GAS PRESSURE REGULATORS AND FILTERS.

Similar documents
Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.

Service and installation must be performed by a trained/experienced service technician.

CATALOG. 2 nd Edition

Service and installation must be performed by a trained/experienced service technician.

Gas Pressure Regulators. 3rd Edition

210 & 220 series gas pressure regulators for industrial applications

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

GM-7000 Series CE Approved Gas Control Valve

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

OPERATING INSTRUCTIONS

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

GM Series Dual-Block Multi-Function Gas Control Valves

Ratio Regulator Zero Governor. FRG/6 Series

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Standard & Braided Gas Hoses, Safety Options & Regulators

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Old documentation - Only for your information! Product is not available anymore!

G96 Series BASOTROL Dual Operator Valve

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

GM-7000 Series CE Approved Gas Control Valve

Gas Pressure Regulator HON 300

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Safety Shut-off Valve SSV

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Valves for Biogases and Recycling Gases

Gas Pressure Regulator HON 200

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Double gas valves for biogases and recycling gases

RR 16 Commercial & Industrial Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

RR 16 Commercial & Industrial Regulator

627 Series Pressure Reducing Regulators

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Double valves for biogases and recycling gases

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Gas Pressure Regulator R 51

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Dual Solenoid Gas Valve Installation

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

safety Shut-Off Valve HON 721

Commonwealth of Massachusetts Approved Product Approval code G

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

V43 Pressure Actuated Water Regulating Valve

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

BGA158 Series CE Approved Class B Shutoff Gas Valve

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

BGC258 Series BASOTROL Gas Valve

Fuel Filters DN15 DN25. elektrogas.com DE

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

VR46.5V(A)/VR86.5V(A) SERIES

BGA158 Series CE Approved Class A Shutoff Gas Valve

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Seated valves VRB 3, VRG 3

Pressure reducing valves Index

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

North American Orifice Metering System

Performance Literature for J78. Gas Pressure Regulators ½, ¾ and 1 Sizes. Catalogue

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

AVP-F. p setting range (bar) Code No. 003H6200

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Pressure ranges and accuracy classes for outlet pressure and safety devices

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Valve Proving System VDK 200 A S02

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Gas Pressure Regulator HON 270 MK2

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Certified LP/Propane Line Pressure Regulator Guidebook

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Valve Proving System VDK 200 A S06*

Safety shut-off valve S 50. Product information

Gas Pressure Regulator HON 505

PRESSURE REDUCING VALVE RP45 (EN)

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Transcription:

GAS PRESSURE REGULATORS AND FILTERS R www.mertikmaxitrol.com

WARNING Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions of the Original Equipment Manufacturer (OEM) and with all applicable government codes and regulations, e.g. plumbing, mechanical, and electrical codes and practices. Maxitrol products should be installed and operated in accordance with Maxitrol Safety Warning Instructions. Maxitrol is NOT responsible for any errors or omissions in reliance by anyone of any information set forth in this catalog without additional reference to local requirements and applicable ordinances or codes. The products in this catalogue comply with EU legislation. The technical specifications refer to the CE certification. Additional international approvals and certifications are available upon request. B 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

CONTENT DRAFT 09.18.2013 GAS PRESSURE REGULATORS RV Series Rubber Seat Poppet Design... 2 RV Series Straight-Thru-Flow Design... 4 325 Series Appliance Regulators Lever Acting Design...6 RS Series Appliance Regulators Balanced Valve Design...8 210 Series Appliance Regulators Balanced Valve Design... 10 RZ and 210Z Series Appliance Regulators Zero Pressure Regulator Design...12 SPRING SELECTION Spring Selection Chart...15 ACCESSORIES Vent Limiting Device:... 16 Pressure Tap Connector... 16 Dust Cap... 16 Tamper Proof Seals... 16 SIZING A REGULATOR System Requirements... 17 FLOW CHARTS GAS PRESSURE REGULATORS RV Series Rubber Seat Poppet Design... 18 RV Series Straight-Thru-Flow Design... 19 325 Series Appliance Regulators Lever Acting Design... 20 RS/RZ Series Appliance Regulators Balanced Valve and Zero Pressure Regulator Design...21 210/210Z Series Appliance Regulators Balanced Valve and Zero Pressure Regulator Design...22 DEFINITIONS Definitions... 23 GAS & AIR FILTERS HF2000 Series... 24 GF1000 Series... 26 FLOW CHARTS GAS & AIR FILTERS HF2000 Series...28 GF1000 Series... 29 1

GAS PRESSURE REGULATORS RV SERIES RUBBER SEAT POPPET DESIGN The compact RV poppet regulators are designed primarily for main burner and pilot load applications. Typical applications include residential and commercial cooking appliances, barbecues, hearth products, and pilot lines. Maxitrol rubber seat poppet models offer the ultimate in design features and performance capabilities to meet your specific appliance or utility requirements. Specifications Pipe Sizes: Rp ⅛" to Rp ¾" threaded connections according to ISO 7-1/EN10226-1 Housing Material: Aluminum Internal Components Material: Steel, aluminum, elastomer Mounting: Suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: 10 kpa Ambient Temperature Range: -15 C to 80 C Capacities: See flow chart, page 18 Model Designations Models having a suffix letter or a combination of suffix letters listed below indicates the design modifications described. C... Convertible regulators*; preset to deliver outlet pressures for either natural or LP gases (RV20, RV47, RV48). L... Integral vent limiting orifice as the breather hole with dust cap. M... Rp parallel thread conforms to ISO 7-1/EN10226-1, where pressure tight joints are made on the threads. SR... Side pressure tap; right side** Rp ⅛" (RV20, RV47, RV48). S... Side pressure tap; left side** Rp ⅛" (RV20, RV47, RV48). V... Threaded vent connector, 5/16-24 for Rp ⅛" tubing connection (RV20) with dust cap. * Convertible regulators are designed to deliver either of two fixed outlet pressures for natural or LP gases. RV20C: 1.0 kpa (NG); 2.5 kpa (LP) RV47C, RV48C: 1.0 or 1.25 or 1.5 kpa (NG); 2.5 or 2.75 kpa (LP) ** Left and right is determined when viewing regulator from outlet side with stack up. 2 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS DRAFT 09.18.2013 Dimensions Model Pipe Sizes Swing Radius Dimensions A B C D RV12 Rp ⅛" 35 mm 43 mm 10 mm 43 mm 35 mm RV20 Rp ¼", Rp ⅜" 41 mm 54 mm 13 mm 61 mm 45 mm RV47 Rp ⅜", Rp ½" 48 mm 64 mm 16 mm 75 mm 57 mm RV48 Rp ½", Rp ¾" 51 mm 70 mm 19 mm 86 mm 76 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. RV48 D RV12 RV20 A B C RV47 RV48 Components 1 2 NOTE: Diagrams are graphical representations only and may differ from actual product. 8 3 4 9 10 5 6 7 11 12 13 1 Seal Cap 2 Seal Cap Gasket 3 Adjusting Screw 4 Spring 5 Top Housing 6 Diaphragm 7 Stem & Valve 8 Stack 9 Dust Cap 10 Vent 11 Diaphragm Plate 12 Rubber Seat 13 Bottom Housing 3

GAS PRESSURE REGULATORS RV SERIES STRAIGHT-THRU-FLOW DESIGN Maxitrol s original straight-thru-flow (STF) design regulators are non-lockup type regulators for high capacities at low inlet pressures. The difference between STF design and other type regulators is the conical valve. The cone principal permits gas to flow straight through the regulator without changing directions. Frictional flow resistance is reduced, resulting in greater capacity. An improved flow pattern provides accurate, sensitive regulation at extremely low pressure differentials. Typical applications include residential, commercial, and industrial gas-fired appliances and equipment used on low or medium pressure gas supplies. Specifications Pipe Sizes: - RV52, RV53, RV61, RV81, RV91, RV111: Rp ½" to Rp 3" threaded connections according to ISO 7-1/ EN10226-1 - RV131: DN100 flanged connection according to ISO 7005-2 PN 16 Housing Material: - RV52, RV53, RV61, RV81, RV91, RV111: Aluminum - RV131: Cast iron Internal Components Material: Steel, aluminum, elastomer Mounting: RV52, RV53, RV61 are suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. If ball check vent limiting device is installed, mount in an upright position only. RV81, RV91, RV111, RV131 upright position only. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: - RV52: 10 kpa - RV53, RV61, RV81, RV91, RV111: 20 kpa - RV131: 35kPa Ambient Temperature Range: -15 C to 80 C Capacities: See flow chart, page 19 Dimensions 4 Model Pipe Sizes Swing Radius Dimensions A B C D RV52 Rp ½", Rp ¾" 91 mm 124 mm 32 mm 83 mm 81 mm RV53 Rp ¾", Rp 1" 99 mm 132 mm 33 mm 99 mm 95 mm RV61 Rp 1", Rp 1 ¼" 122 mm 164 mm 41 mm 138 mm 111 mm RV81 Rp 1 ¼", Rp 1 ½" 162 mm 213 mm 51 mm 178 mm 153 mm RV91 Rp 2" 216 mm 275 mm 60 mm 232 mm 165 mm Rp 2 ½" 212 mm 267 mm 62 mm 232 mm 181 mm RV111 Rp 2 ½", Rp 3" 284 mm 373 mm 89 mm 324 mm 229 mm RV131 DN100 462 mm 574 mm 120 mm 457 mm 350 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS DRAFT 09.18.2013 RV52, RV53 RV61 D A C B RV81, RV91 RV111 RV131 Components 1 2 7 NOTE: Diagrams are graphical representations only and may differ from actual product. 8 9 10 3 4 5 6 11 12 13 14 1 Welch Plug/Seal Cap 2 Vibration Resistant Adjusting Screw 3 Top Housing 4 Diaphragm 5 Stem 6 Bottom Housing 7 Seal Cap Gasket 8 Stack 9 Spring 10 Vent Limiting Device 11 Diaphragm Plates 12 Valve 13 Bottom Plate Gasket 14 Bottom Plate 5

GAS PRESSURE REGULATORS 325 SERIES LEVER ACTING DESIGN Maxitrol s 325 Series regulators are for use on residential, commercial, and industrial applications. The 325 Series features a high leverage valve linkage assembly to deliver a lockup characteristic. The regulators are capable of precise control from full flow down to pilot flow. Specifications Pipe Sizes: Rp ⅜" to Rp 2" threaded connections according to ISO 7-1/EN10226-1 Housing Material: Aluminum Internal Components Material: Steel, aluminum, brass, elastomer Mounting: Suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. If ball check vent limiting device is installed, mount in an upright position only. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: 100 kpa Ambient Temperature Range: -15 C to 80 C Capacities: See flow chart, page 20 NOTE: Certifications for 325-9 and 325-11 models pending. Dimensions Model Pipe Size Swing Radius Dimensions A C D 325-3 Rp ⅜", Rp ½" 76 mm 89 mm 108 mm 98 mm 325-5 Rp ½", Rp ¾", Rp 1" 124 mm 133 mm 149 mm 138 mm 325-7 Rp 1 ¼", Rp 1 ½" 156 mm 184 mm 203 mm 178 mm 325-9 Rp 1 ½", Rp 2" 198 mm 239 mm 274 mm 231 mm 325-11 Rp 2", Rp 2 ½" 297 mm 333 mm 409 mm 343 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. 6 325-3 325-5 325-7 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS DRAFT 09.18.2013 D A C 325-9 325-11 Components 1 2 6 7 NOTE: Diagrams are graphical representations only and may differ from actual product. 3 4 5 8 9 10 11 12 1 Seal Cap 2 Stack 3 Top Housing 4 Rubber Valve 5 Valve Seat 6 Seal Cap Gasket 7 Adjusting Screw 8 Vent Limiting Device 9 Spring 10 Diaphragm 11 Diaphragm Plates 12 Bottom Housing 7

GAS PRESSURE REGULATORS RS SERIES BALANCED VALVE DESIGN The R & RS Series double diaphragm balanced valve design makes it possible to maintain steady outlet pressure control with widely varying inlet pressures. The regulator is physically small yet has exceptional capacity characteristics. R & RS Series regulators are intended for use with both main burner and pilot load applications. They are ideally suited for use with infrared heaters and pilot lines on large industrial heaters and boilers. Specifications Pipe Sizes: Rp ⅜" to Rp 1" threaded connections according to ISO 7-1/EN10226-1 Housing Material: Aluminum Internal Components Material: Steel, aluminum, brass, elastomer Mounting: Suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. If ball check vent limiting device is installed, mount in an upright position only. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: 36 kpa Ambient Temperature Range: -15 C to 80 C Capacities: See flow chart, page 21 Dimensions Model Pipe Sizes Swing Radius Dimensions A B C D R400S Rp ⅜", Rp ½" 60 mm 83 mm 24 mm 51 mm 51 mm R500S Rp ½", Rp ¾" 90 mm 119 mm 30 mm 79 mm 76 mm R600S Rp ¾", Rp 1" 110 mm 145 mm 38 mm 99 mm 103 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. 8 A B R400S C D R500S, R600S 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS Components DRAFT 09.18.2013 1 2 7 8 NOTE: Diagrams are graphical representations only and may differ from actual product. 9 10 3 4 5 6 11 12 13 1 Welch Plug/Seal Cap 2 Vibration Resistant Adjusting Screw 3 Top Housing 4 Regulating Diaphragm 5 Stem & Valve 6 Bottom Housing 7 Seal Cap Gasket 8 Stack 9 Spring 10 Vent Limiting Device 11 Balancing Diaphragm 12 Bottom Plate Gasket 13 Bottom Plate 9

GAS PRESSURE REGULATORS 210 SERIES BALANCED VALVE DESIGN The 210 Series is a lockup characteristic regulator. Its balanced valve design makes it possible to maintain steady outlet pressure control with widely varying inlet pressures. The regulator has an integrated dampening mechanism in the breather outlet and the sensing tube to improve regulating stability and reduce hunting tendencies. The 210 Series provides precise regulation over a wide range of pressures and flow rates. Applications include gas-fired boilers, steam generators, industrial furnaces, and ovens. Specifications Pipe Sizes: - 210D, 210E, 210G: Rp 1" to Rp 3" threaded connections according to ISO 7-1/EN10226-1 - 210J: DN100 flanged connections according to ISO 7005-2, PN 16 Housing Material: - 210D, 210E, 210G: Aluminum - 210J: Cast iron Internal Components Material: Steel, aluminum, brass, elastomer Mounting: Suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. If ball check vent limiting device is installed, mount in an upright position only. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: 85 kpa Ambient Temperature Range: -15 C to 80 C Capacities: See flow chart, page 22 10 Dimensions Swing Dimensions Model Pipe Size Radius A B C D 210D Rp 1", Rp 1 ¼", Rp 1 ½" 138 mm 228 mm 60 mm 152 mm 178 mm 210E Rp 1 ½", Rp 2" 211 mm 286 mm 75 mm 203 mm 232 mm 210G Rp 2 ½", Rp 3" 302 mm 419 mm 116 mm 300 mm 343 mm 210J DN100 467 mm 616 mm 138 mm 349 mm 457 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS DRAFT 09.18.2013 D A B C 210D, 210E, 210G 210J Components 1 7 NOTE: Diagrams are graphical representations only and may differ from actual product. 2 8 9 10 3 4 5 6 11 12 13 14 15 1 Welch Plug/Seal Cap 2 Vibration Resistant Adjusting Screw 3 Top Housing 4 Regulating Diaphragm 5 Stem & Valve 6 Bottom Housing 7 Seal Cap Gasket 8 Stack 9 Spring 10 Vent Limiting Device 11 Diaphragm Plates 12 Balancing Diaphragm 13 Sensing Tube 14 Bottom Plate Gasket 15 Bottom Plate 11

GAS PRESSURE REGULATORS RZ AND 210Z ZERO PRESSURE REGULATOR DESIGN The RZ and 210Z Series are adaptable for air-gas mixing applications. Because of the balanced valve construction, Z-models offer superior performance at an economical price compared with other types of atmospheric regulators. Maxitrol s RZ and 210Z Zero Pressure Regulator models are used for flow control of burners, nozzle mixers, mixing tees and proportional premixers. Specifications Pipe Sizes: - R400Z, R500Z, R600Z: ⅜" to 1" threaded connections according to ISO 7-1/EN10226-1 - 210DZ, 210EZ, 210GZ: 1" to 3" threaded connections according to ISO 7-1/EN10226-1 - 210JZ: DN100 flanged connections according to ISO 7005-2, PN 16 Housing Material: Aluminum Internal Components Material: - R400Z, R500Z, R600Z: Steel, aluminum, brass, elastomer - 210DZ, 210EZ, 210GZ: Aluminum - 210JZ: Aluminum, cast iron Mounting: R400Z, R500Z, R600Z are suitable for multi-positional mounting. Other than upright position will result in a slight difference in outlet pressure. If ball check vent limiting device is installed, mount in an upright position only. 210DZ, 210EZ, 210GZ, 210JZ mount in upright position only. Install with gas flowing as indicated by the arrow on bottom casting. Construction and Design/Certifications: According to EN88 and Gas Appliances Directive 2009/142/EC Gas Types: Suitable for gases of EN 437 gas family 1, 2, and 3 Maximum Inlet Pressure: - R400Z, R500Z, R600Z: 10 kpa - 210DZ, 210EZ, 210GZ, 210JZ: 36 kpa Ambient Temperature Range: -15 C to 80 C Capacities: See flow charts, page 21 and 22 Dimensions 12 Model Pipe Sizes Swing Radius Dimensions A B C D R400Z Rp ⅜", Rp ½" 60 mm 83 mm 24 mm 51 mm 51 mm R500Z Rp ½", Rp ¾" 90 mm 119 mm 30 mm 79 mm 79 mm R600Z Rp ¾", Rp 1" 109 mm 144 mm 37 mm 102 mm 98 mm 210DZ Rp 1", Rp 1 ¼", Rp 1 ½" 138 mm 229 mm 60 mm 152 mm 178 mm 210EZ Rp 1 ½", Rp 2" 211 mm 286 mm 75 mm 203 mm 232 mm 210GZ Rp 2 ½", Rp 3" 302 mm 419 mm 116 mm 300 mm 343 mm 210JZ DN100 467 mm 616 mm 138 mm 349 mm 457 mm NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the regulator. Actual production dimensions may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS PRESSURE REGULATORS DRAFT 09.18.2013 D A R400Z, R500Z, R600Z B C 210DZ, 210EZ, 210GZ 210JZ Components R400Z, R500Z, R600Z 1 7 NOTE: Diagrams are graphical representations only and may differ from actual product. 2 8 9 10 3 4 5 6 11 12 13 1 Seal Cap 2 Adjusting Screw 3 Top Housing 4 Regulating Diaphragm 5 Stem & Valve 6 Bottom Housing 7 Seal Cap Gasket 8 Stack 9 Spring 10 Vent Connection 11 Balancing Diaphragm 12 Counter Spring 13 Bottom Plate 13

GAS PRESSURE REGULATORS Components 210DZ, 210EZ, 210GZ, 210JZ 1 2 7 8 NOTE: Diagrams are graphical representations only and may differ from actual product. 9 10 3 4 5 6 11 12 13 14 15 1 Seal Cap 2 Adjusting Screw 3 Top Housing 4 Regulating Diaphragm 5 Stem & Valve 6 Bottom Housing 7 Seal Cap Gasket 8 Stack 9 Spring 10 Vent Connection 11 Diaphragm Plates 12 Balancing Diaphragm 13 Sensing Tube 14 Counter Spring 15 Bottom Plate 14 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

SPRING SELECTION SPRING SELECTION DRAFT 09.18.2013 Spring Code A B C D E F G H K L M N Outlet Pressure Range (kpa) Model Spring Replacement Number 0.25 0.90 0.50 1.25 0.50 1.50 0.70 1.30 0.75 2.00 1.00 2.00 1.00 3.00 1.25 3.00 2.50 5.50 3.75 7.50 5.00 10.50 7.00 14.00 Color brown (plated) green (plated) pink orange violet blue red yellow black label RV12 KIT...-R1210 X X X X RV20 KIT...-R2010 X X X X RV47 KIT...-R4710 X X X X RV48 KIT...-R4810 X X X X RV52 KIT...-R5210 X X X X X RV53 KIT...-R5310 X X X X X X RV61 KIT...-R6110 X X X X X X RV81 KIT...-R8110 X X X X X X X RV91 KIT...-R9110 X X X X X X X RV111 KIT...-R11110 X X X X X X X RV131 KIT...-R13110 X X X X X X 325-3 KIT...-R325C10 X X X X X 325-5 KIT...-R325E10 X X X X X 325-7 KIT...-R8110 X X X X X X X 325-9 KIT...-R9110 X X X X X X X 325-11 KIT...-R11110 X X X X X X X R400S KIT...-R400B10 X X X X X R500S KIT...-R5210 X X X X X R600S KIT...-R5310 X X X X X X 210D KIT...-R8110 X X X X X X X 210E KIT...-R9110 X X X X X X X 210G KIT...-R11110 X X X X X X X 210J KIT...-R13110 X X X X X X NOTE: No spring replacement required for zero pressure regulator models 15

ACCESSORIES ACCESSORIES The following items are not sold separately and must be ordered with gas pressure regulators. Vent Limiting Device: 12A04/ 12A09 12A39 Maxitrol vent limiting devices eliminate the need to run vent piping to the outside. Vent limiting devices are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiting devices should not be used outdoors if they are exposed to the environment. Optional automatic vent limiting device ball check permits unobstructed inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to be within EN 88 requirements should a diaphragm rupture: 12A04: Use on RV52, RV53, RV61, R400S, R500S and R600S regulators 12A09: Use on 325-3 regulators 12A39: Use on RV81, RV91, RV111, 325-5, 325-7 and 210 Series regulators NOTE: When using the vent limiting device, the regulator must be mounted in a horizontal upright position. NOTE: If no vent limiting device is used, regulator vent must be piped in accordance with government and local codes and regulations. Pressure Tap Connector PF10: Pressure tap connector installed as part of the control. It is a hose fitting incorporating a captured sealing means for testing inlet and outlet pressures. This eliminates the need for a special barb fitting. PF10 Dust Cap Use on vent opening to prevent blockage of breather hole from dust or other foreign particles. Standard on all L models with ⅛" threaded vent. 13A09: For Rp ⅛" vent. Press-in plastic cap 13A09 Tamper Proof Seals 101310 Permanent pressure sensitive backed paper. Attempted removal of these seals will destroy the face stock, leaving adhesive residue on surface beneath. Therefore, tampering can be easily detected. Available for all threaded models. Outlet pressure printed on seal. 101310: For RV12, RV20L, RV47, RV48, RV52, RV53, RV61, R400S(Z), RV500S(Z), R600S(Z), 325-3, and 325-5 101311: For RV81, RV91, RV111, 210D, 210E, 210G, 325-7 16 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

SIZING A REGULATOR SIZING A REGULATOR System Requirements DRAFT 09.18.2013 When sizing a regulator the following must be known: Gas Type Available Inlet Pressure Desired Outlet Pressure Zero Pressure Regulator Application (indicated by model number ending in Z ) Will the regulator control main burner and pilot load OR main burner only? Required minimum and maximum flow rate in m 3 /h or kw Pipe Size In most cases, the manifold pipe size has already been selected on the basis of good engineering practice, and the regulator pipe size should conform to this size. The capacity of any regulator is not an absolute value but will vary with the application depending on the prevailing differential pressure. HOW TO DETERMINE THE SUITABLE REGULATOR FROM THE FLOW CHART Draw a horizontal line with the known differential pressure (inlet pressure minus outlet pressure). Next draw a vertical line with the required flow rate (take care to use the axis with the correct gas type). The regulator where both lines cross each other within the range of regulation is the suitable regulator. Pressure Differential Δp Regulator is NOT suitable Regulator is suitable NOTE: See www.maxitrol.com for our Regulator Sizing Program. Please contact Maxitrol directly for more information on sizing a regulator. NOTE: Service and installation must be performed by a trained/ experienced service technician. Flow Rate Q (NG, LP or Air) LEGEND FOR FLOW CHARTS Δp = Pressure Differential in KPa Q = Flow Rate in m 3 /h dv = Volumetric Rate of Flow f = Friction Factor ρ = Density dv = ρ gas ρ air Pressure Units: 1 kpa = 10 mbar = 10 hpa Air: dv = 1.00 f = 1.00 Natural Gas (NG): dv = 0.64 f = 1.24 liquid petroleum gas (LPG): dv = 1.56 f = 0.80 V gas = f V air f = ρ air ρ gas 17

FLOW CHARTS GAS PRESSURE REGULATORS FLOW CHARTS GAS PRESSURE REGULATORS RV Series Rubber Seat Poppet Design Pressure Differential Δp kpa Flow Rate Q (Air) m³/h 18 Flow Rate Q (NG) m³/h Flow Rate Q (LPG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

FLOW CHARTS GAS PRESSURE REGULATORS DRAFT 09.18.2013 RV Series Straight-Thru-Flow Design Pressure Differential Δp kpa Flow Rate Q (Air) m³/h Flow Rate Q (NG) m³/h Flow Rate Q (LPG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 19

FLOW CHARTS GAS PRESSURE REGULATORS 325 Series Appliance Regulators Lever Acting Design Pressure Differential Δp kpa Flow Rate Q (Air) m³/h 20 Flow Rate Q (NG) m³/h Flow Rate Q (LPG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

FLOW CHARTS GAS PRESSURE REGULATORS DRAFT 09.18.2013 RS/RZ Series Appliance Regulators Balanced Valve and Zero Pressure Regulator Design Pressure Differential Δp kpa Flow Rate Q (Air) m³/h Flow Rate Q (NG) m³/h Flow Rate Q (LPG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 21

FLOW CHARTS GAS PRESSURE REGULATORS 210/210Z Series Appliance Regulators Balanced Valve and Zero Pressure Regulator Design Pressure Differential Δp kpa Flow Rate Q (Air) m³/h 22 Flow Rate Q (NG) m³/h Flow Rate Q (LPG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

DEFINITIONS DEFINITIONS DRAFT 09.18.2013 Capacity Total load Btu/h of all appliances combined. Lockup Characteristic Under no flow conditions, outlet pressure will rise above adjusted pressure but will not rise to line pressure. Maximum Capacity (Main Burner and Pilot) Maximum capacity of a pressure regulator at which the pressure regulator will control main burner and pilot line pressure within acceptable limits. Maximum Capacity (Main Burner Only) Maximum capacity of a pressure regulator at which the pressure regulator will control main burner pressure within acceptable limits. Maximum Individual Load Largest single appliance or burner served by the pressure regulator. Maximum Inlet Pressure The highest inlet pressure for which the control is intended to be used. Minimum Capacity (Main Burner Only) Minimum capacity of a pressure regulator designed to control the flow to the main burner only. Non-Lockup Type Under static conditions when no gas is flowing, outlet pressure will rise to line pressure. Pressure Differential The difference between inlet pressure to the pressure regulator and outlet pressure from the pressure regulator. To obtain differential pressure, subtract the desired outlet pressure from available inlet pressure. Pressure Drop The natural loss of pressure that occurs in the pressure regulator (or in any valve or pipe) due to friction. This friction impedes fluid motion, without regard to artificial losses deliberately created by diaphragm action. The equivalent flow rate for a loss in given pressure with the pressure regulator valve in a normally wide open position. Vent Limiter A means that limits the flow of gas from the atmospheric chamber to the atmosphere in the event of a diaphragm rupture. This may be either a limiting orifice or a ball check vent limiting device. Limiting Orifice Type: A vent limiter where the flow through the limiter is the same in both directions Gas/Air Ratio Regulators / Zero Pressure Regulators They require an external impulse signal, such as top loading with pressure or generating vacuum in the downstream piping. 23

GAS & AIR FILTERS HF2000 SERIES GAS & AIR FILTERS Gas and air filters protect downstream controls (regulators, automatic shut-off valves) from particulate contamination. Recommended for use upstream of fittings, regulators, and controls. Applications for the residential, commercial cooking, process heating, and industrial burner industries. Specifications Pipe Sizes: - Rp ½" to Rp 2" threaded connections according to EN 10226-1 / ISO 7-1 - DN25 to DN150 flanged connections according to ISO 7005-2, PN 16 Housing Material: Aluminum Internal Components Material: Aluminium, elastomer, polypropylene fleece, galvanized wire mesh Filter Insert: Particulate contamination that equals or exceeds 50 µm Mounting: Suitable for multi-positional mounting, preferably with lid facing down or to the side to facilitate removal of debris during maintenance. Construction and Design/Certifications: According to DIN 3386, Gas Appliances Directive 2009/142/EC and Pressure Equipment Directive 97/23/EEC Gas Types: Gas family 1, 2, and 3 according to EN 437 Maximum Inlet Pressure: 100 kpa, 400 kpa, 600 kpa Ambient Temperature Range: -20 to 80 C Pressure Tap Connector: Optional: Pressure tap (PF10) connections inlet and/or outlet side. Storage and Transport Temperature: -50 to 80 C Gas Filter Service Kit (incl. Insert, Gasket, and Screws) Filter Inserts Model GF40M-44 GF60M-66 GF60M-88 Service Kit Number Kit-GF40M Kit-GF60M Min. Order Quantity Filter Insert for Rp ½", ¾", 1" and DN 25 GF80M-1010 10 24 GF80M-1212 Kit-GF80M GF80M-1616 GF25MF-88 Kit-GF60M HF2000F80 Kit-GF80MF 5 HF2000F100 Kit-GF100MF 3 GF125MF-4040 Kit-GF125MF GF150MF-4848 Kit-GF150MF 2 Filter Insert for Rp 1 ¼", 1 ½", 2" and DN40 to DN150 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS & AIR FILTERS Dimensions DRAFT 09.18.2013 Model Connection Pipe Size GF40M-44 Space for filter mat replacement S Dimensions A B C D (flanged) Rp ½" 60 mm 53 mm 69 mm 58 mm - GF60M-66 Rp ¾" 100 mm 94 mm 110 mm 94 mm - GF60M-88 Rp 1" 100 mm 94 mm 110 mm 94 mm - Thread GF80M-1010 Rp 1 ¼" 150 mm 126 mm 157 mm 160 mm - GF80M-1212 Rp 1 ½" 150 mm 126 mm 157 mm 160 mm - GF80M-1616 Rp 2" 150 mm 126 mm 157 mm 160 mm - GF25MF-88 DN25 100 mm 115 mm 165 mm 115 mm 14 mm HF2000F80 DN80 200 mm 204 mm 284 mm 215 mm 18 mm HF2000F100 Flange DN100 220 mm 225 mm 339 mm 270 mm 18 mm GF125MF-4040 DN125 270 mm 268 mm 400 mm 323 mm 18 mm GF150MF-4848 DN150 310 mm 308 mm 448 mm 363 mm 22 mm GF40M GF60M GF80M S C D A B GF80MF, GF100MF, GF125MF, GF150MF NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the filter. Actual production dimensions may vary somewhat from those shown. 25

GAS & AIR FILTERS GF1000 SERIES GAS & AIR FILTERS Gas and air filters protect downstream controls (regulators, automatic shut-off valves) from particulate contamination. Recommended for use upstream of fittings, regulators, and controls. Applications for the residential, commercial cooking, process heating, and industrial burner industries. Specifications Pipe Sizes: DN40 to DN65 flanged connections according to ISO 7005-2, PN 16 Housing Material: Aluminum Internal Components Material: Aluminium, elastomer, polypropylene fleece, galvanized wire mesh Filter Insert: Particulate contamination that equals or exceeds 50 µm Mounting: Suitable for multi-positional mounting, preferably with lid facing down or to the side to facilitate removal of debris during maintenance. Construction and Design/Certifications: According to DIN 3386, Gas Appliances Directive 2009/142/EC and Pressure Equipment Directive 97/23/EEC Gas Types: Gas family 1, 2, and 3 according to EN 437 Pressure Tap Connector: Optional pressure tap (PF10) connections inlet and/or outlet side. Maximum Inlet Pressure: 100 kpa, 400 kpa, 600 kpa Ambient Temperature Range: -20 to 80 C Storage and Transport Temperature: -50 to 80 C Gas Filter Service Kit (incl. Insert, Gasket, and Screws) Filter Insert Model GF1000MF40 GF1000MF50 GF1000MF65 Service Kit Number KT-GF1000MF Min. Order Quantity Upon request Filter Insert 26 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

GAS & AIR FILTERS Dimensions DRAFT 09.18.2013 Model Connection Pipe Size GF1000MF40 Space for filter mat replacement S Dimensions A B C D DN40 150 mm 159 mm 230 mm 160 mm 18 mm GF1000MF50 Flange DN50 150 mm 168 mm 230 mm 160 mm 18 mm GF1000MF65 DN65 150 mm 185 mm 230 mm 160 mm 18 mm S C D A B GF1000MF40 GF1000MF50 GF1000MF65 NOTE: Dimensions are maximums and to be used only as an aid in designing clearance for the filter. Actual production dimensions may vary somewhat from those shown. 27

FLOW CHARTS GAS & AIR FILTERS FLOW CHARTS GAS & AIR FILTERS HF2000 Series Pressure Differential Δp kpa Flow Rate Q (Air) m 3 /h Flow Rate Q (NG) m³/h 28 LEGEND FOR FLOW CHARTS Δp = Pressure Differential in KPa Q = Flow Rate in m 3 /h dv = Volumetric Rate of Flow f = Friction Factor ρ = Density dv = ρ gas ρ air f = ρ gas Pressure Units: 1 kpa = 10 mbar = 10 hpa Air: dv = 1.00 f = 1.00 Natural Gas (NG): dv = 0.64 f = 1.24 liquid petroleum gas (LPG): dv = 1.56 f = 0.80 V gas = f V air ρ air NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.

FLOW CHARTS GAS & AIR FILTERS DRAFT 09.18.2013 GF1000 Series Pressure Differential Δp kpa Flow Rate Q (Air) m 3 /h Flow Rate Q (NG) m³/h NOTE: The given flow rates are approximate values. Actual flow rates may vary somewhat from those shown. 29

R 2017 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. Mertik Maxitrol GmbH & Co. KG Warnstedter Str. 3 06502 Thale Germany Tel: (+49) 3947 400-0 Fax: (+49) 3947 400-200 info@mertikmaxitrol.com www.mertikmaxitrol.com Mertik Maxitrol GmbH & Co. KG Industriestr. 1 48308 Senden Germany Tel: (+49) 2597 9632-0 Fax: (+49) 2597 9632-99 senden@mertikmaxitrol.com www.mertikmaxitrol.com Mertik Maxitrol GmbH & Co. KG The Valleys Innovation Centre Abercynon, South Wales CF45 4SN UK Direct: (+44) 1443 742-755 Mobile: (+44) 7866 492-261 info@mertikmaxitrol.com www.mertikmaxitrol.com EXCLUSIVE AGENT Maxitrol Company 23555 Telegraph Road P.O. Box 2230 Southfield, MI 48037-2230 USA Tel: (+1) 248 356-1400 Fax: (+1) 248 356-0829 info@maxitrol.com www.maxitrol.com GDR.GF-LT-EN-08.2017-rev