Fiber Optic Splice Closures

Similar documents
Technical Data Sheet. R&M Closures

Huiyuan Communication Technologies Co.,Ltd.

PRODUCT SPECIFICATION

463XGW Gel Wrap PST Dome Closure

Fibre Optic Closure 2179-CS

May08 Rev B

Rapidmain Installation Guide

Coiling Tube with Twist-Proof Fitting

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Key Comparison of Safety Requirements in Europe, North America and Australia for Electronic Products

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY, M-169A/AIC

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR

INSTRUCTION MANUAL Pressure Relief Device LPT

Installation and Operation Instruction Manual

CERTIFICATION OF COMPLIANCE OF THE USER S DESIGN SPECIFICATION

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

User Manual V14.1 IP68 LED FLEX NEON

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

TECH TIPS: ROPE DEFECTS

Installation and Operating Instructions for Automotive Winch Synthetic Rope

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Multi Core Tube for General Pneumatic Piping

An Urgent Bulletin from CSA Group

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

QUALIFICATION ENVIRONMENTS FOR AMP PROGRAM PROPELLANT TANK ALLIANT TECHSYSTEMS, P/N 80520

Pressure switches for air and water CS

CONTENTS 2/9 1.1 OEM7474R. Specification for Buzzer. 1. Scope. 2. General. 3. Maximum Rating. 4. Electrical Characteristics. 5.

Rocky Mountain Element Technical Manual. Rev B

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Push-In Fitting Type with Stop Valve

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Umbilicals Experience and Challenges, Tie Back installations

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

Guide for Evaluating Your Hose Assembly Supplier

FOR MORE INFORMATION CONTACT OUR NEAREST BRANCH OFFICE

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Powers Controls D Day-Night Thermostats

User s Guide. CO2 Controller for miniature incubators

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact DBI/SALA.

17J Third Edition, January 2008 Specification for Unbonded Flexible Pipe

Vibration isolation system 1VIS10W. User manual

6146XX-X OPEN STYLE HOSE REELS

Product Specification Spring Finger

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Speed Controller Anti-spatter Series

Underground irrigation

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Report of Hydraulic Brake Hose Testing

ASSE International Product (Seal) Listing Program

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

Verdi G-Series Family

Technical Data. General specifications. Rated operating distance s n 2 mm

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

Technical Data. General specifications. Rated operating distance s n 5 mm

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Installation Guideline for Placing Fiber Optic Cable into an Underground Duct

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

WELLS JOHNSON HIGH VOLUME CANISTERS

Made in the USA. For Fall Protection Only. SafeLok Part Description

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Pressure Gauge Series

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Pressure transmitters EMP 2

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Push-In Fitting Type Silencer

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

CAST IRON VALVES FLOAT VALVE

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Typical Strength of Glued Connection. Typical Strength of Screwed Connection

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Rock. ky Altit. ude. Rev B

Push-In Fitting Type Pressure Gauge

Tube for General Pneumatic Piping

Tube Cutter with Measuring tape built-in

Figure 1 - Parts Identification

Dual Solenoid Gas Valve Installation

Vertical and Horizontal Bladder Tanks

Suspension Ropes. Suspension Rope

Introduction INDEX. INTRODUCTION HSE

Transcription:

Fiber Optic Splice Closures

. Products Descriptions of Optical Closure and Splice Tray FOCSS FOCS FOCM Splice Tray-2C Splice Tray-24C Dimensions (mm): 225(l) 08(w) 2(h) Dimensions (mm): 68(l) 9(w) 9(h) 2

. Products Structure, Dimension and Weight Items Ports In-Let Cable Size (mm) Dimensions (l w h) Weight with box FOCSS 3 ports per each end Min. Φ8 ~ max.φ9 325 87 30, mm 3.9 kg 2-2 ports Min. Φ8 ~ max.φ29 FOCS 2-3 ports Min. Φ8 ~ max.φ29 450 87 30, mm 5.0 kg 3-3 ports Min. Φ8 ~ max.φ24 2-2 ports Min. Φ8 ~ max.φ29 FOCM 2-3 ports Min. Φ8 ~ max.φ29 450 87 66, mm 5.7 kg 3-3 ports Min. Φ8 ~ max.φ24 C B A Cutting Applicable exterior Point diameter, in (mm) A Φ0.35~Φ0.60 (Φ8~Φ5) B C Φ0.6~Φ0.87 ( ~Φ24) Φ0.88~Φ.06 ( ~Φ29) 3

. Products Capacity Items Max. Capacity Single Core 2-Core Ribbon 4-Core Ribbon 8-Core Ribbon FOCSS 48 core 48 core 80 core 28 core FOCS 72 core 72 core 44 core 92 core FOCM 44 core 44 core 288 core 384 core Splice Tray-2C 2 core 2 core 20 core 32 core Splice Tray-24C 24 core 24 core 40 core 64 core 4

. Products Components Descriptions FOCSS Quantity FOCS FOCM Housing Pair Pair Pair Side Gasket Pair Pair Pair End Gasket Pair Pair Pair Splice Tray User define Bracket Grounding Wire Pair Pair Pair Grounding terminal Bolt/Nut 5 8 8 Sealant/Vacuum Grease Option/0g Option/0g Option/0g Hose Clamp 2 EA 2 EA 2 EA Cable Ties 2 EA 2 EA 2 EA Protection tube 2 EA 6~2 EA 24 EA Air Check Valve Underground application Installation Manual 5

2. Specifications Requirements of closures Properties Requirements Test methods and Conditions Appearance Tightness Test Residual Loss No defects which would adversely affect product performance. (pressure loss <.0 psi) < 0.05dB per incoming fiber Sample shall be pressurized to 6 psi (4.5kPa) and immersed in a water bath at 23±2 for more than 30 minutes. Source wavelength: 550±30 nm Fiber Organization Vibration Test Axial Tension Test (Tensile Test) < 0.05dB per incoming fiber (pressure loss <.0 psi) < 0.dB per incoming fiber (pressure loss <.0 psi) < 0.dB per incoming fiber Source wavelength: 550±30 nm Inner pressure of closure : 6 psi (4.5kPa) Frequency: 5Hz-55Hz-5Hz per 2min. Amplitude: mm Test time: 2hrs Sample shall be pressurized to 6 psi (4.5kPa). A Load of cable dia./45 000N shall be applied to cable in the longitudinal axis of the cable for 8 hours. Sample shall be subjected to tightness test. 6

2. Specifications Properties Requirements Test methods and Conditions Torsion Test (Rotating Test) (pressure loss <.0 psi) The test sample shall be pressurized to 6 psi (4.5kPa). The extending cable shall be clamped rigidly at a distance D(cable outer dia.)/45 x0mm from the entrance port. The cable shall be rotated as a clockwise twist of 90 followed by a 80 twist counter-clockwise followed by a 90 clockwise twist back to the starting position per a cycle. The twisted cable shall be maintained in each position for 5 minutes. After two cycle per cable, sample shall be subjected to tightness test. Flexure Test (Bending Test) (pressure loss <.0 psi) The test sample shall be pressurized to 6 psi (4.5kPa) and clamped on a smooth, flat, horizontal surface. The extending cable shall be clamped at.0m form the end of the entrance port then bent 90 and the procedure repeated three rotation in the opposite direction. Each bending operation shall be held in each position for 5 minutes. After the test, sample shall be subjected to tightness test. Impact Test (pressure loss <.0 psi) Free from cracks Duration time: 2hrs at 20±3 2.4kg steel ball shall be dropped freely and vertically from a height of.0m in to the center. After the test, sample shall be subjected to tightness test. 7

2. Specifications Properties Requirements Test methods and Conditions Static Load Test (Compression) (pressure loss <.0 psi) Free from cracks Duration time: 2hrs at 20±3 and 40±3 A static load of 000N shall be placed on the closure for 5minutes using a circular tool of 5 cm2 surface area. After the test, sample shall be subjected to tightness test. Handling Test (Drop test) Environment Temperature Test (Thermal Cycle Test) Chemical Test (pressure loss <.0 psi) No mechanical damage (pressure loss <.0 psi) < 0.dB per incoming fiber (pressure loss <.0 psi) No visible corrosion No mechanical damage Duration time: 2hrs at 20±3 The sample shall be subjected to a vertical drop from a height of 76cm. After the test, sample shall be subjected to tightness test. Sample shall be subjected to 20 cycles defined as follows: 23 to -35, hrs transition -35 for 2 hrs -35 to 75, 2hrs transition 75 for 2 hrs 75 to 23, hrs transition After the test, sample shall be subjected to tightness test. The test sample shall be pressurized to 6 psi (4.5kPa) and immersed in the three test fluids ( ph2 Hcl, ph2 NaOH, 0% IGEPAL ) for 20 hours. After the test, sample shall be subjected to tightness test, impact and compression test at 20±3. 8

2. Specifications Properties Requirements Test methods and Conditions Water Immersion Test No water permeation No visible corrosion The assembled closure shall be immersed in water of depth.5m for 20days. Re-entry Test (Repeated Usage Test) (pressure loss <.0 psi) After completing the thermal cycle test, sample shall be reassembled for 3 times and subjected to tightness test. Dielectric Test No damage or cracking Between cable sheath retainer and closure outside surface, apply a 0kV DC power for minute. UV Resistance Test The specimen shall not cause a reduction in tensile strength greater than 25%. Measure and record the tensile strength of 5 test bars per ASTM D 638 using a crosshead speed of 50 mm/min. Using the xenon lamp of wavelength between 300 and 700 nm, expose the 5 test bars to UV radiation of 390w/ m2 ±0% for 500 hours. Repeat the tensile strength measurements on the exposed test bars. 9

3. Evaluations Evaluations of closures Pass BellCore Location: LG Cable Indong Facility Inspector: Won, young-joon Test Period: Pass Location: Dacom Test & Inspection Institute Inspector: Kang, soo-chang Test Period: Pass Korean Telecom Standard KT( 표준 ) - 645-3294-- Location: Korea Telecom Network Institute(Dae-jon) Inspecting Breau: Korea Telecom Procurement Headquater Inspector: Jung, Kee-jung, Kang, bong-kwon Test Period: Awarded Certificate of Excellent Quallity Location/organizer: Agency for Technology and Standards,Ministry of Commerce, Industry & Energy Inspecting Breau: Ministry of Commerce, Industry & Energy Test Period: 0

3. Evaluations Pictures of the test. Residual Loss and Fiber Organization Test Tightness Test Environment Temperature Test (Thermal Cycle Test) Impact Test Axial Tension Test (Tensile Test) Vibration Test Chemical Test

3. Evaluations Pictures of the test. Static Load Test (Compression) Torsion Test (Rotating Test) Immersion Test Flexure Test (Bending Test) Dielectric Test (Current) (Voltage) 2

4. Ordering Information FOC Option 2 - Heat Shrik Tube Count(~44) Option - SB: Support Bracket, NN None Tray Count(2 ~ 6) : 2 Port 2: 3 Port Model: M, S, SS 3