Gas Pressure Sensor (Order Code GPS-BTA)

Similar documents
Respiration Monitor Belt (Order Code RMB)

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Vapor Pressure of Liquids

Dissolved Oxygen Probe (Order Code DO-BTA)

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Vernier Optical DO Probe (Order Code ODO-BTA)

Dissolved Oxygen Probe (Order Code DO-BTA)

Exploring the Properties of Gases

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

Vapor Pressure of Liquids

Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Exploring the Properties of Gases

Vapor Pressure of Liquids

Vapor Pressure of Liquids

Vapor Pressure of Liquids

Air Ball! Evaluation copy

Aerobic Respiration. Evaluation copy

PRESSURE-TEMPERATURE RELATIONSHIP IN GASES

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Lab #12:Boyle s Law, Dec. 20, 2016 Pressure-Volume Relationship in Gases

Boyle s Law: Pressure-Volume Relationship in Gases

Boyle s Law: Pressure-Volume Relationship in Gases

Boyle s Law: Pressure-Volume Relationship in Gases

Evaluation copy. Wind Chill. computer OBJECTIVES MATERIALS

Air Ball! LabQuest Vernier Gas Pressure Sensor Vernier Motion Detector basketball stopper with needle, stopper stem and tubing attached meter stick

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE

Pre-Lab 6: Gas Law ~ 70 ~

LABORATORY INVESTIGATION A Study of Yeast Fermentation - Teacher Instructions

APBiology Unit 2, Chapter 8

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

Lab 4: Transpiration

Biology Unit 2, Structure of Life, Lab Activity 2-3

The Decomposition of Hydrogen Peroxide

Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08

CBL Lab GAS PRESSURE & VOLUME MATHEMATICS CURRICULUM. High School. Florida Sunshine State Mathematics Standards

Boyle s Law. Pressure-Volume Relationship in Gases. Figure 1

The Gas Laws: Boyle's Law and Charles Law

Transpiration. DataQuest OBJECTIVES MATERIALS

Pressure Sensor Experiment Guide

Gas Laws. Introduction

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17

INSTRUCTOR RESOURCES

User s Guide. Pressure Controller for liquid delivery systems

Introduction. Objectives. Hazards. Procedure

NEULOG OXYGEN LOGGER SENSOR GUIDE

Fun with Gas Laws. Prepared by Vance O. Kennedy and Ross S. Nord, Eastern Michigan University PURPOSE

Gas Laws. Essential Learning Outcomes: 1. Change can be measured. 2. Changes can occur within a substance that alters its identity.

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Boyle s Law: Pressure-Volume. Relationship in Gases

How do the patterns of breathing and levels of oxygen change with different activities?

29 Pressure, Temperature relationship of a gas

Name Student Activity

Oxygen Sensor with Electrode

Auto-Zero Calibration Technique for Pressure Sensors

Boyle s Law: Pressure-Volume Relationship in Gases. PRELAB QUESTIONS (Answer on your own notebook paper)

Experiment 11: The Ideal Gas Law

AP Biology. Investigation 6: Cellular Respiration. Investigation 6: Cellular Respiration. Investigation 6: Cellular Respiration

Ideal gas law. Introduction

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Digital Vacuum Regulator

Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

User s Guide. Vacuum Controller for liquid delivery systems

86BSD Backside Digital Output

Heating of Land and Water. Evaluation copy. lamp with a 100 W (or greater) bulb. 2 Temperature Probes 2 one-hole stoppers 2 pans beaker.

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SX150A. Features. Typical Applications. Description

Pool Plunge: Linear Relationship between Depth and Pressure

ScienceScope Ltd, 12 Coombend, Radstock, BA3 3AJ Tel: Fax:

Exp. 5 Ideal gas law. Introduction

Gas Pressure and Distance The Force of the Fizz Within, By Donell Evans and Russell Peace

Optical Dissolved Oxygen Meter

Ref Product Description Price S1315 Logbook ML S1321 Primary ML S1326 Logbook GLE GPS S1328 Logbook GLE 220.

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

Experiment. THE RELATIONSHIP BETWEEN VOLUME AND TEMPERATURE, i.e.,charles Law. By Dale A. Hammond, PhD, Brigham Young University Hawaii

LABORATORY INVESTIGATION

Mitos Fluika Pressure and Vacuum Pumps Datasheet

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Pneumatic high-pressure controller Model CPC7000

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Intermolecular Forces

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Radnoti Liver Perfusion System

AMS 2710 PCB pressure sensor module with V output

Experiment C-6 Gas Solubility

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

What a Drag! Evaluation copy. Make observations and predictions about shoes. Measure the force needed to pull different shoes across a surface.

Pneumatic high-pressure controller Model CPC7000

ASDX Series Silicon Pressure Sensors

Transcription:

Gas Pressure Sensor (Order Code GPS-BTA) The Vernier Gas Pressure Sensor is used to monitor pressure changes in gas-law experiments in chemistry and physics, such as Boyle s law (pressure vs. volume) and Gay-Lussac s law (pressure vs. absolute temperature). Vapor pressure of various liquids and solutions can be monitored using this sensor. Biology teachers can use the Gas Pressure Sensor to monitor the production or consumption of oxygen or carbon dioxide gases in an enclosed atmosphere. The following is a partial list of activities and experiments that can be performed using this sensor. Investigate the relationship between pressure and volume, Boyle s law. Measure vapor pressure of liquids. Study the effect of temperature on gas pressure, Gay-Lussac s law. Monitor the production of O 2 during photosynthesis of an aquatic plant in a closed system. Determine the rate of transpiration for a plant under different conditions. Determine the rate of respiration in germinating pea or bean seeds. Monitor the pressure of a confined air pocket as water moves in and out of a semipermeable membrane by osmosis. Study the effect of temperature and concentration on the rate of decomposition of H 2 O 2. Study human respiratory patterns using the Vernier Respiration Monitor Belt. Gas Pressure Sensor Accessories Included with your Gas Pressure Sensor are accessories to allow you to connect it to a reaction container, such as an Erlenmeyer flask. Check to be sure that each of these items is included: two tapered valve connectors inserted into a No. 5 stopper one tapered valve connector inserted into a No. 1 stopper one two-way valve two Luer-lock connectors (white) connected to either end of a piece of plastic tubing one 20 ml syringe two transpiration tubing clamps (white) Potential uses of the accessories included with your Gas Pressure Sensor: The white stem on the end of the Gas Pressure Sensor Box has a small threaded end called a luer lock. With a gentle half turn, you may attach the plastic tubing to this stem using one of the luer connectors already mounted on both ends of the tubing. The Luer connector at the other end of the plastic tubing can Figure 1 then be connected to one of the stems on the rubber stoppers that are supplied, as shown in Figure 1.

The stopper can then be inserted into a flask or test tube to provide an airtight container to investigate a confined gas, as shown in Figure 2. Note: The second valve on the rubber stopper is shown in a closed position. The stopper can then be inserted into a flask or test tube to provide an airtight container to investigate a confined gas, as shown in Figure 2. Note: The second valve on the rubber stopper is shown in a closed position. You can also attach the 20 ml plastic syringe included with the Gas Pressure Sensor directly to this stem, as shown here in Figure 3. Figure 2 Figure 3 Collecting Data with the Gas Pressure Sensor This sensor can be used with the following interfaces to collect data. Vernier LabQuest 2 or original LabQuest as a standalone device or with a computer Vernier LabQuest Mini with a computer Vernier LabPro with a computer or TI graphing calculator Vernier Go! Link Vernier EasyLink Vernier SensorDAQ CBL 2 TI-Nspire Lab Cradle Here is the general procedure to follow when using the Gas Pressure Sensor: 1. Connect the Gas Pressure Sensor to the interface. 2. Start the data-collection software. 1 3. The software will identify the Gas Pressure Sensor and load a default datacollection setup. You are now ready to collect data. Data-Collection Software Logger Pro 3 This computer program is used with LabQuest 2, LabQuest, LabQuest Mini, LabPro, or Go!Link. Logger Pro 2 This computer program is used with ULI or Serial Box Interface. Logger Lite This computer program is used with LabQuest 2, LabQuest, LabQuest Mini, LabPro, or Go!Link. LabQuest App This program is used when LabQuest 2 or LabQuest is used as a standalone device. EasyData App This calculator application for the TI-83 Plus and TI-84 Plus can be used with CBL 2, LabPro, and Vernier EasyLink. We recommend version 2.0 or newer, which can be downloaded from the Vernier web site, 1 If you are using Logger Pro 2 with either a ULI or SBI, the sensor will not auto-id. Open an experiment file for the Gas Pressure Sensor in the Probes & Sensors folder 2

www.vernier.com/easy/easydata.html, and then transferred to the calculator. See the Vernier web site, www.vernier.com/calc/software/index.html for more information on the App and Program Transfer Guidebook. DataMate program Use DataMate with LabPro or CBL 2 and TI-73, TI-83, TI-84, TI-86, TI-89, and Voyage 200 calculators. See the LabPro and CBL 2 Guidebooks for instructions on transferring DataMate to the calculator. DataQuest Software for TI-Nspire This calculator application for the TI- Nspire can be used with the EasyLink or TI-Nspire Lab Cradle. LabVIEW National Instruments LabVIEW software is a graphical programming language sold by National Instruments. It is used with SensorDAQ and can be used with a number of other Vernier interfaces. See www.vernier.com/labview for more information. This sensor is equipped with circuitry that supports auto-id. When used with LabQuest 2, LabQuest, LabQuest Mini, LabPro, Go! Link, SensorDAQ, TI-Nspire Lab Cradle, EasyLink, or CBL 2, the data-collection software identifies the sensor and uses pre-defined parameters to configure an experiment appropriate to the recognized sensor. Specifications Pressure range 0 to 210 kpa (0 to 2.1 atm or 0 to 1600 mm Hg) Maximum pressure that the sensor can tolerate without 4 atm permanent damage Resolution 13-bit (SensorDAQ) 0.032 kpa (0.00032 atm or 0.24 mm Hg) 12-bit (LabPro, LabQuest 2, LabQuest, LabQuest Mini, Go! Link, or TI-Nspire Lab 0.06 kpa (0.0006 atm or 0.45 mm Hg) Cradle) 10-bit (CBL 2) 0.26 kpa (0.003 atm or 2.0 mm Hg) Sensing element Honeywell SSCMRNN030PAAA5 Accuracy typical ±0.25% FSS BFSL* Response time 100 microseconds Stored Calibration Values kpa slope 51.71 intercept 25.86 atm slope 0.5103 intercept 0 mm Hg slope 387.8 intercept 0 * Full Scale Span Best Straight Line 3

How the Gas Pressure Sensor Works The active sensor in this unit is the Honeywell SSCMRNN030PAAA5 pressure transducer. It has a membrane which flexes as pressure changes. This sensor is arranged to measure absolute pressure. One side of the membrane is a vacuum, while the other side is open to the atmosphere. The sensor produces an output voltage which varies in a linear way with absolute pressure. It includes special circuitry to minimize errors caused by changes in temperature. We provide an amplifier circuit that conditions the signal from the pressure transducer. With this circuit, the output voltage from the Gas Pressure Sensor will be linear with respect to pressure, with 0.00 volts corresponding to 0 kpa (0 atm) and 4.5 volts corresponding to the sensor s maximum pressure, 210 kpa (2.1 atm). Pressure Units Pressure can be measured in many different units. We quote values here in several of the units shown below. Some equivalent values for 1 atmosphere are 1 atmosphere = 101.325 kpa = 760 mm Hg = 29.92 in. of Hg (at 0 C) = 14.70 psi = 1013 millibar Optional Calibration Procedure You do not have to perform a new calibration when using the Gas Pressure Sensor in the classroom. We have set the sensor to match our stored calibration before shipping it. If you would like to perform your own calibrations, follow the steps described here. The standard calibration procedure we use with most of our sensors is a 2-point calibration. 1. First calibration point Allow the sensor to equilibrate to atmospheric pressure. When the voltage reading stabilizes, enter the atmospheric pressure, as recorded with a barometer. 2. Second calibration point Do one of the following. Use the syringe provided with the Gas Pressure Sensor to produce a pressure very near zero. Before connecting the syringe, push its plunger all the way in to the 0 ml mark. Connect the syringe directly to the Gas Pressure Sensor stem. To produce near-zero pressure, pull the plunger out to the 20 ml position. If your syringe and valve have a tight seal, the pressure will be ~ 0 kpa (0 atm or 0 mm Hg). Apply pressure with a pump, measuring it at the same time with a pressure gauge. 4

Suggested Experiments We have a wide variety of experiments already written for use with the Gas Pressure Sensor in our chemistry, biology, and physical science lab books.. Here are some of the experiments you can perform with your Gas Pressure Sensor. Boyle s Law (Pressure vs. Volume) Experiment 6, Chemistry with Vernier Experiment 30, Physical Science with Vernier Gay-Lussac s Law (Pressure vs. Absolute Temperature) Experiment 7, Chemistry with Vernier Experiment 31, Physical Science with Vernier Vapor Pressure Measurements Experiment 10, Chemistry with Vernier Rate of Plant Transpiration Experiment 10, Biology with Vernier Measuring Respiration of Insects Experiment 23, Biology with Vernier Control of Human Respiration Experiment 26, Biology with Vernier Pressure in Liquids: Depth Measurements If you measure the pressure at the end of a long plastic tube forced underwater, you can indirectly measure depth. Connect the tubing to the stem of the Gas Pressure Sensor and then put the end of the tube under water. The pressure reading will increase 8.105 kpa (0.0800 atm or 60.79 mm Hg) for every meter below the surface of the water. Note: If you measure depth in this way, the depth you are measuring is to the top of the air, which extends up the tube for a short distance. Additional Pressure Sensor Accessories In addition to the accessories that ship with the Gas Pressure Sensor, the following accessories are available for purchase. Item Order Code Pressure Sensor Accessories Kit PS-ACC #1 1-Hole Rubber Stopper PS-STOP1 #5 2-Hole Rubber Stopper PS-STOP5 Luer Lock Connector PS-LUER Plastic 2-Way Valve PS-2WAY Plastic Tubing PS-TUBING Stopper Stem PS-STEM Syringe PS-SYR Plastic Tubing Clamps (pkg. of 100) PTC 5

Warranty Vernier warrants this product to be free from defects in materials and workmanship for a period of five years from the date of shipment to the customer. This warranty does not cover damage to the product caused by abuse or improper use. Vernier Software & Technology 13979 S. W. Millikan Way Veaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com Rev. 5/3/2012 Logger Pro, Logger Lite, Vernier LabQuest, Vernier LabQuest Mini, Vernier LabPro, Go! Link, Vernier EasyLink and other marks shown are our trademarks or registered trademarks in the United States. TI-Nspire, CBL 2 and CBL, TI-GRAPH LINK, and TI Connect are trademarks of Texas Instruments. All other marks not owned by us that appear herein are the property of their respective owners, who may or may not be affiliated with, connected to, or sponsored by us. Sole Australian distributor: Scientrific Pty Ltd www.scientrific.com.au Ph: 02 6645 8111 Fax: 02 6645 8125 6