Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Similar documents
Shut-off valve Type QDV

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15

Safety relief valves Type SFA 15 and SFA 15-50

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

for for Industrial Refrigeration

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Safety relief valves SFV 20-25

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure regulating valves Types OFV, OFV-SS

Hand operated regulating valves Types REG-SA and REG-SB

Regulating valves REG-SA and REG-SB

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves Type BSV-8

Safety relief valves Type SFV 20-25

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Pilot valves for pilot operated servo valves

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid Valves, one - or two step, on/off ICLX

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Float valves Types SV 4, SV 5 and SV 6

Float valves Types SV 1 and SV 3

Dual position solenoid valve Type ICSH 25-80

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

AVPQ/AVPQ-F, PN 16. Application

Expansion Thermometers Stainless Steel Series, Model 70

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

AVP-F. p setting range (bar) Code No. 003H6200

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

Description Advanced Features Typical Applications

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

Seated valves VRB 3, VRG 3

Presetting Valve Type RA-N with Flange Connection

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

CASH VALVE TYPE KP BACK PRESSURE VALVES

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Series MG Mixing Tubes

Air Operated Hydraulic Pumping Systems to 50,000 psi

Refrigerant Gases Valves

STAD. Balancing valves DN 15-50

Selection of ICF made easy Save even more time with ICF

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

shutoff valves 900 Series psig Manual Shutoff Valves

Proportional Relief Valves

Armatures for analytical probes

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Horizontal Bladder Tanks

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Vertical Bladder Tanks

Valve Station ICF 15, 20 and 25

Slam Shut Valves SCN

Materials : Stainless steel ASTM A351 CF8M

Precision and Instrument Regulators 1/4" port size

Pressure Equalising Valves Model , for Differential Pressure Gauges

Barcol-Air BRM Radiant Module

kyone for All - Unique Mixproof

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

INDUSTRIAL EXCESS ESS FLOW VALVES

STAP. Differential pressure controllers DN , ANSI flanges

STAD-C. Balancing valves DN 15-50

Model MTB-ASME Vertical Bladder Tanks

Norval Pressure regulator

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Mechanical Pressure Measurement

STAP. Differential pressure controller DN 15-50

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Specialty Gas Equipment Catalogue

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

STAINLESS STEEL OVERFLOW VALVE TYPE 417

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Technical Information Cleanfit CUA451

HP/UHP Spring-Loaded Regulator

Technical Data Sheet T 2025

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Transcription:

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING Technical leaflet

Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems containing refrigerant (ammonia) under pressure. The valve will close immediately on release of the handle, thus protecting user and environment against unne cessary refrigerant leaks. The valve should as a rule be installed as illustrated in fig. 1. In order to pre vent hydraulic pressure building up between the stop valve and the QDV an integral relief device is included as part of the cone arrangement, which will open at approx. 25 bar g (363 psig). QDV is designed to meet the safety demands specified by national and international authorities within industrial refrigeration. Fig. 1 Features QDV is generaly used with R717 (ammonia) but the valve is also applicable to all other common non flammable refrigerants and non corrosive gases/liquids dependent on sealing material compatibility Meets the safety demands within industrial refrigeration Handle can be positioned 360 Built-in integral relief device opening over 25 bar g (proventing hydraulic pressure building up between stop valve and QDV). Can be supplied together with a stop valve for quick on site mounting Max. operating pressure: 40 bar g (580 psi g). Temperature range: 50/+150 C ( 58/+302 F). Classification: To get an updated list of certification on the products please contact your local Danfoss Sales Company. 2 DKRCI.PD.KL0.A4.02 / 520H1199 Danfoss A/S (AC-AKC / frz), 08-2009

Design Connections Available with the following connections: Inlet: Welding DIN (EN 10220) ½ in. FPT 3/4 in. FPT Outlet: G 3/4 in. pipe thread (ISO 228/1) ½ in. FPT 3/4 in. FPT Optional extras for outlet: Welding nipple DIN (EN 10220) Hose connection Other types of connection are available on request. QDV - SVA combinations Combinations of the QDV together with a dedicated SVA have been established for easy selection. Please study page 6 to find the code numbers for these combinations. Installation For further information refer to installation instruction for QDV. Technical data Refrigerants QDV is generally used with R717 (ammonia) but the valve is also applicable to all other common non flammable refrigerants and non corrosive gases/liquids dependent on sealing material compatibility. QDV is a backpressure dependent valve. If any tube or hose is mounted on the outlet of the QDV it has to be calculated to prevent blackpressure building up when relieving. For further information please see installation instruction for QDV. Flammable hydrocarbons are not recommended, for further information please contact your local Danfoss Sales Company. Temperature range 50/+150 C ( 58/+302 F). Pressure The valve is designed for: Maximum operating pressure of 40 bar g (580 psi g) Danfoss A/S (AC-AKC / frz), 08-2009 DKRCI.PD.KL0.A4.02 / 520H1199 3

Material specification QDV 15 No. Part Material DIN/EN ISO ASTM 1 Housing Steel G20Mn5QT EN10213-3 LCC A352 2 Bonnet Stainless steel X110CrNi 3 Spindle/Cone Stainless steel X110CrNi S189 17440 S189 17440 Type 17 683/13 Type 17 683/13 AISI 303 AISI 303 4 Spring Steel 11SMn30 Type 2 Grade 1213 5 Wear ring EN10087 R683/9 A29 6 O-ring Cloroprene Hose connection for outlet No. Part Material 12a O-rings Cloroprene (Neoprene) 12c Stub for hose Steel 12d Union nut Steel Welding nipple connection for outlet No. Part Material 13a Al-packing Aluminium 13b Welding nipple Steel 13c Union nut Steel 4 DKRCI.PD.KL0.A4.02 / 520H1199 Danfoss A/S (AC-AKC / frz), 08-2009

Connections ØD 1 ØD 3 ØD 4 ØD 5 QDV 15 DIN 15 mm 12 36.5 16.7 21.3 in. 0.47 1.44 0.66 0.84 ØD 7 ØD 8 QDV 15 ½" FPT mm 34 36.5 in. 1.34 1.44 ØD 7 ØD 8 QDV 15 3/4" FPT mm 34 36.5 in. 1.34 1.44 ØD 1 ØD 3 ØD 8 QDV 15 DIN 15 mm 12 36.5 34 in. 0.47 1.44 1.34 FPT 1/2" 13.5 T OD T kv-straight m 3 /h Cv-straight USgal/min OD SVA-ST DIN 15 mm 21.3 2.3 in. 0.839 0.091 4.9 5.7 FPT 1/2" 13.5 T ID SVA-ST SOC ½ in. ID T L k v-straight m 3 /h mm 21.8 6.0 10 in. 0.858 0.235 0.39 Cv-straight USgal/min 4.9 5.7 L Danfoss A/S (AC-AKC / frz), 08-2009 DKRCI.PD.KL0.A4.02 / 520H1199 5

Dimensions QDV 15 (stand alone) QDV 15 mounted on SVA valve Valve size A C max E QDV 15 mm 45 185 109 in. 1.77 7.28 4.29 Ordering How to order The table below is used to identify the valve required. Type Inlet Outlet Code no. QDV 15 DN 15 DN 15 G 3/4 in. 148H3272 QDV 15 ½ in. FPT ½ in. FPT ½ in. FPT 148H3273 QDV 15 3 / 4 in. FPT 3/4 in. FPT 3/4 in. FPT 148H3274 QDV 15 DN 15 + SVA-ST DN 15 H-WHEEL* DN 15 G 3/4 in. 148H3310 QDV 15 ½ in. FPT + SVA-ST SOC ½ in. H-WHEEL* ½ in. SOC ½ in. FPT 148H3311 Fittings for hose connection 2469+065 Fittings for welding connection 2469+066 * Two valves are supplied in one box and should be mounted on site. The indicated inlet is for the stop valve - The indicated outlet is for the oil drain valve. Important! Where products need to be certified according to specific certification societies or where higher pressures are required, the relevant information should be included at the time of order. 6 DKRCI.PD.KL0.A4.02 / 520H1199 Danfoss A/S (AC-AKC / frz), 08-2009

Danfoss A/S (AC-AKC / frz), 08-2009 DKRCI.PD.KL0.A4.02 / 520H1199 7

8 DKRCI.PD.KL0.A4.02 / 520H1199 Danfoss A/S (AC-AKC / frz), 08-2009