SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

CALIBRATION CERTIFICATE # 500

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

KENYA ACCREDITATION SERVICE

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ENGINEERING TECHNICAL REPORT

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Recommended Practices for Calibration Laboratories

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

DFX II Series. Digital Force Gauge

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF MASS METROLOGY

Gas mixtures. Individual solutions specifically for your application

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

FPG8601 Force Balanced Piston Gauge

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

GMC-I Service GmbH Calibration Center

General Accreditation Guidance. User checks and maintenance of laboratory balances

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

Precision pressure sensor Basic version Model CPT6020

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

B ADDENDUM # 1

Inspection and Acceptance of Asphalt Mix Design Laboratories

Pressure is our Business

2014 Programme of Training Courses in Measurement & Calibration

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

Pneumatic High-Speed Pressure Controller Model CPC3000

EN ISO/IEC Technical Requirements

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

MET-101 Introduction to Metrology

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Inspection and Approval of Asphalt Mix Design Laboratories

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

High-speed pressure sensor Model CPT6140

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

It s not like other pressure gauges

Low Profile Load Cells

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

Calibrating a Micropipette

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

Technical Information Conducal CLY421

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

OXFORD CALIBRATION WEIGHTS CLASS E1, E2, F1

JCSS accredited laboratory Endress+Hauser Japan

How to evaluate pressure measurement specifications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

H&D Fitzgerald Pressure Pyknometry System Mark 5

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SOUTH AFRICAN NATIONAL STANDARD

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

User-Calibration of Mettler AT200 Analytical Balance

Procedia Engineering Procedia Engineering 2 (2010)

Accreditation for In-Service Inspection of Pressure Systems/Equipment

Gas Flow Calibration Basics

TESTING BENCHES for watermeters

Pressure calibration equipment

STANDARD OPERATING PROCEDURE FORCE DIAL FDN 100

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Speciality Gases Practice 4. Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel.

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Eclipse Precision & Analytical Balances

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ACME SCALE COMPANY 1801 Adams Ave San Leandro, CA 94577 Barbara Byrd Phone: 510 638 5040 CALIBRATION Valid To: August 31, 2019 Certificate Number: 3461.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Dimensional Parameter/Equipment Range CMC 2, 5 (±) Comments Linear Measurement 1D 3, 5 (0.25 to 6) in 0.0012 in + 0.060 % Caliper (6 to 24) in 0.028 in + 0.061 % Steel rule II. Mechanical Parameter/Equipment Range CMC 2 (±) Comments Balances Class I and High Precision Scales 3 0.01 mg Res. 0.01 mg Res. 0.1 mg Res. 1 mg Res. 2 mg Res. 5 mg Res. 1 mg to 50 g 1 mg to 0.2 kg 1 mg to 0.6 kg 1 mg to 1 kg 2 mg to 2 kg 5 mg to 5 kg 0.042 mg 0.090 mg 0.15 mg 0.88 mg 1.8 mg 4.4 mg weights and NIST Handbook 44 (A2LA Cert. No. 3461.01) 08/10/2017 Page 1 of 6

Balances Class I and High Precision Scales 3 (cont) 10 mg Res. 20 mg Res. 50 mg Res. 100 mg Res. 10 mg to 10 kg 20 mg to 20 kg 50 mg to 50 kg 100 mg to 100 kg 8.8 mg 18 mg 44 mg 88 mg weights and NIST Handbook 44 Balances Class II High Precision Scales 3 10 mg Res. 20 mg Res. 50 mg Res. 100 mg Res. 200 mg Res. 500 mg Res. 1000 mg Res. 2000 mg Res. 5000 mg Res. 10 000 mg Res. 10 mg to 1 kg 20 mg to 2 kg 50 mg to 5 kg 100 mg to 10 kg 200 mg to 20 kg 500 mg to 50 kg 1 g to 100 kg 2 g to 100 kg 5 g to 100 kg 10 g to 100 kg 0.0083 g 0.017 g 0.041 g 0.083 g 0.17 g 0.41 g 0.83 g 1.6 g 4.1 g 8.2 g and Class 2 weights and NIST Handbook 44 Scales High Res. Unmarked 3 0.000 02 lb Res. 0.000 05 lb Res. 0.0001 lb Res. 0.0002 lb Res. 0.0005 lb Res. 0.001 lb Res. 0.002 lb Res. 0.005 lb Res. 0.01 lb Res. 0.02 lb Res. 0.05 lb Res. 0.1 lb Res. 0.2 lb Res. 0.5 lb Res. 1 lb Res. (0.000 02 to 6) lb (0.000 05 to 15) lb (0.0001 to 30) lb (0.0002 to 60) lb (0.0005 to 150) lb (0.001 to 300) lb (0.002 to 600) lb (0.005 to 1000) lb (0.01 to 2000) lb (0.02 to 3000) lb (0.05 to 5000) lb (0.1 to 10 000) lb (0.2 to 20 000) lb (0.5 to 50 000) lb (1.0 to 100 000) lb 0.000 12 lb 0.000 22 lb 0.000 31 lb 0.000 65 lb 0.0014 lb 0.0021 lb 0.0063 lb 0.0094 lb 0.015 lb 0.022 lb 0.045 lb 0.087 lb 0.24 lb 0.49 lb 0.91 lb NIST Class F weights and NIST Handbook 44 (A2LA Cert. No. 3461.01) 08/10/2017 Page 2 of 6

Scales Industrial 3, 4 0.0002 lb Res. 0.0005 lb Res. 0.001 lb Res. 0.002 lb Res. 0.005 lb Res. 0.01 lb Res. 0.02 lb Res. 0.05 lb Res. 0.1 lb Res. 0.2 lb Res. 0.5 lb Res. 1.0 lb Res. 2.0 lb Res. 5.0 lb Res. 10.0 lb Res. 10.0 lb Res. 20.0 lb Res. 20.0 lb Res. (0.0002 to 3) lb (0.0005 to 7.5) lb (0.001 to 15) lb (0.002 to 30) lb (0.005 to 75) lb (0.01 to 150) lb (0.02 to 300) lb (0.05 to 750) lb (0.1 to 1500) lb (0.2 to 3000) lb (0.5 to 5000) lb (1.0 to 10 000) lb (2.0 to 20 000) lb (5.0 to 60 000) lb (10.0 to 50 000) lb (10.0 to 100 000) lb (20.0 to 100 000) lb (20.0 to 200 000) lb 0.000 18 lb 0.000 43 lb 0.000 85 lb 0.0017 lb 0.0042 lb 0.0084 lb 0.017 lb 0.042 lb 0.083 lb 0.17 lb 0.41 lb 0.83 lb 1.7 lb 4.1 lb 8.3 lb 13 lb 17 lb 26 lb NIST Class F weights and NIST Handbook 44 Weights Metric Class F 1 g 2 g 3 g 5 g 10 g 20 g 30 g 50 g 100 g 200 g 300 g 500 g 1 kg 2 kg 3 kg 4 kg 5 kg 10 kg 20 kg 25 kg 30 kg 0.27 mg 0.27 mg 0.29 mg 0.40mg 33 mg 33 mg 34 mg 35 mg 0.19 g weights and AP210s balance and GT 480 balance and PR5002 balance and SM 34K balance (A2LA Cert. No. 3461.01) 08/10/2017 Page 3 of 6

Weights Avoirdupois Class F 1 oz (28.34952 g) 2 oz (56.69904 g) 4 oz (113.39808 g) 8 oz (226.79616 g) 0.05 lb (0.0226796185 kg) 0.1 lb (0.045359237 kg) 0.2 lb (0.090718474 kg) 0.3 lb (0.136077711 kg) 0.5 lb (0.226796185 kg) 1 lb (0.45359237 kg) 2 lb (0.90718474 kg) 3 lb (1.36077711kg) 5 lb (2.26796185 kg) 10 lb (4.5359237 kg) 20 lb (9.0718474 kg) 25 lb (11.33980925 kg) 50 lb (22.6796185 kg) 1.1 mg 0.32 mg 0.45 mg 1.3 mg 0.55 mg 1.0 mg 1.5 mg 2.3 mg 33 mg 34 mg 0.19 g ASTM E617 Class 1 weights Force Measure with Weights 3 Tension and Compression (0.0005 to 0.0625) lbf Res. (0.0001 to 0.625) lbf Res. (0.0002 to 0.625) lbf Res. (0.0005 to 1.0) lbf Res. (0.001 to 5) lbf Res. (0.002 to 5) lbf Res. (0.005 to 5) lbf Res. (0.01 to 10) lbf Res. (0.01 to 10) lbf Res. (0.05 to 20) lbf Res. (0.1 to 50) lbf Res. (0 to 5) lbf (0 to 10) lbf (0 to 20) lbf (0 to 50) lbf (0 to 100) lbf (0 to 200) lbf (0 to 500) lbf (0 to 1000) lbf (0 to 2000) lbf (0 to 5000) lbf (0 to 10 000) lbf 0.000 069 lbf 0.000 14 lbf 0.000 23 lbf 0.000 59 lbf 0.0010 lbf 0.0019 lbf 0.0051 lbf 0.011 lbf 0.019 lbf 0.063 lbf 0.12 lbf ASTM E617 Class 6 weights NIST Class F weights (A2LA Cert. No. 3461.01) 08/10/2017 Page 4 of 6

Force Measure with Calibrated Load Cells 3 Tension and Compression (0.001 to 0.01) N Res. (0.01 to 0.1) N Res. (0.01 to 0.1) N Res. (1 to 10) N Res. (1 to 10) N Res. (10 to 100) N Res. (10 to 100) N Res. (100) N Res. (50 to 100) N (50 to 100) N (100 to 1000) N (50 to 100) N (100 to 1000) N (1000 to 2000) N (2000 to 5000) N (50 to 1000) N (1000 to 5000) N (50 to 1000) N (1000 to 5000) N (1000 to 5000) N 0.029 N 0.030 N 0.046 N 0.092 N 0.098 N 0.41 N 0.81 N 0.96 N 1.2 N 8.7 N 9.0 N 87 N Calibrated load cells III. Time and Frequency Parameter/Equipment Range CMC 2 (±) Comments Elapsed Time 3 (1 to 60) seconds (61 to 600) seconds 0.80 seconds 4.9 seconds Stopwatch 1 This laboratory offers commercial calibration and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) uncertainty is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC uncertainty found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. Res.) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC uncertainty. 4 Industrial Scales include Bench Scales, Counting Scales, Portable Scales, Floor Scales, Crane/Hanging Scales, Tank and Hopper Scales, Forklift/Lift Truck Scales and Force Measurement Gauges and Test Stands. (A2LA Cert. No. 3461.01) 08/10/2017 Page 5 of 6

5 In the statement of CMC, percentages are expressed as a percent of the total distance of the given distance test. (A2LA Cert. No. 3461.01) 08/10/2017 Page 6 of 6

Accredited Laboratory A2LA has accredited ACME SCALE COMPANY San Leandro, CA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets ANSI/NCSL Z540-1-1994 and R205 Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 10 th day of August 2017. President and CEO For the Accreditation Council Certificate Number 3461.01 Valid to August 31, 2019 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.