How Ventilators Work. Chapter 3

Similar documents
Classification of Mechanical Ventilators

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Milestones of Aeonmed Ventilators

Operation and Maintenance of the EPV200 Portable Ventilator

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Minimum size for maximum performance

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Selecting the Ventilator and the Mode. Chapter 6

Supporting you in saving lives!

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

IEC C LASSIFICATIONS:

Emergency Transport and Ventilation

Hospital and Transport for Controlled Breathing

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

fabian HFO: Modular, Powerful, Versatile.

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Supporting your patients every breath

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Intelligent Ventilation solution from ICU to MRI

DATA SHEET. VENTILATION SERVO-s

Panther 5 Acute Care Ventilator

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

Operation of Oxylog 3000 ventilator

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Apollo Safety Features

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

Dräger Savina Sub-Acute Care Ventilation

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

fabian Therapy evolution Our 2-in-1 device

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

SLE5000 Infant Ventilator with HFO

ekom Compressor for Medical Air Sonata with Ekom

Flight Medical presents the F60

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

A9600 Anesthesia Workstation. Your healthcare, we care.

HAMILTON-C3. The compact high-end ventilator

Ventilator Training Module

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products


Technical Data and Specifications

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

AUTOVENT 4000 VENTILATOR

1 of 9 10/20/2010 4:45 PM

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Blease900 Ventilator PATIENT CENTERED VENTILATION

NEONATAL/INFANT VENTILATOR

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Control Valve : The Final Control Element. Nimish Shah

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017)

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

V8800 Ventilator System. Your healthcare, we care.

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

Medical Instruments in the Developing World

Monnal T60. Touch and Breathe.

SLE5000 Neonatal Ventilator with High Frequency Oscillation

LifeChoice Activox Portable oxygen concentrator. Portable oxygen therapy for patients with active lifestyles. ResMed.com

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Aespire 7100 Essential performance Compact design

Airox Supportair Ventilator

O-Two Self-Study Guide. Equinox Relieve


e500 Automatic Transport Ventilator User Manual e500 User Manual (15PL Rev.7 6_6_2017)

Operating Instructions for Microprocessor Controlled Ventilators

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Intensa GO Alternate Care Ventilator

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

fabian HFO Our 4-in-1 device

Focused on essentials DRÄGER SAVINA 300

The Merlin Small Animal Ventilator by Vetronic Services Ltd. Contents page. Introduction.2. Features of Merlin. 3

SERVO-s v8.0 Data sheet

Anesthesia Workstation

Mechanical Ventilation

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

PART SEVEN THE HISTORY AND APPLICATION OF HIGH FREQUENCY OSCILLATORY VENTILATION (HFOV)

The centerpiece of a comprehensive anaesthesia workstation

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

HAMILTON-C6. The next generation of intelligent ICU ventilators

My CoughAssist. A patient guide to CoughAssist T70. Please visit

Ventilators with Capnograph Smart Sensors

S/5 Aespire. Quick Reference Guide

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Mechanical Ventilation

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

QUICK REFERENCE GUIDE

Your patients, our primary focus

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

D Beyond essentials DRÄGER SAVINA 300 SELECT

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P


Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

Made to meet your needs DRÄGER SAVINA 300

Transcription:

How Ventilators Work Chapter 3

To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts with the patient How changes in lung condition can alter the ventilator s performance Ventilator Classification: The terminology employed by the different manufacturers is confusing!

Internal Ventilator Function black box Plugged into a power source User interface to set the controls Control system to interpret the operators settings to produce the desired output

Power Source : provides the energy to perform the work required to ventilate a patient Electrically Powered Relies on electricity Wall outlet (AC), battery (DC) Powers internal motors which provide gas flow to the patient Pneumatically Powered High pressure gas source Usually 2-50psi sources, air and oxygen Built in reducing valves Pneumatic Fluidic

Combined Power Ventilators Pneumatically powered 50 psi gas sources Mixture of air and oxygen allow variable FiO2 Energy to deliver the breath Electrically powered Controls the internal function May be controlled by a microprocessor (1980 s)

Clinical Rounds 3-1 A patient who requires continuous ventilatory support is being transferred from the ICU to a regular patient room. The regular hospital rooms are equipped with piped in oxygen but not piped in air. What type of ventilator would you select? You would need an electrically powered ventilator with a built- in or external compressor. The availability of oxygen would allow you to provide oxygen as necessary for the patient.

Pressure Delivery Positive Pressure Negative Pressure

Pressure Delivery Combined pressure devices HFV Oscillating gas pressure waveforms, positive and negative pressure

Control Systems Decision making systems Regulates ventilator function internally Open loop versus Closed loop

Control Systems Open Loop unintelligent systems Does not respond to changes in patient condition Does not measure variables or change them Closed Loop intelligent systems Compares the set variable to the measured variable

Clinical Rounds 3-2 A ventilator is programmed to monitor SpO2. If the SpO2 drops below 90% for longer than 30 sec the ventilator is programmed to activate an audible alarm that cannot be silenced and a flashing red visual alarm. The ventilator also is programmed to increase the oxygen percentage too 100% until the alarms have been answered and deactivated. Is this a closed loop or an open loop system? Do you think it is a good idea for a ventilator to have such a system? This is a closed loop system. The ventilator is providing a specific FiO2 and monitors SpO2. The ventilator can detect changes in SpO2 and change the FiO2 setting. It can be argued that this would provide a safeguard for patient who suddenly became hypoxemic. It could also be argued that oxygen saturation monitors are not reliable enough and could result in erroneous readings resulting in an inappropriate ventilator response

Control Panel User interface Monitored and set by the operator Knobs or touch pad/touch screen for setting ventilatory components and alarms Ultimately regulates the four ventilatory variables

Pneumatic Circuit Pathway of gas flow Pressure gradients created by the ventilator s power source generates this flow Internal pneumatic circuit From generating source through the inside of the ventilator External pneumatic circuit Patient circuit Flow between the ventilator and the patient

Single Circuit Design - Internal

Double Circuit Design Internal

Basic Elements of a Patient Circuit Main inspiratory line Adapter Expiratory line Expiratory valve Adjuncts Device to warm/humidify air Thermometer Nebulizer Bacteria filters

Power transmission and conversion Converts the electrical or pneumatic energy into a breath to the patient Consists of: drive mechanism mechanical device that produces gas flow to the patient output control mechanism one or more valves that determine the flow to the patient Categorized as volume controllers or flow controllers

Compressors Used as either a power source or to convert and transmit a power source Reduce internal volumes (compression) resulting in a change in pressure Piston driven, rotating vane (blades), moving diaphragms or bellows

Volume displacement designs Bellows Pistons Concertina bags bag in a chamber

Flow control valves Control and direct flow by opening and closing Complete or incremental movement Rapid response time Great flexibility in flow control Proportional solenoid valve Stepper motor with valve Digital on/off valve configuration

Expiratory Valves Allow exhalation to occur naturally Also applies positive pressure during exhalation to increase the FRC Flow resistance Threshold resistance

CPAP Devices Spontaneously breathing patients Often provided through ventilators Originally and still may use free standing systems

Common features of Ventilators Rapidly changing environment Important to distinguish between different models/versions from the same manufacturer Common internal mechanisms Patient monitoring Parameters and displays Alarms

Infant Ventilators Different approaches to ventilation regardless: must monitor parameters closely provide the appropriate level of support respond to physiologic changes quickly Two different choices for ventilators Ventilators designed exclusively for infants and small children Single ventilator for all ages

Transport Ventilators Requires great care and skill; same level of care and monitoring throughout the transfer Gray area of risk versus benefit Physiologic changes due to gravity of condition not the transport itself Requires preparation and communication Ventilator should be compact, lightweight, reliable power source (internal battery or gas source) Able to function in extreme conditions

Home Care Ventilators One of the fastest growing areas of healthcare, home care is a viable alternative to hospital or extended care facilities Increased ability to support diseases once thought incurable Ventilators must be simple, operator friendly with clear alarms Main caregivers are family!

Noninvasive Ventilators Increased usage in the last 15 years Portable, safe, user-friendly interfaces Requires properly fitting interface

Negative Pressure Ventilators Attempts to mimic normal respiration Applies negative pressure to the outside of the chest The greater the pressure applied the greater the gradient, the greater the volume delivered 3 basic modes: inspiratory negative pressure only, inspiratory negative pressure/positive expiratory pressure, continuous negative pressure