Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

Similar documents
V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

V10K GAS FEED SYSTEM

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Highest Quality. Gas Chlorination Systems

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

ACV-10 Automatic Control Valve

Section GAS CHLORINATION SYSTEM

Chlorinator MODEL MK-I

VACCUPERM Vacuum chlorine gas dosing systems

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Full-Vacuum Chlorinator C 2212 MB / 1

BULLETIN 901 SAFE RELIABLE ECONOMICAL REGAL GAS CHLORINATORS SULPHONATORS AMMONIATORS

Chlorinator. MODEL C-731 (Floor Mounted)

Chemical Injection Technologies Installation/Service Bulletin

Variable Area Flow Meters

ProMinent Gas Chlorination

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Model 130M Pneumatic Controller

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Description Advanced Features Typical Applications

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Columbus Instruments

Measurement of Low GAS & Liquid Flows

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MEDICAL EQUIPMENT CATALOG

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Autocalibration Systems For In Situ Oxygen Analyzers

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Series 2G Diaphragm Actuators

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

TECHNICAL DATA. Q = C v P S

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Royce Interface Level Analyzer and Sensors

TECHNICAL DATA. Q = C v P S

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

The Ins and Outs of I/P Transducers

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

Model VR6 System. Installation, Operation & Maintenance

Model 4000 Pressure Controller

TECHNICAL DATA. Trimpac 244a. September 16, 2013

[Instruments for vacuum measurement, checking and adjustment] 3

Vaporizer Piping Liquid Chlorine Manifolds

AUTOMATIC GAS MANIFOLDS

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

RCD - Ultra-Rugged Differential Pressure Flowmeter

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

TECHNICAL DATA. Q = C v P S

Installation, operating and maintenance Instructions for Seemag bypass level indicator

VACUUM REGULATORS CONTENTS

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Rejuvenation Instructions

553 Series.

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

HumiSys HF High Flow RH Generator

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Porter Analytical & Industrial Products

FAULT CODE TROUBLESHOOTING INDEX

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Basic & Controlled Atmosphere Glove Boxes

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

FX134, FX1234, FX3030 Problem and Solutions

DPC-30 DPC-100. Reference Manual

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

High Precision Gauge Pressure Indicators

RK-IR Sample Draw Aspirator Adapter Operator s Manual

How to specify a product. Process Sensors and Mechanical Instruments

MATHESON s LaserPro Gases and Gas Delivery Equipment

Technical Service Bulletin March 2015 TSB142.01

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Additel 761 Automated Pressure Calibrators

TECHNICAL DATA. Q = C v P S

Design Features. General Description

A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE

Constant Pressure Inlet (CCN) Operator Manual

HGC-200 Hydro Gas Chlorinator

2008 by Controlmatik ABW

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Pneumatic dead-weight tester Model CPB3500

TECHNICAL DATA. Q = C v P S

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

IFP C175-* REMOTE CONTROL RELIEF VALVE

NGP-250/500 Nitrogen Generator Quick Start Guide

Aquavar SOLO 2 Frequently Asked Questions

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

Transcription:

Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

OVERVIEW V10k - THE NATURAL EVOLUTION OF THE WORLD S BEST CHLORINATOR The V10k is a remote vacuum solution feeder for use with four of the most commonly used gases for the disinfection and treatment of municipal and industrial water and wastewater. This unit has been built to continue the long standing proven design and features of its predecessor and adds more. The versatility of wall mounting, front access of all components and maximum capacity of 500PPD (chlorine) have all been enhanced by this new design. The V10k gas feed system consists of a vacuum regulator mounted at the gas supply, a wall-mounted gas control unit with a rotameter for indication of feed rate and a water-operated injector that provides the vacuum source to drive the entire system. Using automatic switchover regulators, the V10k provides an uninterrupted supply of gas to maintain continuous disinfection/treatment. Versatility a wall-mounted gas feeder available in a configuration to meet your water treatment requirements. Proven V-Notch Flow Control Technology for accuracy and repeatability. Premium Construction features a onepiece molded headblock for reliability and endurance. Large 5" and 10" Rotameters -- available in 13 capacities up to 500PPD Cl 2 for the highest degree of readability. Serviceability components easily accessible for servicing without tools. Flexible Control Modes manual to fully automatic control schemes. Differential-Type Regulation allows for lower vacuum levels and efficient, economical injector operation. Handles All Water Treatment Gases Chlorine, Ammonia, Sulfur Dioxide and Carbon Dioxide. TYPICAL APPLICATIONS Typical Industries Typical Applications, Metering & Pumping Municipal or Industrial Water Treatment Disinfection of potable water Treatment of cooling water to inhibit biological growth and algae control in irrigation systems Municipal or Industrial Disinfection of municipal sewage effluent Waste Treatment Chemical Processing Treatment of industrial wastes from: - metal finishing - pulp and paper operations - chemical plants - food processing plant discharges Industrial Process Water Taste and odor control in bottling plants and breweries Tempering water treatment and bleaching in flour mills High purity water in: - electronics - pharmaceuticals - cosmetic industries Swimming Pools Swimming pool disinfection CO 2 feed for ph control 2

FEATURES V-NOTCH GAS FLOW The V-Notch control orifice, field-proven in hundreds of thousands of installations around the world, provides reliable, consistent gas feed at any capacity requirement. It consists of a precision grooved plug that slides through an annular seat. Any position of the plug in the seat results in a specific orifice size and a corresponding feed rate. The large size and configuration of the orifice resists fouling from contaminants in the gas supply. This results in accurate gas flow control and excellent repeatability. Control of this V-Notch can be from simple manual operation up to sophisticated automatic control schemes. SAFE, ALL VACUUM OPERATION The complete V10k gas feed system operates under a vacuum. A vacuum-regulating valve at the gas supply container reduces gas pressure to a vacuum at once. Dry gas moves through the system to the injector under vacuum. If at any time a leak occurs from a loose fitting or an accidentally cut line or tubing, the loss of vacuum causes the system to shutdown without releasing gas to the atmosphere. CONVENIENT, WALL MOUNTED DESIGN The V10k system is designed for the operator s convenience. Unlike cylinder mounted gas feeders, the control unit is mounted securely on the wall. This provides a stable control platform that simplifies the installation of gas and electrical lines and protects the fragile rotameter from constant handling every time the gas supply is changed. EASY READABILITY Scale shown actual size. AUTOMATIC SWITCHOVER BUILT-IN The use of large rotameters provides the highest degree of resolution for accurate indication of feed rate, unmatched by any other manufacturer in a similar capacity chlorinator. The forward location of the rotameter and the white background of A pair of vacuum-regulating valves provides automatic switchover to a fresh supply when the on-line supply is exhausted. There is no need for a separate switchover device to take up room and complicate installation. An additional benefit is non- the mounting frame enhance the resolution. Wall mounting the unit puts the rotameter at a convenient height for the operator. Gas feed accuracy is +/- 4% of the indicated flow. isolating operation. This allows gas to continue to be withdrawn after switchover from the previous supply until the container is empty. 3

OPERATION The V10k gas feed system operates under a vacuum that is produced at the injector and transmitted through the control unit to the vacuum regulating valve located at the gas supply. Gas enters the vacuum regulating valve and moves toward the flow control components under a vacuum. Gas next passes through the rotameter, where its flow rate is measured and the V-Notch orifice, where feed rate is controlled manually or by an automatic positioner. At the injector, the metered gas is dissolved in the water stream. The resultant solution is discharged to the point of application. 1 Vacuum Regulators Vacuum regulating valves, mounted on the gas supply containers, immediately reduce the pressurized gas to a vacuum. Two capacity regulators are available for both standard and switchover applications: 200PPD and 500PPD. These regulators feature: Rugged Construction Inlet components are made of metal to withstand full supply pressure. Molded PVC housings endure rough handling as well as resist corrosion. Positive Indication of Operating Status A unique lever mechanism and front panel knob provide the operator with a quick indication of 3 or 4 operation 4 modes (operating, low gas supply, off, and standby for automatic switchover arrangements). An additional built-in red indicator becomes visible in the low/out-of-gas situation and an optional contact is available for remote indication. Secondary Pressure Check The 500PPD regulator has a unique, builtin additional check valve, designed to confine gas under pressure should dirt build up on the primary valve seat. Local or Remote Vent Valve The pressure relief vent is built into the regulator housing to keep all vent lines in the gas supply room. If desired, the vent can be relocated away from the regulator to satisfy specific application requirements. 2 Rotameter Large scale, 5" and 10" rotameter tubes provide clear and accurate indication of feed rate. With 13 capacities available in each size, you can have a rotameter closely scaled to your exact feed requirements. 3 Differential Regulating Valve Maintains the proper vacuum differential across the V-Notch orifice for consistent feed rate, regardless of changes in operating vacuum. 4 Automatic Positioner For automatic control, this positioner moves the V-Notch plug up to 3" (compared to a fraction of an inch for competitive systems) in precise response to the application requirements. Features include: NEMA 4X enclosure Manual override is achieved by simply pulling the knob to disengage the drive motor. Three sets of customer contacts for system interface: Manual Override, MAX position and MIN position. Internal feedback potentiometer for precise operation with the SCU or PCU controllers. 5 Vacuum Gauge Provides indication of operating vacuum level. A direct acting diaphragm mechanism eliminates liquid filled chambers. A green colored band tells the operator when the vacuum is the correct range. 6 Injectors Fixed throat, differential-type injectors create a powerful operating vacuum to drive the V10k system. Two capacity injectors are available: 3/4" for capacities up to 200PPD and 1" up to 500PPD. These injectors feature: Built-in Double Check Valves for superior protection against backflooding. A spring-loaded diaphragm with

a spherical seat for positive sealing and a spring-loaded poppet check work together to maintain system integrity. Flexible Mounting Orientation for convenient installation. The gas inlet connection can be rotated to provide pipe entry at selected angles. The injector can also be mounted in horizontal or vertical planes. It features an integral-mounting bracket and can be disassembled for service without removal from the wall or disconnecting the inlet/outlet piping. Anti-siphon Arrangement for swimming pools and negative backpressure applications. For the 1" injector, this option is a cartridge that fits into the standard injector housing. The 3/4" injector utilizes an additional rear housing for anti-siphon operation. 7 Vacuum Switch A local or remote mounted vacuum switch provides an alarm in the event of a high or low vacuum condition signifying a loss of gas feed. 2 5 200 PPD Regulator 1 3 1 Injector 500 PPD Regulator 6 3/4 Injector 4 7 5

CONTROL METHODS Feed rate of any V10k Chlorinator is controlled by either one or both of these methods: interrupting the injector-water supply to shut off the chlorinator s operating vacuum; changing v-notch-orifice area (by positioning the v-grooved plug in its ring) while holding vacuum differential across the orifice constant. MANUAL CONTROL Manual control by changing orifice area (v-notch-plug position) via an adjustment knob on the chlorinator. START-STOP OR PROGRAM CONTROL This type of control is achieved with simple implementation. A V10k Chlorinator s operating vacuum is started and stopped by interrupting the injector water supply. A solenoid valve or motorized valve is wired into the control circuit of a pump, switch, controller, or timer. Similar to this, a special vacuum line solenoid valve can be used in the gas line to the injector. SCU SIGNAL CONDITIONING UNIT The economical SCU gives automatic process control in response to one process variable, typically flow rate. Housed in a NEMA 4X enclosure, the SCU features an 8-character alphanumeric LCD display with 6-button keypad and menu-driven operator prompts for simple operation, setup and calibration. Input flow scaling and output dosage adjustments allow independent scaling from 10 to 400%. See publication TI 40.100UA for more details. PCU PROCESS CONTROL UNIT The PCU is a full feature setpoint controller. It provides automatic process control in response to two process inputs, typically flow rate and chlorine residual. The PCU can operate in any of four different control modes including residual feedback, compound loop, dual signal feed forward (for dechlorination) and flow proportional. In addition, the PCU can be configured for "center-zero" operation in compound loop mode when a DEOX/2000 Dechlorination Analyzer is used. Housed in a NEMA 4X enclosure, the PCU features a large alphanumeric display, an LED bargraph to indicate flow input or actuator position in 5% increments, a 6-button keypad and menu driven operator prompts for simple operation, setup and calibration. For more information request publication TI 40.200UA. 6

TECHNICAL DATA Accuracy maximum feed rate, the diameter of the Options Gas feed is +/-4% of the indicated flow. connecting pipe or tubing and system Gas Flow Transmitter performance requirement. Non-inferential measurement of the rate Operating Range of gas flow through any V10k gas feeder. Manual 20:1 for any rotameter; Injectors Consists of a NEMA 4X sensor trans- Automatic 10:1. For capacities up to 200 mitter with a 4-20 ma output directly PPD, a 3/4" injector is proportional to gas flow. See Technical Rotameters used. For capacities up to Information publication TI 50.114. Choice of 5" or 10" scale length. 500 PPD, a 1" injector is used. Injectors can be panel 1 500PPD Automatic Switchover Operating Vacuum mounted or remote. A pair of vacuum-regulating valves 10 to 50" water. Injector Operating Water designed to switch to a fresh gas supply This must be reasonable from an empty container. Operating Temperature Range 10 to 130 F (-12 to 55 C) clean. Injectors are fixedthroat differential type. 3/4 200PPD Ton-Container Kit Maximum inlet pressure is 300 psi to Adapts the vacuum-regulating valve for Mounting 100 F; 150 psi to a maximum of 130 F. mounting on a ton container for gas with- Wall or panel mounted. Panel mounted drawal. It has a drip leg to trap initial spurts arrangement can be configured with a Pressure at Application Point of liquid and a heater to evaporate them. panel mounted injector or a panel Maximum pressure with hose or polyeth- mounted controller (for automatic con- ylene tubing is 75 psi, but high-pressure Vacuum Switch trol version). An optional vacuum switch hose or rigid pipe will allow application A low vacuum switch or a high, high/low can also be mounted on the panel. against backpressure of 75 to 160 psi. A vacuum switch is available to indicate loss solution pump after the injector will of gas feed. Each switch contains two, Control Modes allow application against higher pressure. s.p.s.t. contacts rated 5 amps at 250V Manual control, start-stop or program, flow proportional, direct residual and Electrical Requirements Anti-Siphon Injectors compound-loop control. Controller requires 120 volts +/- 10% (200 For swimming pool applications or ma) or 230 volts +/- 10% (100 ma), 50/60 applications where there is a negative Distance, Supply to Control Panel Hz, single phase. There may be other backpressure, 3/4" or 1" anti-siphon For flexibility, it is not necessary to install requirements; solenoid valves for start-stop injectors are required. These injectors the vacuum regulating valve close to the operation, solution or booster pumps. require a minimum inlet water pressure control panel. They can be a few feet to of 20 psi for operation. several hundred feet apart, depending on 7

TECHNICAL DATA Related Options Related options include: cylinder and ton container valves and connections; header valves with manifolding and connections; vent, injector-water and injector outlet lines and clamps; main connections; solenoid valves; waterline pressure gauge; gas mask; on-line residual analyzers; residual test kits; injector vacuum gauge; spare parts; booster pumps; chlorine detector; two cylinder scale. Compliance Gas feeder, controller and actuator are designed to conform to all applicable NEC and NEMA specifications and Chlorine Institute and Compressed Gas Association recommendations. Overall Dimensions Chlorinator: Panel mounted: manual: 34 5/8" X 17" X 7 5/16" automatic 34 5/8" X 17" X 10" Wall mounted 5": 12 3/8" X 13 7/16" X 6" 10": 19 7/8" X 13 7/16" X 6" Controller SCU: 8 3/4" X 6 1/2" X 3 5/8" PCU: 8 3/4" X 6 1/2" X 9 1/8" Shipping Weight Wall mounted units 10 lbs Panel mounted units 20 lbs manual 25 lbs automatic Chlorine Gas Warning All unattended chlorine gas containers and chlorination equipment should be monitored for leaks. Sensitive chlorine detectors, which respond quickly to chlorine in the atmosphere, should be installed at each site. Request Wallace & Tiernan Products publications TI 50.130UA. Carbon Dioxide Warning Because of the high pressure in carbon dioxide containers, the vacuum regulating valve cannot be mounted directly on the cylinder. A pressurereducing valve must be installed between the cylinder and the vacuumregulating valve. Gases and Capacities* Maximum Chlorine Carbon Dioxide Sulfur Dioxide Ammonia capacity lb/24 hour lb/24 hour lb/24 hour lb/24 hour 5 & 10 3/10/20/30/50 2.4/8/15/24/35/ 3/10/20/30/50/ 1.4/4.5/9/14/24/ 200 PPD 75/100/150/200 58/75/116/150 75/100/150/200 35/45/70/95 3/10/20/30/50/ 2.4/8/15/24/35/58 3/10/20/30/50/ 1.4/4.5/9/14/24/ 5 & 10 75/100/150/200/ 75/116/150/ 75/100/150/200/ 35/45/70/95/120/ 500 PPD 250/300/400/500 200/230/300/390 250/300/400/475 140/190/240 * A selection of tubes is also available in metric calibrations. Connections Pipe and plastic tubing sizes given Vacuum Regulating Valves Tubing to 200 lb 500 lb control panel 3/8 x 1/2 1/2 x 5/8 gas inlet is yoke connection container to a cylinder or header valve valve or, with optional adaptor, to a ton container valve Injectors Connection 200 lb 500 lb water inlet 3/4 male NPT or 1 female NPT 3/4 flexible pipe water outlet same as inlet 3/4 NPT with adapters for 3/4 1, or 1-1/2 pipe or hose Due to continual product development and improvement, certain specifications may change without prior announcement. Taking care of the world s water. Wallace & Tiernan/Stranco Unit A1, 6-8 Lyon Park Rd, North Ryde usf@usf.com.au email 02 8875 2800 tel 02 8875 2700 fax www.wtpacific.com.au Literature #SB 25.100UA Revised 11/99 1999 United States Filter Corporation