Designing a Pond Loop using. Alan Watts, CGD, IAI AWEB Supply Baton Rouge, LA

Similar documents
The Hoffman Specialty Series 2000 consists of main

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Brazed Heat Exchangers

ENGINEERING DATA. Engineering Data

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

FMU4X, FMC4X FMU4P, FMC4P

Brazed Heat Exchangers - Edition 2. Click Anywhere to enter

Pump On Demand. Skimmer System

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

iphone Application Slurry Pump System Calculator Instructions

Baffles and Traps Cryotrap

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

TAZGO DIVISION. Available Services: Shearing, Plate Burning, Saw Cutting, Drilling

GAS SUPPLY DESIGN GUIDE

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Eclipse Extern-A-Therm Recuperators

Air Eliminators and Combination Air Eliminators Strainers

Gerald D. Anderson. Education Technical Specialist

Lesson 27: Real-World Volume Problems

Coils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955

Expansion Tank Design (Chilled Water)

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Evaporator (DX) Freon Applications 1 12 Tons MHF

Appalachian Basin Gas Well. Marietta College, Marietta, Ohio June 7-8, Development. Robert McKee, P.E. Design Engineer Multi Products Company

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

This loop is filled with an antifreeze solution such

Septic Tank Buoyancy Control 101. David Lentz, P.E.

HOT SERIES (High Output Temperature) Geothermal Water to Water Heat Pump R-134A Refrigerant 2 Ton to 20 Ton Single Speed

Gas-Lift Test Facility for High- Pressure and High-Temperature Gas Flow Testing

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Geotech 1.66 Auto-Reclaimer Installation and Operation

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

FloWash. Industrial Filter Cart

ANALOG ULTRASOUND WATTMETER USP-30

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

TECHNICAL ACCESSORIES

1 Exam Prep State Pool Contractor Feedback Questions and Answers

Application Worksheet

Separation of Acetone-Water with Aspen HYSYS V8.0

Shell & Tube. JATCO Inc. Operating Manual

API Piping Plan 62: A Reliable Quench System

A Basic Approach to the Installation of Small Movement Expansion Joints. Peter Weykamp, P.E.

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

MILE POINT TRAINING WALL JACKSONVILLE, FL. Geotextile Tube Installation

Troubleshooting Guide. Pg. 1

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Irrigation System Winterization and Pressurization Procedures

SIZING AND CAPACITIES OF GAS PIPING

Gas Lift Valve Testing

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

SHOP WELDED TANKS STANDARD CONNECTIONS

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

Dewatering Landfill Gas Wells to Maximize LFG Collection

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Geotech 1.66 Auto-Reclaimer

Model Series 62 Constant Differential Relay

Recirculating Coolers

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

TANKS 4.0.9d Emissions Report - Detail Format Tank Indentification and Physical Characteristics

Flow Sensors & Hydrometers Specification Sheet

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

The density of a substance is the same for all samples of that substance.

CCT-7320/ROC-2313 Reverse Osmosis Controller

829S1 Series Flexflo Pilot

Pressure is defined as force per unit area. Any fluid can exert a force

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

MODEL 1329 Tank Gauge

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

NHR Powder Feed Hopper

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

North American Orifice Metering System

Natural Gas to L.P. Gas Conversion Kit

Catalina 36 Onyenma. Number:

Winter Culture of Caged Rainbow Trout in the South.

GAS SUPPLY APPLICATION GUIDE

Instruction Manual VCG-6

SIZING AND CAPACITIES OF GAS PIPING

Office Use Only Fee Paid

Physics 7b Midterm Exam #1 Fall Name: Disc. Section SID

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

Geotech 3.5 Auto-Reclaimer

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

IRC 2011 All Rights Reserved

Körting Liquid Jet Vacuum Ejectors

My Website:

PE 2708 CTS & IPS GAS PIPE

Fisher L2sj Low Emission Liquid Level Controller

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Transcription:

Designing a Pond Loop using Alan Watts, CGD, IAI AWEB Supply Baton Rouge, LA

The POWER of WATER ¾ of the Earth Surface is covered by WATER

Some See A Pond... We See a Fuel Free, Emission Free, Power Plant created through demand reduction when used in conjunction with geo-exchange heat pumps

Ability of Water to Handle Energy Example: 1 acre pond, 10 deep average 208 x 208 = 43,264 ft². 43,264 x 10 = 432,640 cubic feet 432,640 x 7.5 gal. cubic feet = 3,244,800 gal. 3,236,372 x 8.34 = 27,061,632 lbs... 27,061,632 lbs... or Btu s 1 Btu raises 1 lb. water 1 degree in 1 hour

Example- Small Pond Midwest A 10 ton (150,000 Btu/hr) heat pump system connected to a pond loop SLIM JIM Geo Lake Plate exchanger. Question: What effect does this system have on the temperature of the pond?

Small Pond Midwest Answer: Remember it would require approximately 27,000,000 Btu s to raise the temperature of the pond 1 Deg. F. Now, lets assume the impossible, no wind or evaporation to dissipate heat, no spring to replenish the pond water, and one 10 ton unit is running at full speed for 10 hours in cooling adding 150,000 Btu/hr into the pond. That would be a total of 150,000* 10 = 1,500,000 Btu s.

Small Pond Midwest This could change the pond temp 0.056 F per day. This is insignificant when you consider a steady 5 MPH wind blowing for 3 days can lower the pond temperature by as much as 5 Deg F.

Pond Temperature Change Calculator AWEB SUPPLY 7350 Tom Drive, Baton Rouge, LA 70806 Phone: 225-928-2630 Fax: 225-928-2087 email: info@awebgeo.com www.awebgeo.com 9/17/2010 HR Pond/Lake Calculations Project: Example Location: Midwest Heat of Rejection (HR): 150,000 Btu/Hr 10 Tons (HR) 1 Ton (HR): 15,000 Btu/Hr Length: 208 ft Width: 208 ft Surface Area:.99 Acre Surface Area: 43,264 sq. ft. Cu. Ft of Water: 432,640 cu. ft. Gal. of Water: 3,236,372 Gal. Lbs of Water: 26,991,344 Lbs Full Speed Run Time in 24 hours: 10 Hr Temp change per hour:.0056 F Temp change per day:.0556 F Btu's Required to Raise the Water Temp 1 F in 1 day: 2,699,134 Btu/Hr Ton(s) Required to Raise the Water Temp 1 F in 1 day: 180 Tons (HR) Pond Dimensions AVG Depth: 10 ft Temp. F : Water influx: Gal/Day Lbs Influx Water Temp: These basic calculation are done without taking into account for the gains or losses from incoming solar radiation, net advected energy, the energy in evaporation and condensation, the conduction of sensible heat from the water to the atmosphere, or vice versa, etc YELLOW = YELLOW CELL IS USER INPUT Version GREEN = GREEN FIELD IS CALCULATED 20100917

What is a Slim Jim Geo Lake Plate It is a simple, labor-friendly alternative to polyethylene pipe (lake loops) for fluid to fluid heat transfer in any water cooled refrigeration or heat pump equipment in (ponds/lakes/rivers/oceans). Easy to install (labor friendly) Easy to flush No limit to job size - single to multiple units

Family of Slim Jim & Geo Lake Plates

Size Does Matter By grouping like Slim Jim Geo Lake Plates in parallel they can accommodate almost any load 200 Ton Preassembled Bank 8 Ton Preassembled Bank 5 Ton Single Plate

Just Add Water (3) 8SJ040TCAMT3F3 40 Ton Preassemblies Banks

Project Information Sheet

HVAC Project 1 Equipment Type Equipment: WaterFurnace Envision TM NXW540 Source Water Temperatures: Summer: 81 F (Warmest at installation depth) Winter: 39 F (Coldest at installation depth)

Temperature Pond Depth vs. Temperature Copyright 1997, American Society Of Heating, Air-conditioning and Refrigeration Engineers Inc., www.ashrae.org.

The Summer condition is circled in RED Capacity Data sheet WaterFurnace Envision NXW540

Capacity Data sheet WaterFurnace Envision NXW540 The Winter condition is circled in BLUE We need to extrapolate the data to find a EST = 35 F EST = 30 F with a HE of 314.7 MBTUH EST = 50 F with a HE of 420.3 MBTUH The EST spread from 30 to 50 is 20 (420.3-314.7) = 105.6 105.6 20 = 5.28 5 5.28 = 26.4 314.7 + 26.4 = 341.1 EST = 35 F with a HE of 341.1 MBTUH

HVAC Project 1 Project Information Sheet Us the Envision NXW540 data sheets and the pond data to complete the Project Information Sheet

HVAC Project 1 Sizing Using the Slim Jim Geo Lake Plate design selection software, the Summer & Winter data is entered. The size and configuration of the Slim Jim Geo Lake Plate required for this project is displayed. Water = W Brine = B Summer Cooling Condition Cooling HR / Calculate Equipment LWT EWT F LWT F HR (kbtu) GPM/T Winter Heating Condition Heating HE / Calculate Equipment LWT EWT F LWT F 500 100.00604 0 29.997 0 Pond/Lake Temp (C1) F (Enter the Warmest temperature) Pond/Lake Temp (H1) F (Enter the Coldest temperature) Water = W Brine = B HE (kbtu) GPM/T Equipment EWT (H1) Equipment LWT (H2) 0.0 F Equipment EWT (C1) 0.0 F F Equipment LWT (C2) F T1 T2 0.0 LMTD T1 T2 0.0 LMTD Summer Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface ºF LMTD Winter ºF LMTD kbtu/hr Duty Load 0.0 kbtu/hr Btu/hr. ft2 ºF * 100 is default "U" Value * 80 Btu/hr. ft2 ºF ft² Suggested SLIM JIM Geo Lake Plate surface ft² SLIM JIM Geo Lake Plate Sizes GPM/SJ ft²/sj SJ Plates Suggested SJ Plates Suggested For SJ Plates Suggested SJ Plates Suggested For SLIM JIM Geo Lake Plate Sizes GPM/SJ ft² for Surface Area Application for Surface Area Application SJ-02T 24 in X 72 in ###### 24 SJ-02T 24 in X 72 in ####### 24 SJ-03T 48 in X 60 in ###### 40 SJ-03T 48 in X 60 in ####### 40 SJ-04T 48 in X 72 in ###### 48 SJ-04T 48 in X 72 in ####### 48 SJ-05T 48 in X 96 in ###### 64 SJ-05T 48 in X 96 in ####### 64 SJ-05TC 24 in X 180 in ###### 60 SJ-05TC 24 in X 180 in ####### 60 SJ-08T 48 in X 144 in ###### 96 SJ-08T 48 in X 144 in ####### 96 SJ-10T 48 in X 180 in ###### 120 SJ-10T 48 in X 180 in ####### 120 LEGEND LEGEND #### Version Brine / B = water with a freeze inhibiting solution WARNING POSSIBLE INPUT ERROR 20090908 EWT = equipment entering water temperature Select Units of Measurement EWT IS BELOW FREEZING - PLEASE CONSULT AWEB SUPPLY FOR SUPPORT US UNITS GPM/SJ = gallon per minute / Slim Jim Plate GPM/T = gallon per minute / System requirement HE = heat extracted in kbtu/hr HR = heat rejected in kbtu/hr LMTD = Logarithmic Mean Temperature Difference LWT = equipment leaving water temperature SJ = Slim Jim User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H1-C2= T1 & H2-C1= T2 Abbreviations and Definitions U = overall coefficient of heat transfer. Btu/hr. ft 2 ºF Water / W = water with no freeze inhibiting solution 0.0 100 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H1-C2= T1 & H2-C1= T2 * 100 is default Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply APPROACH TEMP IS TOO LOW - PLEASE CONSULT AWEB SUPPLY FOR SUPPORT You may use this program to obtain preliminary design selection of a SLIM JIM Geo Lake Plate for your application. Your use of this service is subject to the limitations set forth below. This program is provided as a convenience to our customers solely to assist them in design and selection of SLIM JIM Geo Lake Plate for their applications. We offer this service only as a preliminary design tool for use in selection of the SLIM JIM Geo Lake Plate. It is to be used for no other purpose. The validity and value of the results you achieve depend critically upon the accuracy of the information you provide. AWEB Supply disclaims any liability for the results you obtain using this program, and SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. You are encouraged to contact AWEB Supply at 888.277.2932 to obtain assistance in making your final selection

HVAC Project 1 Using the Slim Jim data is entered. The data from the specification sheet is entered in the Yellow cells Summer Design Geo Lake Plate design selection software, the Summer Water = W Brine = B B Pond/Lake Temp (C 1 ) Equipment EWT (H1) Equipment LWT (H2) Summer Cooling Condition Cooling HR / Calculate Equipment LWT EWT F LWT F HR (kbtu) 90.0 100.1 81.0 90.0 100.1 F (Enter the Warmest temperature) F F 684.3 GPM/T 135.00 T 1 T 2 9.0 19.1 LMTD 13.4 Summer Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface 13.4 684.3 100 509.2 ºF LMTD kbtu/hr Btu/hr. ft2 ºF f t² * 100 is default SLIM JIM Geo Lake Plate Sizes GPM/SJ ft²/sj SJ-02T 24 in X 72 in 6 24 SJ-03T 48 in X 60 in 10 40 SJ-04T 48 in X 72 in 12 48 SJ-05T 48 in X 96 in 17 64 SJ-05TC 24 in X 180 in 23 60 SJ-08T 48 in X 144 in 23 96 SJ-10T 48 in X 180 in 27 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 SJ Plates Suggested for Surface Area 21.22 12.73 10.61 7.96 8.49 5.30 4.24 SJ Plates Suggested For Application 22.00 13.00 11.00 8.00 9.00 6.00 5.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 1 Winter Design Using the Slim Jim data is entered. The data from the specification sheet is entered in the Yellow cells Geo Lake Plate design selection software, the Winter 29.994 Water = W Brine = B B Heating HE / Calculate Equipment LWT EWT F LWT F HE (kbtu) 35.0 Pond/Lake Temp (H 1 ) Equipment EWT (C1) Equipment LWT (C2) Winter Heating Condition 29.9 39.0 35.0 29.9 341.1 GPM/TOTAL 135.00 F (Enter the Coldest temperature) F WARNING FREEZE F INHIBITING SOLUTION REQUIRED T 1 T 2 4.0 9.1 LMTD 6.2 Winter Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface SLIM JIM Geo Lake Plate Sizes GPM/SJ 6.2 341.1 80 689.2 SJ-02T 24 X 72 4.7 24 SJ-03T 48 X 60 7.5 40 SJ-04T 48 X 72 9.0 48 SJ-05T 48 X 96 12.3 64 SJ-05TC 24 X 180 11.3 60 SJ-08T 48 X 144 16.9 96 SJ-10T 48 X 180 22.5 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 ft² ºF LMTD kbtu/hr Btu/hr. ft2 ºF ft² SJ Plates Suggested for Surface Area * 100 is default SJ Plates Suggested For Application 28.72 29.00 17.23 18.00 14.36 15.00 10.77 11.00 11.49 12.00 7.18 8.00 5.74 6.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 1 Dominate Condition Using the Slim Jim Geo Lake Plate design selection software allows you to design for the dominate condition for the size and configuration for the Slim Jim Geo Lake Plate required for this project. Suggested SLIM JIM Geo Lake Plate surface 509.2 ft²/sj SLIM JIM Geo Lake Plate Sizes GPM/SJ ft²/sj SJ-02T 24 in X 72 in 6.1 24 SJ-03T 48 in X 60 in 10.4 40 SJ-04T 48 in X 72 in 12.3 48 SJ-05T 48 in X 96 in 16.9 64 SJ-05TC 24 in X 180 in 22.5 60 SJ-08T 48 in X 144 in 22.5 96 SJ-10T 48 in X 180 in 27.0 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 SJ Plates Suggested for Surface Area 21.22 12.73 10.61 7.96 8.49 5.30 4.24 SJ Plates Suggested For Application 22.00 13.00 11.00 8.00 9.00 6.00 5.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply Summer Condition Winter Condition Suggested SLIM JIM Geo Lake Plate surface SLIM JIM Geo Lake Plate Sizes GPM/SJ SJ-02T 24 X 72 4.7 24 SJ-03T 48 X 60 7.5 40 SJ-04T 48 X 72 9.0 48 SJ-05T 48 X 96 12.3 64 SJ-05TC 24 X 180 11.3 60 SJ-08T 48 X 144 16.9 96 SJ-10T 48 X 180 22.5 120 LEGEND User Input: User to input their data in yellow fields 689.2 Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 ft² ft² SJ Plates Suggested for Surface Area 28.72 SJ Plates Suggested For Application 29.00 17.23 18.00 14.36 15.00 10.77 11.00 11.49 12.00 7.18 8.00 5.74 6.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 1 Selection Option 1 SLIM JIM Geo Lake Plate Sizes SJ-02T 24 X 72 4.7 24 SJ-03T 48 X 60 7.5 40 SJ-04T 48 X 72 9.0 48 SJ-05T 48 X 96 12.3 64 SJ-05TC 24 X 180 11.3 60 SJ-08T 48 X 144 16.9 96 SJ-10T 48 X 180 22.5 120 Winter Heating Condition SJ Plates Suggested GPM/SJ ft² for Surface Area 28.72 17.23 14.36 10.77 SJ Plates Suggested For Application 29.00 18.00 15.00 11.00 11.49 12.00 7.18 5.74 8.00 6.00 6SJ060TAM3F3

Installation Suggested list of items used for this type of installation: (1) - 3" Back Up Flange kit (To connect 3" Flange to 3" HDPE Pipe) (2) - 3" PE Fusion Elbow 90 Adapter 3" PE Pipe Misc. Nylon wire ties to secure the rebar to the HDPE pipe from the shore to the Slim Jim plate Misc. Rebar cut to short lengths to overcome the buoyancy and allow the liquid filled HDPE pipe to sink to the bottom from the shore to the Slim Jim plate Note: PVC pipe with caped ends can be added to allow the assembly to float at the surface of the water. This will allow the Slim Jim assembly to be placed into position before the system is flushed with fluid. Once the Slim Jim assembly is positioned and flushing of the loop system has started the PVC pipe will allow the Slim Jim assembly to submerge in the upright position and sink to the bottom as the air in the Slim Jim assembly is displaced with the fluid used in the loop system. Once the Slim Jim assembly skid plates have settled on the bottom and all the air is removed from the assembly the PVC pipe can remain in place.

4SJ040TAM3F3 Installation Photos Picture Perfect

Flushing The fluid flow from the Heat Pump equipment must enter the lowest connection on the Slim Jim assembly. The fluid flow returning to the Heat Pump equipment must exit the highest connection on the Slim Jim assembly. This will insure any remaining air in the system will not be trapped in the Slim Jim assembly. For proper operation and maximum performance, follow the Slim Jim or Geo Lake Plate SUGGESTED INSTRUCTIONS FOR INSTALLATION.

Auxiliary Heat Systems on any earth/lake loop in extreme conditions may call for auxiliary heat. When this happens and the return water to the unit is 32 F or less and the unit calls for auxiliary heat, it should be designed to stay engaged until the thermostat(s) are fully satisfied and the system shuts down. This will allow for down time and loop regeneration regardless of loop type In most applications a relay will need to be added to keep the supplemental heat engaged until the thermostat(s) are fully satisfied.

HVAC Project 2 Equipment Type Equipment: WaterFurnace Envision TM NS060-ECM Source Water Temperatures: Summer: 81 F (Warmest at installation depth) Winter: 39 F (Coldest at installation depth)

The Summer condition is circled in RED Capacity Data sheet WaterFurnace Envision NS060

Capacity Data sheet WaterFurnace Envision NS060 The Winter condition is circled in BLUE We need to extrapolate the data to find a EWT = 35 F EWT = 30 F with a HE of 31.8 kbtu/h EWT = 40 F with a HE of 39.2 kbtu/h The EWT spread from 30 to 40 is 10 (39.2 31.8) = 7.4 7.4 10 = 0.74 5 0.74 = 3.7 31.8 + 3.7 = 35.5 EWT = 35 F with a HE of 35.5 kbtu/h

HVAC Project 2 Summer Design Using the Slim Jim Geo Lake Plate design selection software, the Summer data is entered. Summer Cooling Condition The data from the specification sheet is entered in the Yellow cells Water = W Brine = B B 500 100.36 0 Pond/Lake Temp (C 1 ) Cooling HR / Calculate Equipment LWT EWT F LWT F HR (kbtu) 90.0 Equipment EWT (H1) Equipment LWT (H2) 100.4 81.0 90.0 100.4 F (Enter the Warmest temperature) F F 77.7 GPM/T 15.00 T 1 T 2 9.0 19.4 LMTD 13.5 Summer Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface 13.5 77.7 100 57.4 ºF LMTD kbtu/hr Btu/hr. ft2 ºF ft²/sj * 100 is default SLIM JIM Geo Lake Plate Sizes GPM/SJ ft²/sj SJ-02T 24 in X 72 in 5.0 24 SJ-03T 48 in X 60 in 7.5 40 SJ-04T 48 in X 72 in 7.5 48 SJ-05T 48 in X 96 in 15.0 64 SJ-05TC 24 in X 180 in 15.0 60 SJ-08T 48 in X 144 in 15.0 96 SJ-10T 48 in X 180 in 15.0 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 SJ Plates Suggested for Surface Area 2.39 1.44 1.20 0.90 0.96 0.60 0.48 SJ Plates Suggested For Application 3.00 2.00 2.00 1.00 1.00 1.00 1.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 2 Winter Design Using the Slim Jim Geo Lake Plate design selection software, the Winter data is entered. Winter Heating Condition The data from the specification sheet is entered in the Yellow cells 29.994 Water = W Brine = B B Heating HE / Calculate Equipment LWT EWT F LWT F HE (kbtu) 35.0 Pond/Lake Temp (H 1 ) Equipment EWT (C1) Equipment LWT (C2) 30.3 39.0 35.0 30.3 35.5 GPM/TOTAL 15.00 F (Enter the Coldest temperature) F WARNING FREEZE F INHIBITING SOLUTION REQUIRED T 1 T 2 4.0 8.7 LMTD 6.1 Winter Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface SLIM JIM Geo Lake Plate Sizes GPM/SJ 6.1 35.5 80 73.2 SJ-02T 24 X 72 3.8 24 SJ-03T 48 X 60 7.5 40 SJ-04T 48 X 72 7.5 48 SJ-05T 48 X 96 7.5 64 SJ-05TC 24 X 180 7.5 60 SJ-08T 48 X 144 15.0 96 SJ-10T 48 X 180 15.0 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 ft² ºF LMTD kbtu/hr Btu/hr. ft2 ºF ft² SJ Plates Suggested for Surface Area * 100 is default SJ Plates Suggested For Application 3.05 4.00 1.83 2.00 1.53 2.00 1.14 2.00 1.22 2.00 0.76 1.00 0.61 1.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 2 Dominate Condition Using the Slim Jim Geo Lake Plate design selection software allows you to design for the dominate condition for the size and configuration for the Slim Jim Geo Lake Plate required for this project. Suggested SLIM JIM Geo Lake Plate surface 57.4 ft²/sj SLIM JIM Geo Lake Plate Sizes GPM/SJ ft²/sj SJ-02T 24 in X 72 in 5.0 24 SJ-03T 48 in X 60 in 7.5 40 SJ-04T 48 in X 72 in 7.5 48 SJ-05T 48 in X 96 in 15.0 64 SJ-05TC 24 in X 180 in 15.0 60 SJ-08T 48 in X 144 in 15.0 96 SJ-10T 48 in X 180 in 15.0 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 SJ Plates Suggested for Surface Area 2.39 1.44 1.20 0.90 0.96 0.60 0.48 SJ Plates Suggested For Application 3.00 2.00 2.00 1.00 1.00 1.00 1.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply Summer Condition Winter Condition Suggested SLIM JIM Geo Lake Plate surface SLIM JIM Geo Lake Plate Sizes GPM/SJ SJ-02T 24 X 72 3.8 24 SJ-03T 48 X 60 7.5 40 SJ-04T 48 X 72 7.5 48 SJ-05T 48 X 96 7.5 64 SJ-05TC 24 X 180 7.5 60 SJ-08T 48 X 144 15.0 96 SJ-10T 48 X 180 15.0 120 LEGEND User Input: User to input their data in yellow fields 73.2 Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 ft² ft² SJ Plates Suggested for Surface Area 3.05 SJ Plates Suggested For Application 4.00 1.83 2.00 1.53 2.00 1.14 2.00 1.22 2.00 0.76 1.00 0.61 1.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

HVAC Project 2 Shallow Water 38 F Winter Design Using the Slim Jim Geo Lake Plate design selection software, the Winter data is entered. Winter Heating Condition The data from the specification sheet is entered in the Yellow cells 29.994 Water = W Brine = B B Heating HE / Calculate Equipment LWT EWT F LWT F HE (kbtu) 35.0 Pond/Lake Temp (H 1 ) Equipment EWT (C1) Equipment LWT (C2) 30.3 38.0 35.0 30.3 35.5 GPM/TOTAL 15.00 F (Enter the Coldest temperature) F WARNING FREEZE F INHIBITING SOLUTION REQUIRED T 1 T 2 3.0 7.7 LMTD 5.0 Winter Duty Load "U" Value * Suggested SLIM JIM Geo Lake Plate surface SLIM JIM Geo Lake Plate Sizes GPM/SJ 5.0 35.5 70 101.5 SJ-02T 24 X 72 3.0 24 SJ-03T 48 X 60 5.0 40 SJ-04T 48 X 72 5.0 48 SJ-05T 48 X 96 7.5 64 SJ-05TC 24 X 180 7.5 60 SJ-08T 48 X 144 7.5 96 SJ-10T 48 X 180 15.0 120 LEGEND User Input: User to input their data in yellow fields Calculated Values: These are formula and cannot be changed by user Information Only: H 1 -C 2 = T 1 & H 2 -C 1 = T 2 ft² ºF LMTD kbtu/hr Btu/hr. ft2 ºF ft² SJ Plates Suggested for Surface Area * 100 is default SJ Plates Suggested For Application 4.23 5.00 2.54 3.00 2.11 3.00 1.59 2.00 1.69 2.00 1.06 2.00 0.85 1.00 Flow Is BELOW Specs: Consult AWEB Supply Flow Is ABOVE Specs: Consult AWEB Supply

The Power of WATER Our Future

Thank You