Amec Foster Wheeler 2016.

Similar documents
Notice of Intent to Close Inactive CCR Surface Impoundments

Written Closure Plan. Pawnee Station - North CCR Landfill Public Service Company of Colorado Denver Colorado. October 17, 2016

CLOSURE PLAN. CCR (b) GERS Landfill Area. Welsh Power Plant Pittsburg, Texas. October, 2016

CCR Closure Plan. CCR Certification: Written Closure Plan (b) & (c) for the. Landfill Sedimentation Pond. A. B. Brown Generating Station

Written Closure Plan. Pawnee Station - Active CCR Landfill Public Service Company of Colorado Denver Colorado. October 17, 2016

CCR Landfill 2017 Annual Inspection Report NC1 Ash Disposal Area

D.B. Wilson Station CCR Landfill

CLOSURE PLAN. CFR (b) Document ID: GERS Bottom Ash Complex. Mountaineer Plant New Haven, West Virginia.

CLOSURE PLAN. CFR (b) Bottom Ash Pond Complex Cardinal Plant Brilliant, Ohio. September, 2016

TABLE OF CONTENTS LEGAL NOTICE

Effect of Perched Water Conditions in MSW Landfills: Considerations for Landfill Operators

CLOSURE PLAN. CFR (b) GERS Bottom Ash Pond. Northeastern 3&4 Power Station Oologah, Oklahoma. October, 2016

CLOSURE PLAN. CCR (b) GERS East and West Bottom Ash Ponds. Pirkey Power Plant Hallsville, Texas. October, 2016

TABLE OF CONTENTS LEGAL NOTICE

TABLE OF CONTENTS LEGAL NOTICE

CCR Unit Closure and Post-Closure Plan. The business of sustainability. Texas Municipal Power Agency Gibbons Creek Steam Electric Station

Coal Combustion Residuals Closure Plan

Written Closure Plan. Comanche Station - Active CCR Surface Impoundment Public Service Company of Colorado Denver, Colorado

FUGITIVE DUST CONTROL PLAN

Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

Written Closure Plan. Cherokee Station - Active CCR Impoundments Public Service Company of Colorado Denver, Colorado.

Mr. Michael Malone CPS Energy 145 Navarro Street, Mail Drop San Antonio, Texas Project No

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project

EUROFLO CULVERT PIPE. Fittings / Pipes

EUROFLO CULVERT PIPE. Fittings / Pipes

S EVERAL YEARS AGO the

Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]

GENESIS FACILITY, EASTERN CREEK COMPLAINTS REGISTER (updated monthly) Genesis Complaints Register Page 1

Annual CCR Landfill Inspection. Lansing Landfill. Interstate Power and Light Company. Prepared for:

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Researchers propose a cost effective solution for failing native soil athletic fields across Michigan.

Introduction. Geomembrane lining systems are used in a variety of different applications. Landfill Lining Landfill Capping Salt Piles Lagoons / Ponds

Closure Plan for CCR Surface Impoundments

COURSE SUPERINTENDENT S REPORT

ROAD MAINTENANCE Potpourri MUTCD Speed Limits Road Closures Springtime Maintenance Concerns by Duane A. Blanck, P.E.

October 16, GRDA CCR Landfill Compliance Report Grand River Dam Energy Center 8142 Hwy 412B PO Box 609 Chouteau, OK Dear Mr.

COTTER MILL SITE SUMMARY - RML

INFILTRATION PRACTICE MAINTENANCE INSPECTION FORM

TABLE OF CONTENTS 1.0 INTRODUCTION PLAN CERTIFICATION (B)(4) 1

Geofabrics. Products to improve the playability of your course. golf courses

EXHIBT A - BID FORM SUNSET VALLEY GOLF COURSE. Golf Course Master Plan Implementation. Date: December 1, 2016

Suitable Applications Check dams may be appropriate in the following situations: To promote sedimentation behind the dam.

TRADESMAN DRAINLAYER

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

Design Assessment Checklist: Infiltration / Detention Basin

Spring YOURCOURSE BIGGA Aeration.indd 46 11/01/ :37

AMEC010570_0001. Via . Mt. Polley Mine Tailings Facility Optimization Potential- Follow Up from Dam Safety Review 1.

2017 Annual Inspection Report

Water Storage for Agriculture

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Rhode Island

Implementation of an Asset Management Software for Proactive Management and Optimization of the Collection System Rehabilitation and Renewal Program

GRAVEL ROAD MAINTENANCE PLAN FOR THE TRANSPORT OF SOLAR ENERGY EQUIPMENT FROM CAPE TOWN TO THE ALEXANDER BAY AREA

DURBANVILLE GOLF CLUB COURSE REPORT APRIL 2013

GRASS PITCHES FOR RUGBY

EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

Bathing Water Profile - Carne (2017)

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

Golf Course Update June 2015

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

January 18, 2019 See next page for additional Wednesday meetings. Page 1

Aquatic Facilities Water Spray/Play Ground Application, Design & Operating Requirements Environmental Health Guide

Gourock Golf Club. Report on Proposed Course Improvement Works. 11th April 2016

SOIL IMPROVEMENT BY VACUUM PRELOADING FOR A POWER PLANT PROJECT IN VIETNAM

COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:

CCR Landfill 2015 Annual Inspection Report NC1 Ash Disposal Area

Stability of slopes of municipal solid waste landfills with co-disposal of biosolids

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

Analyzing Drainage Problems and Applying Proper Drainage Techniques January 6, 2004 I. Analyzing and Classifying Drainage Problems

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

An Example of a Unique Partnership for Contaminated Sediment Management The Port Hueneme Experience

Spading to overcome non wetting soil

MATERIAL SAFETY DATA SHEET

SOAH DOCKET NO TCEQ DOCKET NO MSW PREFILED DIRECT TESTIMONY REX H. HUNT, P.E.

Lecture 8&9: Construction Dewatering

If you have any questions or comments, please feel free to contact me at

Thermoplastic Road Marking Applicator

SAND IS ONE of the most common

The Past. The Present. The Future. Objective of turf manager High quality appearance of turf Complementing the surrounding environment.

Siting and Installation Manual

Method Statement: Testing Dry Riser System

COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:

COAL COMBUSTION RESIDUALS FUGITIVE DUST CONTROL PLAN

Glen Oak Country Club. Steve McDonald Turfgrass Disease Solutions, LLC

PRELIMINARY STORM DRAINAGE REPORT

ROAD OCCUPANCY PERMIT APPLICATION # Damascus Township, 60 Conklin Hill Road, Damascus, PA Tel Fax

Dare County Nourishment Project Town of Duck

Nothing So Constant as Change

The Spartan Cap Athletic Field System

Report Date: February 20, 2018 Contact: Nick Kassam Contact No.: RTS No.: VanRIMS No.: Meeting Date: March 14, 2018

Dredging Engineering Short Course Texas A&M University January 2016

EQUIPMENT, AND SUPPLIES. Delivering Environmental, Industrial, and Emergency Solutions

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Minnesota

MSW Objective 1.1: Level of Service Standards To maintain the IMSWMS MSW collection system to meet or exceed established LOS standards.

Water Resources Report RKLD Annual Meeting July 30, 2016

Shoalwater Bay Shorline Erosion Dredging

Advantages & Specifications for the Use of Perma-Patch for the Repair of Potholes

Report Prepared for Glen Oak Country Club September 2016 Turfgrass Disease Solutions, LLC Steven McDonald, M.S. On Saturday September 3 rd, I visited

USGA GREEN SECTION TURF ADVISORY SERVICE REPORT

Transcription:

Landfill Closure An Innovative Geosynthetic Barrier System ESAA Remtech 2016 Dean Wall & Ian MacLeod

Why Do We Close Landfills? It s the law To minimize post closure environmental liability To minimize post closure financial liability 3

Is the Lowest Capital Cost the Wise Choice for Closure? Long term post closure costs are frequently not considered in cost analysis Long term financial and environmental liabilities may not be fully understood 4

Alberta Final Cover Requirements (Standard Regulatory Cover - soil) (ii) a final cover system consisting of three layers constructed in the following order from bottom to top: a. 0.60 metres barrier layer with a maximum hydraulic conductivity of 1 x 10-7 metres per second; b. subsoil; and c. 0.20 metres of topsoil. 5

Landfill Capping Options for Closure 1. Standard Regulatory Cover 2. Compacted Clay Cover (with frost protection) 3. Geosynthetic Cover (Geomembrane and/or Geosynthetic Clay Liner) 4. Water Balance (Store and Release) Cover 5. Infiltration Cover 6

Standard Regulatory Cover - Compacted Clay Add segment and caption if required. 7

Standard Regulatory Cover - Compacted Clay Pros Low capital cost if suitable clay soils are present on site. Permit approvals/registrations straight forward. Specialized contractors not required. Cons Highly susceptible to wetting/drying and freeze/thaw cycles. Several order of magnitude increase in permeability years after construction. Typically more permeable than bottom liner systems (i.e. landfill will accumulate water and may require leachate collection and treatment in perpetuity). Ongoing leachate treatment or disposal costs could be very significant. 8

Geosynthetic Barrier Cover Add segment and caption if required. 9

Geosynthetic Barrier Cover Pros Readily obtainable and can be shipped anywhere. High level of quality control during manufacturing Not significantly affected by wetting/drying and freeze/thaw cycles. Very low infiltration rates. Can potentially eliminate ongoing leachate generation resulting in reduced treatment and disposal costs. Cons Capital costs are typically higher than standard regulatory covers. Thin layers that must be installed with care by specialized subcontractors. Require gas control and venting if waste is gas generating. Require drainage control above geomembrane. 10

Case Study of a Geosynthetic Barrier Cover Located in a wet environment Annual rainfall over 2000 mm 24 hour rainfall events of 100 mm Non freezing conditions most of the year No local source of clay borrow Leachate currently treated with process effluent No incremental cost while operating Client was promised a low cost water balance cover by a consultant Is it appropriate? 11

Cover Details Gas venting layer Geosynthetic DrainTube layer, lateral pipe network with vents Barrier layer Composite geosynthetic cover consisting of a geomembrane over a GCL Drainage layer Geosynthetic DrainTube layer with rip-rap lined channels Vegetation layer Manufactured topsoil layer (sand and biosolids) 12

Gas Venting Layer trenching and drain rock 13

Gas Venting Layer vent piping 14

Gas Venting Layer before DrainTube 15

Gas Venting Layer DrainTube installation 16

Barrier Layer GCL over DrainTube Add segment and caption if required. 17

Barrier Layer GCL Add segment and caption if required. 18

Barrier Layer Geomembrane over GCL Add segment and caption if required. 19

Barrier Layer Completed geomembrane Add segment and caption if required. 20

Completed Geosynthetics Add segment and caption if required. 21

Drainage Layer DrainTube and ditching 22

Drainage Layer Surface water ditching 23

Vegetation Layer Subsoil and topsoil 24

Vegetation Layer Fall after planting 25

Vegetation Layer Four years after planting 26

Costs / Benefits of DrainTube Geocomposite 27

Project Successes Approximately 30% of the landfill has been closed with this capping technique to date. Client reports substantially reduced levels of leachate within the closed section of the landfill. Client reports quantity of leachate being transferred to the effluent treatment system has reduced by approximately 50% from previous levels and further reductions are expected. 28

Any Questions? Dean Wall, M.Sc., P.Eng. dean.wall@amecfw.com (250) 354-1601 29