Iron Filter Installation / Operation Manual

Similar documents
Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT

Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Vessel Installation and Operating Manual

Installation & Instruction Manual For Portable Series R.O. units:

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Installation and Operating Manual

Chloramines Removal Filter CLF20 and CLF35 Models

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Gas Countertop Hot Plates

Standard Gas Countertop Griddle

GAS FRYER Instruction Manual Model #5099NS

Installation Instructions Air Compressor Part # 2780, 2781

Easy Nest Kits. Installation Suggestions

Duplex Commercial Softeners

ChlorMaker DO OPERATING INSTRUCTIONS DO - DRAPE OVER

SPECIFICATIONS APCEPH1

INSTALLATION INSTRUCTION

CSA Sample Draw Aspirator Adapter Operator s Manual

Golf Performance Monitors. PureContact Operating Guide. Version of 9

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

The ultimate in water softening

265 Series Valve Operation Manual

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS

MODEL CALIBRATION GAS DELIVERY SYSTEM

4 and 8 Station PDS Control Installation & Operators Manual

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

453 Series Steam Heated Vaporizing Regulator

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

RAM 4021 Operation Manual

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

ChlorMaker DO OPERATING INSTRUCTIONS DO - DRAPE OVER

MODEL 100 NITROGEN INFLATION CART

BS Series Basket Strainer

NORMAL OPERATING DISPLAYS GENERAL OPERATION

INSTALLATION AND OPERATION INSTRUCTIONS

Yoke Block Instruction Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

PERSONAL AIR BREATHING UNIT

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Tsunami Breathable Air System

IonGen. Installation Instructions & Maintenance Owner s Manual. Electronic Clarifier for Ponds and Pondless Waterfall Systems

SP-110 Autopilot OPERATION

ROPV R40 E Series User Manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

8675/8677/8678 OWNER S MANUAL

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OWNER S MANUAL. Table of Contents

Modular skylight warranty

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL ZERO WASTE REVERSE OSMOSIS SYSTEM

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Accu-Tab Systems 2000 P Series by Axiall Corporation

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

6 digital caliper with case

Yoke Block Instruction Manual

Freedom8 ShoeBox Compressor Manual

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Portable Compressed CO 2 Regulator

PC1131 Electric Air Compressor

TECHNICHLORTM OPERATING INSTRUCTIONS

US Water Systems Synergy Model 9000/9100/9500 Service Manual

GALISO SOAP OPTION FOR PCT-ADW-D

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Nitrogen Supply System

Pure Water Power Purification System 4-Stage RODI Operations Manual

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Gemini Owner s Manual

Accu-Tab Systems 1000 Series by Axiall Corporation

Owners Manual 081-MXF-PH-XXX. US Water Systems Matrixx ph Balancing Backwashing Filter. Visit us online at

SElECTING A MOUNTING location OPERATING SPECIFICATIONS* * For individual cartridge specifications, refer to cartridge literature.

ULTRA QUIET & OIL FREE

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

OPERATING INSTRUCTIONS

OWNER S MANUAL & INSTALLATION GUIDE

HAS2400 Hepa Air Scrubber

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

PRS-11 Particle Reduction System OPERATIONS MANUAL REV A 3SEP08

J Air and Water Kit Instructions Part# 02584

G7S Hand Pump Owner s Manual

PORTER INSTRUMENT COMPANY, INC.

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

PARK AVENUE 7' POOL TABLE WITH TABLE TENNIS & BENCHES ASSEMBLY INSTRUCTIONS

Transcription:

Iron Filter Installation / Operation Manual BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster technical videos show how to set up or remove the control module. If returning your control module to be repaired/replaced, please use the (downloadable) Remanufactured Module Order Form.

Installation Procedure 1. Identify installation location. MEGAbite piping should originate shortly after incoming water supply shutoff, but just after any outside water lines, such that all water intended for interior use flows through MEGAbite first. IMPORTANT: there must not be any filters installed upstream of the MEGAbite, or insufficient water pressures may affect operational performance. This system and installation must comply with state and local laws and regulations. 2. Connect water piping. This unit has been supplied with a manually operated bypass device which enables it to be isolated from the water service lines for maintenance and service, and also maintain the continuity of the water supply when the MEGAbite is disconnected. IM- PORTANT: Make all sweat-solder connections within 6 inches of the unit before applying threaded fittings to supplied bypass valve. Overheating may cause damage to valve. Turn supplied bypass valve to Bypass position and make connections to household water lines. Leave unit in Bypass position until startup procedure. 3. Connect drain line. Remove barbed drain line fitting from parts bag. Apply thread seal tape to threads and turn into the female threaded opening on the back side of the control valve. Connect 5/8 drain line (supplied in parts bag) to barbed end of drain line fitting and run to a nearby drain. Be sure not to submerse drain line end into drain, as a 1 1/2 minimum air gap must be maintained to prevent potential backflow hazard. Firmly secure at drain, while maintaining a minimum 1 1/2 air gap (See detailed drawing on back side of piping diagram). 4. Connect to electrical power source. Connect power cord to a separate 120v, 15 amp, ground fault interrupt (GFI) outlet. Proceed to start-up procedure. Note: This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without disinfection before or after the system.

Start-Up Procedure Placing unit into service Normal Operation Mode Icon Flush the MEGAbite filter with water: Locate the nearest cold water faucet tap and open it. If there is a water softener installed downstream of the MEGAbite, close it s bypass valve until this step is completed. Slowly open MEGAbite bypass valve and let water run to the open faucet tap until it runs clear. This will flush any media residual from the filter and prepare the unit for service. Re-open water softener bypass (if installed). Proceed to setting current time of day.

Start-Up Procedure Setting current time of day Setting Current Time / Day 1. Press either the Up or Down buttons to adjust current time of day by one digit. Push and hold either up or down set button to adjust current time of day display by several digits. User programming User Programming Mode Options Abbreviation Parameter Description DO Day Override The timer s day override setting RT Regeneration Time The time of day that the system will regenerate. User Programming Mode Steps (Refer to chart above for user mode indications) 1. Press the Up and Down buttons for five seconds while valve is in service. Display will enter programming mode. (Note: Timer will discard any changes and exit programming mode if any button is not pressed for sixty seconds. 2. Set Day Override: This setting specifies the maximum number of days between regeneration cycles. System will regenerate regardless of usage if the days since last regeneration cycle equals the day override setting. This ensures regular regeneration periods. The preprogrammed factory recommended setting is 3 days.

Start-Up Procedure User programming (cont d) 3. Adjust Regeneration Time: Press the Extra Cycle button to advance to next option. This setting determines the time of day that the unit will enter the regeneration cycle. The most common / default setting is 12:30 AM. IMPORTANT: this regeneration time should be offset from any water softener s regeneration time by at least 2 hours to insure adequate regeneration pressure. Control programming is now complete. Press the extra cycle button, and the control will exit from the programming mode and resume normal operation.

Maintenance / Warranty Information Nearly all serviceable parts lie within the removable/replaceable APM module. This eliminates costly and time consuming field repairs. All BrassMaster and BrassMaster Plus water softeners / filters feature the Assured Performance Modular (APM) design. If you experience a failure of any valve component, the brass module can be easily removed and replaced with a factory remanufactured replacement module. Reference the BrassMaster and BrassMaster Plus Technical Video Library on our website (link is provided below) for detailed steps on how to remove the module. The required (downloadable) form to have your module repaired/replaced is also located at this site. Please contact your dealer or Water Control Corporation for module support. BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster technical videos show how to set up or remove the control module. If returning your control module to be repaired/replaced, please use the (downloadable) Remanufactured Module Order Form. For factory module support contact: Water Control Corporation 7150 143 rd Ave NW Ramsey, MN 55303 Phone: 1-866-405-1268 Fax: 763-427-5665 www.watercontrolinc.com

Official Warranty Water Control Corporation BrassMaster Plus Series Water Softeners / Filters Limited Warranty Water Control Corporation warrants the control valve to be free of manufacturers defects for a period of 5 (five) years from the date of installation, and the fiberglass reinforced mineral tank, and plastic brine tank, to be free from leaking due to manufacturers defects for a period of 5 (five) years. We will, at our discretion, repair or replace defective products. This warranty does not include any costs associated with removal of defective products, or installation of replacement products. All replacement parts will be provided FOB Ramsey, MN. This warranty is transferable. DISCLAIMER OF IMPLIED WARRANTIES Water Control Corporation makes no warranties except those expressly stated in this document. To the extent permitted by the laws of the applicable state, ALL WARRANTIES CONTAINED IN THIS DOCUMENT ARE EXPRESSLY IN LIEU OF, AND WATER CONTROL CORPORATION EXPRESSLY DISCLAIMS, ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. WHAT IS NOT COVERED BY THESE WARRANTIES 1. Conditions and damages resulting from any of the following: - Wear caused by unfavorable water conditions - Improper installation, delivery, or maintenance - Any repair, modification, alteration, or adjustment not authorized by the manufacturer or an authorized servicer - Misuse, abuse, accidents, or unreasonable use - Improper setting of any control - Incorrect electric current, voltage, or supply 2. Warranties are void if the original serial numbers have been removed, altered, or cannot be readily determined. 3. The cost of service or service call to: - Correct installation errors - Instruct the user on proper use of the product - Transport the product to the servicer 4. Any costs associated with removal of defective products, or installation of replacement products. 5. Consequential, special, or incidental damages sustained by any person as a result of the breach of these warranties. Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above exclusion may not apply to you.

Water Control Corporation 7150 143 rd Ave NW Ramsey, MN 55303 Phone: 1-866-405-1268 Fax: 763-427-5665 www.watercontrolinc.com