Case History. North Sea Platform Wellhead Isolation Tubing Hanger Body Seals Locking Device 20-3/4 x 13-3/8 Mandrel Neck Seal

Similar documents
Captain Wellhead & Tree

Case History. Kinetics Controls & Innovation Ltd

Platelets & Plasma The Management of Unplanned Flow

Copyright, 2005 GPM Hydraulic Consulting, Inc.

BRINGING A NEW DIMENSION TO PIPELINE PIGGING. By: David Aitken, Aubin Group, UK

5k Slickline Lightweight Pressure Control Equipment 4 ID

HYDROSTATIC LEAK TEST PROCEDURE

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL

VERTICAL BLADDER TANK

HORIZONTAL BLADDER TANK

PANACEA P200 STAINLESS STEEL USER MANUAL

SERVICE MANUAL No. I-0043

PANACEA P100 LOW PRESSURE USER MANUAL

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Subsea Safety Systems

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

6900 Maintenance Instruction System Flush

PRESSURISED PAINT CONTAINER

Float Operated Level Controllers

Retrievable Bridge Plugs

Hydro-Mech Bridge Plug

WELLHEADS, FLOWLINES & GAS LIFT INJECTION SYSTEMS

Assembling and testing fluid power systems

Liquid and gas sample tool

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Introduction to Ecoseal

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

On-Off Connector Skirt

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

NHR Powder Feed Hopper

Adjustable. Unloader Valve. O&M Manual. Part #

Monoblock Directional Control Valve RMB 202

Encore PE 50-lb Feed Hopper

Lesson 6: Flow Control Valves

Hydrostatic Pressure Testing

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

BIOCLOSURE SYSTEM ASSEMBLIES

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

PANACEA P125 USER MANUAL

Rhino VE CE Bulk Unloader Operator s Card

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR MKIII CONSTANT PRESSURE CYLINDER

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Budget Range Operators Handbook

3(752/(80 SPECIALTY 3(752/(80 SPECIALTY 5(17$/,1& 5(17$/,1&

NHR-X-X Encore Feed Hoppers

Double Pilot Operated Cartridge Check Valve, Size 8

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

RE545 reverse circulation Parts & tools guide

Pilot Operated Check Valves Catalog Quick Reference

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Gas / Liquid sampling tool Hydraulic operated

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

Instruction Manual Updated 7/26/2011 Ver. 2.2

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

BS ml Bottle Sampling Unit

Electrically Operated Pressure-Relief Cartridge, Size 10

Perforated Stator for Gas Control in PC Pumps Hollow Rotor for Controlling Solids Problems in PC Pumps

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

H4802, H4802-1, H , and Pole Tampers

Instruction Manual Updated 5/26/2009 Ver. 2.0

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

valves and actuators SUBSEA ACTUATION

Air Operated Hydraulic Pumping Systems to 50,000 psi

Best Practices - Coiled Tubing Deployed Ball Drop Type Perforating Firing Systems

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

CHE Well Testing Package/Service:

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Leak-Free Load-Control Valve SAE ½ psi flange

Series IRV1000/2000/3000

Successful Deployment of a Long Gun String Via Intelligent Coiled Tubing

Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP

F l o w c o n T R o l v a l v E S

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

Removal of hydraulic load holding valve incident causing injury

Plant, components and devices for very high and high pressures (7000 bar and over)

6800 Maintenance Instruction System Flush Procedure

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

All information correct as of 29 nd August 2013 and subject to change without notice CORRECT AS OF

HYDRAULIC CYLINDER TEST

COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pressure Sensing Valve - Model 4023

Related Products: Auto Drain Valve. Model/Specifications. Model

Emergency Pipeline Repair Isolation System

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

PRODUCT OPERATING MANUAL

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Pressure Dump Valve Service Kit for Series 3000 Units

Transcription:

Case History North Sea Platform Wellhead Isolation Tubing Hanger Body Seals Locking Device 20-3/4 x 13-3/8 Mandrel Neck Seal History / Introduction: Failed test issues as reported in 2001(SBMS-II, S Seal) Reference Kittiwake Wellhead Integrity Testing report August 2003 (2001) KCI evaluation and sealant deployment method. 9-5/8 x 5-1/2 Tubing Hanger 26 x 18-5/8 x 13-3/8 Casing 20 ¾ 3,000psi x 13-5/8 5000psi

Tubing Hanger Review: Tubing hanger neck seal, metal to metal, low pressure / monitoring test port 16. Tree spool gasket, metal to metal, Hanger void, monitoring / bleed port, test port 14 & 15. Tubing hanger locking device, resilient seals in OD & ID Hanger body cavity, test / monitoring port No.12 ( between resilient seal & metal seal) Lower hanger body cavity, test port Nos.10 & 11 (between metal seal & resilient seal) Polypack Seal Metal to Metal Seal Tubing Neck Test Port 16 T.B.A. Tree/ Spool Gasket Metal to Metal Hanger Void Hanger Void Monitoring / Bleeding Port 14 Void Test Port 15 Tubing Hanger Locking Device Resilient Seal Hanger Body Metal to Metal Seal Port 10 Resilient Seal Lower Hanger Body Cavity Hanger Body Cavity Port 12 Port 11

Tubing Hanger Evaluation: Hanger Body Cavity Test Fluid: Light Oil or Water Based Fluid Review: KCI Evaluation Fill void with test fluid i.e. inject test fluid through test port 14 and displace through port 15, close port 14 Vent / bleed hanger void, and ports 15,12, 11 & 10. Inject test fluid in through port 10 and displace through port 11. Close port 11 and lock in 2,000psi Inject a set volume of (1 Litre) test fluid through port 12 (500psi) and monitor leak rate and fluid displacement at port 15. Bleed / vent port 12, apply 2000psi within void through port 15 and monitor leak rate through port 12 (confirmation). Potential Leak Paths: 1/ Locking device resilient seal ID & OD. Void Test Port 15 2/ Metal seal above port 10 & 11 Void Monitoring/ Bleed Port 14 Port 12 Port 10 Port 11 Inject a set volume of Mac-Seal 06 ( 1.5 Litres) Inject a set volume of (1.5 Litres) sealant through port 12 (500psi) and monitor leak rate and fluid displacement at port 15. Allow 3 hours to cure. Vent / bleed ports 10 & 11 Void Test Port 15 Testing: inflow only: Pressure between ports 10 & 11 2000psi and sting / vent void port 15. Void Monitoring/ Bleed Port 14 Port 10 Sealant Port 12 Port 11 Mac-Seal 06 Application

13-3/8 Hanger, Neck Seal and Pack-off Review: Test Port 6: Supported by upper polypack seal and lower metal seal Test / monitor port 7: Supported by upper metal seal and S-Seal resilient seal ( ID & OD Seals) Test port 5: Void communicating with test ports 3 & 4 (drain ports) Test port 1 & 2 Pack-Off Port 6 Port 5 PolyPack Seal Port 7 Metal Seal Resilient Seal Port 3 Port 1 Port 4 Port 2

13-3/8 Hanger, Neck Seal and Pack-off Review: Neck Seal Port 6 Test Fluid: Light Oil or Water Based Fluid Review: Vent/bleed both annuli above and below Fill void with test fluid i.e. vent port 5 and close port 3. Inject test fluid through port 4 and displace through port 5 Close port 4 Sting and vent ports 6, 7, 5 Inject test fluid and maintain pressure (1000psi) through port 6 and vent / monitor port 7 for any fluid displacement. Maintain test pressure within port 6 and apply fluid test pressure through port 7 (500psi T.B.A) monitor leak rate through port 5. Port 6 Port 5 Port 7 Potential Leak Paths: 1/ Resilient casing neck seal. 2/ Metal seal Port 4 Port 3 Port 1 Port 2 Inject a set volume of Mac-Seal 02 (750mls) Maintain test pressure within port 6 and apply 750mls of Mac-Seal 06 through port 7 (500psi T.B.A). Allow 3 hours to cure Bleed / Vent port 6 Test / Monitor: Inflow test, pressure port 6 Sting and monitor port 5. Reverse the process. Close ports 3 & 4 Pressure test though port 5 Sting and monitor port 6 Port 3 Port 6 Port 5 Port 1 Port 7 Sealant Port 4 Port 2

K C I Kinetics Controls & Innovation Ltd Mac-Seal Products: Viscosities, 01, 02, 04, 06 Mac-Seal is a two-part sealant i.e. compound and hardener. The sealant is deployed as a fluid and converts to a solid but flexible self-energising seal structure within the void / cavity of the wellhead. The Mac-Seal sealant is designed as an emergency seal and is deployed as a temporary or permanent isolation across a number of applications. The Mac-Seal product is provided as a kit i.e. compound and hardener, with a set volume of hardener for a pre-determined curing time and to support on-the-job review and deployment procedures. Mixing Instructions: The product is provided in two parts: 1/ Compound, 2/ Hardener, Both products combined provides a package to meet a specified setting time. Note: The hardener measure is subject to curing time requirements and can be adjusted please contact KCI for advice on this if required. Standard setting times 2 to 12 hours -Surface Standard setting times 12 to 45hours -Subsea Review information label attached to both compound and hardener. Mixing: Use in well ventilated area. Do not mix in other containers as this may interfere with quality of product. KCI provides a large container (compound) to allow for mixing. Empty hardener fluid into compound and stir gently but thoroughly with a clean spatula or other device until mixed. Deployment: Subject to Viscosity 1/ Hand-held hydraulic injection gun. 2/ Pneumatic or hydraulic injection gun (large volumes). 3/ Cylinders 4/ Spatula Follow procedure (work scope) in accordance with the application and its environment. Note: This product is required to be deployed by KCI trained and registered personnel or trained and registered sub-contractors.

K C I Kinetics Controls & Innovation Ltd Deployment Tools Cylinders are provided as the method of deploying the sealant. These are designed as a simple process for preparation / handling, deployment (diver assist) and refurbishment. The cylinders have been designed to operate with seawater Cap Cylinder Piston Cap Injection Fitting 3/8 Control (Feed) Line 3 Litre Assembly Deployment Tool 3 Litres Deployment Manifold 3 Litres 3 Litre Deployment Cylinder 10K 10Litre 3 Litre Deployment Tool Hydraulic Hand Pump Mac-Seal Deployment Tool Assembly Mixing Instructions The Mac-seal is a two-part product i.e. compound and hardener. The product has been provided with set volumes of up to 3 litres of compound (white) and a set volume of hardener. Pour the set volume of hardener into the 3 litre tub (example) of compound and mix until the sealant becomes. Pour the mixed compound into the cylinder and attach to the deployment package. Note: Prepare all cylinders to receive the sealant prior to mixing 3 Litres of Mac-Seal 02 Mixed with Hardener 3Litres Sealant curing time: 3 hours subject to temperature Sealant deployment time: 1 hour after mixing. 3Litres Cylinder Support Stand Protect Fitting