RMP/PSM WEBINAR SERIES

Similar documents
PSM/RMP WEBINAR SERIES

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

ACCU-PULSE Installation and Operation Instructions

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Installation Operation Maintenance

Spirax Compact FREME Flash Recovery Energy Management Equipment

GAS COMPRESSION SYSTEM

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Horizontal Bladder Tanks

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

Vertical Bladder Tanks

Regulations Respecting Compressed Gas Pressure Vessels

TEST BENCH FOR SAFETY VALVES


DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

IRC 2011 All Rights Reserved

Gas Injection Systems

Model MTB-ASME Vertical Bladder Tanks

M-06 Nitrogen Generator (Nitrogen Making Machine)

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Compressors. Basic Classification and design overview

CO 2 radial piston compressor (transcritical)

DF1 and DF2 Diffusers

Liquid ring vacuum pumps in compact design

Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

System Pressure Manager Standard & System Pressure Manager Plus

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

MSC Guidelines for Pressure Vessels

Liquid ring vacuum pumps in compact design

Budget Range Operators Handbook

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS

JORDAIR/BAUER Service Manual

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Manual Actuated Boiler Blowdown Valves

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

Pressure Relief Device Investigation Testing Lessons Learned

Standard Pneumatic Test Procedure Requirements for Piping Systems

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Troubleshooting Guide. Pg. 1

SIHI LPH-X - Liquid Ring Compressors

FV Flash Vessel Installation and Maintenance Instructions

PURPOSE OF THE POLICY

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Official Journal of the European Union L 92/3

EZ-CAL HIGH PRESSURE CUT-OUT TEST BLOCK & CALIBRATION KIT

INSTRUCTION MANUAL & PARTS

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

KKT Training Series: ECO Series, Preventative Maintenance

Liquid ring compressor

Liquid ring vacuum pumps single-stage

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Temporary Equipment Checklist

Diaphragm relief valve

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Installation, Operation, & Maintenance Manual NX Seal Cooler

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

Thank You for Attending Today s Webinar. Today s Featured Speaker

Unit 24: Applications of Pneumatics and Hydraulics

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Liquid Ring Compressor Catching Chemicals Conserving Cash

Development of a High Pressure, Oil Free, Rolling Piston Compressor

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives)

Before You Fix the Relief Valve Problem

AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF. SEMS HAZARD ANALYSIS TRAINING September 29, 2011

COMPRESSED GASES CHAPTER 53

SECTION P4 SEPARATION SYSTEMS

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

NGP-250/500 Nitrogen Generator Quick Start Guide

Diaphragm Pressure Keeping Valve

Workhorse-15 Oxygen Generator

GAS DEHYDRATION SYSTEM

CNG FILLING STATIONS

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

6301 TYPE CAST IRON SAFETY VALVES

QuickHeat TM Packaged Heat Exchanger Solutions

DCV6 Disc Check Valve

OPERATING INSTRUCTIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Transcription:

RMP/PSM WEBINAR SERIES Webinar Starts at 08:00 PT Please call (877) 532-0806 if you are having technical issues. The background music may be used to adjust your audio volume. IIAR STANDARDS AND HOW THEY APPLY TO RAGAGEP PART 3 Stephanie Smith, PE and Max Oppedahl Risk Management Professionals, Inc. (949) 282-0123 (877) 532-0806 Risk Management Professionals 1

RISK MANAGEMENT PROFESSIONALS Key Services Process Safety & Risk Management Process Hazard Analysis (PHA) What-If? Studies Hazard & Operability (HAZOP) Studies Layer of Protection Analysis (LOPA) Safeguard Protection Analysis (SPA) Safety Integrity Level (SIL) Assessment & Verification Process Safety Management (PSM) Risk Management Program (RMP) California Accidental Release Prevention (CalARP) Program Nevada Chemical Accident Prevention Program (CAPP) Security Vulnerability Assessment (SVA) Inherently Safer Technology (IST), Hierarchy of Hazard Control Analysis (HCA), Safer Technology & Alternatives Analysis (STAA) Safety & Environmental Management Systems (SEMS) Damage Mechanism Review (DMR) Safety Case Key Services (cont.) ERP Development & Emergency Preparedness Training (NIMS-Compatible) Risk-Graph and Bow-tie Analysis QRA Services FTA & ETA Background Services to Process Industries, Utilities, & Government Since 1995 International w/us Focus Qualifications Extensive Experience Two Decades of Risk-Based Applications Engineering, Safety, Security, and Emergency Response Backgrounds Locations HQ: Irvine, CA Houston Norfolk Walnut Creek Contact info@rmpcorp.com U.S. (877) 532-0806 SUMMARY General IIAR 2 Information Overview of Part 1 and 2 ANSI/IIAR 2-2014 Chapter 8 Compressors Chapter 9 Refrigerant Pumps Chapter 10 Condensers Risk Management Professionals 2

ANSI/IIAR 2-2014 Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems Partial purpose of the update was to compare to ASHRAE Standard 15, NFPA code, Uniform Mechanical Code, International Mechanical Code, and International Fire Code Part 3 discusses Chapters 8, 9 and 10 DEFINITIONS Compressors: A machine used to supply air or other gas at increased pressure. Ultimate Strength: The capacity of a material or structure to withstand loads tending to elongate. Refrigerant Pumps: A mechanical device using suction or pressure to raise or move liquids, compress gases and refrigerants. Maximum Allowable Working Pressure (MAWP): The maximum pressure permissible at the top of the vessel in its normal operating position at a designated temperature. Condenser: An apparatus for changing gaseous substance into a liquid substance Risk Management Professionals 3

DEFINITIONS Shall (shall not): A term used where the provision is mandatory. Should (should not): A term used where the provisions are not mandatory but are (are not) recommended good practice under most but not all conditions. Pressure Relief Device: a device designed to open in a controlled manner to prevent the internal pressure of a system from increasing beyond a specific value. Minimum Design Metal Temperature (MDMT): The lowest temperature permitted according to the metallurgy of the vessel fabrication materials and the thickness of the vessel component. CHAPTER 8: COMPRESSORS 8.1 Ammonia Refrigeration Compressors shall comply with this section. 8.2 Design Design Pressure shall comply with Section 5.5 (General System Design Pressure). Positive-Displacement Compressor with a stop valve in the discharge connection will be protected with pressure relief device that is set at the lowest MAWP of any connected equipment. Minimum size compressor relief connection shall comply with Section 12.2.3 and 15.4.2. Risk Management Professionals 4

CHAPTER 8: COMPRESSORS 8.2 Design (cont.) Compressor shall have limiting device which shuts down the compressor when there is low-suctionpressure, high-discharge-pressure and highdischarge-temperature. Protection for rotating parts shall comply with Section 5.17.2. If rotation is only in one direction, a rotation arrow shall be attached to the device. Ultimate strength requirements shall comply with Section 5.13.2. 8.3 Shall be tested for strength at 1.5 times pressure, for leaks, and proven tight at design pressure or greater. CHAPTER 8: COMPRESSORS 8.4 Equipment Identification Labels shall have the following: Manufacturer s Name, Manufacturer s serial number, Manufacturer s model number, Year manufactured, MAWP, Maximum Rotation speed in rpm and Direction of rotation if applicable. If these requirements above are not fulfilled, the compressor shall not be used. Risk Management Professionals 5

CHAPTER 8: COMPRESSORS 8.5 Compressor Installation Must have a valved connection. If the area has low ambient temperature, then condensation in compressor must be prevented. Designs will include foundations. If a variable frequency drive is used, then follow all manufacturer s instruction and make sure all frequencies are stable. Shall be operated within manufacturer's design limitations. Shall have a check valve to avoid back flow of ammonia mixtures. CHAPTER 8: COMPRESSORS 8.5 Compressor Installation (cont) Any used compressors shall be checked for any manufacturer design alterations, especially those which may affect integrity of casting. Shall have pressure and temperature indicating devices like gauges or readouts which show suction pressure, discharge pressure, oil pressure and discharge temperature. If compressor is connected to vessel and if High liquid level alarm of vessel activates, then the compressor will have control to shutdown. Risk Management Professionals 6

CHAPTER 9: REFRIGERANT PUMPS 9.1 Refrigerant pumps covered 9.2 Design Minimum design pressure must comply with Section 5.5. Means of protecting pumps and piping from hydrostatic overpressure shall be provided. Must comply with ultimate strength requirements from Section 5.13.2. Must be protection from exposed rotating parts from Section 5.17.2. Pumps must be suitable for the service. Refrigerant pumps shall be provided with isolation valves. Pump supports and foundation must comply with Section 5.11. CHAPTER 9: REFRIGERANT PUMPS 9.3 Refrigerant pumps shall be strength tested to a minimum 1.5 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer. 9.4 Name plate requirements: Manufacturer s Name, Manufacturer s serial number, Manufacturer s model number, Year manufactured, MAWP, Maximum Rotation speed in rpm, and Direction of rotation. 9.5 Pumps shall have a way to remove ammonia. Risk Management Professionals 7

10.1 Condensers are covered. 10.2 Tube-and-fin and micro-channel type air-cooled condensers and air cooled de-superheaters are covered by this section. Minimum design pressure must comply with Section 5.5. Must comply with ultimate strength requirements from Section 5.13.2. If inlet and outlet piping can be isolated, then there will be a hydrostatic overpressure protection complying with Section 15.6. Must be protection from exposed rotating parts from Section 5.17.2. Fan speeds shall not exceed manufacturer s recommendations for speed limit. Shall be strength tested to a minimum 1.1 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer. 10.2 Air-cooled condensers and air-cooled de-superheaters (Cont.) Permanent label required with the following information: Manufacturer s Name, Manufacturer s serial number, Manufacturer s model number, Year manufactured, Design Pressure, Direction of fan rotation, Electric motor power, and Electrical supply: volts, full load amps, frequency (Hz), phase. Air-cooled condensers shall be installed with manufacturers minimum clearances. Risk Management Professionals 8

10.3 Evaporative condensers are covered by this section Minimum design pressure must comply with Section 5.5. Must comply with ultimate strength requirements from Section 5.13.2. Pressure vessel attached or used in the evaporative condensers system must comply with Chapter 12. If inlet and outlet piping can be isolated, then there will be a hydrostatic overpressure protection complying with Section 15.6. Must be protection from exposed rotating parts from Section 5.17.2. Fan speeds shall not exceed manufacturer s recommendations for speed limit. 10.3 Evaporative Condensers (Cont) Shall be strength tested to a minimum 1.1 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer Shall be labeled with the following information: Manufacturer s name, Manufacturer s serial number, Manufacturer s model number, Year manufactured, Design pressure, Direction of fan rotation and water-circulating pump, Electric motor rating for fans and water-circulating pump, and Electric supply: volts, full load amps, frequency (Hz), phase Risk Management Professionals 9

10.3 Evaporative condensers (Cont) Air-cooled condensers shall be installed with manufacturer s minimum clearances. Condenser and piping near condenser must be protected from the water getting frozen in order to prevent damage. The waste water and overflow from the evaporative condenser needs to be drained properly in order to avoid hazard. 10.4 Shell-and-Tube Condensers are covered by this section. This includes horizontal and vertical condensers with closed water and open water passes. Minimum design pressure must comply with Section 5.5. Must comply with ultimate strength requirements from Section 5.13.2. Pressure vessel attached or used in the evaporative condensers system must comply with Chapter 12. If inlet and outlet piping can be isolated then there will be a hydrostatic overpressure protection complying with Section 15.6. Protection against hydrostatic overpressure from the secondary inlet and outlet cooling will be provided in accordance with Section 15.6. Risk Management Professionals 10

10.4 Shell-and-Tube Condensers (Cont) Shall be strength tested to a minimum 1.1 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer. Shall be labeled with the following information: Manufacturer s name, Shell-side MAWP and temperature, Tube-side MAWP and temperature, Shell-side MDMT and pressure, Tube-side MDMT and pressure, Manufacturer s serial, and Year Manufactured. Where possible clearance shall be provided for maintenance to service the condenser. 10.5 Plate Heat Exchanger condenser are covered by this section including plate and shell type and plate and frame type. Minimum design pressure must comply with Section 5.5. Must comply with ultimate strength requirements from Section 5.13.2. Pressure vessel attached or used in the evaporative condensers system must comply with Chapter 12. Inlet and outlet piping of the plate containing ammonia can be isolated allowing the ammonia side of plate to have pressure relief protection according to Section 15.3. Risk Management Professionals 11

10.5 Plate Heat Exchanger Condenser (Cont.) The nonrefrigerant process fluid lines of plate packs shall be protected from hydrostatic overpressure in accordance to Section 15.6 Shall be strength tested to a minimum 1.1 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer. Shall be labeled with the following information: Manufacturer s name, Hot-side MAWP and temperature, Cold-side MAWP and temperature, Hot-side MDMT and pressure, Cold-side MDMT and pressure, Manufacturer s serial, and Year Manufactured. Clearance is given for plate maintenance. 10.6 Double-Pipe condensers are covered by this section including double-pipe with closed-water passes. Minimum design pressure must comply with Section 5.5. Must comply with ultimate strength requirements from Section 5.13.2. Pressure vessel attached or used in the evaporative condensers system must comply with Chapter 12. If inlet and outlet piping of the double-pipe condenser can be isolated, then the refrigerant side of plate will have pressure relief protection according to Section 15.3. If there is a second cooling piping system of doublepipe condensers and can be isolated, then it shall be protected from hydrostatic overpressure according to Section 15.6. Risk Management Professionals 12

10.6 Double-Pipe Condenser (Cont.) Shall be strength tested to a minimum 1.1 times the design pressure, subsequently leak tested and proven tight at pressure greater than or equal to design pressure by manufacturer. Shall be labeled with the following information: Manufacturer s name, Shell-side MAWP and temperature, Tube-side MAWP and temperature, Shell-side MDMT and pressure, Tube-side MDMT and pressure, Manufacturer s serial, and Year Manufactured. Construction shall follow ASME B&PVC, Section VIII, Division 1. Shall have clearance allowing the replacement or removal of condenser pipes. WHAT S NEXT? Chapter 11 Evaporators Chapter 12 Pressure Vessels Chapter 13 Piping * This agenda may be changed based on information presented and time allotted for the next webinar. Risk Management Professionals 13

Feb. 23, 2017 UPCOMING WEBINARS / CONFERENCES Sponsor and exhibitor at the event. Central Valley Chemical Safety Day Feb. 27, 2017 Attendee IIAR National Conference March 21, 2017 Webinar PSM/RMP Modernization Programs in California New 2016 Developments and Correlation to Evolution at the Federal Level Presented by Steve Maher, PE and Aleks Metulev April 6, 2017 Webinar Nevada CAPP Regulations and How to Prepare for an Audit Presented by David Childs April 28, 2017 Sponsor and exhibitor at the event. LA RETA Safety Day QUESTIONS? Stephanie Smith, PE and Max Oppedahl Stephanie.Smith@RMPCorp.com Max.Oppedahl@RMPCorp.com Risk Management Professionals, Inc. (949) 282-0123 (877) 532-0806 Risk Management Professionals 14