HAMILTONT1 HAMILTONT1 Technical specifications As one of the best in its class, the HAMILTONT1 ensures the optimal ventilation therapy in transport situations for all patient groups from adult to neonate. The HAMILTONT1 complies with RTCA/ DO160G, EN 137181, and EN 1789, and offers: Performance of a fully featured ICU ventilator Approved for ambulances, helicopters, airplanes, and ships Independent air supply More than 9 hours of battery operating time Noninvasive ventilation and high flow oxygen therapy Advanced ventilation modes, including ASV Adult, pediatric, and neonatal ventilation For more information, visit our website: www.hamiltonmedical.com/t1 Optional not available in all markets
Ventilation Cockpit Dynamic Lung Vent Status ASV target graphics Monitoring Realtime waveforms Others Realtime visualization of the lungs with representations of tidal volume, lung compliance, resistance, and patient activity Visual representation of ventilator dependence, grouped into oxygenation, CO2 elimination, and patient activity Graphic display of target and current parameters for tidal volume, frequency, pressure, patient activity, and minute ventilation Display of more than 50 monitoring parameters Paw, Flow, Volume, Plethysmogram, and Capnograph SpO2, volumetric CO2, sidestream CO2, Loops: PV, VFlow, PFlow, VCO2, Trends: 1, 6, 12, 24, and 72 hours Alarms Operator adjustable Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen, low/high PetCO2, low/high SpO2, low/high pulse, low/high perfusion index, flow, low/high PVI, low/high SpCO, low/high SpMet, low/high SpHb Special alarms O2 cell, disconnection, exhalation obstructed, loss of PEEP, pressure not released, flow sensor, expiratory valve, pressure limitation, performance limited, CO2 and SpO2, battery, power supply, gas supply, oxygen concentration, check patient interface (HiFlowO2, SpeakValve) Loudness Adjustable (1 10), configurable minimum loudness Ventilation Modes Mode Description Adult/Ped. Neonatal Closedloop control ASV Adaptive Support Ventilation. Guaranteed minute volume based on user settings and application of lungprotective rules. Pressure PCV+ Pressurecontrolled ventilation. Biphasic breathing PSIMV+ Pressurecontrolled synchronized intermittent mandatory ventilation SPONT Pressure support ventilation APRV Airway pressure release ventilation DuoPAP Duo positive airway pressure Volume (S)CMV+/APVcmv (Synchronized) controlled mandatory ventilation SIMV+/APVsimv Synchronized intermittent mandatory ventilation Noninvasive NIV Noninvasive ventilation NIVST Spontaneous / timed noninvasive ventilation ncpap Nasal continuous positive airway pressure ncpappc Nasal continuous positive airway pressure pressure control HiFlowO2 High flow oxygen therapy Maintenance Blower lifetime Dynamic lifetime surveillance, typically 8 years. 5year warranty. Optional not available in all markets 2
Standards IEC 606011, IEC 6060112, ISO 80601212, CAN/CSAC22.2 No. 606011, ES606011, EN 7943, EN 1789 for ambulances, EN 137181, RTCA/DO160G for air transport, MILSTD461G control of electromagnetic interference Configurations Trolley accessories Options Humidifier support, cylinder holder, tubing support arm Volumetric mainstream capnography, sidestream capnography, DuoPAP/APRV, NIV/NIVST, Trends/Loops, Neonatal application, ncpap/ncpappc, NVG, SpO2, Masimo rainbow SET, PVI, 2nd battery, HiFlowO2, SpeakValve Accessories Multiple handles for various options (jet, ambulance, or bed rail mount) HAMILTONT1 carrying unit for bedside transport with O2 cylinder Electrical and pneumatic specifications Input voltage Power consumption Backup battery time Oxygen supply Low pressure oxygen Air supply Peak flow 100 to 240 V AC 15/+10, 50/60 Hz or 12 to 28 V DC (total range 10.2 to 30.3 VDC) 50 VA typical, 150 VA maximum Typical 8 h, maximum 9 h 25 min 2) with one internal battery and one hotswappable battery 280 to 600 kpa (41 to 87 psi), V max 200 (HPO 93 compatible) 15, max. 600 kpa (87 psi) for low pressure Integrated turbine 260 (adult / pediatric), 40 (neonatal) Environment Temperature Operating: 15ºC to 50ºC (adult / pediatric) / 15ºC to 40ºC (neonatal) Storage: 20ºC to 60ºC Humidity Altitude 5 to 95 noncondensing (operating), 10 to 95 noncondensing (storage) Adult 3) : Up to approx. 7,620 m (25,000 ft), 1,100 to 376 hpa Neonatal : Up to approx. 4,000 m (13,120 ft), 1,100 to 600 hpa Degree of protection IP24 Interface connectors USB, COM1 (RS232), nurse call, CO2, SpO2 Event log Storage and display of up to 1,000 events with date and time stamp IntelliTrig Automatic response to varying leaks and configurable trigger sensitivity in all modes Inspiratory leakage up to 85, expiratory leakage up to 40 PSync Guaranteed rate ventilation SpeakValve SpeakValve function makes the pressurecontrolled ventilation modes (PCV+, SPONT, PSIMV+) compatible with speaking valves Optional not available in all markets, 2) Reduced display brightness, 3
Controls Adult / Pediatric Neonatal Special functions Ventilation modes Patient groups Patient height Patient gender Patient weight (S)CMV+/ APVcmv SIMV+/APVsimv+ PCV+ NIVST PSIMV+ DuoPAP APRV ncpappc Tidal volume PEEP/CPAP Oxygen I:E ratio MinVol (ASV) Inspiratory time (TI) Flow trigger Pressure control Pressure support Pressure ramp P high (APRV/DuoPAP) P low (APRV) T high (APRV/DuoPAP) T low (APRV) Expiratory trigger sensitivity (ETS) Flow (HiFlowO2) PSync SpeakValve Manual breath, O2 enrichment, standby, sigh, screen lock, apnea backup ventilation, inspiratory hold, print screen, suctioning tool, dimmable screen, configurable quickstart settings, startup settings based on patient height and gender, integrated pneumatic nebulizer, O2 consumption display See page 2, Ventilation modes adult / pediatric 30 to 250 cm male / female 4 to 80 b/min 4 to 80 b/min 5 to 80 b/min 5 to 80 b/min 20 to 2,000 0 to 35 cmh2o 21 to 100 1:9 to 4:1 (DuoPAP 1:599 to 149: 25 to 350 0.1 to 12 s off, 1 to 20 5 to 60 cmh2o, added to PEEP/CPAP 0 to 60 cmh2o, added to PEEP/CPAP 0 to 2,000 ms 0 to 60 cmh2o 0 to 35 cmh2o 0.1 to 40 s 0.2 to 40 s 5 to 80 of peak inspiratory flow 2 to 80 on/off on/off Manual breath, O2 enrichment, standby, screen lock, apnea backup ventilation, inspiratory hold, print screen, suctioning tool, dimmable screen, configurable quickstart settings, startup settings based on body weight, O2 consumption display See page 2, Ventilation modes neonatal 0.2 to 30 kg 15 to 80 b/min 15 to 80 b/min 15 to 80 b/min 15 to 80 b/min (without PSync 5 to 80 b/min) 10 to 80 b/min 2 to 300 3 to 25 cmh2o 21 to 100 1:9 to 4:1 (DuoPAP 1:599 to 149: 0.1 to 12 s off, 0.1 to 5 0 to 45 cmh2o, added to PEEP/CPAP 0 to 45 cmh2o, added to PEEP/CPAP 0 to 600 ms 0 to 45 cmh2o 0 to 25 cmh2o 0.1 to 40 s 0.2 to 40 s 5 to 80 of peak inspiratory flow 2 to 12 on/off Optional not available in all markets 4
Monitoring parameters Parameter Unit Description Numeric monitoring Waveforms Vent Status Dynamic Lung Pressure Paw Ppeak Pmean Pinsp PEEP/CPAP Realtime airway pressure Peak airway pressure Mean airway pressure Inspiratory pressure Positive end expiratory pressure/ continuous positive airway pressure Flow Volume Pplateau Flow Insp Flow Exp Flow Volume VTE/VTE NIV VTI/VTI NIV ExpMinVol/MinVol NIV MVSpont/MVSpont NIV Leak/MV Leak ; Plateau or end inspiratory pressure Realtime inspiratory flow Peak inspiratory flow Peak expiratory flow Realtime tidal volume Expiratory tidal volume Inspiratory tidal volume Expiratory minute volume Spontaneous expiratory minute volume Leakage minute volume Time Lung mechanics Oxygen Carbon dioxide Vt/IBW (adult/ped) /kg Vt/Weight (neonatal only) /kg I:E ftotal b/min fspont b/min TI s TE s fspont Cstat /cmh2o AutoPEEP RCexp s Rinsp cmh2o*s/l RSB 1/l*min PTP cmh2o*s;mbar*s P0.1 O2 CO2 mmhg;;kpa FetCO2 PetCO2 mmhg;torr;kpa SlopeCO2 CO2/l VTalv VTalv/min V CO2/min /min VDaw VDaw/VTE VeCO2 ViCO2 Leakage percentage at the airway Tidal volume/ibw ratio Tidal volume/weight ratio Inspiratoryexpiratory ratio Total breathing frequency Spontaneous breathing frequency Inspiratory time Expiratory time Percentage of spontaneous breathing rate Static compliance AutoPEEP or intrinsic PEEP Expiratory time constant Inspiratory flow resistance Rapid shallow breathing index Pressuretime product Airway occlusion pressure Airway oxygen concentration (FiO2) Realtime CO2 measurement Fractional endtidal CO2 concentration Endtidal CO2 partial pressure V/Q status of the lung Alveolar tidal ventilation Alveolar minute ventilation CO2 elimination Airway dead space Dead space fraction measured at the airway opening Exhaled volume of CO2 Inspired volume of CO2 Optional not available in all markets 5
Monitoring parameters Parameter SpO2 Plethysmogram SpO2 Pulse Perfusion index SpO2/FiO2 PVI SpCO2 SpMet SpHb SpOC Physical dimensions Size Weight Display Main patient outlet Oxygen inlet Low pressure oxygen inlet 30 cm (11.8 in) 31 cm (12.2 in) Unit Description Realtime plethysmogram Arterial oxygen saturation in blood 1/min Heart rate /dl Calculation of the oyxgen content Calculated approximation of PaO2/FiO2 Pleth variability index Carboxyhemoglobin Methemoglobin g/dl Total hemoglobin /dl Oxygen content See illustrations below 6.5 kg (14.3 lb) with one battery and handle 5.6 kg (12.3 lb) without battery and handle 8.4 in, TFT color, backlit, touch screen, nightvision compatibility ISO 53561; 22OD/15ID DISS or NIST CPC quick coupling, 3.2 mm ID 24 cm (9.4 in) 21 cm (8.3 in) Numeric monitoring Waveforms Vent Dynamic Status Lung 136 cm (53.5 in) 689334.05 Specifications are subject to change without notice. ASV and IntelliTrig are trademarks of Hamilton Medical. 2016 Hamilton Medical AG. All rights reserved. Optional not available in all markets 63 cm (24.8 in) Hamilton Medical AG Via Crusch 8, 7402 Bonaduz, Switzerland ( +41 58 610 10 20 info@hamiltonmedical.com www.hamiltonmedical.com Your contact: