A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

Similar documents
special conditions and instructions for safe application

Füllstandtechnik GmbH Membrane level indicator Operating instructions Index Page Safety instructions Operating instructions Description

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

INSTRUCTION MANUAL Pressure Relief Device LPT

Junction Boxes Series 8118

Instruction Manual Contact Pressure Gauge

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Operating instruction

A18W35_MASE 130_F_EN MANUAL

Operating Instructions

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Glass tube flowmeters Series 2000

A17W23_MASE_MUS_EN MANUAL

Instruction Manual Contact Pressure Vacuum Gauge

Operating Instructions

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Further technical information is available on

Measurement of Low GAS & Liquid Flows

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Instruction Manual Differential Pressure Transmitter

OPERATING INSTRUCTIONS

Infrared Linescanners

PRESCODEM400, PRESCODEM400/220

Installation and Operating Instructions Bypass Flow Meter DST

Instruction Manual Differential Pressure Transmitter

Pneumatic pressure switch 20DD

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

NEW TYPE M PRESSURE RELIEF DEVICE

Installation, commissioning and servicing instructions

CFSW. Hinges with built-in safety multiple switch

Pressure Switches Application Guideline

Actuating elements for ComEx

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

Operating Manual VSA100A. tina29e1 ( )

Arran LED Floodlight Luminaire

Valvex Valves for Mining Applications

2-port seat valves PN25 with externally threaded connections

Pressure Reducing Valve DMV 755

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Operating Instructions

Pressure Reducing Valve DMV 750 set range: bar

Manual Power relay SR853

A17W49_MASEM_F_EN MANUAL

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

4/2 way Pneumatic Solenoid Valve

Magnetic level switch type MR783 Instruction Manual

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

IP65 Air Differential Pressure Switch

6-5 Maintenance Manual

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Position switches FP series

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

3-Way Safety Block DSV

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Pneumatic spool valve islands

CFSW. Hinges with built-in safety multiple switch

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

RR 16 Commercial & Industrial Regulator

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Type 4708 Supply Pressure Regulator

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

OPERATING INSTRUCTIONS

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

T-CITY. Waterproof protection for LED lighting

Flow controller Type ED/CCB311 Instruction manual

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC

Expansion Thermometers Stainless Steel Series, Model 70

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

ATS430 turbidity sensor Retractable insertion assembly

ATH-EXx. B Operating Instructions

MoveRoll Conveyor Operating and Maintenance Manual

Vibration isolation system 1VIS10W. User manual

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam

Type 4708 Supply Pressure Regulator

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Transcription:

,, CD, and PD Membrane level indicator for solids Operating Instructions Index Page Safety instructions................................................................................... 02 Operating instructions 1. Specification....................................................................................... 03 1.1 Intended use 1.2 Function 1.3 Technical data 1.4 Materials...................................................................................... 04 1.5 Dimensions 2. Installation......................................................................................... 04 2.1 Preparing for use 2.2 Mechanical connection 2.3 Electrical connection 3. Use............................................................................................... 05 3.1 Commissioning 3.2 Normal operation 3.3 Inexpert handling 4. Maintenance, servicing and spare parts................................................................ 05 4.1 Maintenance 4.2 Servicing 4.3 Spare parts 5. Storage............................................................................................ 05. Disposal.......................................................................................... 05 Depending on the model 0/14 by FILSA MI-MEM-EN-01 Talleres Filsa, S.A.U. E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 4 01 Fax +34 93 570 24 71 filsa@filsa.es www.filsa.es 01

,, CD, and PD Safety instructions 1. The installation, initial operation and maintenance should only be carried out by a qualified expert with electrical know-how. 2. Comply with the local and statutory rules and/or the VDE0100. 3. Before electrical connection, check the specifications on the data plate and the technical data of this manual. 4. A fuse must be connected in series to the supply voltage, according to the Standard and Normative documents. 5. Protect the signal contacts of the limit switch against voltage peaks when inductive or capacitive loads are connected.. The device may be put into operation only if the electrical connection is correct. To secure the type of protection, the sealing cap and the gasket must be placed correctly and the screw nut of the cable gland has to be fixed and fastened to the cable entry. 7. The earth connection of the device has to be installed in such a way that mechanical damage will be excluded. 8. Depending on the characteristics of bulk solids, define regular intervals of time to inspect the device and the membrane to detect damage or abrasion to the membrane. If there is damage to the membrane it is necessary change it to ensure the Type of protection. 9. Protect the device and the membrane from pointed objects. 10. Clean the device with a damp towel. Do not use any pointed objects or any aggressive chemical products. 11. It is recommended to mount the devices vertically. With this position the product can flow to and from the membrane. The device can be mounted horizontally for example to control obstructions in conveyors or can be mounted in surfaces with a maximum 40 º slope from the horizontal where the material can flow easily and leave the membrane without product. 12. 13. The high level controllers should be mounted low enough for the material to reach and totally cover the membrane before the high level signal is necessary. The low level controllers should be mounted high enough for the material to leave the membrane free with sufficient anticipation to actuate to the control systems. For a proper type of protection, the device should be installed respecting the position of the cable glands or, depending on the models, the labels with the orientantions, for example in models with air filter. 14. Switch off the power supply, before disconnecting the device. 0/14 by FILSA MI-MEM-EN-02 02 Talleres Filsa, S.A.U. E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 4 01 Fax +34 93 570 24 71 filsa@filsa.es www.filsa.es

,, CD, and PD Operating instructions 1. Specification 1.1 Intended use The membrane level indicator are to be used to control the maximum or minimum level of bulk solids in silos or vessels. These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy 3 flow and a bulk density from 0.3 to 2.5 t/m. 1.2 Function The membrane must to be exposed to the material. The movement of the switch is the result of the pressure exerted by the incoming bulk material against the membrane which forces the membrane to move backwards, reversing the position of the switch and the signal is used for exampleto control the transport system in the silo. The models,, SR y and the models with S.S. membrane have a regulation system by a spring that allows the adjusment of the sensitivity. Tightening the regulation nut to reduce the sensitivity and increase the strain of the material to activate the microswitch. Clockwise insensitive. The models are adjusted at their maximum sensitivity. It is necessary to ensure the proper pressure to the membrane that returns the membrane when there is no product covering it. 1.3 Technical data Manufacturer Talleres Filsa, S.A.U. Address Bernat Metge, 33 08100 Mollet del Vallès (Barcelona) Name Membrane level indicator Type ref: 2210-... Density of the product Ambient pressure Maximum pressure Cable entry ref: 2212-... CD ref: 2201-... ref: 2204-... PD ref: 2205-... 0.3 t/m... 2.5 t/m 3 3 Atmospherical +0.5 bar Ø 9 mm, cable gland M12x1.5 dependiong on the model, CD,, PD sensitivity in Stainless Steel membrane models. sensitivity in SR and models. sensitivity in models. MEM-001 MEM-002 MEM-003 Maximum voltage Contact function Capacity of the contact 250 V AC 1 A / 250 V AC, CD,, PD 15 A / 250 V AC models S and ES 5 A / 250 V AC (for resistive loads) For inductive or capacitive loads reduce at 50% Ambient temperature CD, PD CD, PD with Aluminium housing Temperature of product with membrane of Viton with S.S. membrane Protection, CD, PD CD, PD with Aluminium housing, CD, PD with S.S. membrane CD, PD S.S. and Alum. housing Weight CD CD with Aluminium housing PD PD with Aluminium housing Sensitivity S with S.S. membrane CD, PD CD, PD SR adjustable Sens. 1 NO + 1 NC -10 ºC... +0 ºC -20 ºC... +80 ºC -20 ºC... +0 ºC -25 ºC... +80 ºC -20 ºC... +70 ºC -20 ºC... +150 ºC -20 ºC... +200 ºC IP44 IP53 / IP40 depending on the position of the cable gland IP5 IP IP5 0.2 kg 1.85 kg 0.48 kg 0.95 kg 0.49 kg 1 kg 0.73 kg 20... 0 g 100... 200 g 35... 45 g 200... 500 g 80... 90 g 0... 1.000 g CDS, PDS 30... 40 g CDES, PDES CD, PD with S.S. membrane According DIN EN0529 15... 25 g 150... 2.000 g 0... 200 g 0/14 by FILSA MI-MEM-EN-03 Talleres Filsa, S.A.U. E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 4 01 Fax +34 93 570 24 71 filsa@filsa.es www.filsa.es 03

,, CD, and PD 1.4 Materials Housing ABS Aluminium, RAL 7001 covered CD, PD, Glass reinforced Polyester (Under request CD, PD with Aluminium housing) extra disk PVC Membrane NBR (Under request Viton), CD, PD NBR (Under request Viton, Stainless Steel 1.4301) 2 membranes NBR (Under request exterior membrane Viton) Mounting ring and screws Aluminium ring, RAL 7001 covered and screw zincated Steel (Under request Stainless Steel 1.4301) CD, PD, Zincated Steel (Under request Stainless Steel 1.4301) 1.5 Dimensiones Approximate measures are given in mm. 5x72 º PD Ø 5.2 Ø 90 Ø 103 3.5 20 38 MEM-00 25 49 MEM-007 Ø 83 Ø 9 50 MEM-008 2. Installation CD Ø 200 Ø 214 Ø 187 4 14 3.5 Ø 110 0 MEM-004 2.1 Preparing for use - Read the Safety instructions and the Operating instructions before using the controller. - Verify and inspect the device and membrane to detect possible damage to the membrane during the transport or installation. 2.2 Mechanical connection Drill holes in the silo or vessel and mount the indicator using screws, rods, fasteners or nuts making sure of the easy flow of the material and ensure that the product leaves the membrane without product on it. 2.3 Electrical connection Connection diagram 49 MEM-005 C NO NC 1 3/4 2 MEM-009 0/14 by FILSA MI-MEM-EN-04 04 Talleres Filsa, S.A.U. E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 4 01 Fax +34 93 570 24 71 filsa@filsa.es www.filsa.es

,, CD, and PD 3. Use Cable gland - After electrical connection, tighten the cable gland. - Screw the cap nut, until the cable entry is closed tightly to ensure the water-thigtness. 3.1 Commissioning - Put the level indicator into operation only, if the installation and the electrical connection have been done correctly. 3.2 Normal operation - Use the device in its intended application only. - Comply with the specifications on the data plate and the technical data of this manual. - If the controller is damaged, disconnect it immediately. - It is forbidden to make changes to the device. This violates the Normative. 3.3 Inexpert handling - Ignoring the Safety instructions and the Operating instructions. - Not intended use. - Making changes or handling the controller. - Violation against applicable Law and Standards. - Using of non original parts. 4. Maintenance, servicing and spare parts 4.1 Maintenance - If used correctly, no specific maintenance is required. - Depending on the characteristics of bulk solids, define regular intervals of time to inspect the device and the membrane to detect damage or abrasion to the membrane. If there is damage to the membrane it is necessary change it to ensure the Type of protection. 4.2 Servicing - Be in mind that, with the passing of time, the values of the actuating pressure can be affected due to the temperature effect and/or due to the effect of a constant pressure. - Check and review the state of the housing, the membrane and the correct commutation of the electric contact, as well. 4.3 Spare parts - Use only original parts. - The spare parts of the level indicator can be consulted in the document R-MEM-01. 5. Storage - Store the level indicator in a dry and dust-free envirnoment.. Disposal - Switch off the power supply, before disconnecting the device. - The level indicator can be recycled. - The disposal applies to the valid environmental Guidelines according to the location of he carrier and the local manufacturing conditions. FILSA, en un constante esfuerzo por mejorar sus productos, se reserva el derecho de modificar diseños, materiales y datos sin indicación expresa. Conserve este manual para posibles futuras consultas! 0/14 by FILSA MI-MEM-EN-05 Talleres Filsa, S.A.U. E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 4 01 Fax +34 93 570 24 71 filsa@filsa.es www.filsa.es 05