WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Similar documents
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

HI 2314 HI 2315 HI 23151

Techcon Systems TS1254 Pressure Pot

The Univentor 1250 Anaesthesia Unit

EC214 EC215 - EC215R Bench Conductivity Meters

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

Digital Melting Point Apparatus

Operating manual Analogue Brix Refractometer

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

BGA244 Binary Gas Analyzer

ANALOG ULTRASOUND WATTMETER USP-30

NovelBright LED Illuminator

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Techcon Systems TS1258 Pressure Pot

Hygienic Bubble Trap Installation and Operations Manual

GI Series Diaphragm Pressure Gauge Guard

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

Aerobic Respiration. Evaluation copy

CSA Sample Draw Aspirator Adapter Operator s Manual

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Operating manual Analogue refractometer

THE UNIVENTOR 400 ANAESTHESIA UNIT


Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Underwater Housing for Canon G7X Mark II

Fiber Optic Cable Installation 3 in 1 SLIDE, BLOW, LUBRICATE

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

MODEL NUMBER: AS18-2 USER GUIDE

User s Guide. VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System. For Models: Rev L (11/10/15)

BS ml Bottle Sampling Unit

Instruction Manual Updated 7/26/2011 Ver. 2.2

Powers Controls D Day-Night Thermostats

Multi-Probe Sampling System User Guide & Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

OPERATORS MANUAL MODEL 365 BACK LAPPING MACHINE WARNING

Model No Product Name Handpiece Only Complete System

User Instruction Manual

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

Safety instructions and operating manual

Code AWC20HP Air Compressor

VECTA DELUXE SENSORY DISTRACTION STATION INSTRUCTION MANUAL

Sample Concentrator SBH CONC/1 Instructions for use

Instructions for use Compressed air injector with water trap

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

P-5215 Differential Pressure Transmitter

INSTRUCTION MANUAL GAS TRAK

ROLLATOR (R6 and R8) OWNER S HANDBOOK

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

MAYHEM MAYHEM OWNERS MANUAL. Paintball Guns International. Manufactured by

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

! Warning, refer to accompanying documents.

P3800 Series. Users Manual. High Pressure Hydraulic Deadweight Tester

1 DRIVE INDUSTRIAL IMPACT WRENCH

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

LIGHTWEIGHT TRIWALKER OWNER S HANDBOOK

Instruction Manual Contact Pressure Vacuum Gauge

contents introduction

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

with O 2 Controller Instruction Manual

1020 Industrial Drive, Orlinda, TN fax

Oxygen Sensor with Electrode

Oxygen Concentrator Instruction

FLAPPER NOZZLE SYSTEM

RO LLATO R (R6 and R8) O W NER S HANDBO O K

User s Guide. CO2 & O2 Controller for miniature incubators

K-SYSTEMS Instruction Manual. CO ² Bench Top Incubator G85

CPR MEDICAL DEVICES INC. OPERATING MANUAL

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

G96 Series BASOTROL Dual Operator Valve

ATS430 turbidity sensor Retractable insertion assembly

RK LEL Sample Draw Aspirator Adapter Operator s Manual

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Budget Range Operators Handbook

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

OXYGEN MICROOPTODE - OPTO SERIES USER MANUAL

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Electro-Pneumatic Converter YT-940 SERIES

Pressure relief valve

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Transcription:

WXG-4 Manual Polarimeter Instruction Manual BANTE INSTRUMENTS CO., LTD

WXG-4 Manual Polarimeter 1 Introduction Thank you for selecting the Bante Instrument s WXG-4 manual polarimeter. This manual provides a step-by-step guide to help you operate the instrument, please carefully read the following instructions before use. Unpacking Before unpacking, ensure that the current work environment meet following conditions. Ambient temperature is greater than 0 o C and less than 40 o C. No potential electromagnetic and ambient light interference. The following list describes the standard accessories of the polarimeter. After the unpacking, please check all accessories are complete. If any are damaged or missing, please contact nearest distributor. Test tube 100mm Test tube 200mm Sealing rings Prior to Use Before plugging the plug into the power outlet, ensure that local mains power voltage matchs the polarimeter requirements. 1.1 Close the lid of polarimeter. Press the power switch to the ON position, the sodium lamp will gradually light up. 1.2 Wait for the light source to stabilize, rotate the focus knob until the visual field became legible. 1.3 Rotate the vernier knob makes the vernier scale aim at zero position. Focus knob Vernier knob

WXG-4 Manual Polarimeter 2 Recording the Reference Point 2.1 Place an empty test tube into the sample chamber. 2.2 Rotate vernier knob until the visual field appears uniform brightness. Record the measured value. Filling the Sample Solution 3.1 Take out the test tube from sample chamber. Unscrew the cap, remove the sealing ring and glass disc. 3.2 Rinse the test tube thoroughly with distilled water. 3.3 Pour sample solution into the test tube, then screw on the test tube cap. Wipe away the drops of water on glass disc. 3.4 If necessary, collect all air bubbles into the bubble trap. Bubble Trap Measurement 4.1 Open the lid of polarimeter, place the test tube into the sample chamber. Note, the bubble trap is upward. 4.2 Close the lid, clockwise or anticlockwise rotate vernier knob until the visual field appears uniform brightness. Record the measured value. 4.4 Repeat the above measurements 2 times and calculate the average of measured values. Calculation If the measured values are positive angle (Dextrorotatory substance), minus the value of the reference point shall be the actual measured value of the substance. If the measured values are negative angle (Levorotatory substance), minus the 180 o shall be the actual value of the substance.

WXG-4 Manual Polarimeter 3 Determination of the Concentration If you need to determine the purity, concentration or proportion of the sample, please use the formula below. α=[α]lc α... Optical Rotation [α]... Specific Rotation L... Tube length (dm) C... Concentration (g/l) Replacing the Sodium Lamp Before replacing the sodium lamp, be sure to disconnect the power plug from the wall outlet. 5.1 Wait for the sodium lamp to cool down, remove the lamp cover of polarimeter. 5.3 Pull the sodium lamp from the socket. 5.3 Insert a new lamp into the socket. 5.4 Replace the lamp cover again in such a way that the window point in the direction of the polarizer. Specifications Model Measuring Range Scale Value Vernier Magnifier Light Source Test Tube Length Power Requirements Dimensions Weight WXG-4-180 o ~180 o 1 o 0.05 o 3X Sodium Lamp, 589.44nm 50/100/200mm 220V/50Hz 500(L) 135(W) 330(H)mm 5kg

Hazardous Substance Statement Bante Instruments is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our product in the coming years. We welcome our customer suggestions on how to speed up these efforts. Warranty The warranty period for polarimeter is two years from the date of shipment. Above warranty does not cover light source. Out of warranty products will be repaired on a charged basis. The warranty on your polarimeter shall not apply to defects resulting from: Improper or inadequate maintenance by customer. Unauthorized modification or misuse. Operation outside of the environment specifications of the products. For more information, please contact the nearest authorized distributor. BANTE INSTRUMENTS CO., LTD E-mail: banteinstruments@yahoo.com Phone: +8621-6404-1598 Website: www.bante-china.com The information in this document is subject to change without notice. Copyright Bante Instruments, 2013. All rights reserved.