DeFelsko PosiTector CMM IS Probe

Similar documents
DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

Calibration Procedure

Calibration Procedure

Calibration Procedure

PosiTector UTG, UTG-STD & UTG-ME

Calibration Procedure

Calibration Procedure. PosiTest DFT Combo

Calibration Procedure

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

ali-q TM Gravimetric Verification Procedure

PRODUCT SHEET. Order probe only as RXPROBE02

Optical Dissolved Oxygen Meter

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

CAPBs. From a simple measuring instrument to an all-rounder with CAPBs

Owner s Manual Humiport 10/20

CALIBRATING THE GMA PRESSURE SENSORS AND THE ECU ENGINEERING UNIT

8.1 Calibration of gas sensors

In Vivo Scientific, LLC INSTRUCTION MANUAL

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

4.0 Audit Procedure for the MetOne SASS Speciation Sampler

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

DQM Annual Hopper QA Checks

DO NOT PRINT THIS PAGE

Model of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer

Advanced Test Equipment Rentals ATEC (2832)

Transmitter CS 21 Operation Manual

Ambient Weather WS-03 Thermo-Hygrometer

DISSOLVED OXYGEN SENSOR BT34i

GE Measurement & Control

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

2014 Programme of Training Courses in Measurement & Calibration

BI-680 Online Dissolved Oxygen Controller Instruction Manual

WBEA Standard Operating Procedure

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Advanced Test Equipment Rentals ATEC (2832)

PRELIMINARY DATASHEET

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

PS-425 Pitot-Static/Air Data Tester

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Met One E-BAM Particulate Monitor

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Pitot-Static System - Inspection/Check ICA Supplement

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Additel 761 Automated Pressure Calibrators

P06 & P012 Pitot-Static Probes

SMART Oxygen Analyzer. User Manual

! Warning, refer to accompanying documents.

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Pneumatic high-pressure controller Model CPC7000

Simrad GD10P Extended On-site Maintenance

DBI version 002 User Manual US version Free Balloon Flight Instrument

Thermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities

P8 to P60 Pitot-Static Probes

DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual

We measure it. For gas and water installers. testo hpa. bar

Heavy Duty Dissolved Oxygen Meter

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Operation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

AMS 6916 Board mount pressure sensor with ratiometric analog output

Technical Procedure for General Laboratory Equipment

Do Not Print This Page.

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Digital pressure gauge Model CPG500

Digital Vacuum Regulator

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. K

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Soil Water Characteristic Curve (SWCC) Using the WP4C

testo Leakage detector for refrigerants Instruction manual

HumiSys HF High Flow RH Generator

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

TECHNICAL DATA CAUTION

Sartorius CCL kg Prototype Mass Comparator

Standard Operating Procedure

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

Testing of Active Flow Control actuators at harsh environment

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Additel 761 Automated Pressure Calibrators Selection Guide

Any use of this material except in accordance with a written agreement with Western Power is prohibited.

Additel 761 Automated Pressure Calibrators

9101 Zero Point Dry-Well

RGC-IR Remote Gas Calibrator for IR400

GMA FUNCTIONAL TEST SETTING & TESTING OF SPIN UP PARAMETERS. P0586 REV -- 20, June 2000 GPB SCIENCE MISSION PROCEDURE

User s Guide Temperature Sensor Converter TSC-599

Transcription:

Management Procedure 2566 Revision: A Date Issued: January 23, 2018 Date Revised: Calibration Procedure DeFelsko PosiTector CMM IS Probe Table of Contents 1 Introduction and UUC Performance Requirements... 2 Table 1-1 Measurement Ranges... 2 2 Measurement Standards and Support Equipment Performance Requirements... 2 Table 2-1 UUC Accuracy Requirements and Description... 2 Table 2-2 Minimum Use Specifications... 2 Table 2-3 Actual Equipment Specifications... 2 Table 2-4 Calibration Environment and Warm-Up Requirements... 3 3 Preliminary Operations... 3 4 Calibration Process... 3 5 Performance Requirements... 4 Table 5-1 Requirements and Calibration Data for DeFelsko PosiTector CMM IS Probe... 4 Management Procedure Change Notice... 5 Management Procedure MP 2566 Rev A Page 1 of 5

1 Introduction and UUC Performance Requirements 1.1 This procedure describes the calibration of the DeFelsko PosiTector CMM IS probe with the following specifications: Table 1-1 Measurement Ranges Function Measurement Range Resolution 0 to 80 C 0.1 C Air Temperature (32 to 176 F) (0.1 F) Relative Humidity 10 to 100% RH 0.1% 1.2 The unit being calibrated will be referred to as the UUC (Unit-Under-Calibration). 2 Measurement Standards and Support Equipment Performance Requirements 2.1 The UUC accuracy requirements are based upon the published UUC performance specifications. 2.2 The test uncertainty ratio applied in this calibration procedure is 4:1 unless otherwise stated. 2.3 Minimum-Use-Specifications are the minimum test equipment specifications required to meet all the UUC accuracy requirements and the test uncertainty ratio applied. Table 2-1 UUC Accuracy Requirements and Description UUC Function Range Accuracy Test Method 0 to 80 C ± 0.5 C Air Temperature (32 to 176 F) (± 1.0 F) Humidity Generator 10 to 90% RH ± 2.0 % Relative Humidity > 90% RH ± 3.0 % Table 2-2 Minimum Use Specifications Function Range Accuracy 0 to 80 C ± 0.125 C Air temperature (32 to 176 F) (± 0.25 F) Relative Humidity 0 to 100% RH ± 0.75% Table 2-3 Actual Equipment Specifications Manufacturer/Model # s Actual Equipment Applicable Specifications Range Accuracy 0 to 70 C ± 0.06 C Thunder Scientific Model 2500 (60 to 140 F) (± 0.11 F) Humidity Generator 10 to 95% RH ± 0.5% Management Procedure MP 2566 Rev A Page 2 of 5

Caution: The instructions in this Calibration Procedure relate specifically to the equipment and conditions listed in this section. If other equipment is substituted, the information and instructions must be interpreted accordingly. Table 2-4 Calibration Environment and Warm-Up Requirements Temperature: 23 ± 5 C. Relative Humidity: Less than 95% Barometric Pressure 30 ± 1.5 in Hg (1016 ± 50mbar) Measurement Standards & Support Equipment Environmental Requirements: Measurement Standards & Support Equipment Warm-up and Stabilization Requirements: Thunder Scientific Humidity Generator: 60 minutes 3 Preliminary Operations Note: Review the entire document before starting the calibration process. 3.1 Visual Inspection 3.1.1 Damage or excess wear must be repaired prior to beginning the calibration process. 3.1.2 Visually inspect the UUC for: Wear or damage to the probe body or sensor end Missing parts Proper identification 3.2 Ensure the UUC has been stored within the calibration check chamber for at least 24 hours. 3.3 Remove the battery cap, insert a battery and replace the battery cap. 3.4 Using a smart device, launch the PosiTector SmartLink app and verify the device detects the probe. Also verify the probe has at least 25% battery. 4 Calibration Process Refer to UUC and equipment instruction manual(s) for menu navigation instructions, details on features and operating instructions. Note: Whenever a test requirement is not met as indicated in table 6-1, verify the results of the test and take corrective action before proceeding. 4.1 Place the probe(s) in the humidity chamber such that the sensor end is exposed. Do not set the sensor on the bottom of the chamber with the sensor facing down. Multiple probes Management Procedure MP 2566 Rev A Page 3 of 5

can be calibrated in the chamber simultaneously. Record the probe serial number(s) and the Barometric pressure (mbars). 4.2 Adjust the set point of the humidity chamber to 50 %RH and allow to stabilize for at least 2 hours. After the stabilization time, record the chamber relative humidity and air temperature. Use a smart device to access the UUC as describe in section 3.4. Record the UUC relative humidity and air temperature. 4.3 Adjust the set point of the humidity chamber to 90 %RH and allow to stabilize for at least 2 hours. After the stabilization time record the chamber relative humidity reading. Use a smart device to access the UUC as describe in section 3.4. Record the UUC relative humidity. 4.4 Remove the probe(s) from the chamber, remove the battery and immediately store in the Calibration Check Chamber. 5 Performance Requirements Note: The technician will collect the data needed to complete columns D and E. The technician shall then calculate the values for Column F and record all information as shown in table 5-1. Do not write in this procedure. Table 5-1 Requirements and Calibration Data for DeFelsko PosiTector CMM IS Probe Reference (A) Units (B) Set Point (C) Test Equipment Reading (D) Gage Reading (E) Probe Measurement Accuracy (F) Allowable Tolerance (G) Relative Humidity %RH 50 ± 2.0 Ambient Temperature C N/A ± 0.5 Relative Humidity %RH 90 ± 2.0 Note: To convert from C to F T F = 1.8 * T C + 32 Management Procedure MP 2566 Rev A Page 4 of 5

Management Procedure Change Notice Procedure Number: MP 2566 Revision Level: A Date of Change: January 23, 2018 Title: Calibration Procedure for DeFelsko PosiTector CMM IS Probe Reason for Change: New product Description of Change: New procedure I confirm I have read and understand the procedure and the change described above. Printed Name Signature Date Management Form 0010.02-05/1998 Management Procedure MP 2566 Rev A Page 5 of 5