Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Similar documents
WW-730. Pressure Sustaining/Relief Control Valve

WW-720. Pressure Reducing Control Valve

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

WW-720. Pressure Reducing Control Valve

Bermad Pressure Reducing. Model: 42T

Model: 43T. Bermad Pressure Relief Valve

Model 420-HY Pressure Regulating Hydrant Valve

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Pressure Reducing Control Valve w/ Hydraulic Check Feature

SINGER MODEL 106/206-RPS-L&H

DS05C,D,G Dial Set Pressure Regulating Valves

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation Troubleshooting Maintenance Instructions Installation / Start-up

MEGR-1627 Instruction Manual

OPERATING AND MAINTENANCE MANUAL

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

D05T Compact Design Pressure Regulating Valves

D05 Pressure Regulating Valves

Discharge Relief Valve Operation & Maint.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

DS06D,G Dial Set Pressure Regulating Valve

TECHNICAL DATA. Q = C v P S

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

DOUBLE ACTING ALTITUDE VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

BACK PRESSURE / SUSTAINING

RS(H)20, 25 USER MANUAL

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

BACK PRESSURE / SUSTAINING

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

1805 Series Relief Valves

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q= Cv S

Operation Manual Piston Sensed Gas Pressure Regulators

1200B2 Series Service Regulators. Instruction Manual

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Types 749B and R130 Changeover Manifolds

Operating Instructions Model and Hydrostatic Test Pump

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Rate of Flow Valve Series 120

HIGH RATE BASKET STRAINER

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

1305 Series Pressure Reducing Regulators

Waterous Relief Valve

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

1800C and 1800C-HC Series Service Regulators

Regulator from 1800 B series

Type ACE95jr Tank Blanketing Valve

Type FEQ Slam-Shut Valve

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Combination Air Valve

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

TECHNICAL DATA CAUTION

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Models: C62/63/64-A/D

Type CT88 Backpressure Regulator

Types S100K and S102K Pressure Regulators

Speed control assembly model A-1

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Installation, Operation, and Maintenance Manual

ZW209 & ZW209BP LEAD-FREE*

Temperature Controllers

V43 Pressure Actuated Water Regulating Valve

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

MEGR-1912 Instruction Manual

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Adjustable. Unloader Valve. O&M Manual. Part #

64 Series Pressure Reducing Regulators

Pneumatic Powered - Plunger Pumps

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

TECHNICAL DATA CAUTION

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

LRS(H)4 Pressure-Reducing Regulator User Manual

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Regulators. Operating Instructions. Instrumentation

Lesson 6: Flow Control Valves

Suggested Installation & Operating Instructions for Sidewinder Pumps

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

627 Series Pressure Reducing Regulators

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Transcription:

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Model CYCLE GARD II, CI & CNA YOUR PRODUCT INFORMATION: Model Number: Date: Serial Number: Valve Size: Factory Pilot Preset: psi High Quality Valves Built to Last... 15 PRUYNS ISLAND GLENS FALLS, NY 12801 800-833-2040 * 518-761-9797 * Fax: 518-761-9798 Outside U.S. 518-761-9799 worldwideweb://www.flomatic.com * e-mail: flomatic@flomatic.com

CYCLE GARD VALVE The Model Cycle Gard Valve with external adjustable by-pass Threaded Female x Female Connection 150# Class Grooved Connection Pressure Reducing Pilot Factory Set @ 60 psi NOTE: Submersible motor manufacturers recommend using a flow inducer sleeve to be sure the motor is properly cooled at low flows. Do not exceed 125 psi pressure differential across the valve. SHIPMENT: When shipped, controls are usually mounted on the main valve. If control subassemblies are shipped separately, all connections are tagged to insure correct assembly. INSTALLATION: 1. Flush the pipeline before inserting the valve and turn power off. 2. Install the valve with the "arrow" on body pointing in the direction of flow (usually towards the tank or reservoir). 3. Attach sub-assemblies to main valve if necessary, pressure switch and controls should be installed close to the tank. 4. Allow enough clearance above valve for removal of diaphragm assembly. CAUTION: The maximum pressure rating of the standard Cycle Gard II is 250 PSI, Cycle Gard CI is 225 psi. If the inlet pressure (or pump shut off head) is higher, a second pressure relief valve Model C401, with greater capacity, will be required. A relief valve shall be installed to protect the tank form excessive pressure. START-UP: 1. Install pressure gauges to inlet and outlet (optional). 2. Open both shut-off valves on the control assembly. 3. Open 1/4" air bleeder at the top of the valve. (Re-close after step 4 or step 5.) 4. Open main line shut-off valve on the outlet side of the main valve to about 1/4 open. 5. Slowly open main line shut-off valve on the inlet side. 6. Pre-charge pressure in the tank should be 5-10 PSI lower than pressure switch turn on pressure. All valves are factory pre set to 60 PSI. To re-adjust reduced pressure loosen outer jam nut on the pilot valve and turn adjustment screw clockwise (into cover) to increase downstream pressure, or turn counterclockwise (out of cover) to lower downstream pressure. CAUTION: any adjustment should be done slowly. Open a line downstream and allow the pump to turn on. Slowly close supply valve downstream until demand is approximately 6-10 GPM (about ¾ line). Then adjust the valve to the desired downstream constant pressure, at least 5 PSI lower than the cut off pressure of the pressure switch setting. 7. The tank fill rate can be easily adjusted with the external by pass on opposite side of pilot valve. Adjust the by pass valve to full open lower the run time of pump or close valve slightly to increase run time (A minimum of 2 GPM is recommended for tank fill rate. NOTE: Do not totally close the by pass valve. OPERATION: The Model Cycle Gard with external adjustable by-pass maintains a preset, reduced downstream (outlet) pressure by causing the diaphragm to throttle and sustain the desired reduced pressure regardless of variations in demand and upstream (inlet) pressure. The throttled position of the diaphragm is controlled by an adjustable pilot valve operating in conjunction with an orifice (or needle valve). The pilot valve sense the downstream (outlet) pressure and reacts immediately to reposition the diaphragm assembly as the outlet pressure tends to increase or decrease with varying flow demand. The pilot valve piston will automatically sense changes inflow of the system as it continuously controls the main valve to throttle or to open maintain the desired, preset reduced outlet pressure. The external adjustable by-pass allows higher pressure to by-pass around the valve seal at a controlled rate allowing the system to reach its desired shut off point. Adjusting the ¼ test cock on the by-pass open shortens the run time of the pump until shut down. Adjusting the ¼ test cock on the by-pass closed will lengthen the run time of the pump until shut down.

Installation Instructions Model C101N NOTE: All Cycle Gard type of valves need to be located within close proximity to the tank and pressure switch Flomatic Corporation can accept no responsibility for possible errors in catalogues, brochures and other printed material. Flomatic Corporation reserves the right to alter its products without notices. This also applies to product already agreed. All trademarks in this material are property of the respective companies. All right reserved. 2011 Flomatic Corporation. The drawings & information on this drawing sheet are the sole & exclusive property of Flomatic Corporation. Any reproduction, distribution, display or use of these drawingsor information in whole or in part without written authorization of Flomatic Corporation is strictly prohibited. FLOMATIC CORPORATION GLENS FALLS, N.Y. 12801 October 4, 2001 Dwg No: cycle2pipe Rev: E (5/11) PHONE (518) 761-9797 FAX (518) 761-9798 Flomatic Corporation

Installation Instructions Model CIN101 NOTE: All Cycle Gard type of valves need to be located within close proximity to the tank and pressure switch Flomatic Corporation can accept no responsibility for possible errors in catalogues, brochures and other printed material. Flomatic Corporation reserves the right to alter its products without notices. This also applies to product already agreed. All trademarks in this material are property of the respective companies. All right reserved. 2011 Flomatic Corporation. The drawings & information on this drawing sheet are the sole & exclusive property of Flomatic Corporation. Any reproduction, distribution, display or use of these drawingsor information in whole or in part without written authorization of Flomatic Corporation is strictly prohibited. FLOMATIC CORPORATION GLENS FALLS, N.Y. 12801 April 1, 1999 Dwg No: cycle_ci_pipe Rev: E (5/11) PHONE (518) 761-9797 FAX (518) 761-9798 Flomatic Corporation

Installation Instructions Model CNA101 NOTE: All Cycle Gard type of valves need to be located within close proximity to the tank and pressure switch Flomatic Corporation can accept no responsibility for possible errors in catalogues, brochures and other printed material. Flomatic Corporation reserves the right to alter its products without notices. This also applies to product already agreed. All trademarks in this material are property of the respective companies. All right reserved. 2011 Flomatic Corporation. The drawings & information on this drawing sheet are the sole & exclusive property of Flomatic Corporation. Any reproduction, distribution, display or use of these drawingsor information in whole or in part without written authorization of Flomatic Corporation is strictly prohibited. FLOMATIC CORPORATION GLENS FALLS, N.Y. 12801 October 19, 2006 Dwg No: cycle_cna_pipe Rev: D (5/11) PHONE (518) 761-9797 FAX (518) 761-9798 Flomatic Corporation

TROUBLE SHOOTING GUIDE CAUSE 1. Main valve is air bound. 2. Shut-off valve at the outlet side of control is closed. 3. Ruptured diaphragm in pilot valve. (Evidenced by leak from vent hole in cover.) 4. Fouled orifice or flow control valve. 5. Fouled strainer. 6. Pressure switch or valve not set properly 7. Damaged pilot valve seat. 8. Debris lodged under seal of main valve. 9. Leakage from one or more fittings in the controls. 10. Water tank has become waterlogged. 11. More than 125 psi pressure differential across valve 1. Incorrect adjustment of pilot valve. (Set too high) 2. Flow control valve (if installed) open too far. 3. Shut off (isolation) valve at the outlet side of the controls is closed. 4. Fouled pilot valve 5. Worn or eroded orifice (or needle valve seat). 1. Flow control valve (or needle-valve at the outlet side of controls) is out of adjustment of may be clogged with debris. 2. Pilot valve seal is damaged. 3. Pressure tank is too far away from valve 4. Air pressure in tank too high A. PROBLEM : Pump cycles or valve opens and will not close B. PROBLEM: Valve is closed and will not open. CORRECTION 1. Open 1/4" air bleeder at the top of valve to release air. 2. Open shut-off valve. 3. Replace diaphragm. 4. Flush flow control valve or remove and clean orifice. 5. Disassemble, clean or replace screen. 6. Change valve or pressure switch so switch setting is higher than valve. 7. Disassemble and remove debris replace damaged parts. 8. Disassemble and replace damaged parts. 9. Tighten or replace fitting. 10. Recharge tank or replace. 11. Add a second valve in series 2 staging pressure drop 1. Turn pilot valve adjusting screw counter clockwise slowly until the valve opens and the desired reservoir level is reached. 2. Turn adjusting screw clockwise slowly until valve opens. 3. Open shut-off (isolation) valve. 4. Disassemble and clean, replace seat ring and seat seal if necessary. 5. Replace orifice (or needle valve). C. PROBLEM: Valve hunts or chatters. 1. Slowly turn adjusting screw and/or remove to inspect for debris. 2. Replace seal 3. Locate tank and valve closer or an additional smaller tank closer to the valve. 4. Make sure tank pressure is 5-10 PSI lower than pressure switch turn on pressure. Test To Isolate Source Of Problem (After visual inspection of external leaks) 1. With the main line gate valves open and the reducing valve pressurized, close the control shut-off (isolation) valve at the outlet side of the pressure reducing pilot control. THE MAIN VALVE SHOULD CLOSE. If the valve remains fully open the source of the problem could be: (A) fouled orifice or needle; (B) fouled strainer; (C) control shut off valve at inlet is closed; (D) ruptured main valve diaphragm. If the valve is partially closed the source of the problem could be: (A) damaged: main valve seat packing or seat ring; (B) debris under seat; (C) main valve is air-bound; (D) damaged stem O-ring. If the valve closes fully, the source of the problem could be: (A) pilot valve out of adjustment; (B) damaged pilot valve stem or set ring; (C) partially fouled strainer or needle valve. 2. With the main line gate valves open and the reducing valve pressurized, close both shut-off (isolation) valves and open the air bleeder pet cock to release water out of the power chamber above the diaphragm of the reducing valve. Water will flow from the pet cock as the valve moves to the full open position. If water continues to flow, the source of the problem could be: (A) damaged: main valve diaphragm or stem seal O-ring; (B) loose locknut.