Industrial Filter. FGD series

Similar documents
Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Air operated valve. VGA342R Series

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Lightweight and Compact Type Floating Joint

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

5 Port Air Operated Valve

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

IR1000-A IR1010-A IR1020-A

reduces flow setting time and setting errors!

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Related Products: Auto Drain Valve. Model/Specifications. Model

Series IRV1000/2000/3000

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Filter-Regulator-Lubricator

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Parallel Seal Type Slit Valve

5 Port Solenoid Valve

Series AMJ. Drain Separator for Vacuum

Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

High Vacuum L Type Valve PRODUCT NAME. XLF Series MODEL/ Series

Pilot Check Valve: Metal Body Type

Coiling Tube with Twist-Proof Fitting

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Moisture Control Tube

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Precision Regulator IR3120

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Process Pump PB1000A

Pressure Sensor PSE53#

Air preparation filter

Pressure Sensor PSE54#

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Vacuum Pad with Ejector. Series ZHP

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Push-In Fitting Type Silencer

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Low torque Metal seal type Rotary joint

Push-In Fitting Type Pressure Gauge

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Tube Cutter with Measuring tape built-in

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Operation Manual Air Saver Unit ASV5000 Series

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Push-In Fitting Type with Stop Valve

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Pressure Gauge Series

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Pressure Sensor for General Fluids PSE56#

Filter-Regulator-Lubricator

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Compressed Air Cleaning Filter Series

Tube for General Pneumatic Piping

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

PVC Quick Drain Valve

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Angle Seat Valve / Air Operated Type

Multi Core Tube for General Pneumatic Piping

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Process Pump. Flare type (LQ3 fitting) added to the type with nut. Series PAF CAT.ES100-59C. Series PAF5000. Series PAF3000. New

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Combination Air Valve

WHEATLEY Series 822/820 Swing Check Valve

Booster Regulator/Air Tank

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

WHEATLEY Series 500 Swing Check Valve

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

TECHNICAL DATA. Page 1 of 12

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Speed control assembly model A-1

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

FLANGED TWO-PIECE BALL VALVES

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Transcription:

1/8 P r o d u c t N a m e Industrial Filter Model/ Series/ Product Number FGD series FGD - - - Material Accessory Element length Element Port size

Contents 2/8 Safety Instructions 3 Safety Instructions for the FGD Series 5 Parts Descriptions and Functions 6 Product Specifications 7 Installation/Piping 7 How to Replace the Element 7

Industrial Filter Safety Instructions 3/8 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) *1), and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. ISO 4413: Hydraulic fluid power -- General rules relating to systems. IEC 60204-1: Safety of machinery -- Electrical equipment of machines.(part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. etc. Danger indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

4/8 Industrial Filter Safety Instructions 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer 1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first. 2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.

FGD Series/Specific Product Precautions Be sure to read this before handling. 5/8 These safety instructions are intended to prevent hazardous situations and/or equipment damage. Make sure to follow every instruction since they are for safety. Operating conditions range 1Operating pressure Do not operate the product outside of the specified operating pressure range. Do not use the product where the pressure exceeds the operating pressure range due to water hammer, surge etc. The operating pressure for the product operated with gaseous fluids is 0.5 MPa. 2Operating temperature Do not operate the product outside of the specified operating temperature range. 3Fluid Do not use the product for flammable, toxic, or corrosive fluids. Do not use any fluid which will cause the seal, O-ring or element to swell or deteriorate. 4Operating environment Do not use in environments where there is a danger of corrosion. Do not use the product where it can be exposed to vibration or impact. Operating Instructions 1Never loosen the bolt while pressure is being applied to the product. 2Do not use a bolt which is deformed or has a damaged thread. 1Replace any deteriorated or swollen seals with new ones. Replace seals within 1 year after starting use, when replacing the element, or if fluid leakage occurs. (Seal set for replacement: Refer to Table 1 and 2 on page 6.) Design and Installation 1 Design the system with operating conditions, including operating pressure, operating temp., operating fluid, and operating environment appropriate for safe operation. 4Take measures to avoid burning when the product is used in high temperature. 5Prepare air discharge circuit where necessary. 6Prepare a drainage discharge circuit where necessary. 7Use the filter with a circuit in which the changing load of pressure and flow is small. 8Use a circuit which does not lead to backflow to the filter. Maintenance and Inspection 1Foreign matter shall be discharged from the drain outlet. 2Replacement of the element When it is the time for replacement of the element, replace it with a new one immediately. The life of element When pressure drop reaches 0.1 MPa. Replacement should be performed according to the procedure in this operation manual. Incorrect handling can cause damage of equipment and device, and operation failure. (How to replace the element: Refer to page 7.) 3Cleaning of parts When replacing the element, clean the seat surface of the seals and threads for sealing properly. 4Surface temperature To avoid burning, confirm that the surface temperature is 40 o C or lower when replacing the element. For high temperature use, attention should be taken to avoid burning. Piping and operation 1Check the IN/OUT and connected piping. 2Check each port size for selecting valves and fittings suitable for operating conditions. Flush piping line with air before operation to check for any problems including fluid leakage. 3When supplying pressure by starting the pump, open the relief port (hexagon bolt) to discharge air. Release the air (loosen the hex. bolt) at the same time supplying the fluid to substitute air in the product with fluid. When air is discharged, close the relief port (tighten the hex. bolt) before starting operation. 1Pressure drop ( P) Use the product with the flow rate such that the initial pressure drop is 0.02 MPa or less 2Installation space When installing and piping, allow sufficient space for maintenance. 3Flushing This filter generates particles at first. Before initial operation, flush the piping enough to remove the particles completely.

1. Parts Descriptions and Functions 6/8 IN OUT Table 1-1 Parts Descriptions and Functions No. Part name Material Function 1 Stainless steel or iron Hexagon head bolt 2 Seal Resin Plug to release air in the housing 3 Nut Stainless steel or iron Tightens the cover. 4 Seal Resin 5 Cover Stainless steel or iron The lid of the filter body 6 Gasket Resin or rubber 7 Guide Stainless steel Seals the gap between the element and tension bolt Depends on the 8 Element element type The mounted element collects residue. 9 Tension bolt Stainless steel or iron Connects the case and cover 10 Joint Stainless steel Seals the area between elements (when two FGD B elements are used) 11 Case Stainless steel or iron Filter body 12 Holder Stainless steel Seals the elements 13 Seal Resin or rubber 14 Washer Stainless steel 15 Spring Stainless steel Stabilizes the element 16 Seal Resin 17 Plug Stainless steel or iron Drainage discharging plug DRAIN Figure 1 Parts descriptions and functions (Figure shows the product with two FGD B elements.) Table 1-2 Replacement parts Applicable Name Part No. model FGD-KT001 FGDC Nut kit FGD-KT002 FGDE FGD-KT003 FGDT FGD-KT004 FGDF 03 Replacement FGD-CV005-04 06 FGDT,F cover 03 FGD-CV006-04 FGDC,E 5 06 Joint FGD-OP001 FGD 10 KT-FGDC FGDC Seal kit KT-FGDE FGDE KT-FGDT FGDT KT-FGDF FGDF Part No. (Kit contents) Each of 1,2,3 and 4 are provided as a kit. Each of 2,4,6,13 and 16 are provided as a kit.

2. Product Specifications Table 2 Specifications Model FGDCA, B FGDEA, B FGDTA, B FGDFA, B Fluid Various kind of liquid (Industrial water, washing liquid, general solvent, etc.) Port size (Rc) 3/8, 1/2, 3/4 Max. operating pressure (MPa) Note 1) 0.7 1.0 Max. operating temperature ( o C) 80 Number of elements FGD A: 1 Note 2) FGD B: 2 Element size (mm) Note 3) Differential pressure for element replacement (MPa) Main materials FGD A: Φ65 x 250 FGD B: Φ65 x 500 (For 2 elements: Φ65 x 250) Cover Aluminum SCS14 Case SPCE SUS316 Gasket/O-ring NBR Fluororesin Seal Weight (kg) body only Fluororesin Nylon (Antistatic specification) FGDCA, FGDEA: 1.3 FGDCB, FGDEB: 2.2 FGD A: 1.7 Internal capacity (L) FGD B: 3.4 3. Installation and Piping (1) Check the IN/OUT direction before piping. (2) Use clean pipes for piping. (3) Use sealant tape without peeling off. (4) Apply spanner to the filter cover when piping to the filter. Never perform piping by holding the filter case. (5) Secure a space (50 mm or more) under the filter so that the element can be taken out. 7/8 4. How to Replace the Element 4-1 Removal of element (1) Stop the fluid entering the filter. (2) Loosen the hexagon head bolt (air vent), and release the internal pressure of the filter completely. (3) Remove the plug to discharge drainage in the filter. (4) Loosen the nut, and remove the case. Move the element 50 mm downwards together with the case, and then remove it by moving it horizontally. (5) Take the element out of the case. * When two elements (250 mm) are used, be careful not to lose the joint which seals the elements. It will be reused later. (6) Clean the inside of the case, gasket, seals and plug with clean fluid or solutions. * Do not remove the tension bolt from the case. 4-2 Mounting of element (1) Replace the gasket and seals with new ones. (2) Put the tension bolt through the hole of the element, and then insert the element into the case. * When two elements (250 mm) are used, insert a joint between the elements. (3) Align the tension bolt with the center hole of the cover, and insert the case, in which the element has been inserted, into the cover. (4) Hold the case from the bottom, and tighten a nut from the top of the cover. (Tightening torque: 25 Nm for FGDT, F/15 Nm for FGDC, E) (5) Confirm that there is no leakage or flow out of foreign matter after trial run. Then, start operation of the product. To prevent foreign matter from getting inside the product during replacement, make sure to perform flushing and confirm that no foreign matter flows out before starting operation. 0.1 Fluororesin Fluororesin (Antistatic specification) FGDTA, FGDFA: 2.3 FGDTB, FGDFB: 3.8

8/8 Revision history Revision A: - Seal kit contents (page 6) - The number of seal and gasket provided as a kit was changed from 10 to 1. Revision B: - Contents added to Product Precautions (page 5) - Table 1-2 Replacement parts added (page 6) - Contents of "How to Replace the Element" revised (page 7) 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2013 SMC Corporation All Rights Reserved