Fitting / Mise en place / Colocación / Ajuste

Similar documents
Fitting / Mise en place / Colocación / Ajuste

User guide English r1 Quattro Air Amer Multi Multi Book.indb 1 14/07/ :30:10 AM

Quattro Air Non-vented full face mask

Mirage FX. User Guide. English NASAL MASK

AirFit Nasal Mask. User guide N10. English

English USER GUIDE User guide

Mirage Micro. User Guide. English. nasal mask

English USER GUIDE User guide

Mirage FX. User Guide. English NASAL MASK

Swift LT NASAL PILLOWS SYSTEM. User Guide English

Full face mask. User guide English

User Guide. English. Nasal Pillows System

Full face mask. User guide. English

User Guide. English. Nasal Pillows System

Quattro FX Quattro FX for Her

Mirage Vista Nasal Mask

Mirage Micro for Kids. nasal mask

Hospital masks. User guide. English

English. ivolve Full Face Mask. User Manual

Mirage Quattro FULL FACE MASK

Nasal mask. User guide. User guide English

Mirage FX. User Guide. English NASAL MASK

Swift FX Nano Swift FX Nano for Her

Mirage Micro for Kids

User guide English book.indb 1 14/07/ :51:19 AM

Mirage Micro. User Guide. English. nasal mask

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Mirage Quattro FULL FACE MASK

AirFit Nasal Mask. User guide N10. English

Mirage FX. User Guide. English NASAL MASK

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR NASAL PILLOWS SYSTEM

Quattro FX Quattro FX for Her

Mirage Liberty. User Guide 61850/ APAC ENG MIRAGE LIBERTY USER r2 cover.qxp 3/04/2007 4:39 PM Page 1. English FULL FACE MASK

Instructions for Use. OptiLife Nasal Lab Mask

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

Full face mask. User guide. English

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Swift FX Nano Swift FX Nano for Her

Invacare Twilight II Nasal Mask

ComfortGel Full. Full Face Mask

Full face benefits in a compact size

EasyFit SilkGel Full Face Mask

Mirage Activa LT. User Guide. English. nasal mask

Pixi. User Guide. Pixi TM PEDIATRIC MASK. English. pediatric MASK

EasyFit Full Face Mask, Silicone EasyFit Full Face Mask, Gel

Ultra Mirage II Nasal Mask

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

English Please read the entire Information and Welcome Guides before using your device.

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

English Please read the entire Information and Welcome Guides before using your device.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Full face mask. QuietAir. User guide. English

Contents Warnings, Cautions, and Notes Contents of the Package Introduction to the Harmony S/T A Tour of the Harmony S/T...

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Please read the entire Information and Welcome Guides before using your device.

Oxygen Dialflow Meter. Instructions for Use

Pressure Regulator. Instructions for Use

Rev. B. Operating Instructions

Model 1700 Patient Operating Instructions. Model 1700

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Micro Dial-Flowmeter. Instructions for Use

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

M5400 Operators Manual

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Full face mask. User guide. English Deutsch Français Italiano العربیةاللغة Nederlands

Dialflow Regulator. Instructions for Use

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

RG2200 BC Integrated Octopus

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

CPR MEDICAL DEVICES INC. OPERATING MANUAL

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

AUTOVENT 4000 VENTILATOR

User guide User guide English

Oxygen Dialflow Meter. Instructions for Use

Oxygen Demand Valve. Instructions for Use

Log on now to to find useful tips on managing your treatment. Mirage Swift II. Nasal Pillows System. User Guide.

User manual STARLOCK. Careways International - Innovation Quality Performance

RG3100 and RG3100Ice Regulator System

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

SOTR Special Operations Tactical Respirator

Paradise Pump Series Operator s Manual

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

Read Instructions carefully before use. Rollator is designed for indoor & outdoor use. Do NOT use as a wheelchair or as a transport chair.

Model ASSEMBLY and OPERATING INSTRUCTIONS

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

User guide User guide English

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Bimini Top, Bimini Top Plus for Jeep Wrangler Vehicles Items # , # and #

TactAir PCP Fill Kit/Adapter. Operation Manual

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

Transcription:

User Guide English

Fitting / Mise en place / Colocación / Ajuste 1 2 3 4 5 6 7 8

Removal / Retrait / Remoción / Remoção 1 2 Disassembly / Démontage / Desmontaje / Desmontagem 1 2 3 4 5

Reassembly / Remontage / Montaje / Remontagem 1 2 3 4 5

ENGLISH Full face mask Thank you for choosing the AirFit F10. This document provides the user instructions for the AirFit F10 and AirFit F10 for Her masks referred to collectively as AirFit F10 throughout this manual. AirFit F10 has blue headgear while AirFit F10 for Her has pink headgear. Using this guide Please read the entire guide before use. When following instructions, refer to the images at the front and back of the guide. Intended Use The AirFit F10 is a noninvasive accessory used for channeling airflow (with or without supplemental oxygen) to a patient from a positive airway pressure (PAP) device such as a continuous positive airway pressure (CPAP) or bilevel system. The AirFit F10 is: to be used by patients (weighing >66 lb (30 kg)) for whom positive airway pressure therapy has been prescribed intended for single-patient reuse in the home environment and multipatient reuse in the hospital/institutional environment. GENERAL WARNINGS The mask must be used under qualified supervision for users who are unable to remove the mask by themselves. The mask may not be suitable for those predisposed to aspiration. The elbow and valve assembly have specific safety functions. The mask should not be worn if the valve is damaged as it will not be able to perform its safety function. The elbow should be replaced if the valve is damaged, distorted or torn. The vent holes must be kept clear. The mask should only be used with CPAP or bilevel devices recommended by a physician or respiratory therapist. English 1

The mask should not be used unless the device is turned on. Once the mask is fitted, ensure the device is blowing air. Explanation: CPAP and bilevel devices are intended to be used with special masks (or connectors) which have vent holes to allow continuous flow of air out of the mask. When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask holes. When the device is turned off, the mask valve opens to atmosphere allowing fresh air to be breathed. However, a higher level of exhaled air may be rebreathed when the device is off. This applies to most full face masks for use with CPAP and bilevel devices. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the CPAP or bilevel device is not operating, so that unused oxygen does not accumulate within the device enclosure and create a risk of fire. Oxygen supports combustion. Oxygen must not be used while smoking or in the presence of an open flame. Only use oxygen in well ventilated rooms.at a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate. This warning applies to most types of CPAP or bilevel devices.the technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the CPAP or bilevel device function. Discontinue using this mask if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist. Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental condition. If symptoms occur, consult your physician or dentist. As with all masks, some rebreathing may occur at low CPAP pressures. Refer to your CPAP or bilevel device manual for details on settings and operational information. Remove all packaging before using the mask. 2

Using your mask When using your mask with ResMed CPAP or bilevel devices that have mask setting options, refer to the Technical specifications section in this user guide for mask selection options. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative. Use a standard conical connector if pressure readings and/or supplemental oxygen are required. Fitting 1. Remove the elbow from the mask by pressing the side buttons and pulling the elbow away. 2. With both lower headgear straps released, hold the mask against your face and pull the headgear over your head. Ensure that the label on the back of the headgear faces outwards when the headgear is put on. 3. Undo the fastening tabs on the upper headgear straps. Pull the straps evenly until the mask is stable and positioned as shown in the illustrations. Reattach the fastening tabs. 4. Bring the lower straps below your ears and loop the headgear into the lower hooks on the frame. 5. Undo the fastening tabs on the lower headgear straps. Pull the straps evenly until the mask sits firmly on the chin and reattach the fastening tabs. 6. Connect the air tubing from your device to the elbow. Attach the elbow to the mask by pressing the side buttons and pushing the elbow into the mask. Turn on your device so that it is blowing air. 7. Undo the fastening tabs on the upper headgear straps. Readjust the straps evenly only enough that a seal is achieved and reattach the fastening tabs. Overtightening may cause leaks. 8. Your mask and headgear should be positioned as shown. Removing your mask 1. Disconnect one or both of the lower headgear straps from the hook. 2. Pull the mask away from your face and back over your head. English 3

Disassembly 1. Unhook the upper headgear straps from the frame. There is no need to undo the fastening tabs. 2. Remove the elbow from the mask by pressing the side buttons and pulling the elbow away. Remove the elbow from the air tubing. 3. While holding the bottom of the hook, pull the corner of the frame slightly away from the side of the mask. 4. Remove the frame from the rest of the mask. 5. If the soft sleeves are fitted, remove them by pulling them off of the frame. Reassembly 1. Press the top of the frame onto the rest of the mask, ensuring it clicks into place. 2. Press the bottom corners of the frame onto the rest of the mask, ensuring they click into place. 3. To fit the optional soft sleeves, pull them over the upper arms of the frame. 4. Attach the top headgear straps to the frame by looping through each of the upper headgear hooks. Ensure that the ResMed logo on the headgear is facing outward and right side up. 5. Attach the elbow to the air tubing. Attach the elbow and air tubing to the mask by pressing the side buttons and pushing the elbow into the mask. Pull on the elbow to check that it sits securely in the mask. Cleaning your mask in your home Your mask and headgear should only be handwashed by gently rubbing in warm (approximately 86 F/30 C) water using mild soap. All components should be rinsed well with drinking quality water and allowed to air dry out of direct sunlight. WARNING Always follow cleaning instructions and use mild soap. Some cleaning products may damage the mask, its parts and their function, or leave harmful residual vapours that could be inhaled if not rinsed thoroughly. 4

CAUTION If any visible deterioration of a system component is apparent (cracking, discoloration, tears etc.), the component should be discarded and replaced. Daily/After each use: Disassemble the mask components according to the disassembly instructions. Handwash the separated mask components (excluding headgear and soft sleeves). To optimize the mask seal, facial oils should be removed from the cushion after use. Use a soft bristle brush to clean the vent. Inspect each component and, if required, repeat washing until visually clean. Rinse all components well with drinking quality water and allow to air dry out of direct sunlight. When all components are dry, reassemble according to the reassembly instructions. Weekly: Handwash the headgear and soft sleeves. Reprocessing the mask between patients This mask should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, www.resmed.com/masks/sterilization/americas. If you do not have internet access, please contact your ResMed representative. English 5

Troubleshooting Problem/possible cause Mask is uncomfortable Headgear straps are too tight. Mask could be the wrong size. Mask is too noisy Elbow incorrectly installed. Vent is blocked or partially blocked. Mask leaks around the face. Cushion membrane is creased or folded. Mask could be the wrong size. Frame incorrectly fitted. Solution The cushion membrane is designed to inflate against your face to provide a comfortable seal with low headgear tension. Adjust straps evenly. Ensure that the headgear straps are not too tight and that the cushion is not crushed or creased. Talk to your clinician to have your face size checked against fitting template. Note that sizing across different masks is not always the same. Remove the elbow from your mask, then reassemble according to the instructions. Clean with a soft bristle brush until the vent is clear. Refit your mask according to the instructions. Ensure that you position the cushion correctly on your face before pulling headgear over your head. Do not slide the mask down your face during fitting as this may lead to folding or curling of the cushion. Talk to your clinician to have your face size checked against fitting template. Note that sizing across different masks is not always the same. Remove the rest of the mask from the frame, then reassemble according to the instructions. 6

Technical specifications Pressure-flow curve Dead space information Therapy pressure Resistance with Anti Asphyxia Valve (AAV) closed to atmosphere Inspiratory and expiratory resistance with Anti Asphyxia Valve (AAV) open to atmosphere Anti Asphyxia Valve (AAV) open-to-atmosphere pressure Anti Asphyxia Valve (AAV) closed-to-atmosphere pressure The mask contains passive venting to protect against rebreathing. As a result of manufacturing variations, the vent flow rate may vary. Pressure (cm H2O) Flow (L/min) 3 19 4 22 8 32 10 37 12 41 16 48 20 54 24 60 28 66 30 69 32 72 36 77 40 82 Physical dead space is the empty volume of the mask to the end of the swivel. Using the large cushions it is <222 ml. 3 to 40 cm H2O Drop in pressure measured (nominal) at 50 L/min: 0.2 cm H2O at 100 L/min: 0.9 cm H2O Inspiration at 50 L/min 0.6 cm H2O Expiration at 50 L/min 1.0 cm H2O 1.6 cm H2O 1.8 cm H2O English 7

Environmental conditions Gross dimensions Mask setting options Operating temperature: 41 F to 104 F (+5 C to +40 C) Operating humidity: 15% to 95% non-condensing Storage and transport temperature: -4 F to 140 F (-20 C to +60 C) Storage and transport humidity: up to 95% non-condensing Extra Small: 4.61" (H) x 5.59" (W) x 5.67" (D) (117 mm (H) x 142 mm (W) x 144 mm (D)) Small: 4.69" (H) x 5.59" (W) x 5.67" (D) (119 mm (H) x 142 mm (W) x 144 mm (D)) Medium: 5.39" (H) x 5.75" (W) x 5.59" (D) (137 mm (H) x 146 mm (W) x 142 mm (D)) Large: 5.51" (H) x 5.75" (W) x 5.59" (D) (140 mm (H) x 146 mm (W) x 142 mm (D)) Mask fully assembled with elbow assembly (no headgear) For S9: Select 'Full Face' For other devices: Select 'MIR FULL' (if available), otherwise select 'FULL FACE' as the mask option. Notes: The mask system does not contain PVC, DEHP or phthalates. This product is not made with natural rubber latex. The manufacturer reserves the right to change these specifications without notice. Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a dry place out of direct sunlight. Disposal This mask does not contain any hazardous substances and may be disposed of with your normal household refuse. 8

Symbols The following symbols may appear on your product or packaging: Catalog number Batch code Humidity limitation Temperature limitation Fragile, handle with care Not made with natural rubber latex Manufacturer European Authorized Representative Keep away from rain This way up Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Caution, consult accompanying documents Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician) English 9

Limited warranty ResMed Ltd (hereafter ResMed ) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke. Warranty is void on product sold, or resold, outside the region of original purchase. Warranty claims on defective product must be made by the initial consumer at the point of purchase. This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office. 10

Mask components AirFit F10 AirFit F10 for Her A Elbow / Coude / Codo / Cotovelo 1 Valve / Valve / Válvula / Válvula 2 Side buttons / Boutons latéraux / Botones laterales / Botões laterais B Frame / Entourage rigide / Armazón / Armação 3 Lower headgear hooks / Crochets inférieurs du harnais / Ganchos inferiores del arnés / Ganchos inferiores do arnês 4 Upper headgear hooks / Crochets supérieurs du harnais / Ganchos superiores del arnés / Ganchos superiores do arnês C Cushion / Bulle / Almohadilla / Almofada 63137 (XS/S) 63138 (M/L) 62737 (S) 62738 (M) 62739 (L) 5 Vent / Orifice de ventilation / Ventilación / Respiradouro D Headgear / Harnais / Arnés / Arnês 63165 (S) 63164 (Std) 63166 (L) 6 Lower headgear straps / Sangles inférieures du harnais / Correas inferiores del arnés / Correias inferiores do arnês 7 Upper headgear straps / Sangles supérieures du harnais / Correas superiores del arnés / Correias superiores do arnês 63137 (XS/S) 63138 (M/L) 62736 (XS) 62737 (S) 62738 (M) 63167

A+B+C Frame system / Entourage complet / Sistema de armazón / Sistema da armação 8 Soft sleeves / Gaines souples / Fundas blandas / Mangas maleáveis A+B+C+D Complete system / Système complet / Sistema completo / Sistema completo AirFit F10 63161 (S) 63162 (M) 63163 (L) 63101 (S) 63102 (M) 63103 (L) AirFit F10 for Her 63160 (XS) 63161 (S) 63162 (M) 63139 (XS) 63140 (S) 63141 (M) XS: Extra Small / Très Petit / Extra Pequeña / Extra Pequena S: Small / Petit / Pequeña / Pequena M: Medium / Médium / Mediana / Médio L: Large/ Large / Grande / Grande Std: Standard / Standard / Estándar / Padrão

A B C D 1 2 3 4 5 6 7 8 AirFit F10 for Her ResMed Ltd 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153 Australia See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip. AirFit is a trademark of ResMed Ltd. 2017 ResMed Ltd. 628059/3 2017-07 628059 ResMed.com