Polarimeter tubes and accessories

Similar documents
better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Rotary Viscometers Rotary viscosimeters ST-2020

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Density2Go. Hydrometers Pycnometers Digital Hydrometers. 3 Ways to Measure Density Know-How, Hints, and More

Pneumatic high-pressure controller Model CPC7000

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Precision pressure sensor Basic version Model CPT6020

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pressure Calibrators. Series PC..., PM...

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

Additel 761 Automated Pressure Calibrators Selection Guide

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Tensiometer For the measurement of surface and interfacial tension

SAUTER FK Version /2016 GB

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Optical Dissolved Oxygen Meter

Tensiometer For the measurement of surface and interfacial tension

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

Pneumatic high-pressure controller Model CPC7000

deltaflowc deltaflowc Venturi or Probe

Pneumatic service kit Model CPG-KITP

Rotational Viscometers RP1 RP2

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

DTG - LCD Digital Temperature Gauge USER MANUAL

Additel 761 Automated Pressure Calibrators

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Insertion Tubes. for temperature dry-blocks. temperature

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Torque Tube TB300 Digital Transmitters

Laboratory Mortar Mixer (Testing)

CO2 incubator with additional process controls

Transferpette -8/-12

Microscopy Cryogenic WORKSTATION. Performance by Design

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Thermochemistry/Calorimetry. Adiabatic coefficient of gases Flammersfeld oscillator LEC 02. What you need: What you can learn about

BOYLE S / CHARLES LAW APPARATUS - 1m long

Operating instructions Installation instructions To be kept in the vehicle!

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Digital pressure gauge Model CPG500

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

UT 3000 Mercury Ultratracer

CO2 incubator with additional process controls

CO2 incubator with additional process controls

Optical Dissolved Oxygen Meter

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

DENSITY CALIBRATIONS AT MIKES. Heikki Kajastie, Jorma Manninen and Kari Riski Centre for Metrology and Accreditation (MIKES) ABSTRACT

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Battery Powered Thermal Mass Flow Meters for Gases

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Instruction Manual Dräger MSI P7 and MSI P7 plus

Calibration equipment

Operating manual Analogue Brix Refractometer

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

We measure it. For gas and water installers. testo hpa. bar

Pool and Spa. Water Testing

Technical Information Conducal CLY421

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Additel 761 Automated Pressure Calibrators

FPG8601 Force Balanced Piston Gauge

Pressure calibration equipment

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Peak Pressure Indicator MSI-3

Expansion Thermometers Stainless Steel Series, Model 70

Operating manual for the pressure transducer unit CCS 1000

628 Differential Pressure Decay Leak Tester

Digital Melting Point Apparatus

High-speed pressure sensor Model CPT6140

Precision Liquid Settlement Array Manual

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Product Information. Tolerance compensation unit TCU-Z

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Columbus Instruments

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

HI 2314 HI 2315 HI 23151

OUS31. Technical Information

Bull s-eye Levels and Screw-On Levels

Elcometer 2300 Rotational Viscometers. elcometer.com

Best Practice for Calibrating LTH Conductivity Instruments

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

Constant Pressure Inlet (CCN) Operator Manual

HBLT-A1 LIQUID LEVEL SENSOR

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Calibration equipment

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Pneumatic dead-weight tester Model CPB3500

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

T h e h a n d y L A U D A B u b b l e P r e s s u r e Te n s i o m e t e r M P T C a l s o r e c o r d s f a s t s u r f a c t a n t s i n m i l l i

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

Digital pressure gauge Model CPG500

Mini Water Flow Regulators

Fluid Machinery Introduction to the laboratory measurements

AUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed

Translation of the original Operating Instructions for HKS rubber compensators

Transcription:

Polarimeter tubes and accessories Opto-electronic measuring device since 1864

Polarimeter tubes of SCHMIDT+HAENSCH are designed for different applications. All tubes meet the ICUMSArecommendations, class A (±0.01%) and the corresponding specifications of the O.I.M.L. and the Australian Standard K 157 regarding of construction and precision. Hints for the choise of tube length In general: Longer measuring tubes are better than short ones. Sample heterogeneity and residues from pervious samples have a larger influence on the accuracy of the measurement when applying shorter tubes. Larger sample volumes ensure more stability. Exception: For measuring dark samples it might be necessary to use a shorter measuring tube due to the high absorption of light. Please consider that SCHMIDT+HAENSCH guarantees for the precision of Polarimeters its only if SCHMIDT+ HAENSCH measuring tubes are used. Flow-through tubes Flow-through tubes are recommended for testing a large number of samples of the same type. SCHMIDT+HAENSCH recommends two types of tubes: - for manual sample changing or - for automatic sample changing The tubes for manual sample changing work with funnel and riser on the basis of communicating tubes. The sample in the tube is totally displaced by the following sample. A volume of approx. 60 cm 3 is sufficient. The automatic sample changing in the tubes works using a by-pass or a pump with hose connections. A volume of approx. 60 cm 3 is sufficient, too. Glass sample tubes for single measurements Glass tube without bubble trap 5,5 10,5 02595 02596 Glass tubes with bubble trap Filling through narrow end and short turnover after sealing prevents influence of air bubbles on measurement. 50 8,0 10,5 16,5 02604 02600 02601 Glass tube with center filling cup The filling cup allows easy filling and emptying of the tube. Air bubbles escape through the filler opening when moved slightly. Temperature sensor Accessories (s. P. 4) 50 3,0 6,0,0 For medical applications: 95,04 190,09 5,5 11,0 02611 02607 02608 026 02613 Quartz glass flow-through sample tube, thermostatable 7,0 08866 Quartz glass micro tube, thermostatable 1,0 08962 Precision quartz glass flow cell for small sample volume With adapter for S+H Polarimeter 10 0,7 09521

Flow-through sample tubes (stainless steel) Flow-through tube with funnel and riser, tube for manual sample changing, not thermostatable 092 09213 Flow-through tube with funnel and riser, with 6 mm hose connection for water circulation 09216 092 Flow-through tube with funnel and riser, with integrated temperature sensor, thermostatable 03820 03830 Only for the new UniPol L-series, Polartronic M- and H-series and new SACCHAROMAT -models with plug connection inside of the sample compartment. Automatic temperature compensation. Temperature measuring of the sample, not of the sample room! Flow-through tube with hose connection, automatic sample changing 50 10 09628 09208 09209 Flow-through tube, thermostatable version with 6 mm hose connection for water circulation 09214 09215 Micro-flow-through sample tube with 4 mm hose connection, not thermostatable 10 1,5 02748 Stainless steel sample tube with center filling cup, thermostatable,0,0 02614 02619

Quartz control plates for calibration of polarimeter (Control of the instrument according to GLP) Quartz control plates are measuring standards, used as testing and adjusting kits for polarimeters. Thin quartz plates (0.4 to 1.6 mm thickness) are polished with highest precision vertically to the axis and plane parallelly. For reasons of mechanical stability, plates with a low angle of rotation (between -24 Z and +24 Z) are produced as double quartz plates (combination of a dextro- and a laevorotatory plate). For each SCHMIDT+HAENSCH quartz control plate a factory certificate is supplied, indicating the absolute angle of rotation in angular and Z for the wavelength 546, 587, 589 and 882 nm. The angle of rotation of the quartz plate is directly correlated to its thickness and will be indicated at a temperature of 20 C for the wavelength 589 nm. Since the angle of rotation is highly influenced by the wavelength while the sugar degrees are not, the following table shows the correlation between the different values of the certificate so that the calculation of the angle of rotation of a quartz plate is possible from the sugar degree indicated below for different wavelengths at 20 C. Wavelength in nm Conversion factor from angular to sugar Conversion factor from sugar to angular 546.23 2.46 0.41 589.44 2.89 0.35 882,6 6.76 0.15 The required (or needed) value must be specified in your order! Single quartz control plate Standard sugar degree: - 30 Z (±1 Z) Standard sugar degree: +25 Z (±1 Z) Standard sugar degree: +50 Z (±1 Z) Standard sugar degree: +75 Z (±1 Z) Standard sugar degree: +99 Z (±1 Z) Double quartz control plate Standard sugar degree: +15 Z (±1 Z) Standard sugar degree: +20 Z (±1 Z) Accessories for quartz control plates Temperature sensor for automatic temperature correction. Only to be used with new L-, M- and H-series and new Saccharomat models with plug! Replacement of the factory certificate (only for quartz plates in good shape and no changes are necessary) Offical certificate for quartz control plates can be supplied by the German Institut of Metrology (PTB) on their actual charges 00613 00616 00618 00619 00621 00614 00615 07277 Accessories for quartz glass tubes and flow-through tubes Cover glass for polarimeter tubes, diameter 15.5 mm Elastic insert for polarimeter tubes, diameter 15.5 mm Cover glass for polarimeter tubes, diameter 23.7 mm Elastic insert for polarimeter tubes, diameter 23.7 mm Cleaning brush for sample tubes Thermometer; 0 to 40 C; 0.1 C grating; for tubes with center filling cup Rubber stopper, with hole to insert thermometer Temperature sensor for automatic temperature correction for glass tubes with center filling cup (also available for old tubes), can be used with all new Unipol L-series, Polartronic M- and H-series and new SACCHAROMAT models 01811 01813 018 01814 01838 01816 08341 03720 Subject to modification without notice Änderungen vorbehalten 08/08 SCHMIDT+HAENSCH GmbH & Co. Waldstraße 80/81 D-13403 Berlin Germany Phone: +49 30 / 41 70 72-0 Fax: +49 30 / 41 70 72-99 e-mail: sales@schmidt-haensch.de www.schmidt-haensch.com Opto-electronic measuring device since 1864 ISO 9001:0

POLARIMETER TUBES Schmidt+Haensch announced: NEW Polarimeter Tubes temperature controlled by electronic Peltier System Highly accurate sample temperature adjustment without the need for an external water circulator! Features: Accurate temperature control without external water circulator Large temperature range can be controlled (18 C 40 ) Fast cooling of warm samples in a few minutes Tube: mm path length Single measurement Normal volume Made from stainless steel Controlled by separate electronic unit Automatic indication of tube length and thermal extension coefficient Can be used in all our digital polarimeters of Unipol L series T Cell calibration kit for temperature validation and calibration Opto-electronic measuring devices since 1864 / www.schmidt-haensch.com

The optical activity of the sample, measured in angular degree, is a physical property of the solved matter and depends on the temperature as well as the sample itself, the concentration, the tube lengths and the wavelengths of the used light. The influence of temperature changes is specific for each material. To be able to compare several measuring values, the reference temperature for polarimetric measurements is 20 C (or 25 C). For some substances the effects of temperature changes on the measured angle are well known. One example are sucrose solutions. Most polarimeters have implemented the so called sugar scale Z, which includes a factor to compensate the influence of the temperature. In case the instrument knows the sample temperature (by using temperature sensors), the polarimeter is able to calculate and indicate the concentration of the sucrose solution compensated to the reference temperature of 20 C. For all other matters the customer should measure at the reference temperature of 20 C or he must accept a lower precision of the measuring value. The most common way to cool or heat the sample is to connect the sample tube with an external water bath. In addition nowadays polarimeter tubes with integrated Peltierelements are available. Schmidt+Haensch s new developed T Cell is controlled by a separate electronic unit which has his own power supply. Temperatures are programmed and set by the electronic unit via 4 buttons on LCD screen. Technical Data: T Cell Consists of T Cell polarimeter tube and electronic unit T Cell polarimeter tube Automatic electronic heating and cooling of the sample Temperature range: 18 C 40 C Temperature precision: ± 0.1 C Temperature stability: ± 0.05 C Time for ΔT = 10 C: 10 min Tube length mm Sample volume approx. cm 3 Contact material (depending on the model) Stainless steel, float glass T Cell Electronic Unit Display Power supply Two lines, illuminated backround 240 V, 20 VA Opto-electronic measuring devices since 1864 / www.schmidt-haensch.com