h2000 plus HyDROGEN LEAk DETECTOR

Similar documents
COMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS ASM 182 SERIES

HIGH PERFORMANCE LEAK DETECTORS ASM 182 SERIES / ASM 192 SERIES

628 Differential Pressure Decay Leak Tester

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS

Protec P3000 (XL) Helium Sniffer Leak Detector

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

PHOENIX L300i Best-in-class Helium Leak Detectors

Your local gas generation partner. Precision series Modular gas generation solution for GC.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Columbus Instruments

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Your local gas generation partner. Precision series Modular gas generation solution for GC.

COSMO INSTRUMENTS CO., LTD.

The Helium Leak Detector

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

IRwin Methane Leak Detector. Innovation makes the difference

Optimization of a Proven Technology

Model Description

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Dräger RZ 7000 Test Equipment

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

DIAPHRAGM GAS SAMPLING PUMPS

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Frazier Permability Tester & Average Fiber Diameter Analyzer. Permeability measurement according to ISO: 4003 & ASTM D standard

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Aquacom Diving Equipment

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Selecting the right pressure sensor for your application

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Liquid Ring Compressors Engineered-to-Order Compressor Systems

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

EasyLine Continuous Gas Analyzers. So smart, they re simple

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Autocalibration Systems for In Situ Oxygen Analyzers

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Hydrogen Leak Detector Sensistor ISH2000

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Gas-Detection Instruments

Customer Responsibilities


SCIENCE LAB UTILITY CONTROLS

Dräger-Tube pump accuro Dräger Tube Pump

Advanced Test Equipment Rentals ATEC (2832)

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

AUTOMATIC HOSE TEST UNIT, TYPE SPU

We measure it. For gas and water installers. testo hpa. bar

Rapid and Reliable Detection of Dissolved Gases in Water

The New PHD 4 Portable Helium Detector

Multi Fibres. MiniFant M99 insulation blowing MacHinE

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Manual of SF6 Comprehensive Tester

HydroCOM: High energy savings and excellent controllability

How much do customer returns cost you?

CalCheck. Instrument User Manual V1.8

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

BUDDY Gorgeous and easy to use GPS Navigation Kit USER GUIDE. Love from Intempo Digital xx

O NEof Premium tools for professionals!

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

The latest automotive systems require innovative leak test methods and fixturing.

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

RAM 4021-DPX Operation Manual

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

LEAKHUNTER Plus Model 8066

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

HYDROCHLOR. Salt water pool chlorinator.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

RAM Operation Manual

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

testo Leakage detector for refrigerants Instruction manual

Qi Litre Ultrasonic Cleaner

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand

Dräger RZ 7000 Test Equipment

RAM 4021 Operation Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Chapter 6 Leak detection

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Transcription:

H2000 plus hydrogen leak detector

hydrogen leak detector h2000 plus Fast, easy to use, and durable. Leak testing with Hydrogen tracer gas The Hydrogen Method Detecting leaks using Hydrogen, called the Hydrogen Method, is today an established industrial method. Sensistor Technologies, today Adixen, launched its first leak detection system based on the Hydrogen tracer gas method more than 20 years ago. A wide range of industries all over the world use this method today. It is an excellent tracer gas technique because it requires no vacuum and because Hydrogen is a sustainable natural resource and a less expensive tracer gas.

Hydrogen Leak Detector H2000 PLUS - a breakthrough in leak detection Unique and reliable The Hydrogen Leak Detector H2000 PLUS is a unique instrument for industrial leak detection. It is small, robust, and extremely sensitive to Hydrogen gas. It can be used to detect leaks as small as 1x10-7 mbarl/s. It is also insensitive to other gases and has a unique capability of handling background levels of Hydrogen gas. In other words, everything required for sensitive and reliable testing. The optimal tracer gas Leak detection using the Hydrogen Method is an established industrial standard. One reason for this is that Hydrogen is the cheapest tracer gas available. The actual gas mix used is a safe mixture of 5% Hydrogen in Nitrogen. Another reason is the inherent characteristics of Hydrogen. Hydrogen is the lightest and least viscous of all gases. It spreads very quickly throughout the test object and seeps quickly through the smallest leak. Background interference is easily minimized because of the speed with which Hydrogen dissipates. The method requires no pumps or vacuum and thus needs a minimum of maintenance. Gives more possibilities When using the Hydrogen Method and H2000 PLUS, leak detection is no longer a choice between a water bath, pressure testing, and a mass spectrometer. Now you can customize your solution to suit you requirements and budget. Hydrogen tracer gas detection with the H2000 PLUS offers flexible solutions that have not previously been available. For example, you can measure pressure drop in order to disclose leaks and locate them with Hydrogen tracer gas. Or you can use Hydrogen tracer gas and H2000 PLUS to detect leaks with high sensitivity, independent of temperature. A modern method Leak testing using tracer gas is used when it is unsuitable to put the test object in a water bath, when pressure decay cannot be used because of temperature interference or when the test object is elastic. Taking the step from water bath to leak detection with a tracer gas is considered to be a major one, both as regards price and complexity. But with the Hydrogen Method and the H2000 PLUS, the step to modern and efficient leak testing is much smaller. With the H2000 PLUS you minimize problems with background interference, because Hydrogen gas is dissipated much quicker than other gases and because the H2000 PLUS has dynamic background compensation. H2000 PLUS is entirely electronic. No pumps, valves, or other things that require main tenance. No service is thus needed. If the probe is damaged, the operator himself can replace it in just a couple of minutes. H2000 PLUS is small and robust. It is easy to move around when searching for leaks on a large object, e.g. an aircraft. It can also be easily transported in a suitcase when travelling, e.g. for a service engineer. H2000 PLUS is very easy to use. Switch on the power and wait just one minute. Then start searching for leaks. If the standard settings are unsuitable, change them simply by browsing through the menus on the display. H2000 PLUS is suitable for leak detection in tough factory environments. The standard H50 probe has no sample suction and can thus be used without worrying about dust. The probe can be equipped with a protective cover that allows leak detection on wet objects. H2000 PLUS is based on modern digital technology and does not require trimming or calibration other than by simply pushing buttons. It can be calibrated with a reference gas or a reference leak.

H2000 PLUS models h2000 plus table top model h2000-c plus mobile, battery operated model h2000-p plus panel model accessories AP29 sampling probe AP55 sniffer probe ap57 counter flow probe reference leaks for calibration AP29 automatically takes samples from test chambers or local test points. It is designed for integration into automatic leak test systems. Main features are automatic calibration and overexposure protection to minimize recovery time. AP55 enables immediate quantification of a specific leak at the exact location of the leak. While the standard probe H50 detects gas without drawing a sniffer flow, AP55 enables you to work with or without sniffer flow. AP57 is developed for use in confined spaces, such as engine compartments etc. where background build-up would normally mask off leaks. A unique system of air counter flow eliminates the effect of tracer gas in the background and allows leak locating where no other method works. To be able to correctly accept/reject test objects you need to measure to a set standard. Leak detectors also need to be calibrated against a reliable reference leak. The Adixen reference leaks for Hydrogen Leak Detectors covers a wide range of leak rates.

Facts about the tracer gas: Pure Hydrogen gas is never used as tracer gas, since it is highly flammable Instead, a gas mixture of 5% Hydrogen in Nitrogen is used This mixture is not flammable (refer to ISO 10156) This mixture is non-toxic, non-corrosive and pro-environmental Hydrogen is the lightest of all gases and consists of the smallest molecules. This is what gives Hydrogen gas unprecedented penetration ability, even through materials as dense as concrete. Hydrogen and Nitrogen both exist in all biological systems. Hydrogen gas is approved as a foodstuffs additive under code E949. Some gas suppliers have their own trade name for this gas mixture. Technical specifications Sensitivity: Leak detection with standard probe H50: 1x10-7 mbarl/s at 5% H 2 (eq. to 0,02 g/yr R134a) 2x10-6 mbarl/s at 5% H 2 with Sniffer Probe AP55 H 2 Analysis: 0,5 ppm H 2 Start up time: Calibration: Front panel: 1 minute External reference leak or calibration gas Illuminated 256 x 64 pixel LCD Loudspeaker Earphone socket Green LED for status Red LED for alarm Rear panel: D-Sub connector with status signals 24V DC / 0.5A Maintenance: Power supply: Dimensions: Weight: None 100-240 VAC, 50/60 Hz, 2 A 275x155x170 mm (10,8x6,1x6,9 inches) 4.1 kg (9 lbs)

China Technology Shanghai Tel: (8621) 5027 0628 Fax: (8621) 3895 3815 India Technology India Tel: (91) 124 473 7777 Fax: (91) 124 473 7799 Netherlands Technology Netherlands Tel: (31) 345 478 400 Fax: (31) 345 531 076 Taiwan Technology Taiwan Tel: (886) 3 5599 230 Fax: (886) 3 5599 231 France (Headquarters) Technology France Tel: 33 (0)4 50 65 77 77 Fax: 33 (0)4 50 65 77 89 Japan Alcatel-Lucent Japan Ltd Tel: (81) 3 6431 7130 Fax: (81) 45 544 0049 Singapore Alcatel-Lucent Singapore Tel: (65) 6254 0828 Fax: (65) 6254 7018 United Kingdom Technology (U.K.) Ltd Tel: (44) 1 506 418 000 Fax: (44) 1 506 418 002 Germany Alcatel Hochvakuum Technik GmbH Tel: (49) 9342 96 10 0 Fax: (49) 9342 96 10 30 Korea Technology Korea Tel: (82) 31 206 6277 Fax: (82) 31 204 6279 Sweden Adixen Scandinavia Tel: (46) 13 35 59 00 Fax: (46) 13 35 59 01 USA Products Tel: (1) 781 331 4200 Fax: (1) 781 331 4230 Italy Systems S.p.A. Tel: (39) 039 686 3855 Fax: (39) 039 667 125 www.adixen.com Publication: Adixen Scandinavia - Part Number AS60300-11/2009 - All information can be modified without prior notice.