Standard Operating Procedure

Similar documents
Quenching of Self-Heating Substances and Mixtures

Quenching of Self-Heating Substances and Mixtures

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

Chemical Class Standard Operating Procedures. Pyrophoric Chemicals (PYR) & Water Reactive Chemicats (WRC) Diethylzinc

Hydrogen Cyanide (HCN)

Pyrophoric Materials (PYR)

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Self-Heating Substances and Mixtures H251 H252

Chemical Class Standard Operating Procedures

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

Corrosives- Strong Bases

Chemical Class Standard Operating Procedures

Laboratory Standard Operating Procedure: Cryogenic Liquids

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Standard Operating Procedure

Laboratory Standard Operating Procedure: Sensitizers

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Laboratory Standard Operating Procedure: Carcinogens

General Safety Rules

Laboratory Standard Operating Procedure: Acutely Toxic Substances

Standard Operating Procedure for Solvent use in EMAL

Laboratory Standard Operating Procedure: Reproductive Toxins

Hydrofluoric Acid SOP

The Safe Use of Pyrophoric Substances

Hydrofluoric Acid. Strong Corrosives Strong Acids (SA) & Acutely Toxic Chemicals (ATC)

SAFE. Introductionn. (H2SO4) with. Investigator/ Any accident. to EH&S. Hazards National Fire. Health 4 Flammability Reactivity 2 Special Hazard

Laboratory Standard Operating Procedure: Specimen Preservatives

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Standard Operating Procedure (SOP)

13 Listed Carcinogens

STANDARD OPERATING PROCEDURE TEMPLATE

Standard Operating Procedure

1. The Safe Use of Pyrophoric Reagents

Standard Operating Procedure

Standard Operating Procedure (SOP)

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Working Safely with Hydrofluoric Acid

Acutely Toxic Gases (ATGs)

Laboratory Standard Operating Procedure: Irritants

Department of Chemistry

Standard Operating Procedure

University of Saskatchewan Department of Mechanical Engineering Standard Operating Procedure # Mat0002

Developing Safety Guidelines for Cryogenic Liquids.

Safe Use of Solvent Stills

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

Compressed Gases STANDARD OPERATING PROCEDURE

Chemical Spill Clean-up Protocol

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

Standard Operating Procedure

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Chemical Hygiene Plan

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

LABORATORY SAFETY INSPECTION

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

The health hazards of HF are dependent upon the concentration, temperature and nature of exposure.

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

LABORATORY SAFETY. A general overview

1. Safety glasses are to be worn at all times in the laboratory except in the study area adjacent to the lab.

UCSC Laboratory Standard Operating Procedure (SOP) Compressed Gas Cylinder Change for MOCVD and CVD Systems

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

MATERIAL SAFETY DATA SHEET

Personal Protective Equipment

Instructions for completing the Unit Operations Lab safety inspections using the Safety Inspection Checklist

SOP Standard Operating Procedure. Etching All Materials

School of Chemistry SOP For Operation Of Glove Boxes

SAFETY ORIENTATION. University of Evansville Department of Chemistry

Chemical Class Standard Operating Procedures

Standard Operating Procedure

Standard Operating Procedure

Carnegie Mellon University. Toxic and Highly Toxic Gas Handling Program

Laboratory Safety Training. Environmental Health and Safety

Material Safety Data Sheet

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Date: Review Date: Assessment Reference: Experiment or Procedure (include a brief description, including equipment used and frequency of exposure):

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

PURPOSE OF THE POLICY

Environmental Health and Public Safety. Graduate Student Safety Training

Faculty of Biological Sciences Assessment Title SDS-PAGE Gel Electrophoresis preparation of gels Area/Service Protein Production Facility

MATERIAL SAFETY DATA SHEET

Safety Data Sheet Vanilla Fresh

Date Printed: 23/JUL/2007 Date Updated: 12/FEB/2006 Version 1.3 Regulation (EC) No 1907/2006

MATERIAL SAFETY DATA SHEET

Standard Operating Procedure (SOP) for ( Sodium Hydroxide )

Guide to Safety in the Science Classroom

1. Substance Information

Molecular Materials Research Center Beckman Institute California Institute of Technology

Environmental Health and Public Safety. Graduate Student Safety Training

Parallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL!

Yeo Soh Bee A/Prof Dan Yock Young 28/03/2016 Prepared by Approved By Issue Date

University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET Loxeal Grasso 9

Material Safety Data Sheet acc. to ISO/DIS 11014

Laboratory Safety Inspection Checklist

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Safety Issues in Healthcare Programs / Healthcare Employment

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

Transcription:

Standard Operating Procedure Read the EH&S Standard Operating Procedures Fact Sheet before filling out this form. Print out the completed form and keep a readily accessible hard copy in the lab (also keeping an electronic copy is highly recommended). Date: 3/05/2010 SOP Title: Principal Investigator: Hydrogenations Using Heterogeneous Catalysts Richmond Sarpong Room and Building: Latimer 847 Lab Phone Number: 3-2485 Section 1 Process Section 2 Hazardous Chemicals A variety of organic solvents can be used in hydrogenations, each with their own safety and health risks. Please consult the MSDS database for more information. Palladium on carbon is a highly flammable finely divided metal. Section 3 Potential Hazards Hydrogenation reactions pose a significant fire hazard due to the use of flammable solvents. The presence of hydrogen gas increases the risk of explosion. Section 4 Approvals Required Performing a hydrogenation reaction requires training and the approval of the appropriate lab member. Section 5 Designated Area This procedure should be performed in a fume hood in good working condition.

Section 6 Special Handling Procedures and Storage Requirements Palladium on carbon (Pd/C) frequently ignites when it first comes in contact with methanol (and to a lesser extent, any flammable organic solvent) and as such represents a significant safety risk. These procedures are recommended whenever Pd/C is used in conjunction with hydrogen gas. Hydrogenation using a balloon: 1) Evacuate the reaction vessel (this should have at least two openings) and backfill with an inert gas (nitrogen or argon). 2) Weigh out the desired amount of Pd/C and transfer into the reaction flask under an inert atmosphere. 3) Add a small amount of ethyl acetate, dichloromethane, or toluene to the reaction flask, making sure to wash down any Pd/C stuck to the flask walls. All the Pd/C should be submerged at this point. 4) Carefully add methanol or other solvent by creating a stream down the side of the flask wall. 5) Add the reaction substrate either as a solution or neat. 6) Begin stirring the reaction mixture and then evacuate the flask just until the solvent begins to bubble, then carefully backfill with inert gas. 7) Repeat step 6 twice more. 8) Attach a balloon of hydrogen to your flask with an adapter that allows the balloon to be closed off from the reaction flask. 9) With the hydrogen balloon closed off, evacuate the flask until the solvent begins to bubble, and then open the balloon to the flask. 10) Repeat step 9 twice more. Hydrogenation using a bomb reactor: 1) Flush the bomb with inert gas, then follow steps 2-5 from the procedure above ( hydrogenation using a balloon ). 2) Seal the bomb and take it to the hydrogen source. 3) Connect the bomb directly to the hydrogen tank regulator using threaded fittings and slowly fill the bomb with a small amount of hydrogen. Disconnect the threaded fittings and slowly release the slight pressure in the bomb. 4) Repeat step 3 twice more. 5) Connect the bomb once more to the hydrogen tank and fill up the desired pressure (use the gauge on the bomb to determine the pressure). Close the bomb off from the hydrogen source so that it is now sealed. Close off the hydrogen cylinder using the regulator on the hydrogen tank, and disconnect your bomb from the regulator. Workup: 1) For balloon reactions: Detach the hydrogen balloon from the flask and fill with inert atmosphere.

For bomb reactions: Connect a vent line to the bomb and then run the vent line to the back of the fume hood. Then slowly and carefully vent the reaction mixture to atmospheric pressure. 2) Filter the reaction mixture through a bed of Celite (or similar filter aid) 3) Taking care not to let the filter cake filter to dryness, wash with the desired solvent (typically the same solvent used in the reaction) 4) Disconnect the filter from the receiving flask, and then add several ml of water to the filter. 5) Discard the slurried Pd/C and filter aid in a dedicated waste jar that contains water. NOTE: If you must add catalyst to solution, prepare a slurry of Pd/C in dichloromethane or toluene (using steps 1-3 above) and then add this slurry to your reaction mixture. However, this should not be seen as a preferred method. Section 7 Personal Protective Equipment Eye Protection: Wear fitted safety goggles or safety glasses with side shields. Face Protection: Face shields are to be used when there is no protection from the hood sash or when the hood sash is open. Hand Protection: Confirm compatibility of glove material with chemical being used. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Wash and dry hands after use. General guidance: For indirect contact AND direct contact with pyrophoric material - a combination of fire resistant (FR) liners, covered with a pair of chemical-resistant disposable gloves (e.g. nitrile gloves or those specified in the specific SDS)), must be worn AT ALL TIMES. The following products are Approved FR Liners: Ansell Kevlar Goldknit Lightweight 70-200 and Hanz Extremity Wear Nomex Utility 2257C and 2259C. Clothing: Wear Nomex IIIA (NFPA 2112) lab coat; cotton based clothing; full length pants or equivalent; and close-toed and close-heeled shoes. Section 8 Engineering/Ventilation Controls This procedure should be performed in a fume hood in good working condition. Reactions under pressure should be placed behind a blast shield unless they are in a bomb reactor rated to withstand the desired reaction pressure. Section 9 Spill and Accident Procedures In case of small fires, Metal-X, soda ash, or sand can be used. In case of a large fire, use a CO 2 or ABC extinguisher. Do not use water if the reaction was run in a non-alcoholic solvent. In case of an explosion, close the sash of the fume hood. An explosion during a hydrogenation usually expels the contents of the reaction vessel, which can lead to a fire. Be prepared to extinguish a fire. If the contents do not immediately ignite, use a large volume of water or sand to quench the catalyst.

Section 10 Waste Disposal Organic solvents can be discarded in the mixed organic waste stream. Palladium waste should be separated from the mixture and placed in a labeled container that contains water. Any filtration aids suc Celite should also be discarded in the palladium waste stream. It is important to make sure any solid waste from a hydrogenation has been exposed to water prior to disposal Section 11 - Decontamination Remove all contaminated clothing, wash all contaminated skin with copious amounts of water. Section 12 Process Steps Process Steps Safety Measures Training Documentation Name (Printed) Signature Date