C is to prevent bubble formation as the C0,-saturated medium is drawn up into the pump. Small bubbles stick to the ball valves of these pumps and stop medium flow at low pumping speeds. The inlet tube between D and F contains a gas-gap (E) which prevents back-growth of the culture up the inlet tube and into C. As this gap tends to fill with medium during long runs it was found most convenient to allow a very small stream of CO,, controlled by a fine jet and screw clips on the tubing M, to pass through a filter into the side arm of E. Passage of a rapid flow of CO, in with the medium tends to suck medium through the pumps. F is the culture vessel, of working volume 120 ml., and it is fitted with a heavy rubber bung through which pass the tubes shown and an inoculation port, a B 5 cone and socket, G. The vessel is in a water bath at 39'. H is a subsidiary pump circuit, helping to stir the culture, but also acting as a sampling point through the two-way tap fitted with a hooded outlet tube. The main stream of CO, passes from the 50 lb. cylinder Q through a reduction valve, a 'Rotameter' flow meter P, a furnace containing red hot copper turnings (0), through the branch point N and cottonwool filters to the culture vessel. The tubing of the C02 line is pressure tubing which allows a negligible amount of air to permeate through, except for the short branch M which is Q in. tubing. The CO, escapes from the culture vessel by the overflow tubing and carries excess medium with it into the 2 1. flask I which is immersed in a refrigerated tank at 1'. I is fitted with a bunsen valve and cottonwool filter (J) through which excess CO, escapes. The outlet tube K is fitted with a tap and ground glass joint to which can be attached the flask L fitted with a cottonwool filter and a glass tube which can be attached to a water vacuum pump. Screw clips are attached at various points in the circuit.

Continuous culture apparatus 163 Between experiments the rubber tubing and cottonwool filters are usually replaced and the whole apparatus thoroughly cleaned. The culture vessel head with inlet pump circuit is separately wrapped, as are the circulating pump circuit, the flasks I and L, and the tops of the various flasks. All the separate pieces of apparatus are autoclaved at 120' for 25 min. to ensure thorough heating of pumps, etc. The various joint ends are separately covered under the main wrappings. The sterile apparatus is rapidly assembled as far as the joint below the pump D, the pumps are connected to the motors and connexions made from the CO, lines to the filter inlets. The medium is separately prepared in flasks C and B. The basal medium, without bicarbonate, cysteine and carbohydrate, is autoclaved in the flasks, which are fig. 1. Continuous culture apparatus. Diagrammatic. The lettered parts are referred to in the text. The hatched areas are cottonwool filters. closed with aluminium foil, for 25 min. at 120. On removal from the autoclave, whilst the medium is still hot, the aluminium foil caps are replaced by the bungs carrying the inlet tubes, etc., but with a rubber bladder (a football bladder) of pure CO, attached through a filter to the medium outlet tube, as in R. The other tube with the filter is clipped off. Before the bungs are pressed home a strong stream of CO, is bubbled through the medium to displace air in the flasks, When the medium has cooled a little, to say 60, the bung is displaced and a concentrated solution of bicarbonate + cysteine + carbohydrate (filter sterilized) rapidly poured in whilst CO, is allowed to escape around the bung. The bungs are then firmly pressed down and sealed with wax. (The top of the culture vessel and other bungs are also sealed with wax.) The medium is then allowed to cool and as it cools CO, is drawn in from the attached balloon. (By opening the clips the filters and tube joining B and C are filled with CO,.) This takes some hours and the flasks are then incubated overnight to test for sterility. When the apparatus has been assembled CO, is passed through for at least two hours before the medium flasks are connected to each other and to the inlet pump joint. In connecting up, the tubes are clipped as near to the joints as possible and the joints rapidly connected to allow as little air as possible to get into 11-2

164 P. N. HOBSON the joints. The balloon A is attached to flask B. Carbon dioxide is allowed to flow through the apparatus for a further half-hour and the medium is then slowly pumped from flask C into the culture vessel, Filling the vessel takes an hour or more, and any residual air in the inlet tubing and pump D is pushed out before the advancing medium and flushed out by the CO, flow before it can oxidize the medium to any extent. Similarly, any air in the circuit H is driven out by the action of the pump. When the vessel is filled the CO, flow is left on at about 50 ml./min., the pumps are stopped and the whole apparatus left overnight to test for sterility. The vessel can then be inoculated through G and the bacteria allowed to grow as a batch culture to a suitable population density before the medium inflow and the pump H are started. To empty the reservoir I the inlet pump is stopped and the tubing below D closed with a screw clip; otherwise medium is sucked through the pump into the vessel. Flask L is then attached to the tube K and slight suction applied to L. By opening the tap on K liquid is allowed to flow slowly between I and L. I is emptied slowly as otherwise too great a vacuum is caused in the flask and the medium in the culture vessel froths vigorously as the CO, flow increases. The flow of liquid from I to L is stopped occasionally to allow the pressure in I to build up again. The cottonwool filter below J stops contamination, if by chance the bunsen valve at J leaks during this process After I has been emptied the apparatus is left to equilibrate for a few minutes before the clip at D is opened and the pump again started. A 2 1. flask was chosen at C partly because when the medium level in B falls the flow of liquid from B to C does not always fully coincide with the flow out of C and the level in C falls. If during a long run the level in C falls too much it is brought back to normal by pushing a hypodermic needle attached to a cottonwool filter through a sealed-off rubber tubing projecting from the top of C (this is not indicated in Fig. 1) after the tubing has been washed with ethanol, and applying gentle suction. The medium flask B is changed when necessary by closing the rubber tubing near the joint above B and rapidly changing the flask for a similar one. The pumps have had no parts changed during 2& to 3 years of experiments, and have only needed regular cleaning and greasing of the gear boxes and bearings; some wear in the stainless-steel piston rods is now becoming apparent though, and these will need changing soon. The copper in the furnace tube is changed occasionally and this can be done during a run when necessary, without getting air into the system. The CO, cylinder is always changed well before it is empty as the rate of flow of the last of the gas out of the cylinder is uncertain, PERFORMANCE OF THE APPARATUS Since the water bath containing the culture vessel is large and well stirred the temperature of the medium remains very close to 39", even with the circulating pump H running. The pump H runs continually. The refrigerated bath is thermostatically controlled and cooled by a small refrigerator unit (Grant Instruments, Cambridge). The water in the warm baths is covered with mineral oil to cut down evaporation. Otherwise water tends to distil from the hot baths to the cold glycol solution in the refrigerated bath and raises the level in the latter. When this level gets too high it cools the thermostat unit and water condenses on it and this can

Continuous culture apparatus 165 short circuit the motor or thermostat switch. All electrical connexions in the unit have been covered with a plastic film (Holts, Damp-Start ) to cut down risks of short circuiting. The pumps are Distillers Co. (Great Burgh, Epsom, Surrey) Micro pumps, of the original type. The newer Series I1 pump is not so suitable because of a number of points in its construction. Aluminium housings have been built over the pump plungers to cut down dust contamination, and a little ethanol is sprayed over the plungers and glands each day. The pump glands need fractionally tightening each day to take up slack due to wear. Occasionally the Teflon gland packing is renewed (after say 6 months use). The inlet pump will pump a maximum of 175 ml./ hr, and the circulating pump is a bigger model set to pump about 650 ml./hr. The calibration curve of the inlet pump varies from one run to another, but is of constant slope. The calibration in the apparatus also differs from the calibration obtained by pumping water from one vessel to another. The rate of pumping is checked during a run by measuring the volume flowing into the refrigerated reservoir. Variations in pumping speed occur during a run at one setting, but the variation is small. Typical results over 200 hr at a setting to give a dilution rate about 0.2 hr-1 were D = 0.188, 0.181, 0.181,0.212, 0.218, 0.207,0.199, 0.186, 0.184, the volumes pumped being measured at approximately 20-hr intervals. The flow of carbon dioxide through the culture vessel is 100 ml./min. This mixed a dye solution flowing into the vessel in about 1 sec. The gas stream impinges on the bottom of the vessel and prevents micro-organisms from settling. Foaming in the vessel has never been serious at the gas flow-rates used, the usual result being a layer of large bubbles about 5 mm. thick or less on top of the medium. Evaporation caused by the gas stream is not serious, amounting to not more than about 2 % of the volume in an overnight batch culture. When the gas flow is above 100 ml./min. then foaming increases, but flow can drop lower than 100ml./min., without seriously affecting mixing. The circulating pump alone is not sufficient to stir completely the culture if the gas flow should fail entirely, but this has seldom happened. Provided that contamination is avoided initially there is little chance of subsequent contamination unless a breakage occurs in one of the glass parts. When contamination has occurred it has usually proved impossible to wash it out completely, even if the contaminating organism (usually a micrococcus) has not swamped the normal growth. Some applications of the apparatus are described in the next paper. The author wishes to thank Mr W. Smith for assistance during this work. REFERENCES DAWSON, P. S. S. (1963). A continuous flow culture apparatus. The cyclone column unit. Can. J. Microbiol. 9, 671. ELSWORTH, R., MEAKIN, L. R. P., PIRT, S. J. & CAPELL, G. H. (1956). A 2 litre scale continuous culture apparatus for micro-organisms. J. appl. Bact. 19, 264. Fox, M. S. & SZILARD, L. (1955). A device for growing bacterial populations under steadystate conditions. J. gen. PhySioZ. 39, 261. HERBERT, D. (1958). In Recent Progress in Microbiology, 7th int. Congr. for Microbiology. Stockholm.

166 P. N. HOBSON HOBSON, P. N. & SMITH, W. (1962). Continuous culture of anaerobic rumen bacteria. J. Physiol. 164, 6P. HOBSON, P. N. & SMITH, W. (1963). Continuous culture of rumen bacteria. Nature, Lon&. 200, 607. MONOD, J. (1950). La technique de culture continue. ThCorie et applications. Annls Inst. Pasteur, Paris, 79, 390. NOVICK, A. & SZILARD, L. (1950). Description of the chemostat. Science, 112, 715.