CRYO. SuperVariTemp Magnet Inserts

Similar documents
Variable Temperature Storage Dewar Mount Inserts

CRYO INDUSTRIES. Liquid Helium Research Dewars

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Microscopy Cryogenic WORKSTATION. Performance by Design

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

attoliquid Liquid Research Cryostats

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

Current Leads for Cryogenic Systems

Baffles and Traps Cryotrap

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Liquid Helium Bath Cryostat

First Experimental Data of the Cryogenic Safety Test Facility PICARD

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

Heliox TM. He systems to suit all applications

High Pressure Equipment Pressure Vessels and Reactors Index

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Storage and transfer of cryofluids

Cryogenics of SRF Spoke Cavity Development at SMTF

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

BIMA cryogenics (Dick Plambeck, 18jan2007)

Pilot Assembly Replacement Manual Parts Needed: Phillips head screwdriver #2 Two Adjustable Crescent Wrenches Replacement Pilot Assembly

Ascend Aeon. User Manual. Innovation with Integrity. Version NMR

Residual Gas Analysis Systems for Industry

Transition your department towards more productive helium-free MR operations 1

Ascend. User Manual. Innovation with Integrity. Version NMR

Ascend DNP. User Manual. Innovation with Integrity. Version NMR

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Thanks for choosing EJAI SOLAR product

Dean Pump Self-Priming Chemical Process Pumps

High Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Valves. Controllers. Valves Two Types

Heliox Sorption Pumped 3 He Refrigerator Systems

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Pump out insert (condenser and still lines) overnight with turbo pump

Oxford Instruments Austin, Inc.

The Helium Leak Detector

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

National Accelerator Laboratory

Design of a Solid Wall Transonic Wind Tunnel

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

Sprocket Selection Guidelines

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

Safety in Cryogenic Operations at RHIC *

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Precision and Instrument Regulators 1/4" port size

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

EXERCISE 2: THE VACUUM SYSTEM

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Cryogenic System for a Large Superconducting Magnet in Space

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Parallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL!

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Series Environmental Chambers

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Cryomodule Maintenance Workshop Maintenance, Repair Strategies, and Fault Scenarios. J. Ozelis Senior SRF Coordinator

Installing a Probe. Typical Installation

Updated: Variable Temperature

Directional Controls

UHP - UHV APPLICATIONS

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Fermilab MTF Cryogenic System & Vertical RF Cavity Test Facility. Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006

Oxygen Contamination

Float Operated Level Controllers

World Area Differences Technical Information

Orbital Motors Type OMP X and OMR X

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

MASSIVE GAS INJECTION SYSTEMS FOR DISRUPTION MITIGATION ON THE DIII-D TOKAMAK

Precision Liquid Settlement Array Manual

North American Orifice Metering System

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

PROCESS MONITORING AND CONTROL

To be published in the proceeding of ICEC-22, Seoul Korea, July 2008 MICE Note 231 1

Coiling Tube with Twist-Proof Fitting


ATOC Meteorological Tower (6 meter-4 level) Guide

PVQ 13 A2 R SE 1 S 20 C-11 D

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Bruker Sample Transport

Transcription:

SuperVariTemp Magnet Inserts

Cryo Industries Sample in Vapor Variable Temperature Inserts (VTIs) fit into the bore of superconducting magnets and provide variable temperatures from <1.4 to 300 K. Samples are cooled by insertion into flowing helium gas exiting from the vaporizer (also known as the diffuser or heat exchanger). A small amount of liquid helium is drawn from the magnet s bath into the vaporizer located at the bottom of the sample tube. The liquid helium is vaporized and heated to your pre-selected temperature. The gas enters the sample zone and the sample is cooled to temperature of the flowing gas. Systems are available with choice of many standard sample tube sizes from 0.50 to greater than 4 or more inches. Inserts can be ordered to fit your existing magnet systems. The Super Variable Temperature (SVT) Inserts are available in three styles: Separate (top-loading) Insert Magnet Support Combo: variable temperature and magnet support. Combination Insert: Dynamic SuperVariTemp Insert and removeable Static Exchange Gas Insert: Two Inserts in One! All styles feature top-loading samples and high refrigeration capacity. All systems can be configured with vapor sheilding for extended high temperature operation. Helium-3 inserts are also available which install directly into or interchange with the VTI. Cryo Industries is able to offer the SuperVariTemp Magnet Insert alone or as part of a complete Superconducting Magnet System, that includes: High performance dewar SuperVariTemp Insert Standard Solenoids from 5 T to 17 T Liquid Helium Level Probe with electronic readout Integrated Superconducting Magnet Power System Temperature Sensors Temperature Controllers Superconducting Magnet System with Mossbauer, Magnetic Measurements, SuperVariTemp Magnet Insert Spectroscopy, Materials Research, Vibrating Sample Magnetometer, Scanning Tunneling Microscope or whatever your needs - CRYO has the capability to design and build superconducting magnet systems to meet your requirements.

LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW 25 4.87 DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. High Temperature Superconductor Testing High Current Leads Installed to Sample 45.00 O.D. 1.50 O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) 1.38 1.50 0.5 APPROX. O.D. CRUSHED INDIUM SEAL O.D. 8.25 3.75 0.50 (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT

SuperVariTemp Insert w/exchange Gas Insert LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW 25 4.87 DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. The exchange gas region is turbulent free and provides ultra stable temperatures. When the exchange gas insert is in use, helium vapor flows around (not in) the sample tube. The top-loading exchange gas insert easily removes for standard sample in vapor SuperVariTemp operation. 45.00 O.D. 1.50 O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) 1.38 1.50 0.5 APPROX. O.D. CRUSHED INDIUM SEAL O.D. 8.25 3.75 0.50 (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT

SuperVariTemp Insert w/integral Magnet Support SAFETY QUENCH RELIEF WITH NW25 S (2) HIGH CURRENT LEADS (2) 10 PIN S SAFETY PRESSURE RELIEF 1.50 NOM. LADISH ISO NW 25 0.06 (4) LIFTING PROVISIONS (1) 19 PIN INSERT EVACUATION VALVE WITH SAFETY PRESSURE RELIEF O.D. CUSTOMER SPECIFIED (1) 10 PIN HELIUM FILL WITH 3/8 QUICK CONNECT HELIUM VENT WITH 3/8 QUICK CONNECT 5.50 TOP BOLT CIRCLE CUSTOMER SPECIFIED 4.00 1.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS BAFFLE O.D. CUSTOMER SPECIFIED (NOTE: O.D. OF BAFFLES ARE NORMALLY EQUAL TO OR LARGER THAN MAGNET O.D.) 45.00 1.00 O.D. SAMPLE TUBE 1.50 O.D. Magnet Support and SuperVariTemp Insert Combo - single integral unit! 1.44 3.00 O.D. MAGNET SUP RODS CRUSHED INDIUM SEAL 1.50 (RECOMENDED) 0.47 APPROX. 1.50 O.D. OUTER MAGNET TAIL MAGNET LENGTH TBD TOP OF MAGNET TO FIELD CENTER TBD 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND COPPER SAMPLE MOUNT WITH 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND #4-40 TAPPED HOLES FOR SAMPLE MOUNTING PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH INTEGRAL MAGNET SUP

SuperVariTemp Insert w/pita Shielding (2) 10 PIN S 10 PIN (8).209 DIAMETER CLEARANCE HOLES FOR M5 SCREWS EQ. SP. ON A 5.71" DIA. B.C. SAFETY PRESSURE RELIEF ISO NW-50 EVACUATION VALVE WITH SAFETY PRESSURE RELIEF AND ISO NW-25 ISO NW-40 6.14 O.D. 3.00.19 FLOW VALVE OPERATOR (4) M5 TAPPED HOLES FOR LIFTING AS SHOWN ON A 5.71" DIA. B.C. 5.00 (4) RADIATION BAFFLES 4.50 4.50 4.50 46.50 5 O.D. O.D. (SAMPLE TUBE) INTERMEDIATE RADIATION SHIELD When insert is run at higher temperatures, Intermediate Radiation Shielding decreases amount of heat that escapes into the helium bath, resulting in reduced helium boil off. 2.19 4.50 O.D. O.D. 12.25 5.25 COPPER SAMPLE MOUNT WITH HEATER, PROVISION FOR TEMPERATURE SENSORS AND (8) #4-40 HOLES FOR SAMPLE MOUNTING 6.00 2.81 HEATER, PROVISION FOR TEMPERATURE SENSORS AND 6.25 O.D. PROPRIETARY INFORMATION TITLE: MAGNET INSERT