WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Similar documents
BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

Pneumatic high-pressure controller Model CPC7000

RS D RSF D with direct drive

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

Net$ync II. Net$ync II. System Controllers

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Pneumatic high-pressure controller Model CPC7000

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Oil-injected rotary screw compressors GA (VSD + )

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Built-in Purge Control Functions

HumiSys HF High Flow RH Generator

Safety Manual VEGAVIB series 60

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

Operating instructions. FOCUS compressor control for screw compressors

Panther 5 Acute Care Ventilator

ECL Comfort 110, application 131 (valid as of software version 2.00)

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

RM-80 respiration monitor

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

SSL. Smart Valve Positioner.

MAESTRO USER S MANUAL TIP00G-105 AIR COMPRESSORS

SSR. Smart Valve Positioner.

deltaflowc deltaflowc Venturi or Probe

Operating instructions for. For visualization of your measurements

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Safety Manual VEGAVIB series 60

Standard Chiller 1/4 compressors Manual version: /10/96

Operating instructions Electrical switching facility pco

Operating instructions. FOCUS compressor control for piston compressors

FTC130 Transmitter. Operating Manual

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Controller to regulate CO2 gas pressure EKC 326A

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Industrial Compressor Controls Standard Custom

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

ACV-10 Automatic Control Valve

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

HyperSecureLink V6.0x User Guide

A4s Operation Manual

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F

Technical Data Sheet MF010-O-LC

SonoMeter 30 Energy Meters

Roller AC Servo System

TR Electronic Pressure Regulator. User s Manual

SVEA II GSM Connector User Manual

High Pressure Breathing Air Compressors

Flamco Flexcon M-P Pump automat

Industrial pressure controller Model CPC4000

Oxygen Meter User Manual

PHOENIX L300i Best-in-class Helium Leak Detectors

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Typical Wayside Reader System Quotation

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

SPIROVENT VACUUM DEGASSERS

CCT-7320/ROC-2313 Reverse Osmosis Controller

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Squeegee Unit for MRS Multi-Recovery System

Drag racing system HL190 User Manual and installation guide

Manual Oxygen Analyzer A4009T

GAS FUEL VALVE FORM AGV5 OM 8-03

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Visualize Nitrogen Gas Consumption

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Precision digital pressure gauge Model CPG1000

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Pneumatic Outflow Control

Touch Screen Guide. OG-1500 and OG Part # T011

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Drag Racing Scoreboards

Programmable Submersible Level Transmitters

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

TH-1800-T TRX-700-CNG Converter

Screw Compressors 11-22kW

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

COMPRESSED AIR TEXTILES ENERGY EFFICIENCY

A TECHNICAL REFERENCE

e2c 20 - easy to connect

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

Digital dead-weight tester Model CPD8500

Control units. Installation and operating instructions Series: DP-Control

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

Model EXAxt AV550G. Averaging Oxygen Analyzer

STAND alone & p.c. VERSION

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Mass Flow Controller (MFC) for Gases

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Transcription:

1 INFORMATION and TECNICAL DESCRIPTION 14

2 AIRLEADER Professional Compressor Management + Compressed Air Visualisation + Alarm Service Management + AIRLEADER - has been the effective answer for compressed air users for more than 10 years - for the optimum compressor combination at any time - suitable for the current compressed air consumption - with proven lower costs and wear of the compressors. Several studies have shown that the costs for compressed air generation are up to 30% higher than they should be. About 10% of the energy in the industry is used for compressed air generation with an increasing demand. AIRLEADER - is self-learning - with automatic optimisation - is easy to handle - monitors the compressed air station - informs on service and fault messages Compressed air is an important matter. Thus, in more than 20 years of planning and sales of compressor stations, the demands of the compressed air users have been compiled and have been realised in the new series AIRLEADER Professional. AIRLEADER - shows the current compressed air consumption - keeps the pressure constant - monitors the pressure dew point - integrates the frequency-controlled compressor - dynamises the process of the compressed air stations The costs for compressed air generation are being reduced by up to 27% when AIRLEADER reduces the load kw costs up to 20%, the idle running kw costs up to 99%, the wear with the compressors by more than 50%and the service costs by 30%. Compressor-Management is the first step of a program for saving compressed air costs.

3 1. Expansions at the AIRLEADER controller 1. an operating system is played into the controller. The program flow only is on the Eprom 2. optimizing the compressor combinations dynamically and automatically by 8 selflearning calculation processes adapted to the real air consumption. For lower energy costs 3. Dynamicly compressor changings at equally compressors without pressure drop within the pressure band 4. active processing of the analog signal of the various speed regulatedcompressor 5. free programmable maximum regulation range for speed regulated compressor 6. free programmable minimal regulation range for speed regulated compressor 7. direct switching on further compressors in the pressure band if production needs more compressed air 8. direct switching off compressors within the pressure band if the speed regulated compressor has reached its minimal regulation range 9. Analog output for the external pressure advertisement over the pressure area 10. Analog output for the external compressed air consumption advertisement 11. Analog input for the supervision of the pressure dewpoint or room temperature 12. Alarm report when dewpoint or pressure, over or underrun the limited values 13. Dewpoint at the display (press + button) 14. 30 times faster communication between AIRLEADER the PC and Master-Slave 2. Expansions at the PC Program 1. Windows 2000 and WINDOWS XP fit 2. Dewpoint diagram to show the damp in the compressed air 3. Compressed air consumption, pressure and pressure dewpoint 4. advertisement in numbers in every view 5. Compressors status advertisement for every view in the status strip 6. Zoom lens areas 1, 3, 6 12 24 hours 7. Alarm and service report supervises service intervals and writes events like service transgression and disturbing reports in the monthly report

4 1. Compressor-Management-System AIRLEADER combines compressors of different sizes to an optimum unit which automatically adapts to the production based on the current compressed air consumption. It is made sure that it is always the most efficient compressor combination which generates the compressed air necessary for production, independent of the manufacturer and the performance. The system pressure remains within the smallest limits. It is seen that the costs are kept as low as possible. The compressor performances and a common pressure difference are programmed in for all the compressors. Based on this information, AIRLEADER permanently calculates the current compressed air consumption and the volume of the compressed air system. The self-learning 8-fold calculation depth makes it possible to adapt the compressors to the changes in consumption in a dynamic way. Automatic compressor change as per compressed air consumption: If all the compressors are on the same rank, they are working fully automatically and based on consumption. The priority of the compressors is adapted to the production process in real time and with a useful hysterisis calculation. It is always the compressor combination with the lowest cycle rates which is running and thus with the lowest idle times. Big compressors are only running when needed. The smaller compressors are running under load instead of idling with the big compressors. The compressors auto-regulate the motor start limitations. The speed-controlled compressor is actively integrated The speed-controlled compressor transmits the information on the motor speed via its analogous output. Parameterisation is effected as to the minimum and maximum quantity delivered in the AIRLEADER. The analogous signal allows to continuously add further compressors with higher consumption and to remove them with lower consumption using programmable control limits. If desired, switching over is effected automatically to a normal compressor with a very low compressed air consumption. Manual priorities The priority menu allows the compressors to work on different priority levels. Compressors with a different size having the same priority then work again based on consumption. This function is frequently used for reserve compressors or for compressors with heat recovery.

5 2. Additional control functions Compressor running time compensation For compressors with the same performance, a change time for the same operating hours can be programmed when they are on the same priority. Each compressor performance group can be programmed using a different change time. The change is effected taking the motor running times into account. If a compressor has reached the programmed time difference to the compressor with the lowest time in the same performance group, the compressors are exchanged without any pressure loss within the pressure range. The real time switch with multifunction has the following functions: - Switch the compressors ON at production start and OFF at production end - 3 programmable pressure profiles for pressure increase and pressure reduction - switch 3 different manual priorities dependent on the time - switch 2 additional devices such as dryer or valves ON/OFF 3. Compressor inputs The status of the compressors is constantly monitored. If a running compressor displays a malfunction within the pressure range or is switched off for service, its performance is taken over by other compressors. If several compressors are needed to do this, addition is made time-delayed. Load and total running times are stored for the individual compressors. The operating hours are deleted, if required. 4. Information on the user display The following information is permanently shown on the display: # Compressed air consumption in m³/min # current system pressure in bar # Pressure dew point in C (at the click of a button) Compressor status is displayed with the three-colour LEDs: green Compressor conveys yellow Compressor is idling red Compressor displays a malfunction red blinking Compressor is switched off LED off Compressor is ready for use 5. Programming Programming is effected using 4 keys Enter key opens programming and confirms it Cursor scrolls within the menus + key increases the value - key reduces the value

6 6. Digital inputs and outputs Digital inputs for: 1. START/STOP of the compressors externally 2. Programming release 3. Time switch activation 4. second pressure profile or second priority Digital outputs for: 1. Minimum pressure and malfunction of unit as well as exceeding of dew point 2. Collective fault compressors 3. two time switch outputs for switching of additional devices such as dryer, filter etc. 7. Analogous inputs and outputs Analogous inputs 4-20 ma for: 1. Pressure transmitter for pressure monitoring (Standard 0-16 bar) 2. Signal of speed-controlled compressor via speed 3. Monitoring of ambient temperature or compressed air humidity using the dew point sensor Analogous outputs 4-20 ma for: 1. Pressure range over the range preset by the pressure transmitter 2. Compressed air consumption in m³/min up to the maximum performance of the compressors 8. Scope of delivery of Hardware Triggering of the compressors is effected using the relay cards supplied with potential free change-over contact. Each compressor informs of its status such as motor running, malfunction and readiness for use via contacts. AIRLEADER Relay card Transmitter RS-485 in metallized housing for wall mounting for every compressor (top hat rail mounting in compressor control cabinet) for the current pressure detection with analogous output 4-20 ma serial interface for PC und Master-Slave connection

Technical details and list of equipment AIRLEADER Professional 2 4 8 Master 4 Master 8 Slave 2 Slave 4 Slave 8 Number of compressor connections 2 4 8 4 8 2 4 8 Number of controlled compressors 2 4 8 8 16 2 4 8 Compressor LED for -LOAD,-IDLING,-MALFUNCTION 2 4 8 8 16 2 4 8 Inputs for compressor fault messages 2 4 8 4 8 2 4 8 Inputs for motor running messages of compressor 2 4 8 4 8 2 4 8 Inputs for readiness for use of compressor 2 4 8 4 8 2 4 8 Interface relay cards for compressor control 2 4 8 4 8 2 4 8 Control compressors by compressed air consumption Series Series Series Series Series Common pressure difference for all compressors Series Series Series Series Series Programming management via display Series Series Series Series Series Connection of a frequency-controlled compressor Optional Series Series Series Series Connection of a sensor for dew point or ambient temperature optional Series Series Series Series Manual setting of compressor priorities Series Series Series Series Series Pressure transmitter supply Series Series Series Series Series Remote ON/OFF Series Series Series Series Series Operating/fault message LED green/red green/red green/red green/red green/red Minimum pressure and device malfunction output 24VDC 1 1 1 1 1 Compressor fault message output 24VDC - 1 1 1 1 Multi function time switch for: 3 pressure profiles, -3 compressor priorities control system ON/OFF, 2 switching outputs for triggering of Series Series Series Series Series additional devices (e. g. dryer or automatic actuators etc.) 7 Via master control Via master control Via master control Interface RS 485 for PC and Slave connection Series Series Series Series Series Series Series Series We reserve the right to technical modifications Technical data: Mains voltage 230 V AC 50 Hz Compressor performance 0.1-200 m³/min OPTION: CFM Pressure range 0-16 bar OPTION: 0 2.5 bar 0 50 bar 0 400 bar Vacuum 0 to -1 bar Minimum pressure difference 0.3 bar OPTION: 0.03 bar Inputs and outputs 24 V DC Cable ducts Thread M 16 x 1.5

8 AIRLEADER Professional Compressed Air Visualisation + with SERVICE and ALARM Report + 1. Compressed air visualisation The PC program Compressed air transparent records the control process up to one second. At any time, it is possible to persuade oneself of the fact that the compressed air volume necessary for production is generated by the suitable compressor combination. Different diagrams show the efficiency of compressed air generation. The integrated calculation program lists the running times of the compressors as to load and idle times and calculates the energy consumption. The capacity and the work load of the compressors compared to the energy used gets more transparent. This make a more detailed cost control of the compressed air generation possible. 2. Diagrams in the Online view # Compressed air consumption diagram in m³/min # Pressure diagram in bar # Pressure dew point diagram in C DTP # Total diagram for compressed air consumption, pressure and compressor status # Diagram of the current capacity of the speed-controlled compressor The status line displays the current status of the compressor in the form of a symbol # green = Load # yellow = Idle running # red = Fault # blue = not ready In addition, the compressed air consumption, the pressure and the pressure dew point are shown with digits in the diagram views. (dew point only if a dewpoint sensor is connected) 3. Diagrams in the daily evaluation view # Compressed air consumption diagram in m³/min # Pressure diagram in bar # Pressure dew point diagram in C DTP # Total diagram for compressed air consumption, pressure and status of compressors # Capacity of the speed-controlled compressor # Load time, idle time, fault message of compressors switched off for service # Efficiency diagram as per load and idle running Kilowatt # Energy calculation table with compressed air consumption data Zoom range 1, 3, 6, 12, 24 hours, for the graphical diagrams 4. Diagrams in the weekly evaluation view # Compressed air consumption diagram in m³/min up to 7 days in different colours # Energy calculation table with compressed air consumption data # Efficiency diagram as per load and idle running Kilowatt # Energy calculation table with compressed air consumption data The data for the evaluation can be stored weekly, monthly, quarterly or annually.

9 5. service and alarm report The running hours of the compressors for load and idle running are written down on the service mask. For every channel at the AIRLEADER, there are 4 freely definable ways of services as time intervals will certainly. After programming the compressor running times and the different service intervals the entered times belong backward to 0. Is this report is gone off a time taken on time exactly in the monthly report. The number counts go into minus and will show red. A service warning appears on the screen. Interval can respectively one by one moved back by the "R" button (Resetbutton) on the before oriented interval times If a compressor or additional equipment goes on fault status also is taken on this monthly report and an alarm warning appears on the screen. By the fault reports piling themselves up damages become at the compressors and production plants (by damp compressed air), recognized early. The open monthly report in table representation will help. 6. service input mask

10 AIRLEADER Professional ALARM + SERVICE REPORT + shows alarm messages + shows service messages + AIRLEADER Compressor-Management Alarm + Service-Report FEBRUARY 2003 complete events NAME OF CUSTOMER alarm messages service messages date daily events time compressor 1 compressor 2 compressor 3 compressor 4 compressor 5 refr. dryer 1 refr. dryer 2 filter pressure room temperatur dewpoint compressor 1 compressor 2 compressor 3 compressor 4 compressor 5 refr. dryer 1 refr. dryer 2 filter 1 11.02.03 1 10:23:15 X X 2 11.02.03 2 11:54:12 X X X X 3 11.02.03 3 16:14:30 X X X X 4 12.02.03 1 06:18:20 X X 5 12.02.03 2 08:37:45 X X X X 6 12.02.03 3 12:34:20 X X 7 12.02.03 1 22:25:23 8 14.02.03 1 04:46:02 X 9 14.02.03 2 22:12:06 10 19.02.03 1 04:45:06 X X X 11 19.02.03 2 05:02:26 X 12 19.02.03 3 05:06:30 13 20.02.03 1 04:45:10 X X X X 14 20.02.03 2 04:46:43 X X 15 20.02.03 3 06:12:33 X 16 21.02.03 1 22:03:45 X 17 22.02.03 1 04:05:08 X 18 24.02.03 1 04:44:07 19 24.02.03 2 04:45:13 X 20 24.02.03 3 05:03:55 X 21 24.02.03 4 22:12:40 X X X 22 24.02.03 5 04.40:05 X 23 24.02.03 6 04:05:10 24 24.02.03 7 05:11:45 X X 25 25.02.03 1 04:47:36 X 26 25.02.03 2 04:47:56 X X 27 25.02.03 3 12:30:10 X 28 25.02.03 4 16:14:09 29 28.02.03 1 04:46:13 30 28.02.03 2 16:32:27 X 31 32 33 34 35 36 37 38 39 40 41 42 43

11 AIRLEADER Professional ALARM and SERVICE MANAGEMENT + informs on fault messages + monitors service intervals + 1. The compressed air station communicates automatically The ALARM and SERVICE MANAGEMENT is closely working together with the PC program Compressed air transparent. Fault messages as well as service messages are stored. Upon activation of the transmitting function, the messages are transmitted via modem or Fritz-Card to fax machines, via e-mail or as short message via SMS to mobile phones. The fault messages and service messages of the compressors and additional devices are recorded up to one second and are stored in the monthly report for alarm and service. Frequently available fault messages allow to determine damages with compressors and production plants at an early time (using humid compressed air). The clear monthly report in tabular form is a real help. 2. ALARM messages The compressors connected to the fault inputs of AIRLEADER are stored and actively processed. The remaining free inputs allow for the connection of fault messages of filters, Bekomates, refrigeration dryer/adsorption dryer. 3. SERVICE messages With commissioning of the ALARM and SERVICE MANAGEMENT, the total hours and load hours of the compressors are initially programmed. The times thus accumulated are updated every 60 minutes. The intervals of up to 4 freely definable items, such as air filter / oil filter / oil separator / and oil change can be freely determined. 4. Monthly report for ALARM and SERVICE messages The alarm and service messages are stored in a monthly file. With every new message, the monthly file is sent in tabular form to the address defined before by fax or e-mail. The events are continuously numbered and added with date and time and stored one below the other. In the course of the day, the events are additionally numbered. The monthly report can be printed out at any time using the print menu. 5. Sending of messages # Monthly report via fax # Monthly report via e-mail # Short message via SMS The following selection functions can be determined: # Alarm and/or service message # 2 different fax configurations with 3 different fax numbers each # 2 different e-mail configurations with 3 different fax numbers each # 2 different SMS configurations with 3 different fax numbers each 5. Monitoring of analogous inputs # Min Max message with exceeding or not reaching the pressure # Min Max message with exceeding or not reaching the dew point # Monitoring of the capacity of the speed-controlled compressor

12 5. Monitoring of analogous inputs

Scope of supply to the AIRLEADER Professional upgrade (Articlegroupe 20) 13 For AIRLEADER Type 0201, 0401, 0801, 1401, 1801 Witch PC-Programm was delivered - Control-program for AIRLEADER in form of an EPROM s - EPROM change tool - assembly instructions - visualizations program Update on CD-ROM with Service and Alarm Report - operation manual for AIRLEADER and PC-Programm - connection of VSD compressor or dewpoint sensor for AIRLEADER 2 Für AIRLEADER Typ 0201, 0401, 0801, 1401, 1801 For still no PC-Program was delivered - Control-program for AIRLEADER in form of an EPROM s - EPROM change tool - assembly instructions - visualizations program as full version on CD-ROM with Service and Alarm Report - operation manual for AIRLEADER and PC-Programm - connection of VSD compressor or dewpoint sensor for AIRLEADER 2 AIRLEADER 2 AIRLEADER 4 AIRLEADER 8 and Master 4 AIRLEADER MASTER 8 240,-- 400,-- 540,-- 860,-- AIRLEADER 2 AIRLEADER 4 AIRLEADER 8 and Master 4 AIRLEADER MASTER 8 360,-- 540,-- 680,-- 980,-- Additional products for the AIRLEADER Professional UPGRADE: DEWPOINT SENSOR, measuring range -50 bis +30 C DP, pressure max 70 bar with 4-20 ma Analog output 660,-- ALARM and SERVICE-MANAGEMENT In connection with Visualization PC-programm and modem or Fritz-Card. Messages for alarm and services to Fax, -e-mail, -SMS. Monthly alarm and service reports. Adjustable intervalls for airfilter,- oilfilter, - 460,-- oilseparator, oil changing time for compressors. A minimum and maximum alarm limit can be set to the dewpoint Interface - RS485<>RS232 to connect AIRLEADER RS485 210,-- to PC. Incl. DB-9 cable and power supply Ethernet interface - RS485<>Ethernet with RJ45 connection to computer networks. Freely definable TCP/IP address. Incl. communikation software for virtual COM-Port and power supply All prices FOB factory excludet packaging costs. The products remains our property until the complete payment. We only accept conditions of the german electric industries We reserve to the right to make tecnical changes and improvements without notice at any time 410,--