PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084

Similar documents
SySTEm Flow chart ANESTHESIA patient connection

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia

System Flow Chart. ventilation patient connection

General Anaethesia Airway

Anesthesia Breathing Circuit

LISTADO DE CIRCUITOS DE PACIENTE

Product guide. World Class Performance. Heat & moisture exchangers and bacterial/viral filters for patient comfort and infection prevention

Heated Wire - Neonate Ø10mm Infant Ø12mm

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Anesthesia Products & Circuits

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

Great products available through ROI!

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Solutions for Oxygen Therapy & Airway Management

Intersurgical Product List

Anesthesia. Midmark Animal Health Products

Table of contents. Breathing Circuit. Neonatal Care. Anesthesia Circuit. Accessories

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

Mechanical Ventilation

Technical Data and Specifications

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology

Standard Operating Procedure

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE.

Sterile product catalogue

O-Two Self-Study Guide. Equinox Relieve

A. APPLICATIONS 1. WARNING TO USER

CATALOGUE. Adult and Infant Respiratory Care Catalogue

AUTOVENT 4000 VENTILATOR

Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES. Copyright ReadMed Company Ltd

Puritan Bennett 840 Universal Ventilator

Hamilton accessories CONTENT

Breathing Circuits. Product training

Operation and Maintenance of the EPV200 Portable Ventilator

Recommendations on Checking Anaesthesia Delivery Systems

INTRODUCTION. EN ISO 13485: AC:2012, EN ISO 9001:2008

Assessment & Placement GUIDE

respiratory care aerosol therapy

AirLife. International respiratory product catalogue

VENTILATORS PURPOSE OBJECTIVES

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Draeger Fabius GS Pre-Use Check

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

(Delivery System) Pocket Guide Series 3 software

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

INTENSIVE CARE VENTILATORS

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Product Catalog

(Delivery System) Pocket Guide. Series 3 software

Making Life Easier Easypump II

Operational Efficiencies

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Anesthesiology Research and Scholarship. Follow this and additional works at:

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

Index. Filtration and cross contamination 3. Mechanical filters Sterivent range 8 Sterivent range configurations 9

Understanding Tracheostomy Care

Respiratory. Products by Galemed

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation

Astral in AirView: Improving patient care through connectivity. ResMed.com

Recommendations - USA

Corporate Overview and Product Summary

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Automatic Transport Ventilator

GE Healthcare. Avance Carestation. Upgrade promotions guide

MACS Mask CPAP System

Unit 15 Manual Resuscitators

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Patient Comfort. Oxygen Therapy Compliance Uninterrupted oxygen therapy aids compliance of prescribed oxygen therapy.

Accessory Catalogues. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Instructions/Procedure for Use of the Speaking Valve

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic


USER INSTRUCTIONS. S I L - C O N N - K I T S m a l l e r h o s e t o F l o w m e t e r L a r g e r h o s e t o V a c u u m C o n t r o l D e v i c e

Astral in AirView: Improving patient care through connectivity. ResMed.com

McHENRY WESTERN LAKE COUNTY EMS SYSTEM FALL 2014 CONTINUING EDUCATION MANDATORY FOR ALL PRIMARY AND PROBATIONARY ALS SYSTEM PROVIDERS.

Understanding Tracheostomy Care for your Child

Your patients, our primary focus. Siesta i Whispa anesthesia machine

DPA 02 TM Diamedica Portable Anaesthesia System INSTRUCTIONS AND USER GUIDE

My CoughAssist. A patient guide to CoughAssist T70. Please visit

Tracheostomy and Ventilator Education Program Module 11: Emergency Preparedness

Straight & Straight-Tee

Flow meter. bellow vaporizer. APL valve. Scavenging system

QED-100 Clinical Brief

Respiratory Care. and Aerosol Therapy

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

SyStem Flow Chart anesthesia SyStem Flow-i

LarySeal - Laryngeal Mask Airways

RESPIRATORY CARE POLICY AND PROCEDURE MANUAL. a) Persistent hypoxemia despite improved ventilatory pattern and elevated Fl02

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

Emergency Transport and Ventilation

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

DIAGNOSTIC CARDIOLOGY

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation

GE Healthcare. Aestiva/5. More than superior ventilation

Hospital and Transport for Controlled Breathing

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Intensa GO Alternate Care Ventilator

1 of 9 10/20/2010 4:45 PM

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Transcription:

PRODUCT CATALOG Every Breath Matters ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck 4296 Cowan Road Tucker, GA 30084 Order Number: 800.950.ARC1 (2721) Fax: 404.373.8385 General Information Voice Mail: 800.950.2720 Ext 272 E-Mail: arcinfo@arcmedical.com Web: www.arcmedical.com

Table of Contents CATEGORY PAGE Respiratory Products 3-6 Anesthesia Products 7-9 Pneumonia Check 10 Notes 11 Every Breath Matters TO ORDER CALL: 800.950.ARC1 Page 2

Products for Respiratory Care ThermoFlo Filter Maintains sputum consistency and provides therapeutic humidification in a filtered device. Zero ET tube occlusions reported. #6000 ThermoFlo Filter with HCH 40/case #6001 ThermoFlo Filter with HCH EcoPak 100/case #6001V ThermoFlo Filter with HCH VolumePak 200/case #6020 ThermoFlo Filter with ETCO 2 GS Port 40/case Specifications at high V E : Moisture Returned H 2 O/L: 33 mg @ 10L V E & 31mg @ 20L V E Resistance: @ 30 LPM - 1.2cm Dead Space: 75 ml Weight: 33 grams Housing: Clear Tidal Volume Range: 250ml - 1500 ml Bacterial/Viral Efficiency: 99.99%+ TB Filtration Efficiency: 99.99%+ ThermoFlo Filter Special The S Version provides a collection chamber to help guard against increasing resistance due to secretions. Zero ET tube occlusions reported. #6000S ThermoFlo Special 40/case #6001S ThermoFlo Special EcoPak 100/case #6000SL ThermoFlo Special with luer port 40/case #6000SV ThermoFlo Special VolumePak 200/case Specifications at high V E : Moisture Returned H 2 O/L: 33mg @ 10L V E & 31mg @ 20L V E Resistance: @ 30 LPM - 1.2cm Dead Space: 75 ml Weight: 33 grams Housing: Clear Tidal Volume Range: 250ml - 1500ml Bacterial/Viral Efficiency: 99.99%+ TB Filtration Efficiency: 99.99%+ ThermoFlo 1 Filter & HCH The small size and low profile are excellent for pediatric, adult, and anesthesia patients. #6100 ThermoFlo1 Filter HCH 50/case #6101 ThermoFlo1 Filter HCH EcoPk 100/case #6120 ThermoFlo1 Filter HCH with ETCO 2 50/case #6121 ThermoFlo1 Filter HCH with ETCO 2 100/case Specifications at high V E : Moisture Returned H 2 O/L: 30.2mg @ 10L V E Resistance: @ 30 LPM - 1.2cm Dead Space: 30 ml Weight: 14 grams Housing: Clear Tidal Volume Range: 100 ml - 1200ml Bacterial/Viral Efficiency: 99.99%+ TB Filtration Efficiency: 99.99%+ TO ORDER CALL: 800.950.ARC1 (2721) Page 3

Products for Respiratory Care ThermoFlo MIDI HCH with Filter The MIDI version provides therapeutic humidification in a medium sized device. Also available in a special version with a collection chamber. #6310 ThermoFlo MIDI with ETCO 2 port 40/case #6310E ThermoFlo MIDI with ETCO 2 port 100/case Specifications at high V E : Moisture Returned: 32mg @ 20LV E Resistance: @ 30 LPM - 1.5cm Dead Space: 47ml Weight: 33 grams Housing: Clear Tidal Volume Range: 100ml - 1200ml Bacterial/Viral Efficiency: 99.99%+ TB Filtration Efficiency: 99.99%+ ThermoFlo HCH (No Filter) Therapeutic humidification in an economically priced HCH. Useful when a filter is not needed. #6070 ThermoFlo HCH 40/case #6071 ThermoFlo HCH EcoPak 100/case #6072 ThermoFlo HCH with ETCO 2 Port 40/case Specifications at high V E : Moisture Returned: H 2 O/L: 33mg @ 10L V E Resistance: @ 30 LPM - 0.4 cm Dead Space: 75 ml Weight: 32 grams Housing: Clear Tidal Volume Range: 250ml - 1500ml ThermoFlo 1 HCH (No Filter) The small size and low profile are excellent for pediatric and adult patients. Economically priced, and useful when a filter is not needed. #6060 ThermoFlo1 50/case #6061 ThermoFlo1 100/case #6160 ThermoFlo1 with ETCO 2 Port 50/case #6161 ThermoFlo1 with ETCO 2 Port 100/case Specifications at high V E : Moisture Returned H 2 O/L: 30.2mg @ 10L V E & 31mg @ 20L V E Resistance: @ 30 LPM - 0.7cm Dead Space: 30ml Weight: 14 grams Housing: Clear Tidal Volume Range: 100ml - 1200ml TO ORDER CALL: 800.950.ARC1 (2721) Page 4

Products for Respiratory Care ThermoFlo Neo HCH Transport moisture for patients who need it the most. Unexcelled low resistance to flow, critical in the care of special care babies. Non-absorbing HCH material reduces resistance problems. #6215 ThermoFlo Neo 100/case #6220 ThermoFlo Neo with ETCO 2 Port 100/case Specifications: Moisture @ V T 20ml = 32.5mg H 2 O/L air @/V T 25ml = 31.0 H 2 O/L air Resistance @ 7.5 L/min = 0.35cm H 2 O @ 15L/min 0.95cm H 2 O Dead Space: 2.5ml Weight: 3 grams Housing: Clear Tidal Volume Range: 5ml - 50ml ThermoFlo Trach HCH Available in either a basic trach or CRV (cough relief valve) trach. The CRV may be used for suctioning without removing the device, and features an optional integrated O 2 adapter for supplemental O 2 delivery. The HCH material is non-absorbing, helping to eliminate resistance. These are designed for spontaneously breathing patients through a tracheotomy tube. ThermoFlo Trach Basic: #6240 30/box #6240E 240 units (packed 8 bags of 30 each) ThermoFlo Trach Basic Oxygen Adapter: #6258 25/box ThermoFlo Trach CRV: #6241 With O 2 port 30/box #6241E With O 2 port 240/box (packed 8 bags of 30 each) #6242 Without O 2 port 30/box Specifications: Humidity V T 500ml: 26mg H 2 O / L air Resistance: @ 0.7 cm H 2 O @30 LPM Dead Space: 12ml TO ORDER CALL: 800.950.ARC1 (2721) Page 5

Products for Respiratory Care FilterFlo TB/Bacterial/Viral Filter Exclusive sure-fit system with no failure points. No glue or ultrasonic welding. Friction fit assures proper placement of media in housing, and protects against blow-by. #7010E FilterFlo Filter 100/case Specifications at high VE: Resistance: @ 30 LPM - 1.2cm Dead Space: 75 ml Weight: 33 grams Housing: Clear Tidal Volume Range: 250ml - 1500ml Bacterial/Viral Efficiency: 99.99%+ TB Efficiency 99.99%+ Taper Drape Flex Tube Order #5010T 100/case NOTE: To add a Taper Flex tube packaged with ThermoFlo, add the letter T to the order number. Example: 6000T ThermoFlo Special Diagram Page 6

Products for Anesthesia circuitguard HCH & Filter Protects patients and anesthesia equipment from contamination. The three main components of circuitguard are manufactured as one unit, using our exclusive sure-fit system. No glue or welding is needed, eliminating possible fail points found on other products. This particular model has an HCH and filter. #6126 circuitguard Straight Filter, HCH, ETCO 2 Port & Elbow 100/case Specifications: Humidity Returned mg H 2 O/L: 30.2mg @ 10L V E Resistance: @ 30 LPM - 1.2cm Dead Space: 30ml Weight: 14 grams Housing: Clear Tidal Volume Range: 100ml - 1200ml Bacterial/Viral Efficiency: 99.99%+ TB Efficiency 99.99%+ circuitguard Angle HCH & Filter Protects patients and anesthesia equipment from contamination. The three main components of circuitguard are manufactured as one unit using our exclusive sure-fit system. No glue or welding is needed, eliminating possible fail points found on other products. Device replaces need for an elbow. #6131 circuitguard 90 0 Right Angle Filter, HCH & ETCO 2 Port 100/case Specifications: Humidity Returned mg H 2 O/L: 30.2mg @ 10L V E Resistance: @ 30 LPM - 1.2cm Dead Space: 30ml Weight: 14 grams Housing: Clear Tidal Volume Range: 100ml - 1200ml Bacterial/Viral Efficiency: 99.99%+ TB Efficiency 99.99%+ TO ORDER CALL: 800.950.ARC1 (2721) Page 7

Products for Anesthesia circuitguard Filter Only Protects patients and anesthesia equipment from contamination. The three main components of circuitguard are manufactured as one unit using our exclusive sure-fit system. No glue or welding is needed, eliminating possible failure points. #7056 circuitguard Straight Filter Only, ETCO 2 Port & Elbow 100/case Specifications: Resistance: @ 30 LPM - 0.8cm Dead Space: 30ml Weight: 13 grams Housing: Clear Tidal Volume Range: 100ml - 1200ml Bacterial/Viral Efficiency: 99.9%+ TB Efficiency 99.9%+ Soft Air Cushion Face Masks with Inflation Valve May be packaged with circuitguard for your convenience. #5001 = Size 1 #5002 = Size 2 #5003 = Size 3 All are 50 /case #5004 = Size 4 #5005 = Size 5 NOTE: To add a mask to circuitguard, add the letter M and the size of mask 5. Example: 6126M5 TO ORDER CALL: 800.950.ARC1 (2721) Page 8

Products for Anesthesia Anesthesia Circuits Our anesthesia circuits are available in your choice of expandable or corrugated tubes. These circuits have no ports, no elbow and no filter. They are packaged with the wye piece, attached tubes with cuff adapters, and latex free re-breathing bag. Expandable Circuits X40LF3 30 case 40" flex, 3L latex free X72LF3 30 case 72" flex, 3L latex free X96LF3 30 case 96"flex, 3L latex free Corrugated Circuits D40LF3 30 case 40" hose, 3L latex free D60LF3 30 case 60" hose, 3L latex free D72LF3 30 case 72" hose, 3L latex free TO ORDER CALL: 800.950.ARC1 (2721) Page 9

PneumoniaCheck PneumoniaCheck is a specimen transport and storage container designed to collect uncontaminated lung samples, noninvasively. Patients simply cough into the device. It uses fluid mechanics to separate upper and lower airway aerosols to collect uncontaminated lung specimens. PneumoniaCheck is designed, and tested for PCR analysis, which can provide next day results. Uncontaminated identification of lung specimens is critical in effectively treating lower respiratory infections such as pneumonia. This identification may lead to decreased antibiotic resistance, hospital length of stays, and overall healthcare costs. Order Information PC-003D PneumoniaCheck Kit (isolation bag included) 10 Per Case PC-003 PneumoniaCheck Kit (isolation bag included) 25 Per Case PC-003E PneumoniaCheck Kit (isolation bag included) 50 Per Case PC-003V PneumoniaCheck Kit (isolation bag included) 100 Per Case TO ORDER CALL: 800.950.ARC1 (2721) Page 10

Notes Page 11

To Order Call: 800.950.ARC1 (2721) ARC Medical, Inc. 4296 Cowan Road Tucker, GA 30084 General Info Voice Mail: 800.950.2720 Ext 272 Order: 800.950.ARC1 (2721) Fax: 404.373.8385 E-Mail: arcinfo@arcmedical.com Rev. 5/2015 www.arcmedical.com