Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Similar documents
Instrument Operating Manual

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Siphon vessel / Priming aid

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Instruction Manual Contact Pressure Vacuum Gauge

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Operating Manual VSA100A. tina29e1 ( )

Operating Instructions

Pressure transmitter model A-10. Druckmessumformer Typ A-10 Transmetteur de pression type A-10 Transmisor de presión modelo A-10

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Gas density monitor With integrated transmitter Model GDM-100-TI

Differential pressure gauge For the process industry Model , all-metal media chamber

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Inverted Bucket Steam Trap IB 16A-7

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Instruction Manual BA90 Precision Barometer

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Pressure Automated Calibration Equipment

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Pneumatic high-pressure controller Model CPC7000

DK46 - DK800 Supplementary instructions

Hydraulic hand test pump Models CPP700-H and CPP1000-H

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Precision pressure sensor Basic version Model CPT6020

Temperature gauge Installation Guide

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure relief valve

Electro-Pneumatic Converter YT-940 SERIES

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Pressure relief valve

Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Declaration of Conformity as per Directive 97/23/EC

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

Type BBS-03, BBS-05, BBS-06, BBS-25

Pressure Equalising Valves Model , for Differential Pressure Gauges

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

M-5071/1111. Electronic Pressure Switch PSW14 series

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

User Manual. Quantos Automated Dosing Liquid Module

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Digital pressure gauge Model CPG500

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Instruction Manual Differential Pressure Transmitter

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Norrsken Family Booklet

OPTIBAR P 1010 C Technical Datasheet

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Installation and Operating Instructions Bypass Flow Meter DST

Non-Return Valve SRK 22A

Notes on equipment protection per EN/IEC and NEMA For Bourdon tube or diaphragm pressure gauges

Notes on equipment protection to DIN EN and NEMA

High-performance submersible pressure transmitter For level measurement Model LH-10

PRAHER PLC-MP AQUASTAR MANAUL 2009

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

Digital pressure gauge Model CPG500

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Instruction Manual Differential Pressure Transmitter

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

System Pressure Manager Standard & System Pressure Manager Plus

Pre-filter for Brushless Blower Instruction Manual

Pressure maintenance valve SDV-P / SDV-P-E

Expansion Thermometers Stainless Steel Series, Model 70

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Declaration of Conformity as per Directive 97/23/EC

Type C-CUT. Quickstart. English Deutsch Français

Storage Shelving. User Manual [Revision 3.0 May 2017]

GI Series Diaphragm Pressure Gauge Guard

Operating and maintenance manual Filter and reducing station Series / 1.0

WIKA INSTRUMENT CORPORATION

OFFICINE OROBICHE S.p.A. 1/9

Instruction Manual EMA 84 Digital Pressure Gauge

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

Transcription:

Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation 6. Faults 7. Maintenance and cleaning 8. Dismounting, return and disposal 9. Specifications Declarations of conformity can be found online at www.wika.com. 02/2018 WIKA Alexander Wiegand SE & Co. KG All rights reserved. WIKA is a registered trademark in various countries. Prior to starting any work, read the operating instructions! Keep for later use! WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de

1. General information The mechanical pressure switch described in the operating instructions has been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certified to ISO 9001 and ISO 14001. These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed. Observe the relevant local accident prevention regulations and general safety regulations for the instrument s range of use. The operating instructions are part of the product and must be kept in the immediate vicinity of the pressure measuring instrument and readily accessible to skilled personnel at any time. Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work. The manufacturer s liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance with these operating instructions, assignment of insufficiently qualified skilled personnel or unauthorised modifications to the instrument. The general terms and conditions contained in the sales documentation shall apply. Subject to technical modifications. Further information: - Internet address: www.wika.de / www.wika.com - Relevant data sheet: PV 35.01 Abbreviations, definitions SPDT Change-over contact type NC Normally closed contact type (NC) is closed at atmospheric pressure NO Normally open contact type (NO) is open at atmospheric pressure COM Common contact GND Ground connection 2. Design and function 2.1 Overview 2.2 Description The pressure element of the model PSM-520 is a resilient bellow which works against a spring mechanism with an adjustable pre-load force. On the spring mechanism there is a contact arm for actuating the SPDT switch contact. The switch is actuated as soon as the force generated by the pressure in the pressure element is greater than the set pre-load force. 2.3 Terms used Maximum operating pressure The maximum static pressure with which the instrument can be used without changing the assured performance data, such as the non-repeatability of the switch point. Reset point The pressure value at which the switch returns to the starting position. Mathematically, the pressure value for the reset point is equal to the pressure value of the switch point minus the switch differential. Switch differential The switch differential is the difference between the switch point and the reset point. This is also known as the switch hysteresis. 2.4 Scope of delivery Pressure switch Operating instructions Cross-check scope of delivery with delivery note. Process connection Switch point setting display Switch differential setting display Switch differential adjustment screw Protection cap for switch point setting Screw for fixing the plastic cover Removable plastic cover 2

3. Safety 3.1 Explanation of symbols... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.... indicates a potentially dangerous situation that can result in light injuries or damage to property or the environment, if not avoided. DANGER!... identifies hazards caused by electrical power. Should the safety instructions not be observed, there is a risk of serious or fatal injury.... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces or liquids, if not avoided. Information... points out useful tips, recommendations and information for efficient and trouble-free operation. 3.4 Personnel qualification Risk of injury should qualification be insufficient! Improper handling can result in considerable injury and damage to equipment. The activities described in these operating instructions may only be carried out by skilled personnel who have the qualifications described below. Skilled electrical personnel Skilled electrical personnel are understood to be personnel who, based on their technical training, know-how and experience as well as their knowledge of country-specific regulations, current standards and directives, are capable of carrying out work on electrical systems and independently recognising and avoiding potential hazards. The skilled electrical personnel have been specifically trained for the work environment they are working in and know the relevant standards and regulations. The skilled electrical personnel must comply with current legal accident prevention regulations. 3.5 Labelling, safety marks Product label 3.2 Intended use The model PSM-520 mechanical pressure switch is fitted with an SPDT switch contact and is used in industrial control, monitoring and alarm applications. The switch point can be be specified by the customer on site. The instrument can switch electrical loads of up to AC 230 V, 10 A. The PSM-520 pressure switch offers many application possibilities with non-corrosive media like oil, water and air. Only use the instrument in applications that lie within its technical performance limits (e.g. max. ambient temperature, material compatibility,...). For performance limits see chapter 9 Specifications. This instrument is not permitted to be used in hazardous areas! The instrument has been designed and built solely for the intended use described here, and may only be used accordingly. The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use. 3.3 Improper use Injuries through improper use Improper use of the instrument can lead to hazardous situations and injuries. Refrain from unauthorised modifications to the instrument. Do not use the instrument within hazardous areas. Do not use the instrument with abrasive or highly viscous media. Any use beyond or different to the intended use is considered as improper use. Serial number Type of contact Article number Switch point Pin assignment Electrical rating Setting range Coded date of manufacture Adjustable switch differential Before mounting and commissioning the instrument, ensure you read the operating instructions! 3

4. Transport, packaging and storage 4.1 Transport Check the instrument for any damage that may have been caused by transport. Obvious damage must be reported immediately. Damage through improper transport With improper transport, a high level of damage to property can occur. When unloading packed goods upon delivery as well as during internal transport, proceed carefully and observe the symbols on the packaging. With internal transport, observe the instructions in chapter 5.2 Packaging and storage. If the instrument is transported from a cold into a warm environment, the formation of condensation may result in instrument malfunction. Before putting it back into operation, wait for the instrument temperature and the room temperature to equalise. 4.2 Packaging and storage Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair). Permissible conditions at the place of storage: Storage temperature: -20... +80 C (-4... +176 F) Humidity: 35... 85 % relative humidity (no condensation) Avoid exposure to the following factors: Direct sunlight or proximity to hot objects Mechanical vibration, mechanical shock (putting it down hard) Soot, vapour, dust and corrosive gases Hazardous environments, flammable atmospheres Store the instrument in its original packaging in a location that fulfils the conditions listed above. If the original packaging is not available, pack and store the instrument as described below: 5. Commissioning, operation Before installation, commissioning and operation, ensure that the appropriate instrument has been selected in terms of design and specific measuring conditions. Tools: Cross-head screwdriver, socket wrench 8 mm, open-ended spanner 14 mm 5.1 Requirements at the measuring point The process pressure must not exceed the specified maximum operating pressure. Permissible ambient and medium temperatures remain within the performance limits. Protected from weather influences. Any vibrations or shocks which occur must not exceed accelerations of 1 g (9.81 m/s 2 ) within a frequency range of 10... 150 Hz. Sealing faces are clean and undamaged. Sufficient space for a safe electrical installation. For performance limits see chapter 9 Specifications 5.2 Mechanical mounting After unpacking the instrument, a visual inspection for damage must be carried out. Mounting is only permitted in the depressurised state. Reliably depressurise the instrument using the available valves and protective devices. Use seals suitable for the process connection provided. When screwing the instruments in, the force required for sealing must not be applied through the case, but only through the spanner flats provided for this purpose on the process connection, and using a suitable tool. The tightening torque is dependent on the selected process connection. For panel fitting, there are 3 5.2 mm (0.2 in) mounting holes provided. As described in the following chapter, the plastic cover must be removed for this. 4

5.3 Default switch point setting 1. Remove the protection cap for switch point setting 2. Remove the plastic cover 5.4 Electrical mounting DANGER! Danger to life caused by electric current Upon contact with live parts, there is a direct danger to life. The instrument may only be installed and mounted by skilled personnel. Switch off the load circuit before starting work and secure against being switched on unauthorised. Cable preparation Size the connecting cables for the largest current strength in the circuits and ensure sufficient UV resistance and mechanical stability. Recommendation: 4-wire cable with conductor cross-section of 1.5 mm², max. outer 14 mm. Wire ends fitted with spade lugs. 3. Set the switch differential to a minimal value 4. Preset the switch point with auxiliary scale 5. Preset the switch differential with auxiliary help screen Clamping the cable 1. Remove the rubber grommet and match it to the cable diameter 2. Insert the rubber grommet and route the cable as shown 3. Carry out the terminal assignment according to the switching function, max. tightening torque: 2 Nm (18 lbf in) 4. Close the plastic cover and fix again with screw 2 1 3 Ground connection 1 NC Normally closed 2 COM Common contact 3 NO Normally open GND Ground connection Grounding Include the ground connection in the inside of the instrument into the grounding concept of the installation. 5

5.5 Switch point setting For an exact setting of the switch point, a test assembly with pressure generation and pressure reference is needed. This test assembly can, for example, be realised with a model CPG1500 precision digital pressure gauge and a model CPP30 hand test pump (not shown). 5. If the switch point and the reset point coincide with the required pressure values, the switch point setting is complete. 6. Remount the protection cap for switch point setting. The switch point setting must be checked after 2 years. 6. Faults 1. Connect the model PSM-520 pressure switch, pressure reference and pressure generation to a common pressure system. 2. Ensure that the switch point setting does not switch any loads on or off by mistake. For visualisation of the switching function, an equivalent circuit, e.g. with a light bulb, is recommended. 3. Drive slowly towards the required switch point pressure with the pressure generation and pressure reference. - If the instrument switches before the required switch point is reached, the adjustment screw must be corrected to the right (+). - If the instrument switches after the required switch point is reached, the adjustment screw must be corrected to the left (-). After each correction, release the pressure and repeat this procedure until the switch point is set correctly. 4. Release the pressure slowly and check the reset point. - If the pressure value of the reset point is too high, the adjustment screw for the switch differential must be corrected to the left (+). - If the pressure value of the reset point is too low, the adjustment screw for the switch differential must be corrected to the right (-). After correcting the switch differential, the switch point must be re-checked. Carry out step 3 again. Physical injuries and damage to property and the environment If faults cannot be eliminated by means of the listed measures, the instrument must be taken out of operation immediately. Ensure that there is no pressure in the instrument and that the load circuit is switched off. Protect against being put into operation accidentally. Contact the manufacturer. If a return is needed, please follow the instructions given in chapter 8.2 Return. Physical injuries and damage to property and the environment caused by media Upon contact with hazardous media, harmful media (e.g. corrosive, toxic, carcinogenic), and also with refrigeration plants and compressors, there is a danger of physical injuries and damage to property and the environment. Should a failure occur, aggressive media with extremely high temperature and under high pressure or vacuum may be present at the instrument. For these media, in addition to all standard regulations, the appropriate existing codes or regulations must also be followed. For contact details see chapter 1 General information. 6

Faults Causes Measures Contact is not switching in accordance with the specification at the set switch point/reset point Short circuit Contact chatter (repeated, short-duration opening and closing). Switching status remains unchanged despite reaching the switch point/reset point. Electrical connection is interrupted. Wiring error, e.g. short circuit Electrical load unsuitable for the switch contact model. Contact contaminated. Switch differential greater than the switch point. Vibrations Moisture in the instrument. Vibrations Error with switch point setting. Contacts defective (e.g. fused contact zone). Pressure port blocked. Leakage Carry out a continuity test on the electrical connection lines. Check the pin assignment and correct it if necessary Maintain the permissible electrical loads for the switch contact model. Carry out switch point setting with matching test assembly, see chapter 5.5. Decouple the instrument mechanically. Only use in ambient conditions for which the ingress protection is suitable. Decouple the instrument mechanically. Carry out switch point setting with matching test assembly, see chapter 5.5. Replace instrument Before recommissioning the new instrument, provide a protective circuit for the contact. Replace instrument Carry out a leak test. Seal the process connection or replace the instrument. For the exchange of the instrument chapters 8 Dismounting, return and disposal and 5 Commissioning, operation must be observed. 7. Maintenance and cleaning 7.1 Maintenance The instruments are maintenance-free. The switch point setting must be checked after 2 years. Carry out switch point setting with matching test assembly, see chapter 5.5. Repairs must only be carried out by the manufacturer. 7.2 Cleaning Physical injuries and damage to property and the environment Improper cleaning may lead to physical injuries and damage to property and the environment. Residual media in the dismounted instrument can result in a risk to persons, the environment and equipment. Carry out the cleaning process as described below. 1. Before cleaning, correctly disconnect the instrument from the pressure supply and switch the load circuit off. 2. Use the requisite protective equipment. 3. Clean the instrument with a moist cloth. Electrical connections must not come into contact with moisture! Damage to the instrument Improper cleaning may lead to damage to the instrument! Do not use any aggressive cleaning agents. Do not use any hard or pointed objects for cleaning. 4. Wash or clean the dismounted instrument, in order to protect persons and the environment from exposure to residual media. 8. Dismounting, return and disposal Physical injuries and damage to property and the environment through residual media Residual media in the dismounted instrument can result in a risk to persons, the environment and equipment. Observe the information in the material safety data sheet for the corresponding medium. Wash or clean the dismounted instrument, in order to protect persons and the environment from exposure to residual media. 8.1 Dismounting Risk of burns During dismounting there is a risk of dangerously hot media escaping. Let the instrument cool down sufficiently before dismounting it! DANGER! Danger to life caused by electric current Upon contact with live parts, there is a direct danger to life. The dismounting of the instrument may only be carried out by skilled personnel. Remove the instrument once the system has been isolated from power sources. 7

Physical injury When dismounting, there is a danger from aggressive media and high pressures. Observe the information in the material safety data sheet for the corresponding medium. Dismount the instrument when there is no pressure. 8.2 Return Strictly observe the following when shipping the instrument: All instruments delivered to WIKA must be free from any kind of hazardous substances (acids, bases, solutions, etc.) and must therefore be cleaned before being returned. Physical injuries and damage to property and the environment through residual media Residual media in the dismounted instrument can result in a risk to persons, the environment and equipment. With hazardous substances, include the material safety data sheet for the corresponding medium. Clean the instrument, see chapter 8.2 Cleaning. When returning the instrument, use the original packaging or a suitable transport packaging. 8.3 Disposal Incorrect disposal can put the environment at risk. Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-specific waste disposal regulations. 9. Specifications Operating conditions Permissible temperature ranges Ambient: -25... +70 C (-13... +158 F) Medium: -20... +70 C (-4... +158 F) Storage: -20... +80 C (-4... +176 F) Reference conditions Relative humidity per BS 6134 < 50 % r. h. at 40 C (104 F) < 90 % r. h. at 20 C (68 F) Ingress protection per IEC/EN 60529 IP33 The ingress protection is only valid if all mounting holes on the rear of the instrument are covered, or for panel mounting on flat surfaces. Unit Setting range Permissible switch point Adjustable switch Max. working 1) on rising pressure differential 2) pressure bar 0... 5 0.4... 5 0.4... 4 16 0... 7 0.6... 7 0.6... 6 16 6... 15 7.5... 15 1.5... 5 32 6... 30 9... 30 3... 8 42-0.4... +7 0.2... 7 0.6... 6 16 psi 0... 70 6... 70 6... 55 230 0... 100 9... 100 9... 85 230 85... 215 107... 215 22... 72 450 85... 425 130... 425 45... 115 610-6... +100 3... 100 9... 85 230 1) Switch point and reset point have to be within the setting range 2) The difference between the switch point and the reset point is also known as switch hysteresis Non-repeatability of the switch point 2 % of span Switch contact 1 x change-over contact / SPDT 3) COM p 3) Single pole double throw Electrical rating Current consumption 4) Voltage Current Resistive load AC 230 V 10 A AC-1 Inductive load AC-15 AC 230 V 6 A 4) per DIN EN 60947-1 NO NC NC COM NO p Normally closed Common contact Normally open Pressure For further specifications see WIKA data sheet PV35.01 and the order documentation. 8