INSTRUM. Pressure regulators Flow restrictors Safety elements. For protecting explosive, corrosive and sterile processes with inert gases

Similar documents
CAMASS. Calibration Centre. Gas flow technology and services

CAMASS. Calibration Centre. Gas flow technology and services

COMBIMASS. Thermal gas flow measurement system. For measuring and balancing of normal volumetric or gas mass flows

VACOMASS. The modular air supply system in wastewater treatment plants

Tank Blanketing Regulators

Tank Blanketing Regulators

ZUERCHER BRCeb/BSCeb Series

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Volume 6. for safety and environment

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Blanketing Valve ZM-R. low pressure reducing valve

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Pressure & Temperature Switches

Neotecha Tank Sampling Sapro

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Tank Blanketing Pressure Regulators RHPS Series

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Edition for safety and environment

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Pressure Reducing Valve DMV 750 set range: bar

Valves. Diaphragm shut-off valves, kidney-type

Neotecha Tank Sampling Sapro

Differential pressure gauge For the process industry Model , all-metal media chamber

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

Premium Series: Pressure, Differential Pressure and Level Transmitters. PASCAL Ci4. Chemical industry Mechanical engineering Process industry

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

SERIES 3000 BLANKET GAS REGULATORS

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

Flow metering in gases Introduction to COMBIMASS family

DIAPHRAGM GAS SAMPLING PUMPS

Gas Pressure Regulator HON 200

HP/UHP Spring-Loaded Regulator

High-performance submersible pressure transmitter For level measurement Model LH-10

Products for Cryogenic Applications

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Mechanical Pressure Measurement

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Anderson Greenwood Type 4142 piped away pressure relief valves

Instruction Manual Contact Pressure Vacuum Gauge

ZUERCHER BR Series LOW PRESSURE IN-LINE & ANGLE-PATTERN TANK PRESSURE REDUCING REGULATORS

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Pressure Measurement Single-range transmitters for general applications

OPTIBAR P 1010 C Technical Datasheet

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Valvex Valves for Mining Applications

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C)

Safety Relief Valve HON 832

LESER at a glance. The-Safety-Valve.com

NGN Series nitrogen generator

Total Pressure Regulator Solutions.

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Your Specialist and Partner in the Field of Pharmaceutical Applications

SITRANS P measuring instruments for pressure

evoguard The valve series for aseptic applications

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Types ACE95 and ACE95Sr Tank Blanketing Valves

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Your Specialist and Partner in the Field of Tank Blanketing

CAST IRON SAFETY VALVE TYPE 6301

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Transferring and Storage

Diaphragm Accumulators

CVS10 Sanitary Check Valves

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

GA24 Technical Datasheet

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Diaphragm Accumulators

How to specify a product. Process Sensors and Mechanical Instruments

High-performance submersible pressure transmitter For level measurement Model LH-20

Instruction Manual Differential Pressure Transmitter

Liquid Ring Compressors Engineered-to-Order Compressor Systems

DIAPHRAGM GAS SAMPLING PUMPS

Gas Control Systems. Product overview

Type 4708 Supply Pressure Regulator

Gas Pressure Regulator R 51

High-performance submersible pressure transmitter For level measurement Model LH-10

Type 4708 Supply Pressure Regulator

Differential pressure

Premium Solutions for Gas and Biogas Handling

Diaphragm Accumulators

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

High-performance submersible pressure transmitter For level measurement Model LH-20

ATM.1ST/Ex - High Precision Transmitter

Pressure Transmitter P41

Gas Control Systems. Product overview

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Transcription:

INSTRUM Pressure s Flow restrictors Safety elements For protecting explosive, corrosive and sterile processes with inert gases

We apply pressure in tanks, reactors, centrifuges and continuous agitated tank reactors in the process engineering industry. We offer suitable fittings made of corrosion-resistant materials for blanketing of liquids with an inert gas atmosphere. We design and build systems for tank blanketing, inerting, product transfer and sterilisation, with particular focus on automatic mechanical s that operate without auxiliary power, including pressure s for reduction, relief, negative and differential pressure, check valves for positive and negative pressure. The INSTRUM approach enables you to significantly reduce your installation and running costs while increasing operational reliability. Please contact us. We will be glad to give you good advice.

Tank blanketing and inerting with INSTRUM Inert gas in FI PICV PCV FI In many fields of modern process engineering, where products or liquids are taken from reservoirs and tanks for processing, it makes sense to protect these with an inert gas atmosphere. It prevents oxidation, contamination or serves as explosion protection. The aim is to ensure operational safety through controlled ventilation, while minimising the effect on the environment and the costs for the inert gases. INSTRUM units are used for: protection and product quality Explosion protection Process optimisation Environmental protection Health protection Odour prevention Compliance with statutory regulations INSTRUM products can be supplied in conformity with: Pressure Equipment Directive - PED (97/23/EC) Explosive atmospheres - Explosion prevention and protection acc. DIN EN 1127-1 Non-electrical equipment intended for use in potentially explosive atmospheres - Protection by constructional safety c acc. DIN EN 13463-5 Rules for Pressure Equipment acc. AD 2000 Code CE marking ATEX 95 (EX II 3G / 3GD c IIA T4 X) Blanketing, conveying and sterilisation The independent tank blanketing systems from INSTRUM can be used to protect media in storage tanks, mixing vessels and other containers with nitrogen, carbon dioxide or other inert gases. For reasons of environmental protection tank safety has become a main concern for operators. Blanketing with inert nitrogen gas is the preferred method for explosion and oxidation protection. Exact regulation in the low-pressure range saves significant costs and achieves maximum safety. For preventing oxidation of medium and the inner tank walls Ensuring product quality and corrosion protection For avoiding ignitable vapour / air / gas mixtures Explosion protection For avoiding health risk and odour nuisance in the workplace Environmental and health protection Pressure regulation system for different process steps: blanketing, conveying and sterilisation Process optimisation and cost-saving Blanketing in the low psi range and expansion of the operating point help system operators to minimise the inert gas consumption and the costs for waste air treatment Cost-saving

Blanketing 0 1 Conveying Pressure Back pressure For optimum blanketing two pressure s are required, one pressure for reduction of the incoming nitrogen (intake / = low-pressure regulating valve) and one back pressure as discharge valve for the waste gas (expiration / = low pressure relief valve). The aim of ventilation is to maintain an inert state in the tank or equipment in all operating stages of a production process. Blanketing can take place with positive or negative pressure. Positive pressure is used to prevent oxygen from entering the process. Negative pressure is used to prevent process gas, e.g. toxic media, from escaping. 2,015 bar (30.2 psi) 2,04 bar (30.6 psi) 2,015 bar (30.2 psi) In addition to ventilation, blanketing with variable pressure (up to 4 bar / 58 psi) enables to press out the product from the tank, instead of using a pump. The pressure build-up takes place via same s that are used for tank blanketing. Pressure Pressure Back pressure Back pressure Typical basic settings for tank or reservoir inertising are for the pressure () and for the back pressure (). Before a tank is filled with product the empty tank is purged with nitrogen in order to drive out the air. Typically 3 to 5 times the tank volume is used. Once the discharge valve is closed the gas pressure increases to the set value of. After purging the tank is filled with product. For this the product valve closes and the valve is opened. With increasing product level in the tank the pressure in the headspace increases until the set value of is reached. Nitrogen is then discharged via the back pressure into the gas processing unit or atmosphere. If product is discharged, the pressure in the headspace decreases. At the pressure () opens to allow nitrogen to flow in, in order to prevent the pressure from decreasing further.the pressure () and the back pressure () ensure that the pressure range for nitrogen blanketing is between and under all operating conditions. To reduce the costs for inert gas the operating points should be as far apart as possible, in order to achieve a maximum pressure range without gas consumption. This reduces nitrogen costs, product losses in the waste gas system and waste gas treatment costs. 0 1 2,015 bar (30.2 psi) 0 1 2,04 bar (30.6 psi) 2,015 bar (30.2 psi) The required servo pressure is applied to the pressure () and back pressure () through manual or electropneumatic switching (I/P converter). The new set value for the pressure () causes it to open, so that nitrogen flows into the tank. The new set value for the back pressure () causes the increased pressure to be maintained in the tank, according to the specified pressure ratio. This pressure can be used to transfer the product by opening the discharge valve. The discharged product is replaced by nitrogen, in order to ensure a constant conveying pressure, irrespective of the product level in the tank. transfer is terminated by closing the product valve and setting the servo pressure at the pressure () and the back pressure () to zero. This causes the headspace pressure to decrease to the ventilation pressure of. The normal tank ventilation state has thus been restored.

Inert gas 8 bar (116 psi) max. Supply pressure Flowmeter Steam 4-8 bar (58-116 psi) Z + 2,5 bar (0.2 psi + 36 psi) 40 C Conveying Compressed air or nitrogen 5-10 bar (73-145 psi) Sterilisation 2,5 bar (36 psi) 1 0 2 + 2,5 bar (0.6 psi + 36 psi) Z Compressed air or nitrogen 5-10 bar (73-145 psi) Sterilisation For tank sterilisation, a diaphragm seal, a steam flowmeter and an associated controller are required in addition to the pressure () and back pressure () in sterile design. Steam is used for sterilisation. A servo pressure of 2,5 bar (36 psi) is applied to the pressure (e.g. set to / 0.2 psi) and back pressure (e.g. set to / 0.6 psi). This servo pressure corresponds to the required sterilisation temperature. INSTRUM High-quality materials High-quality materials and precision finish ensure corrosion resistance and excellent leak-tightness at zero flow. We use the following materials as standard: Stainless steel (1.4435 / 1.4404 / 1.4408) for all parts in contact with the product Hastelloy (C22, C276), PP, PVDF and PFA lined for highly corrosive applications PTFE membranes and seals (e.g. Teflon ) FFKM (e.g. Kalrez ), FKM (e.g. Viton ) for the control seat Other special materials (e.g. titanium, tantalum) are available on request Inert gas 8 bar (116 psi) max. Supply pressure Flowmeter Steam 4-8 bar (58-116 psi) Inert gas 8 bar (116 psi) max. Supply pressure Flowmeter Steam 4-8 bar (58-116 psi) Z Z 2,5 bar (36 psi) 15 mbar + 2,5 bar (0.2 psi + 36 psi) Conveying 125 C 95 C Conveying Sterilisation 1 0 2 Z Compressed air or nitrogen 5-10 bar (73-145 psi) Sterilisation 2,5 bar (36 psi) + 2,5 bar (0.6 psi + 36 psi) 2,5 bar (36 psi) 1 0 2 Z Initially the steam condenses at the cold container wall. The pressure increases slowly. The pressure and the corresponding temperature are constant at any point in the sterile zone. The steam flow rate falls to the quantity required for compensating the temperature loss through convection. The temperature and flowmetering system reports the start of the sterilisation time to the control system. After the sterilisation the servo pressure and the sterile steam supply are switched off, and the system switches to inert gas ventilation mode. The back pressure reduces the steam pressure in the tank to. The sterilisation technique with lowpressure s avoids cold spots, is particularly reliable and requires only little additional equipment, resulting in a significant reduction of investment costs. A computer animation explaining the process is available on our website: www.instrum.ch INSTRUM inert gas control systems ensure High control precision for small blanketing pressures with minimum hysteresis Precise pressure regulation at minimum and maximum flow rate with gas-tight seal Operational safety through independent system (no auxiliary power required for operation) Simple installation, commissioning and maintenance Corrosion- and temperature-resistant finish, suitable for outdoor installation Rugged design and high-quality materials Years of maintenance-free operation

Low-pressure s and back pressure s INSTRUM modular design Regulating range -0,8 to 5 bar (-11.6 psi to 72.5 psi), ½ to 4 40 60 The modular design enables our s to be used for a wide range of applications and offers flexibility through three different types (inline, wafer and angle), with special versions for CIP and SIP applications. 20 80 1.4571 0 mbar 100 High surface quality and materials with corresponding certifications ensure perfect adaptation for different applications such as: 110870 Food Pharmaceutical Biotech Cosmetics Chemicals and fine chemicals General process engineering Extended application options The spring-loaded design with large diaphragm results in high-precision regulation. A robust, supported mechanism with guided valve seat allows operating pressures from vacuum up to 5 bar (72.5 psi) with additional functions such as Tank blanketing with variable pressure, e.g. for pneumatic product conveying Sterilisation, conveying and ventilation Pneumatic pressure control for complex processes in continuous agitated tank reactors. INSTRUM s for sterile applications Our sterile s with reduced dead space and self-draining design enable you to meet quality requirements for CIP or SIP applications. We use certified materials for all our seals. The units enable sterilisation and maintenance of a sterile atmosphere without the need for a sterile filter.

Pressure s, differential pressure s, back pressure s Regulating range between 0,5 and 200 bar (7.2 and 2900 psi), ½ to 2 For pressure reduction, differential pressure regulation and pressure control for gases, liquids and hazardous media in process engineering applications. The units are specially designed for chemical system engineering and offer maximum reliability under difficult operating conditions. The pressure s are available in a wide range of materials for optimum adaptation to the process requirements. The same highquality materials are available as for our low-pressure s. Various elastomer and metallic membranes and bellows made from stainless steel and hastelloy are available as separating elements between the medium. The operates on the principle of force balance. Fail-safe characteristics and additional protection against gas leakage into the atmosphere in the event of a diaphragm failure are achieved by a gas spring (dome) instead of a mechanical spring. The output pressure follows the dome set pressure without delay. The ideal characteristic curve enables high-precision operation up to the maximum flow rate without pressure drop. Pressure reducers for gas modules INSTRUM offers pressure s for pressure reduction of hazardous, aggressive or toxic gases such as HCI, BF 3, CL 2 etc. from high pressure in transport containers to a few bar (psi). For monogas modules the is equipped with a pressure-compensated seat. For multigas modules a direct-acting seat with no dead space is used, in order to facilitate purging during gas changeover. INSTRUM s, check valves and special units Explosion and environmental protection, product purity and cost-saving Backflow preventers These system separators reliably prevent backflow of gases and liquids and serve to separate different system components. Irrespective of the system pressure, flow is only possible with positive pressure gradient between and. The separator remains closed until pressure equalisation is achieved. Pneumatic pressure transducers 1:1 Isolating transducers for pressures between 0 and 4 bar (0 and 58 psi) for application in highly corrosive or highpurity systems. FLOFIX flow These automatic flow s are used for achieving constant flow under varying pressure, as flow s for dosing, distribution, cooling circuits etc., or as flow limiting devices for protection against overload in excess flow conditions or against water shock etc. The FLOFIX is primarily designed for liquids, although it can also be used for gases. Different cartridges can be combined, depending on the application.

Check valves for positive and negative pressure Check valves allow flow in one direction while automatically preventing backflow. Depending on the application they may be named as safety elements or vacuum breakers, for example. INSTRUM intermediate flange-type valves are suitable for position-independent installation between piping flanges for gases and steam. The special shape of the guide, spring cap and valve disc can enable opening pressures between as little as 2 mbar (0.03 psi) and a maximum of 100 mbar (1.45 psi) to be achieved for nominal widths between ½ and 4. Non-corroding materials are used for the housings, internals and springs (stainless steel, hastelloy, tantalum and PTFE), making the unit suitable for application in aggressive environments. Plastic s for highly corrosive applications Plastic s and back pressure s are used in exceptionally corrosive applications due to hydrocarbons, acids or caustic. The units are made from PP, PP el or PVDF in a wide range of combinations of casings and internals. Springs in contact with the product are made from hastelloy, tantalum or plastic. Our pressure s are available as special versions made from highly corrosion-resistant materials (such as tantalum, for example) in combination with plasticlined metal housings, offering scope on application for virtually any tasks in aggressive environments. The performance data are similar to those of metallic pressure s. The light-weight s and back pressure s are self-draining and offer convenient and cost-effective installation. They are exclusively used for blanketing applications. They are used in a wide range of industries, particularly in the chemical and pharmaceutical industry.

LOCAL DISTRIBUTOR PRODUCTION DISTRIBUTION BINDER GmbH Buchbrunnenweg 18 89081 Ulm, Germany Tel +49 731 18998-0 Fax +49 731 18998-88 info@bindergroup.info INSTRUM AG Waldeckstrasse 100 4127 Birsfelden, Switzerland Tel +41 61 3121136 Fax +41 61 3121126 info@instrum.ch www.instrum.ch BETA BV Verrijn Stuartlaan 22 2288 EL Rijswijk, The Netherlands Tel +31 70 3199700 Fax +31 70 3199790 info@beta-b.nl www.beta-b.nl Binder Engineering GmbH Buchbrunnenweg 18 89081 Ulm, Germany Tel +49 731 96826-0 Fax +49 731 96826-99 info@bindergroup.info Binder Engineering AG Waldeckstrasse 100 4127 Birsfelden, Switzerland Tel +41 61 3199130 Fax +41 61 3199134 info@bindergroup.info Binder Engineering BV Cort van der Lindenstraat 25 2288 EV Rijswijk, The Netherlands Tel +31 70 3074300 Fax +31 70 3074399 sales@binder-engineering.nl Binder Engineering NV Bergensesteenweg 709 A 1600 Sint-Pieters-Leeuw, Belgium Tel +32 2 3000795 Fax +32 2 3000797 info@binder-engineering.be Binder Engineering SAS 41, Place Jules Ferry 92120 Montrouge, France Tel +33 1 46120445 Fax +33 1 46120442 binder@mesa.fr Binder Instrumentation Pte Ltd 25 International Business Park # 04-06 German Centre Singapore 609916 Tel +65 6 5627637 Fax +65 6 5627638 eddy.eng@bindergroup.info Binder Instrumentation Trading (Shanghai) Co., Ltd Room 106A Xingyuan Tech Building Guiping Road 418 Shanghai, P.R. China, 200233 Tel +86 21 64959889 Fax +86 21 64959887 info@binder-instrumentation.cn Please visit our website for more information and distribution in other countries: Please contact the company with the address shown in red or the local distributor. All rights reserved. Subject to change without notice.. INCH-M-PROS-IMAGE001-EN-R01 Fotodesign Horst Haas