Operating Instructions Model and Hydrostatic Test Pump

Similar documents
Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

2 I All-Flo Pump Co.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

2 I All-Flo Pump Co.

Speed control assembly model A-1

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

DS06D,G Dial Set Pressure Regulating Valve

MANUAL BE SERIES Test Benches

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

D05 Pressure Regulating Valves

2.0 INSTALLATION & SERVICE

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Techcon Systems TS1254 Pressure Pot

1020 Industrial Drive, Orlinda, TN fax

Freedom8 ShoeBox Compressor Manual

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

DS05C,D,G Dial Set Pressure Regulating Valves

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

MAINTENANCE PROCEDURE FOR X 650

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

SINORIX Valve Reconditioning

Adjustable. Unloader Valve. O&M Manual. Part #

TECHNICAL DATA Q= C. Table 1 - Specifications

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

MANUAL: Jumbo Gate Valve

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Installation of Your SprayMaster System

FI-25V OWNER S MANUAL

Instruction Manual Updated 7/26/2011 Ver. 2.2

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Page 1 of 12

Standard Specifications

User Instruction Manual

TECHNICAL DATA CAUTION

User Manual for the Mars Calibration Bench

Hydraulic Punch Drivers

KJ4000 Operating Instructions & Parts Manual NSN

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Aquor House Hydrant V2

accidents which arise due to non-observance of these instructions and the safety information herein.

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

a. Next, lift the lever on pressure reducing valve to allow street pressure water into the system.

TECHNICAL DATA. Trimpac 244a. September 16, 2013

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

553 Series.

Pressure Dump Valve Service Kit for Series 2300 Units

Combination Air Valve

Installation Instructions for NP100 Series Nitrogen Control Panels

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ALF400 to 900, ALT-5/-9

OPERATION MANUAL NTF-15

VACUUM REGULATORS CONTENTS

Operating Instructions

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Universal Valve Company Inc

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

V43 Pressure Actuated Water Regulating Valve

III. Identify the initial installation requirements for standpipe systems

Universal Valve Company Inc

CATALYZER TM 2K 10:1 RATIO Pump

OPERATION MANUAL NTF-60 Plus

LEAK SEALING SYSTEMS

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

DIAPHRAGM PUMP MODEL PDM 1-175

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Introduction. Part one: Identify the Hydraulic Trainer Components

TECHNICAL DATA CAUTION

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

ELECTRONIC PLC SERIES Test Benches

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

1200B2 Series Service Regulators. Instruction Manual

Pressure Dump Valve Service Kit for Series 3000 Units

VB85/ Pressure regulating valve (Unloader)

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS HELMET AND EMERGENCY GAS SYSTEM DAILY SET-UP AND FUNCTIONAL CHECKLIST APPENDIX A2.

Types 749B and R130 Changeover Manifolds

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Installation and Operations Manual Index

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Discharge Relief Valve Operation & Maint.

Transcription:

Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose Ends Discharge Hose 5 (38cm) L x 0 (25cm) W x 8 (20cm) H 0.5lbs; 4.8 kg /.5 lbs; 5.3 kg 0-300psi (2 bar) 0-000psi (70 bar) Glycerin filled, 0-600psi (40 bar) Glycerin filled, 0-2000psi (38 bar) 3/4 Female Garden Hose 9/6-8 JICF Male 9/6-8 JICF Female Swivel x /4 Male NPT /4 ID x 0 Long Pressure Feed Method: (Preferred Method #) This is typically a residential water source with about 40 to 60 psi. Connect water supply hose to the garden hose inlet connection (E) on the pump. 2. Open valve and turn supply water on. 3. Purge the pump and pressure hose of all air. (You may have to pump the handle (B) a few times to get the water to flow out.) 4. Connect output (pressure) hose between pump (F) hose adapter and water line (or vessel) being tested. (Water line or test vessel should be pre-filled with water before the test pump is attached.) 5. Purge water line (or vessel) of all air at the highest point of the system. 6. Bring water line (or vessel) to pressure by quickly pumping handle (B). 7. Watch the gauge while pumping. As you reach the desired pressure; on the downward stroke turn the valve (C) to the off position. If pressure drops off, there is a leak in the line. Gravity Feed Method: (Preferred Method #2) This method requires a tank with a water outlet at the bottom. The water tank s outlet should be level with or above the level of the water inlet connection on the pump. This allows water to flow naturally into the test pump. Follow the Pressure Feed Method steps through 7 (listed above) 0605

Siphon Method Use a clean water source Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump. Fill the water line to be tested. 2. Fill the intake hose (hose is not supplied, require PN 34550) with water, then quickly place the hose into a bucket and start pumping handle. (The unit is self-priming once primed.) Continue to pump until you see the water coming out of the outlet, with little or no air mixed with it. 3. Connect the output hose to the water line. Continue on with steps 5 through 7 above. Pre-Setting Your Pump Your pump can be pre-set to a specific pressure easily by adjusting the pressure relief valve.. Unscrew (counter clockwise direction) pressure relief valve (D). (Note: the valve assembly will not come out of the casting body). 2. Add a ball valve (not supplied with pump) to the end of the high pressure hose. 3. Follow steps through 3 from the Pressure Feed Method above. 4. As water is flowing out of the high pressure hose, turn the ball valve to the off position. 5. Slowly start turning pressure relief valve (in the clockwise direction) by ¼ turn increments as you are pumping the handle, until you reach the desired pressure. 6. Your test pump is now pre-set. This eliminates over-pressurizing the water line (or the vessel). A B C F D A B C D E F Gauge Handle Ball Valve Pressure Relief Valve Garden Hose Inlet Connection Hose Adapter E

Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Troubleshooting Your Pump Test pressure not being reached: Possible air in air in line (or vessel) Air needs to be purged from system. Remove pump from system and follow steps through 6 of the Pre-Setting Your Pump section. If using the Siphon Method and not getting pressure. Try the Pressure Feed Method or Gravity Feed Method to ensure water is getting into the pump. Pressure relief valve not adjusted properly. Turn relief valve clockwise until it stops. Check ball is stuck (not allowing water into pump) Disconnect from water & drain. Rotate pump upside down and listen for check balls to rattle inside. Lightly tap the casting body with a wood block. Rotate & listen for check balls to rattle inside. Check O-rings for wear and or cracks. Replace if necessary with Wheeler-Rex rebuild kit PN #29250. Lightly grease each O-ring when rebuilding. Pump Maintenance Pump 50/50 antifreeze/water solution through pump after each use to avoid freezing & check balls from sticking. Rebuild Kit Wheeler Rex PN 29250 Suction Hose Wheeler Rex PN 34550 CAUTION!! This pump is designed for water only!! This pump is equipped with an adjustable pressure relief valve (D), which helps protect the system from being over pressurized. It can be preset by plugging the end of the hose. Turn the adjusting knob clockwise to increase pressure and counterclockwise to decrease.

38/ SS BALL STRAINER WASHER 27585 275435 27597 276806 OVERLOAD SPRING 5/6 SS BALL 20320 SCREEN RETAINER 220096 2243 Repair Kit 29250 2 Qty

38/ SS BALL STRAINER WASHER 27585 275435 27597 276806 OVERLOAD SPRING 5/6 SS BALL 20320 SCREEN RETAINER 220096 2243 Repair Kit 29250 2 Qty