TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

Similar documents
Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 3000 Units

LRS(H)4 Pressure-Reducing Regulator User Manual

GILMONT ACCUCAL FLOWMETERS

Tank Blanketing Pressure Regulators RHPS Series

3/8" Dr. Air Butterfly Impact Wrench

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

V-24 OXYGEN LANCE VALVE

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Model VR6 System. Installation, Operation & Maintenance

MK 3 Passive Operating Guide

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

MMR Air Mask With. with Quick-Connect Hose

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

ASSEMBLY & USE MANUAL

1200B2 Series Service Regulators. Instruction Manual

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

INSTALLATION and OPERATION INSTRUCTIONS

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Installation, Operation, and Maintenance Manual

Aquor House Hydrant V2

Technical Bulletin AL-134

Installation, Operation, and Maintenance Manual

Speed control assembly model A-1

4400 TwinHybrid Gas Seal

Chemical Injection Technologies Installation/Service Bulletin

CO2 Tank Conversion Kit P.N , P.N , and P.N

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

RD(H)20/25 Pressure-Reducing Regulator User Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

MAINTENANCE PROCEDURE FOR X 650

Multi-Probe Sampling System User Guide & Manual

CS150 CAP STAPLER OWNER S MANUAL

Section 3- Repair and Calibration Procedures

4-Ball Lowers 750cc, 1000cc, 1500cc, and 2000cc Models

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

SCUBAPRO Repair Guide. S600-S550 Second Stages

Assembly and Installation Procedures

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Instruction Manual Updated 7/26/2011 Ver. 2.2

Chapter 9 Accessories

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Operation Manual Piston Sensed Gas Pressure Regulators

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Techcon Systems TS1254 Pressure Pot

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Booster Pump PB4-60 Replacement Kits

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

SCUBAPRO. Balanced Power Inflator

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

Constant Pressure Crude Oil Container Model CPCCP

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS

INTENDED USE TECHNICAL SPECIFICATIONS

General Precautions for handling compressed gases

FisherPak Instructions

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

INSTRUMENTATION VALVES

Steel Spring Driven Reel Instruction Manual

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Alkylphosphines. Storage and Handling Recommendations

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

INSERT FITTINGS INSERT FITTINGS

Manual Solvent Purification System. Innovative Technology, Inc.

Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366

1800C and 1800C-HC Series Service Regulators

Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Purge Star & Ring Purge Systems

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Training Program 1A Filling 1 lb. Refillable Propane Cylinders

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

MB-SP Series Solvent Purification System

ATS430 turbidity sensor Retractable insertion assembly

Installation, Operation, and Maintenance Manual

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

Agilent 1290 Infinity Pump Head Maintenance

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Transcription:

Sigma-Aldrich Pure-Pac II System Technical Bulletin AL-236 TECHNICAL BULLETIN Product The Sigma-Aldrich Pure-Pac II packaging/dispensing system provides a convenient method for storing and dispensing laboratory and development scale quantities of high purity solvents, fine organics, and other high hazard liquids. The properties of these products require the prevention of external contamination and/or personal exposure be kept to a minimum. Many of the liquids must be handled and stored without exposure to atmospheric moisture or oxygen. The design of the Pure-Pac II system allows ready and convenient transfer of these liquids using the equipment and techniques described in this bulletin. Components All Pure-Pac II Containers are 304 Stainless Steel with Simriz gaskets and seals. Size Tare Weight Height Width (lbs) (inches) (inches) 20 L 16 20 11 50 L 31 23 16 200 L 99 38 24 Figure 2. Pure-Pac II Container Cutaway Sigma-Aldrich provides the special equipment needed for handling these deposit containers and their contents. A complete and detailed listing of equipment is furnished in the Appendix of this bulletin. Figure 1. Pure-Pac II Containers

2 Equipment Required For Dispensing (See Appendix for Dispensing kits) Micromatic MacroValve coupler Transfer line to connect the MarcoValve coupler and the process vessel/analytical instrumentation Inert gas supply (nitrogen or argon) Grounding Strap (Catalog Numbers Z197866, Z197904, or Z197912, see Appendix) Optional - level sensor available for 50 L and 200 L sizes Figure 3. Micromatic MacroValve Coupler 1 Nitrogen Inlet 2 Solvent Outlet 3 Coupler Handle 4 Pressure Relief 5 Extractor Valve Connector Precautions and Disclaimer This product is for R&D use only, not for drug, household, or other uses. Please consult the Material Safety Data Sheet for information regarding hazards and safe handling practices. Caution: Due to the hazardous nature of many of the products packaged in the Pure-Pac II containers, all users must read this bulletin carefully and completely before starting any actual laboratory/production work. If unsure of any of these procedures or need assistance, please contact Sigma-Aldrich prior to use. Storage/Stability Store the Pure-Pac II containers upright under positive nitrogen pressure in a well-ventilated area out of direct sunlight. Refrigerate when necessary. Any chemical residue on the outside or on top of the container must be removed. Failure to remove the chemical residue from the exterior of the container can result in damage of the container. The Pure-Pac II container must be clearly labeled with the product name and hazard labels. Please do not mark directly on the Pure-Pac containers. Use tags or place labels on the plastic sleeves to label as partial or empty. Procedure Upon receiving a Pure-Pac II container, reading and closely following the transfer procedure described in this bulletin, regardless of the quantity needed or the chemical transferred, is recommended. Since the products packaged in Pure-Pac II containers are typically sensitive to external contamination, highly hazardous, and may be reactive or sensitive to water, oxygen or both, they must be handled while using appropriate personal protective equipment and must never be exposed to the atmosphere. The user must be a fully qualified and experienced laboratory or chemical production worker to handle these reagents without problems. All users must be aware of the very hazardous nature of many of these products. The Material Safety Data Sheet (MSDS), which is provided with each order, must be read and understood by the user prior to starting any work with the product contained in a Pure-Pac II container. In general, handle only under an inert atmosphere and exercise caution to prevent inhalation of vapors or direct contact with the skin. Operators must wear appropriate personal protective equipment throughout the entire transfer procedure. During all nitrogen-pressure transfers, the flowing liquid can generate a static charge. Therefore, the container and receiver must be connected to a suitable ground (Catalog Numbers Z197866, Z197904, or Z197912, see Appendix). Technical experts are available by telephone to answer questions regarding the proper handling of products in Pure-Pac II containers. Contact Sigma-Aldrich immediately at 1-800-213-1206 if an inadvertent deviation from the recommended transfer procedure occurs during use of a Pure-Pac II container.

3 Assembly of MacroValve Coupler Dispensing Kit (Catalog Number Z566039, 3/8-inch tube fitting kit and Catalog Number Z566020, 1/2-inch tube fitting kit, see Appendix) 1. Wrap all male-npt threads with PTFE sealing tape. This will help seal the threads between the pipe thread fittings. The sealing tape should be wrapped tight and running in the same direction as the threads, so that the turning motion of the joining pipefitting follows the tape winding direction. This will keep the tape from unraveling during tightening. 2. Thread and tighten the 1-inch male-npt connection on the MacroValve coupler to the 1-inch female-npt 1/2-inch female-npt reducing coupler. 3. Thread and tighten the 1/2-inch male-npt 1/2-inch female-npt street elbow into the reducing coupler. 4. Thread and tighten either the 1/2-inch male-npt 3/8-inch tube fitting or 1/2-inch male-npt 1/2-inch tube fitting into the street elbow. 5. Thread and tighten the 1/4-inch male-npt 1/4-inch hose barb into the nitrogen inlet on the MacroValve Coupler. Transfer Procedure 1. Place the Pure-Pac II container in a secure and upright position in a safe and well-ventilated area. If the product is to be delivered by weight, secure the container on a floor scale. 2. Ground the container using an appropriate grounding strap (Catalog Numbers Z197866, Z197904, or Z197912, see Appendix). 3. Remove the protective cap on the extractor valve. 4. Connect a suitable nitrogen line to the nitrogen inlet on the MacroValve Coupler. Make sure the nitrogen source is turned off. 5. Connect the liquid transfer line to the outlet port on the coupler. Verify the process vessel or analytical instrumentation is prepared for the transfer and the in-line valve is closed. 6. Make sure the coupler handle is in the top (up) position, and the handle is in the inward orientation with the pin on the end of the handle fully extended out (see Figure 4). Align the coupler notched key with slots on the extractor valve and place the coupler on top of the extractor valve. The coupler should sit flush on top of the extractor valve (see Figure 5). Turn the coupler clockwise approximately 1/6 of a turn until it can go no further (see Figure 6). Note: There should be no resistance in turning the coupler. If any resistance is noted, please remove coupler and ensure coupler handle is completely in the up position. Figure 4. MacroValve Coupler with the handle in the inward orientation with the pin on the end of the handle fully extended out Figure 5. Alignment of the coupler notched key with extractor valve

4 Figure 6. Rotation of Coupler Figure 7. Engaging the coupler 7. Once the coupler is completely rotated into position, engage the coupler by pulling the handle outward while pushing down (see Figure 7). When the coupler is engaged correctly, the handle will lock into position in the inward orientation and the pin connected to the handle should audibly click into the locked position, thus preventing anyone from inadvertently disconnecting the coupler. The system is now opened. Caution: The handle cannot be pushed down if the coupler is incorrectly connected to the extractor valve. If excessive force has to be applied, return to step 4. Caution: The Pure-Pac II container has a slight positive pressure. Material will begin to flow through the coupler once it is engaged on the extractor valve. 8. Turn on the nitrogen source to begin pressurizing the Pure-Pac container. The pressure should be regulated to 5 psig. Caution: A properly functioning regulator must be used with the inert gas supply. The pressure should not exceed 12 psig. 9. Open the in-line valve on the liquid transfer line to begin transferring the liquid. 10. When the desired amount of liquid has been transferred, close the in-line valve on the liquidtransfer line and the valve on the nitrogen source.

5 Removing the Coupler 1. Close the nitrogen source to the coupler and the in-line valve on the solvent transfer line. 2. Pull the handle on the coupler outward. The handle will be forced to the up (closed) position (see Figure 8). There should be an audible click and the pin connected to the handle should pop out when the handle is in the inward orientation and fully up (closed) position. The system is now closed. Note: Do not attempt to rotate or remove the coupler until the handle is in the fully up (closed position). The coupler should rotate freely once the handle is fully disengaged. 3. Turn the coupler counterclockwise (see Figure 9) and remove it from the Pure-Pac container. Caution: The liquid-transfer line may still contain hazardous material. Always wear the proper protective equipment when handling the materials packaged in the Pure-Pac containers. Figure 9. Removal of Coupler Figure 8. Disengaging the handle Servicing/Cleaning the Coupler Caution: The MacroValve Coupler may still contain hazardous material. Always wear the proper protective equipment when handling the materials packaged in the Pure-Pac containers. 1. Remove hinge pin from coupler.

6 2. Pull handle assembly away from coupler. 5. Inspect the main gasket. Replace the gasket if it is damaged or worn. Do not use a lubricant on the gasket. This could affect the quality of the solvent. Note: Proceed to step 6 if the coupler needs to be completely cleaned. Otherwise, skip to step 11. 6. Remove NRV seal from probe. Once the seal is removed, the NRV spring can be removed. Caution: The probe may still contain hazardous material. Always wear the proper protective equipment. 3. Pull the probe assembly and coupler body apart from each other. 7. Clean the NRV and probe with the appropriate solvent. 8. Dry the NRV and probe. 9. Replace the NRV seal. The seal must be secured over the groove for proper installation. 4. Inspect the two O-rings from inside coupler body. Replace the O-rings if they are damaged or worn. Do not use a lubricant on the O-rings. This could affect the quality of the solvent.

7 10. Place the NRV seal assembly on the NRV spring. Press firmly into the probe until the seal locks into place. 12. Reinstall the handle assembly into the coupler body. Ensure that the locking arm is in the locking arm guide. 11. Reinstall the probe assembly into the coupler body. Do not use a lubricant on the probe. This could affect the quality of the solvent. 13. Replace the hinge pin. Note: Lock hinge pin securely.

8 Replacing the Pressure Relief Valve from the Coupler 1. Remove the coupler from the Pure-Pac II container. 2. Loosen the relief valve with a wrench. Unthread the relief valve from the coupler body. Container Return To return a Pure-Pac container to Sigma-Aldrich, the container must contain residual product only with the MacroValve Coupler detached. Any chemical residue on the outside of the container must be removed. Failure to remove chemical residue from the exterior of the container can result in damage to the container and may lead to the loss of the deposit. Empty Pure-Pac containers contain product residue, which is fully regulated as hazardous material and must be shipped in accordance with all applicable shipping regulations. Please do not mark directly on the containers or place any additional labels on the containers. Use tags or place labels on the plastic sleeve to label as empty and as needed for shipping purposes. Return empty Pure-Pac II containers to: Sigma-Aldrich Returns 5485 County Road V Sheboygan Falls, WI 53085-2814 Sigma-Aldrich has teamed up with Unishippers to provide an easy and straightforward option for returning empty Pure-Pac containers. To set-up an Unishippers account and to schedule a pick-up, please visit: sigma-aldrich.com/cylinderreturn. Pure-Pac is a registered trademark of Sigma-Aldrich Co. LLC. Simriz is a registered trademark of Freudenberg-NOK. Swagelok and SNOOP are registered trademarks of Swagelok Co. 3. Thread in the new relief valve and tighten with a wrench. KP,CK,PM,MAM 09/11-1

9 Appendix Pure-Pac II Dispense Coupler Kits - Z566020, MacroValve Coupler with 3/8-inch tube fitting and Z566039, MacroValve Coupler with 1/2-inch tube fitting MacroValve Coupler Kit Components Catalog Number Z560723 Z562300 Z562319 Z263532 or Z263567 Z565547 Z104388 MacroValve Coupler Reducing Coupler 1-inch female-npt 1/2-inch female-npt Street elbow 1/2-inch male-npt 1/2-inch female-npt 3/8-inch tube fitting 1/2-inch male-npt or 1/2-inch tube fitting 1/2-inch male-npt 1/4-inch male-npt 1/4-inch hose ID PTFE sealing tape MacroValve Replacement Parts Item Catalog Number 1 Z569070 MacroValve Dry Break NRV Spring for the Pure-Pac II MacroValve Coupler 2 Z569089 MacroValve NRV Spring Retainer for the Pure-Pac II MacroValve Coupler 3 Z569097 MacroValve Probe Seal, FFKM for the Pure-Pac II MacroValve Coupler 4 Z569100 MAV coupler probe O-Ring, FKM for the Pure-Pac II MacroValve Coupler 5 Z569119 Nylon Washer for the Pure-Pac II Macro Valve Coupler 6 Z569127 MacroValve Thread Adaptor Assembly for the Pure-Pac II MacroValve Coupler 7 Z569135 MacroValve Main Gasket, Viton for the Pure-Pac II MacroValve Coupler 7 Z569143 MacroValve Main Gasket, FFKM for the Pure-Pac II MacroValve Coupler 8 Z569151 MacroValve PRV Assembly, Viton 12 PSIG for the Pure-Pac II MacroValve Coupler 9 Z569178 MacroValve Handle Hinge Pin for the Pure-Pac II MacroValve Coupler 10 Z569186 MacroValve Pull Handle Assembly for the Pure-Pac II MacroValve Coupler

10 Quick-Connect Stem Catalog Number Z566055 Z562289 Z568465 Z562327 Swagelok PTFE-sealed quick-disconnect stem NPTM 1/4 inch (Swagelok part number SS-QTM2-D-4PM) Swagelok PTFE-sealed quick-disconnect stem NPTM 3/8 inch (Swagelok part number SS-QTM2-D-6PM) Swagelok PTFE-sealed quick-disconnect stem NPTM 3/8 inch (Swagelok part number SS-QTM4-D-6PM) Swagelok PTFE-sealed quick-disconnect stem NPTM 1/2 inch (Swagelok part number SS-QTM8-D-8PM) Quick-Connect Body Catalog Number Z566101 Z562343 Z562351 Swagelok PTFE-sealed quick-disconnect stem tube insert size 1/4 inch (Swagelok part number SS-QTM2A-B-400) Swagelok stainless steel PTFE-sealed quick-connect reducing adapter (Swagelok part number SS-QTM4A-B-600) Swagelok stainless steel PTFE-sealed quick-connect body NPTM 1/2 inch (Swagelok part number SS-QTM8A-B-810) Honsberg Level Sensor Display (Catalog Number Z562378) - For use with optional Pure-Pac II level sensor. Displays the volume or % remaining in the Pure-Pac II.

11 Micromatic MacroValve Flushing Adapter (Catalog Number Z566128) - Allows nitrogen to be flushed through the MacroValve Coupler and the solvent transfer line when they are disconnected from the Pure-Pac II container. Grounding Straps - Prevents sparking of static electricity generated by the transfer of flammable liquids. Catalog Number 3 ft L, 2 copper alligator clips Z197866 3 ft L, with 2 hand clamps Z197904 10 ft L, with 1/4-inch terminal and hand clamp Z197912 PFTE Sealing Tape - Eliminates the need for lubricants and vacuum greases on ground-glass joints, desiccators, bell jars, etc. Provides a vacuum-tight seal, yet will release readily even after long periods of time. Roll size is 520 inches. Catalog Number 1/4 inch wide Z148814 1/2 inch wide Z104388 1 inch wide Z221880 SNOOP gas leak detector (Catalog Number Z273910) - Nontoxic, nonflammable and leaves no residue. 8-oz. squeezable bottle with tube extendable to 12 inches for reaching places with limited accessibility. Transfer Lines, PTFE with Stainless Steel Braid Length 4 ft, endfitting size 1/4 inch, hose I.D. 1/4 inch Length 8 ft, endfitting size 1/4 inch, hose I.D. 1/4 inch Length 4 ft, hose I.D. 3/8 inch Length 8 ft, hose I.D. 3/8 inch Length 4 ft, endfitting size 1/2 inch Length 8 ft, endfitting size 1/2 inch Length 10 ft, hose I.D. 1 inch Catalog Number Z562394 Z562408 Z263591 Z263605 Z263613 Z263621 Z282707 2011 Sigma-Aldrich Co. LLC. All rights reserved. SIGMA-ALDRICH is a trademark of Sigma-Aldrich Co. LLC, registered in the US and other countries. Aldrich brand products are sold through Sigma-Aldrich, Inc. Purchaser must determine the suitability of the product(s) for their particular use. Additional terms and conditions may apply. Please see product information on the Sigma-Aldrich website at www.sigmaaldrich.com and/or on the reverse side of the invoice or packing slip.