PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme

Similar documents
Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

Paradise Pump Series Operator s Manual

Series. PressureGuard EASY AIR OWNER S MANUAL. PressureGuard EASY AIR XL. PressureGuard EASY AIR LR. PressureGuard EASY AIR

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

Med Aire Alternating Pressure Pump and Pad System

PressureGuard Custom Care Convertible LAL. Series

Alternating Pressure / Low Air Loss Mattress System

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Air Plus User Manual

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

RIK Fluid Overlay INSTRUCTIONS FOR USE

Instruction Manual for Configura Cushionair Portable Pump

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

Use this key to determine which sections of this Product Manual apply to your job.

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

UL COVERAGE IS FOR THE AIR SUPPLY ONLY

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

MA90 Series Mattresses. MA95 Series Mattresses

PressureGuard Custom Care Convertible Series

User manual STARLOCK. Careways International - Innovation Quality Performance

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

ComfortGel SE support surface Operations Manual

Turnout gear is comprised of boots, coat, pants, suspenders, hood, gloves, helmet, and SCBA Facepiece.

User Guide Antidecubitus systems EURO BASIC

USER MANUAL LTH-255A Hand Piece

Lateral Turning System. User Guide.

Joerns Healthcare. transforming wound management. User-Service Manual TriLine Support Surface. To avoid injury, read user s manual before using.

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

ALPHAXCELL. Active pressure relieving mattress overlay system for medium risk patients in all environments

MA60 Series. MA60 Alternating Pressure System. MA65 Alternating Pressure On-Demand Low Air Loss System. Owner s Operator and Maintenance Manual

SALISBURY ACTIVE OVERLAY SYSTEM

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

User Manual soft air wds

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

Operations/Maintenance Name of Manual

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

OPERATION MANUAL ASPEN MASSAGE TABLE OR MULTI-PURPOSE LIFT TABLE. (800) (760) Fax: (760)

better science. better care. Product Catalog

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Our Spa covers. About Spa Cover Vinyl

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Spray N Splash JUNGLE FUN POOL

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

User Manual. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Cobi Positioning Cushions

INDUSTRIAL - SOLVENT PARTS CLEANER

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Owner s Guide. ElevateSUP.com

MODEL NUMBER: P PORTABLE COMPRESSOR

Arise 1000EX Low Air Loss Therapy Mattress. Operations/Maintenance Manual. Model 2236

User-Service Manual Joerns Support Surface FlapCair. To avoid injury, read user s manual before using.

Pressure Ulcers ecourse

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE

PERFORM Operating Document

CART FOR CENTURION 1500+

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

Instructions for Use. OptiLife Nasal Lab Mask

AKRON CHILDS TILT TABLE

Instructions for Use (IFU) Electrical Leg- & Arm lift, model , ver. 2012

5110 N / 5110 W. Installation & Operation Manual Series Stretchers. Part Number: /13

NIMBUS range. with people in mind

User Manual DIRECTHEALTHCARESERVICES.CO.UK

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

Arterial Puncture Wrist. Instruction Manual

OWNER S MANUAL. Span America Medical Systems, Inc. Greenville, SC

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Inflatable Dock Slide Owner s Manual

Cascade Patient Transfer Lift System Safe Operation & Daily Maintenance Instructions

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

Use and Care Guide. PMU and PMU w/over the Patient. Swing Mount. Over the Patient. Side Delivery

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

MODEL NUMBER: P PORTABLE COMPRESSOR

12V AIR STATION ALL-IN-ONE

DOC PCB901 Rotating Half Rail Instructions REV 001

CLPNA Pressure Ulcers ecourse: Module 5.2 Quiz II page 1

SILENTAIRE TECHNOLOGY

User manual. ZX trolley.

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

User-Service Manual Joerns Healthcare Advanced Wound Care Integrated Bed System DolphinCare Fluid Immersion Simulation with UltraCare XT

OPERATORS MANUAL MODEL 365 BACK LAPPING MACHINE WARNING

USER S MANUAL. Get out of the

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

Transcription:

OWNER S MANUAL PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme Span America Medical Systems, Inc. Greenville, SC 29615 800-888-6752

TABLE OF CONTENTS DOCUMENT SYMBOLS...2 INTRODUCTION... 3 General Description Indications Modes of Operation FEATURES COMMON TO BOTH MODELS...6 DIRECTIONS FOR SET-UP...7 GENERAL DIRECTIONS...9 Bed Linens Bed Rails CPR Storage Warranty Use in Wound Care Air Filter Preventive Maintenance CLEANING and DISINFECTION...11 SPECIFICATIONS.. 12 ORDERING INFORMATION...13 1

Document Symbols This manual contains different typefaces and symbols to make the content easier to read and understand: Standard text used for regular information. Boldface text stresses a word or phrase. NOTE: - sets apart special information or important instruction clarification. The symbol below identifies a WARNING or CAUTION: - A WARNING identifies situations or actions that may have an effect on patient or user safety. Ignoring a warning could cause patient or user injury. - A CAUTION points out special procedures or precautions that persons must obey to avoid equipment damage. The symbol below identifies an ELECTRICAL SHOCK HAZARD WARNING: 2

INTRODUCTION To the PRESSUREGUARD APM 2 Alternating Pressure Mattresses DESCRIPTION: The system consists of a foam shell with a high-density foam topper serving as the support surface underneath the patient. The foam shell also includes contoured foam bolsters at the sides and ends of the mattress, providing added patient stability and positioning. The system also includes the unique Heel Slope feature, designed to further reduce pressure for the sensitive heel area. Within the foam shell is housed the inflation system, consisting of air cylinders which run lengthwise within the mattress. The air Control Unit connects to the mattress at the patient foot-end. INDICATIONS FOR USE: PressureGuard APM 2 models are powered, flotation therapy mattresses providing a pressure management surface for the prevention and treatment of pressure ulcers. The lateral rotation mode is indicated for use as a preventive tool against further complications associated with critically ill patients or immobility. MODES OF OPERATION: The PressureGuard APM 2 provides options of alternating pressure or basic lateral rotation in 10-minute cycles. WARNING - To reduce the risk of electrocution READ ALL INSTRUCTIONS BEFORE USING THIS UNIT. 1. Always unplug this unit immediately after using. 2. Do not operate near water. 3. Do not place or store product where it can fall or be pulled into a tub or sink. 4. Do not place in or drop into water or other liquid. 5. Do not reach for a product that has fallen into water. Unplug immediately. 6. Use this unit only for its intended use as described in the operating instructions. 7. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Span-America Medical Systems, Inc., for return of Control Unit for examination and repair. 8. Keep the cord away from heated surfaces. 9. Never drop or insert any object into any opening or hose. 10. Do not use outdoors. 3

To reduce the risk of burns, electrocution, fire or injury to persons: 1. Use this unit only for its intended use as described in the operating instructions. 2. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the unit to Span-America Medical Systems, Inc. for examination and repair. 3. Keep the cord away from heated surfaces. Discontinue use if power cord is damaged or worn. 4. Never drop or insert any object into any opening or hose. Keep away from sharp objects. 5. Do not use outdoors. 6. Possible explosion hazard if used in the immediate proximity of flammable gases (risk of explosion). 7. Use only original spare parts and consumables. 8. Keep power cord away from heated surfaces. 9. Plug this product into a correctly grounded outlet only. 10. Before cleaning, unplug unit from its power source. Failure to do so could result in personal injury or equipment damage. 11. Do not use harsh cleansers, solvents, or detergents. Do not expose the unit to excessive moisture. Equipment damage could occur. 4

c Cover f Air Cylinders d Foam Topper with Geo-Matt design e Safety Edge bolster g Toggle Switch h Control Unit 5

COMMON FEATURES All APM 2 Models The air-cylinder inflation system and the foam shell work in concert to maintain low interface pressures throughout the surface, making mattress effective for prevention and treatment of pressure ulcers. Cover [Illustration item ] The bacteriostatic top fabric is fire resistant, fluidproof, tear resistant, cleanable, and replaceable. The pleated design allows full integration with the mattress s Geo-Matt style shear-relieving surface while minimizing hammocking. Foam Topper: [Illustration item ] The patented Geo-Matt style foam topper is a high density, medical grade foam. The unique geometric design consists of over 800 individual cells, each of which acts individually to redistribute pressure, to reduce heat and moisture buildup on the skin, and to reduce shear to underlying tissues. This foam topper is 2" in height and includes the unique Heel Slope feature, designed to further reduce pressure for the sensitive heel area. Safety Edge Bolsters [Illustration item ] The patented Safety Edge consists of contoured foam bolsters around the sides and ends of the mattress for added patient stability in sitting and lying down. Air Cylinders: [Illustration item ] The inflation system consists of four urethane air cylinders in standard models that run head to foot underneath the body and the foam topper. These cylinders perform the alternating pressure therapy, and the lateral rotation therapy. Cylinders inflate and deflate in a fixed 10-minute cycle. The cycles and inflation levels are designed to provide and maintain low interface pressures throughout the mattress, and to redistribute peak interface pressure points during the alternating cycle. Toggle Switch [Illustration item ] The toggle switch changes modalities from alternating pressure to lateral rotation. The switch is located under a velcroed fabric flap on the side of the mattress at the foot end, as illustrated. Control Units: [Illustration item ] Model 5800 PressureGuard APM 2 Deluxe Control Unit 6

DIRECTIONS FOR SET-UP 1. Place the PressureGuard mattress on the bed frame with the air line connectors at the foot end of the bed. Hospital-grade models have a gray vinyl side that should be down on the bed frame, and a green fabric side that should be face up toward the patient. In-home models have a light blue cloth side that should be face down on the bed frame, and a dark blue fabric that should be face up toward the patient. Hospital-grade models In-home models (available for APM 2 only) 2. Hang the PressureGuard control unit on the end of the bed using the hangers, or place on a stable horizontal surface. Connect airlines to control unit, using end with one male and one female connector. (Figure A) Audible click indicates secure connection. 3. Connect the ends of the air lines with two male connectors to the mattress. Ensure that the air lines are not kinked or twisted. Push in securely until you hear a click. 4. Ensure that the Toggle switch is in the Alternating Pressure position. 5. Ensure On/Off switch is Off. Plug power cord into wall outlet. Figure A: Connecting air lines to control unit. Press On/Off switch ON. 6. Allow the mattress 20 minutes to inflate fully. The surface is ready for patient use when the Low Pressure indicator light turns off. 7. After preparing the patient surface, place the patient on the Figure B: Control Unit system. Initially set the Comfort Setting knob on the control panel to softest selection. (Figure B) Adjust as necessary for patient comfort. 8. Place the mattress toggle switch in Alternating Pressure or Lateral Rotation mode as desired. 9. When the Alarm On light is on, alarm will sound if Low Pressure indicator light comes on. Press Alarm switch to silence. Note: Will not alarm during first 45 minutes after plug-in. 7

If Low Pressure indicator light comes on after initial set-up, check all connections. If light is still on after 30 minutes, call for service. POWER LOSS: In case of loss of power, disconnect the air lines from the mattress BEFORE unplugging the Control Unit from the wall. This will seal the air in the mattress for days or weeks. See Note and Figure 1and Figure 2 below. PATIENT TRANSPORT: In case of loss of power, or while transporting a patient on the mattress, disconnect the air lines from the mattress BEFORE unplugging the Control Unit from the wall. This will seal the air in the mattress for days or weeks. NOTE: If the air lines are green, you can keep them connected to the mattress, but disconnect them from the Control Unit (Figure 1) and insert them into each other as indicated in Figure 2 below. This will seal the air in the mattress for days or weeks. Figure 1 Figure 2 HEAD-OF-BED ELEVATION: Lifting the head of the bed more than 30º puts the skin over the sacrum at high risk for breakdown due to a concentration of weight on this area of the body in this position. We advise limiting raising the head of the bed to no more than 30º, and limiting the amount of time spent in that position. Patient repositioning to change pressures on the body remains a basic need in patient care. TROUBLESHOOTING PATIENT COMPLAINTS: Occasionally a patient will complain of feeling as if they are sinking into a hole. 1) Sometimes this happens when the head of the bed is elevated and the mattress is in either lateral rotation or alternating pressure. This sensation is a combination of the deflation of the cylinders during their cycle and the increased weight of the patient on the sacrum and pelvis when the head of the bed is elevated. This demonstrates the need to minimize elevation of the head of the bed. To improve this situation decrease elevation of the head of the bed. 2) Often patients complain when they are supine or side-lying and are not used to the changing pressures within the air system. Reassure the resident that this is normal functioning, as the cylinders alternately inflate and deflate. The deflated tubes are not fully deflated. Some air is always maintained in them to prevent bottoming out. After reassurance, patients get used to the changing pressures. 8

GENERAL DIRECTIONS BED LINENS: Seven-inch deep fitted sheets are recommended. Multiple layering of linens or underpads beneath the patient should be avoided for the prevention and treatment of pressure ulcers. For Safety Supreme version, it may be easier to use flat sheets, knitted stretchfit sheets, or deep-pocket fitted sheets. CAUTION: Be careful not to puncture the mattress with needles or sharp instruments. This may result in loss of integrity of the cover or internal air system. Regularly inspect the mattress cover for cuts, rips, cracks or tears. Do not use the mattress if the cover is damaged. BED RAILS: Due to concerns over the possibility of patient entrapment, Span-America recognizes that the use of rails of any length is a matter currently addressed by various regulations from local, national and international government agencies, and by individual facility protocol. It is the responsibility of the facility to be in compliance with these laws, which typically require that decisions on the use of bed rails of any type are based on assessment of the physical and mental status of each patient individually. If bedrails are needed by the patient to prevent fall-related injury, as determined by this assessment, we recommend that the bedrails be locked in the up position at all times. CPR: The Standards for Life Support recommended by the American Heart Association for performing CPR recommend a hard level surface for performing CPR. This means moving the person to the floor if possible. For performing CPR: 1. Place a crashboard beneath the patient. 2. Select the Alternating Pressure mode. 3. Set the Comfort Setting knob to firmest setting. 4. Follow CPR procedures. STORAGE: Always store the surface flat on a clean, level surface. Avoid storage of other equipment on top of the mattress. WARRANTY: All models are unconditionally guaranteed against failure due to manufacturing defects under normal use for 18 months. USE IN WOUND CARE: Use of PressureGuard APM 2 models is only one element of care in the prevention and treatment of pressure ulcers. Frequent repositioning, proper care, routine skin assessment, wound treatment and proper nutrition are but a few of the elements required in the prevention and treatment of pressure ulcers. As there are many factors that may influence the development of a pressure ulcer for each individual, the ultimate responsibility in the prevention and treatment of pressure ulcers is with the health care professional. 9

AIR FILTER PREVENTIVE MAINTENANCE: The air filter for the Control Unit should be checked routinely for signs of dirt or contamination. The frequency for cleaning depends on the air quality. The air filter is accessible from the underside of the Control Unit - it is approximately two inches in diameter and covered by a clear plastic cover. As the filter is white, the need to clean is obvious. Simply remove the clear plastic cover, remove the filter, and hand wash using warm water and mild detergent. Rinse thoroughly and allow to air dry. Replace the filter and the clear plastic cover. 10

CLEANING and DISINFECTION All Models For the mattress, only the cover requires cleaning and maintenance. Disassembly of the support surface for maintenance of internal components of the Control Unit or mattress is not recommended. Cover can be wiped clean with neutral suds and lukewarm water. Rinse and dry. For hard to clean spots, use standard liquid household/vinyl cleaners with a soft bristle brush. CAUTION: DO NOT USE HARSH CLEANERS OR SOLVENTS. For long-term incontinent applications, clean and disinfect cover daily. A scented cleaner/disinfectant is recommended. Iodophor type disinfectants (Betadine for example) will stain the fabric. For disinfection, phenolic or quaternary type disinfectants are recommended. Disinfectants should be hospital grade (tuberculocidal). Follow manufacturer s instructions for use concentrations, contact times and rinsing. Contamination with blood on the fabric can be disinfected with a 1:10 dilution of household bleach (5.25% sodium hypochlorite) as recommended by the CDC. The use of bleach at improper dilutions may result in fabric discoloration and fluid pass-through. Where surveillance and epidemiology indicate ongoing transmission of C. difficile, an EPAregistered hypochlorite-based disinfectant is recommended. Follow the manufacturer s instructions for use concentrations, contact times and rinsing. Generic sources of hypochlorite (e.g. household chlorine bleach) may also be used. Prepare the disinfection solution fresh daily at a 1:10 dilution. Improper dilutions may result in ineffectiveness and higher than recommended concentrations will damage the fabric. Note: alcohol-based disinfectants are not effective against C. difficile and should not be used to disinfect environmental services. For further information relative to this organism and infection control in the healthcare setting, please refer to www.cdc.gov/ncidod/hip. Disinfect mattress covers following contamination with bodily fluids and between patients. Inspect the covers and zipper area for signs of damage, puncture, or wear that could result in fluid pass-through. If the cover is stained, soiled, or torn, inspect the internal components for signs of contamination. Allow cover fabrics to air dry (approximately 20 30 minutes) before use. WARNING: If contamination is evident, quarantine the mattress and remove from service following infection control procedures. 11

SPECIFICATIONS COVER: Bacteriostatic, flame resistant, fluid-proof, tear resistant FOAM: High-density open-cell polyurethane. Conforms to NFPA 101 small scale and Cal TB# 117. AIR CYLINDERS: Urethane and/or Fabric Coated PVC ELECTRICAL: All control units 120 V, 60 H. With respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1. With respect to electric shock, fire, mechanical and other specified hazards only in accordance with CAN/CSA C22.2 No. 601.1 Medical equipment certified for Canada. STANDARD SURFACE SIZES: 80 L X 35 W (all are 7 high) 84 L X 35 W 75 L X 35 W 80 L X 38 W - In-Home 75 L X 54 W - In-Home 80 L X 54 W - In-Home 80 L X 60 W - In-Home MATTRESS HEIGHT: WEIGHT LIMIT CYCLE TIME: PLACEMENT: WARRANTY: FLAMMABILITY: 7 for all models; Safety Supreme has 9 high side bolsters. 350 lbs. for standard models 10 minutes All mattresses can be placed directly on a hospital bed frame or standard bed frame or box spring. 18 months, not pro-rated, against manufacturing defects. All models comply with 2000 NFPA 101 (Life Safety Code), Cal. TB #129 and 16 CFR 1632 and 1633. 12

ORDERING INFORMATION Product Name Catalog Number Mattress Size PressureGuard APM 2 5875LR-29 75 L X 35 W X 7 H With Deluxe 5800 Control Unit 5880LR-29 80 L X 35 W X 7 H 5884LR-29 84 L X 35 W X 7 H PressureGuard APM 2 Safety Supreme SAF5875-29 75 L X 35 W X 7 H center, 9 H side Full safety features, with Deluxe 5800 Control Unit SAF5880-29 80 L X 35 W X 7 H center, 9 H side SAF5884-29 84 L X 35 W X 7 H center, 9 H side In-Home Style Pressure Guard APM 2 Dual King AP28038 80 L X 38 W X 7 H Therapy on right side (-RT) or in center (-CTR) Full AP27554-RT or AP27554-CTR 75 L X 54 W X 7 H Full Long AP28054-RT or AP28054-CTR 80 L X 54 W X 7 H Queen AP28060-RT or AP28060-CTR 80 L X 60 W X 7 H Replacement Air Systems For APM, 80 and 84 model 5780 For APM, 75 model 5775 For APM 2 and Safety Supreme 80 and 84 models For APM 2 and Safety Supreme 75 model 5880 5875 5800 control unit only (Deluxe) 5800 Replacement Airlines only APM 2 P02803 Call Customer Service (800-888-6752) for information on coverlets, transport bags, and other available accessories. 13

THIS PRODUCT IS PROTECTED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS: D502,350 6,782,574 6,256,822 6,256,819 6,223,369 6,036,271 5,797,155 5,699,570 5,652,985 5,649,331 5,580,504 5,412,821 D355,322 5,252,278 5,025,519 4,862,538 Additional patents pending. SPAN-AMERICA MEDICAL SYSTEMS, INC. Greenville, SC 29615 800/888-6752 14