A measured step forward

Similar documents
Double-diaphragm system

Chlorine scrubber. Operating instructions. Read the operating manual! The user is responsible for installation and operation related mistakes!

Full-Vacuum Chlorinator C 2212 MB / 1

VACCUPERM Vacuum chlorine gas dosing systems

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Highest Quality. Gas Chlorination Systems

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Chlorinator. MODEL C-731 (Floor Mounted)

ProMinent Gas Chlorination

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Chlorinator MODEL MK-I

MEDAP-MOBILE GAS SUPPLY

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

Vaccuperm accessories

GENO -Flushing Compressor Product Data Sheet F 02

swimming pool technology

Integral type Differential pressure flowmeter VNT Series

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL

TECHNICAL ACCESSORIES

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

2008 by Controlmatik ABW

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

MMS Mercury Monitoring System for Natural Gas

Quick Installation Guide Doc nr.: C Date:

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Installation and maintenance of twin 45kg LPG cylinder systems

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Chemical Injection Technologies Installation/Service Bulletin

Section GAS CHLORINATION SYSTEM

Products for Cryogenic Applications

Additional sheet to leaflet Pressure regulators with safety assemblies, Print No Inlet pressures up to max. 1 bar Page 2

Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

Compressed Airline Breathing Apparatus

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

ACV-10 Automatic Control Valve

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Gas Injection Systems

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Dräger Quaestor 7000 Test Equipment

Dräger NITROX 200 Diving Equipment

How to specify a product. Process Sensors and Mechanical Instruments

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Pneumatic high-pressure controller Model CPC7000

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Valve Proving System VDK 200 A S02

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Valve Proving System VDK 200 A S06*

Pressure ranges and accuracy classes for outlet pressure and safety devices

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Air preparation units

PHOENIX L300i Best-in-class Helium Leak Detectors

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

RH800 & 2000 BASIC OPERATIONS

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

C Operation & Maintenance Instructions EN 02. Vacuum Regulator for Chlorine Gas. Dosing Conveying Control

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Columbus Instruments

Air service units series K G1/8, G1/4

Air-service devices, Series MU1

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

Dräger ABIL-L Airline Equipment

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

MANAGEMENT IN WATER.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Type 4708 Supply Pressure Regulator

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Glass tube flowmeters Series 2000

C Operation & Maintenance Instructions EN 02. Vacuum Regulator for Chlorine Gas. Dosing Conveying Control

Actuator HON 670 / 671

High Pressure Breathing Air Compressors

The number of test stands can be adapted to the special requirements.

Transcription:

A measured step forward Large-Scale Chlorinator and Accessories Dosing Conveying Control Liquids Gases Systems

Water is precious. The more consumption increases due to public, industrial and domestic use, the more crucial it becomes to treat the water for reuse. Disinfection as the final treatment stage plays a particularly important role in this process. The responsible introduction of disinfectants into the water requires reliable dosing technology. As a result of profound research and development in this area, Lutz- Jesco has created system solutions which apply internationally. We give water the right quality for use. Different methods are applied for disinfecting water. They differ in the configuration of the equipment and the type of chemicals used. Due to their easy application and effectiveness, chlorine and its compounds have been used successfully for many decades in water treatment. We have specialized in chlorine dosing technology. Our range of approved equipment for dosing chlorine gas under vacuum or liquid chlorine compounds is as comprehensive as the versatility of the individual tasks. With their well-matched components, Lutz-Jesco chlorinators meet all requirements from chlorination to analyzing and detecting equipment, which can be expected from a state-of-the-art installation. They stand out for their reliability and repetitive dosing accuracy. Our systems corresponding to DIN and international standards ensure an optimum water quality due to exactly rated disinfection. We contribute our know-how and experience to provide the best solution technically and economically. In addition to the quality of our precision equipment, our know-how is a key factor for the success of our customers. Worldwide. 4 5 1 2 3 Installation of a water disinfection system Installation under pressure 1. Chlorine barrel 2. Barrel balance 3. Expansion cylinder, expansion piping 4. Excess pressure blowoff line 5. Automatic single barrel changeover unit for liquid chlorine 6. Automatic evaporator changeover unit 7. Chlorine evaporator 8. Chlorine gas filter, pressure reducing valve, gauge with pressure switch, quick-action stop valve 9. Vacuum regulator Installation under vacuum 10. Chlorine gas supply line 11. Automatic chlorinator for prechlorination 12. Standby for item 11, automatical 13. Standby for item 11, manual 14. Automatic chlorinator for postchlorination 15. Standby for item 14, automatical 16. Standby for item 14, manual 17. Ejector for prechlorination, automatic chlorinator, automatic standby and manual standby 18. Ejector for postchlorination, automatic chlorinator, automatic standby and manual standby 19. Booster pump, automatic chlorinator, automatic standby and manual standby 2

Lutz-Jesco Chlorination Systematized Chlorine Applications 8 6 10 18 17 7 9 19 16 14 15 13 11 12 3

Chlorinators Fully developed, safe, reliable Chlorine and chlorine compounds have been used successfully in water treatment for many decades. Lutz-Jesco offers you an extensive range of well-established equipment as well as of state-of-the-art chlorination systems for dosing chlorine gas and chlorine compounds reliably and precisely. Chlorinator, analyzing and detecting devices match perfectly. Lutz-Jesco chlorination units meet the safety requirements according to German standard DIN 19606 by full vacuum technology. In short User-friendly Easy handling Increased dosing accuracy High working reliability For an optimum automation level Modular disinfection Chlorinators C 2525 and C 2700 follow a clear modular structure. Whether we are talking of a compact unit with all functions integrated in a free-standing cabinet or of functional modules for your individual installation setup a reliable vacuum system will always be at your disposal. In short Suitable for up to 5 and 200 kg Cl 2, respectively With separate vacuum regulator Sturdy and precise The C 7700 is the final control element in automatically operated chlorination installations working according to the vacuum method. It impresses by its reliability and linear characteristic curves. The valve is suitable for proportional dosing as well as for automatic control systems. In short Control range from 0 80 g Cl 2 to 0 200 kg Cl 2 Dosing without any break You like it perfectly automatic, don t you? In this case C 7520 and C 7522 are just the right devices for you: automatic changeover valves for uninterruptable chlorine gas supply. Microprocessor-controlled and motor-driven. Equipped with relay contacts for remote monitoring. 4 In short C 7522: vacuum version up to 100 kg Cl 2 C 7520: pressure version up to 200 kg Cl 2

Vacuum Chlorinators C 2525 vacuum chlorinators C 2525 chlorinators These chlorinators have been designed as vacuum units according to German standard DIN 19606. Versions for other gases (CO 2, NH 3, SO 2 ) available on request. C 2525 V Vacuum regulator up to 25 kg Cl 2 Supplied as a separate unit with an optional pressure gauge. A safety blowoff valve is integrated in the device. C 2525 WL For wall mounting up to 25 kg Cl 2 The equipment is fixed to a plate for wall mounting. Consisting of: Flow meter Adjusting valve Backpressure regulator Vacuum gauge Automatic control valve as an option Type C 2525 Capacity kg Cl 2 Vacuum connection mm WL5 0.25 5 8/12 tubing WL10 0.50 10 12/16 tubing WL15 0.75 15 12/16 tubing WL25 1.25 25 screwed PVC-connection d 20 Dimensions: Plate for wall mounting H x W 900 x 490 mm Weight: approx. 16 kg C 2525 SL Installed in a free-standing cabinet for up to 25 kg Cl 2 The equipment is built in a cabinet. Consisting of: Flow meter Adjusting valve Backpressure regulator Vacuum gauge Automatic control valve as an option Type C 2525 Capacity kg Cl 2 Vacuum connection mm SL5 0.25 5 8/12 tubing SL10 0.50 10 12/16 tubing SL15 0.75 15 12/16 tubing SL25 1.25 25 screwed PVC-connection d 20 Dimensions: Cabinet H x W x D 1,600 x 700 x 360 mm Weight: approx. 35 kg 5

Vacuum Chlorinators C 2700 vacuum chlorinators C 2700 chlorinators These chlorinators have been designed as vacuum units according to German standard DIN 19606. Versions for other gases (CO 2, NH 3, SO 2 ) available on request. C 2700 V Vacuum regulator up to 200 kg Cl 2 Supplied as a separate unit with an optional pressure gauge. A safety blowoff valve is integrated in the device. C 2700 WL For wall mounting up to 200 kg Cl 2 The equipment is fixed to a plate for wall mounting. Consisting of: Flow meter Adjusting valve Backpressure regulator Vacuum gauge Automatic control valve as an option Type C 2700 Capacity kg Cl 2 WL40 2 40 d 50 mm WL60 3 60 d 50 mm WL120 6 120 d 50 mm WL200 10 200 d 50 mm Vacuum connection screwed PVC conn. Dimensions: Plate for wall mounting H x W 810 x 645 mm Weight: approx. 24 kg C 2700 SL Installed in a free-standing cabinet for up to 200 kg Cl 2 The equipment is built in a cabinet. Consisting of: Flow meter Adjusting valve Backpressure regulator Vacuum gauge Automatic control valve as an option Type C 2700 Capacity kg Cl 2 SL40 2 40 d 50 mm SL60 3 60 d 50 mm SL120 6 120 d 50 mm SL200 10 200 d 50 mm Vacuum connection screwed PVC conn. Dimensions: Cabinet H x W x D 1,600 x 700 x 360 mm Weight: approx. 49 kg 6

Chlorinators Flow meters, C 7700 chlorine control valves, C 7520 changeover valves Flow meter For precise reading of the current chlorination performance. With adjusting valve for manual setting of the dosing rate. Length of measuring glass 300 mm. Measuring ranges: 0.25 5 kg Cl 2 0.50 10 kg Cl 2 1.75 15 kg Cl 2 1.25 25 kg Cl 2 2 40 kg Cl 2 3 60 kg Cl 2 6 120 kg Cl 2 10 200 kg Cl 2 C 7700 Chlorine control valve (ATE) control ranges up to 200 kg Cl 2 C 7700 chlorine control valves are electrically adjustable plastic control valves for chlorination under vacuum. They allow a continuous proportional chlorination and are used as a final control element in automatic control systems. A servomotor is used as drive. The unit is controlled either by a three-point step controller or a 4... 20 ma output. The chlorine gas flow rate is proportional to the control variable. The valve can be set to position Open to enable manual dosing. C 7520 Automatic changeover valve for chlorine gas and liquid chlorine under pressure up to 200 kg Cl 2 As a standard two chlorine gas supply units (cylinder or barrel batteries) are provided for chlorination installations. This is the only way to operate the plant automatically 24 hours per day. A changeover valve is required to switch over automatically to the standby battery. Available on a plate for wall mounting or as a kit including the individual components. The changeover unit consists of a microprocessordriven changeover control allowing also manual operation and display of all conditions by means of bright LEDs, a contact vacuum gauge as well as two separate motor ball valves allowing manual emergency operation. The C 7520 changeover valve is fitted with relay contacts for remote signaling in the case of an empty tank. In the case of chlorine gas leakage, both valves can be shut off by means of a gas detector or manually at the changeover control. 7

Chlorinators C 7522 changeover valves, ejectors, C 6100 chlorine evaporator C 7522 Automatic changeover valve for chlorine gas under vacuum up to 100 kg Cl 2 As a standard two chlorine gas supply units (cylinder or barrel batteries) are provided for chlorination installations. This is the only way to operate the plant automatically 24 hours per day. A changeover valve is required to switch over automatically to the standby battery. Available on a plate for wall mounting or as a kit including the individual components. The changeover unit consists of a microprocessor-driven changeover control allowing also manual operation and display of all conditions by means of bright LEDs, a contact vacuum gauge as well as two separate motor ball valves allowing manual emergency operation. The C 7522 changeover valve is fitted with relay contacts for remote signaling in the case of an empty tank. The residual emptying facility ensures that the chlorine tanks are fully emptied by switching back to them periodically. If higher chlorine consumption is required temporarily, both chlorine gas tanks can be used at the same time (shock chlorination). Vacuum connection as d 32 mm cemented connection, adapter with tubing connections available. Changeover time: max. 25 seconds. Ejectors with non-return valves Ejectors generate the vacuum required for vacuum systems and cause a homogenous mixing of the chlorine solution. This is the only way to ensure reliable disinfection. Lutz-Jesco ejectors are produced precisely and offer optimum performance at minimum energy consumption. Ejectors can be supplied for all dosing rates up to 200 kg Cl 2 in PVC or rubber-coated cast iron, depending on the application. Ejector non-return valves reliably prevent water from entering the dosing unit. C 6100 Evaporator for liquid chlorine applications Evaporative power up to 220 kg Cl 2 With the C 6100 chlorine evaporator, permanently much more than 1% of the chlorine contents can be taken per hour from the tank and converted into gas. The evaporation process takes place in the heated chlorine evaporator. The chlorine supply just has to be rated as to allow to exchange the tanks at appropriate intervals. Advantages: Reduction of danger potentials due to a minimum number of open chlorine barrels Maximum temperature of 100 C, as water is the heat carrier Cathodic protection against corrosion Pipe coil construction with large heat transfer surface No circulating pump required Highest possible safety standard 8

Accessories Valves, manifolds, expansion cylinders, filters Matching combination Even the best chlorination system can still be improved namely by the right technical periphery, which, in fact, is the reason for the particularly comprehensive accessories program of Lutz-Jesco. It converts your chlorinators into an efficient dosing system. Auxiliary valves Auxiliary valves are required to change the chlorine tanks safely. Lutz-Jesco supplies these units for all standard tank valves. Manifolds To allow increased chlorine supply volumes or longer rate times, several chlorine tanks are combined in a battery. For chlorine under pressure, manifolds for up to eight tanks are available. The manifolds for gas supply have an integrated mist collector which can be fitted with an electrical heating. All manifolds are suppplied with flexible connection lines and shuttoff valves. They are corrosion-proof and coated with epoxy resion. Solid fastening material is also included in the scope of delivery. Expansion cylinders When withdrawing or using liquid chlorine, expansion cylinders must be installed into the lines to protect the system against extremely high pressures. An expansion cylinder must be provided wherever liquid chlorine may be entrapped between two shutoff elements. Depending on the line volume, the expansion cylinders are supplied in different sizes with or without rupture disk and contact pressure gauge. Filters Filters are installed into the pressure lines to protect the dosing units against dirt. The filters are fitted with a ceramic filter element with a pore size of 30 µm and retain dirt particles and liquid chlorine droplets. The filters are suitable for a chlorine gas flow rate of up to 200 kg. 9

Accessories Valves, more accessories Pressure reducing valves Inlet pressure up to 15 bar Outlet pressure 0.5 2.5 bar Up to 200 kg Cl 2 Pressure reducing valves are mainly used to prevent chlorine reliquefaction so that the destruction of PVC parts is avoided. The pressure is reduced to a level which ensures that chlorine reliquefaction would occur in the subsequent line at far less than 0 C only. These temperatures are not permitted for chlorination rooms. More accessories for your chlorination system Fastening material Pipe fittings Pressure gauges and vacuum gauges Special tools Process and commodity materials such as erection paste or ammonia solution 10

Auxiliary and safety equipment Success with a pattern All equipment needed for a perfect chlorination room Auxiliary equipment Fixing devices for cylinders and barrels Sling devices, e.g. crane trolleys, chain hangers Crane balances to determine the tank contents Room heatings Ammonia solution Personal protective equipment (Compressed air) breathing apparatus independent of circulating air Full-view gas mask Protective clothes Safety equipment Gas detector to monitor the chlorine concentration in the room air Water sprinkling systems to condense chlorine in the room air Labeling (warn signs, short operating instructions) Showers for body and eyes Emergency kits for chlorine cylinders or barrels Barrel balances The actual contents of a chlorine tank can only be determined by measuring the weight. The residual contents of a chlorine tank is of decisive importance for continuous, uninterruptable chlorination. The barrel balance is fitted with a safe barrel rest and allows to read the chlorine contents from a digital or analog display unit. Available as single or duplex barrel balance. 11

Product range Lutz Pumpen GmbH P.O. Box 1462 D-97864 Wertheim www.lutz-pumpen.de Product range Lutz-Jesco GmbH P.O. Box 100164 D-30891 Wedemark www.lutz-jesco.com Barrel and container pumps Dosing pumps Measuring and control equipment Flow meters Chlorinators Disinfection Double diaphragm pumps Chemical centrifugal pumps Standard plus Centrifugal pumps Products for the disinfection of swimming pool water based on salt water electrolysis and domestic water technology The Lutz-Jesco App for ipad and iphone is available from the itunes App Store. Further information can be found at www.lutz-jesco.com Head Office Lutz-Jesco GmbH Am Bostelberge 19 30900 Wedemark Germany Hungary Lutz-Jesco Üzletág Vasvári P. u. 9. 9024 Györ Hungary Austria Lutz-Jesco GmbH Aredstraße 7/2 2544 Leobersdorf Austria Netherlands Lutz-Jesco Nederland B.V. Nijverheidstraat 14 C 2984 AH Ridderkerk Netherlands Tel.: +49 5130 5802-0 Fax: +49 5130 580268 Tel.: +36 96 523046 Fax: +36 96 523047 Tel.: +43 2256 62180 Fax: +43 2256 6218062 Tel.: +31 180 499460 Fax: +31 180 497516 E-mail: info@lutz-jesco.com Website: www.lutz-jesco.de E-mail: info@lutz-jesco.hu Website: www.lutz-jesco.hu E-mail: info@lutz-jesco.at Website: www.lutz-jesco.at E-mail: info@lutz-jesco.nl Website: www.lutz-jesco.nl P0004-02-V05 Copyright 04.2014 by Lutz-Jesco GmbH Subject to technical changes Great Britiain Lutz-Jesco (GB) Ltd. Gateway Estate West Midlands Freeport Birmingham B26 3QD Great Britain Tel.: +44 121 782 2662 Fax: +44 121 782 2680 E-mail: info@lutz-jesco.co.uk Website: www.lutz-jesco.co.uk USA Lutz-JESCO America Corp. 55 Bermar Park Rochester, N.Y. 14624 USA Tel.: +1 585 426-0990 Fax: +1 585 426-4025 E-mail: mail@jescoamerica.com Website: www.lutzjescoamerica.com East Asia Lutz-Jesco East Asia Sdn Bhd 6 Jalan Saudagar U1/16 Hicom Glenmarie Industrial Park 40150 Shah Alam/ Selangor Malaysia Tel.: +603 55692322 Fax: +603 55691322 E-mail: info@lutz-jescoasia.com Website: www.lutz-jescoasia.com Middle East Lutz-Jesco Middle East FZE P.O. Box 9614 SAIF-Free Zone Center Sharjah UAE Tel.: +971 6 5572205 Fax: +971 6 5572230 E-mail: info@jescome.com Website: www.jescome.com