Cryo Industries Sample in Vapor Variable Temperature Inserts (VTIs) fit into the bore of superconducting magnets and provide variable temperatures from <1.4 to 300 K. Samples are cooled by insertion into flowing helium gas exiting from the vaporizer (also known as the diffuser or heat exchanger). A small amount of liquid helium is drawn from the magnet s bath into the vaporizer located at the bottom of the sample tube. The liquid helium is vaporized and heated to your pre-selected temperature. The gas enters the sample zone and the sample is cooled to temperature of the flowing gas. Systems are available with choice of many standard sample tube sizes from 0.50 to greater than 4 or more inches. Inserts can be ordered to fit your existing magnet systems. The Super Variable Temperature (SVT) Inserts are available in three styles: Separate (top-loading) Insert Magnet Support Combo: variable temperature and magnet support. Combination Insert: Dynamic SuperVariTemp Insert and removeable Static Exchange Gas Insert: Two Inserts in One! All styles feature top-loading samples and high refrigeration capacity. All systems can be configured with vapor sheilding for extended high temperature operation. Helium-3 inserts are also available which install directly into or interchange with the VTI. Cryo Industries is able to offer the SuperVariTemp Magnet Insert alone or as part of a complete Superconducting Magnet System, that includes: High performance dewar SuperVariTemp Insert Standard Solenoids from 5 T to 17 T Liquid Helium Level Probe with electronic readout Integrated Superconducting Magnet Power System Temperature Sensors Temperature Controllers Superconducting Magnet System with Mossbauer, Magnetic Measurements, SuperVariTemp Magnet Insert Spectroscopy, Materials Research, Vibrating Sample Magnetometer, Scanning Tunneling Microscope or whatever your needs - CRYO has the capability to design and build superconducting magnet systems to meet your requirements.
LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW 25 4.87 DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. High Temperature Superconductor Testing High Current Leads Installed to Sample 45.00 O.D. 1.50 O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) 1.38 1.50 0.5 APPROX. O.D. CRUSHED INDIUM SEAL O.D. 8.25 3.75 0.50 (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT
SuperVariTemp Insert w/exchange Gas Insert LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW 25 4.87 DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. The exchange gas region is turbulent free and provides ultra stable temperatures. When the exchange gas insert is in use, helium vapor flows around (not in) the sample tube. The top-loading exchange gas insert easily removes for standard sample in vapor SuperVariTemp operation. 45.00 O.D. 1.50 O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) 1.38 1.50 0.5 APPROX. O.D. CRUSHED INDIUM SEAL O.D. 8.25 3.75 0.50 (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT
SuperVariTemp Insert w/integral Magnet Support SAFETY QUENCH RELIEF WITH NW25 S (2) HIGH CURRENT LEADS (2) 10 PIN S SAFETY PRESSURE RELIEF 1.50 NOM. LADISH ISO NW 25 0.06 (4) LIFTING PROVISIONS (1) 19 PIN INSERT EVACUATION VALVE WITH SAFETY PRESSURE RELIEF O.D. CUSTOMER SPECIFIED (1) 10 PIN HELIUM FILL WITH 3/8 QUICK CONNECT HELIUM VENT WITH 3/8 QUICK CONNECT 5.50 TOP BOLT CIRCLE CUSTOMER SPECIFIED 4.00 1.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS BAFFLE O.D. CUSTOMER SPECIFIED (NOTE: O.D. OF BAFFLES ARE NORMALLY EQUAL TO OR LARGER THAN MAGNET O.D.) 45.00 1.00 O.D. SAMPLE TUBE 1.50 O.D. Magnet Support and SuperVariTemp Insert Combo - single integral unit! 1.44 3.00 O.D. MAGNET SUP RODS CRUSHED INDIUM SEAL 1.50 (RECOMENDED) 0.47 APPROX. 1.50 O.D. OUTER MAGNET TAIL MAGNET LENGTH TBD TOP OF MAGNET TO FIELD CENTER TBD 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND COPPER SAMPLE MOUNT WITH 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND #4-40 TAPPED HOLES FOR SAMPLE MOUNTING PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH INTEGRAL MAGNET SUP
SuperVariTemp Insert w/pita Shielding (2) 10 PIN S 10 PIN (8).209 DIAMETER CLEARANCE HOLES FOR M5 SCREWS EQ. SP. ON A 5.71" DIA. B.C. SAFETY PRESSURE RELIEF ISO NW-50 EVACUATION VALVE WITH SAFETY PRESSURE RELIEF AND ISO NW-25 ISO NW-40 6.14 O.D. 3.00.19 FLOW VALVE OPERATOR (4) M5 TAPPED HOLES FOR LIFTING AS SHOWN ON A 5.71" DIA. B.C. 5.00 (4) RADIATION BAFFLES 4.50 4.50 4.50 46.50 5 O.D. O.D. (SAMPLE TUBE) INTERMEDIATE RADIATION SHIELD When insert is run at higher temperatures, Intermediate Radiation Shielding decreases amount of heat that escapes into the helium bath, resulting in reduced helium boil off. 2.19 4.50 O.D. O.D. 12.25 5.25 COPPER SAMPLE MOUNT WITH HEATER, PROVISION FOR TEMPERATURE SENSORS AND (8) #4-40 HOLES FOR SAMPLE MOUNTING 6.00 2.81 HEATER, PROVISION FOR TEMPERATURE SENSORS AND 6.25 O.D. PROPRIETARY INFORMATION TITLE: MAGNET INSERT